• Title/Summary/Keyword: Perforation Rate

Search Result 137, Processing Time 0.027 seconds

A Study of the Physical Properties of Weft Knit Fabrics (위편조직(緯編組織)의 물성(物性)에 관한 연구(硏究))

  • Kim, In-Suk;Lee, Soon-Hong
    • Journal of Fashion Business
    • /
    • v.2 no.4
    • /
    • pp.93-101
    • /
    • 1998
  • Knit products which had been limited only to underwear, recently became popularized, fashionized and highly classified covering even outer garments such as sportswear like golfwear, woman's dress, and man' s suit. As fashion cycle is getting shorter and the more a nation advanced prefers knit to woven fabrics knit industry has a very bright prospect, particularly woman's knit which is sensitive to fashion can be said as a fashion product with high value added. This study is to grasp the physical properties of stitch which are fundamental to the development of knit products. For this purpose, 2/20s of 100% wool were woven by the author of this study to basic plain stitch, rib stitch, varied transfer stitch, and float stitch on a SEMASEIKI cross knitter 7G to test the physical properties, and the result was as follows; 1. As for the relation between knit stitch and rate of extension recovery, rate of extension recovery was higher in the course direction than in the wale direction of three stitches except transfer stitch; rib stitch showed the highest rate of extension recovery in the course direction while float stitch showed the highest rate of extension recovery in the wale direction. 2. As for the relation between knit stitch and bursting strength elastic rib stitch showed higher bursting strength to indicate elasticity is an important factor of bursting strength and float stitch showed higher bursting strength too to indicate that the floating yarn on the surface plays a role of support. 3. As for the relation between knit stitch and air permeability perforated transfer stitch showed the lowest air permeability to prove that the size of perforation affects on the air permeability a great deal. 4. As for the relation between knit stitch and warmth retaining rib stitch through two lined needle bar showed the highest degree. The reason the warmth of perforated transfer stitch didn't decrease much was because the perforation wasn't big enough and content of air increased from the unevenness of the perforated parts through stitch variation. Based upon this result, each stitch can be characteristically summarized as follows; plain stitch showed a stable condition of knit cloth in four kinds of physical property test. And rib stitch is proper to tighten the edge of sleeve or clothe making use of its excellent extension recovery and to make socks for the highest bursting strength and warmth retaining. In the case of transfer stitch, seasonable designs can be taken by controlling the size of loop. Considering the pleasantness, underwear should be made of stitches with good air permeability float stitch was revealed to have color and pattern effects and a great bursting strength. This study has limitations in the aspect that it dealed with a small part of various knit stitches and the items of physical property test were not enough. The author of this study hopes that further studies would make deeper understandings about knit stitch based on more varied stitches and physical property tests ultimately to contribute to the development of fashionable designs proper to maximize the usage, function and originality.

  • PDF

Successful Ultrasound-Guided Gastrografin Enema for Very Low Birth Weight Infants with Meconium-Related Ileus

  • Shin, Jaeho;Jeon, Ga Won
    • Neonatal Medicine
    • /
    • v.25 no.1
    • /
    • pp.37-43
    • /
    • 2018
  • Purpose: Meconium-related ileus is common in preterm infants. Without proper management, it can cause necrotizing enterocolitis and perforation requiring emergent operation. This study was conducted to describe the efficacy and safety of ultrasound-guided Gastrografin enema at bedside for preterm infants with meconium-related ileus. Methods: Between March 2013 and December 2014, this study enrolled preterm infants with birth weight <1,500 g, who were diagnosed with meconium-related ileus requiring ultrasound-guided Gastrografin enema refractory to glycerin or warm saline enemas. Gastrografin was infused until it passed the ileocecal valve with ultrasound guidance at bedside. Results: A total of 13 preterm infants were enrolled. Gestational age and birth weight were 28.6 weeks (range, 23.9-34.3 weeks) and 893 g (range, 610-1,440 g), respectively. Gastrografin enema was performed around postnatal day 8 (range, day 3-11). The success rate was 84.6% (11 of 13 cases). Three of these 11 infants received a second procedure, which was successful. Among 2 unsuccessful cases, one failed to pass meconium while the other required surgery due to perforation. The time required to pass meconium was $2.8{\pm}1.5hours$ (range, 1-6 hours). The time until radiographic improvement was $2.8{\pm}3.4days$ (range, 1-14 days) after the procedure. Conclusion: Ultrasound-guided Gastrografin enema at bedside as a first-line treatment to relieve meconium-related ileus was effective and safe for very low birth weight infants. We could avoid unnecessary emergent operation in preterm infants who have high postoperative morbidity and mortality. This could also avoid transporting small preterm infants to fluoroscopy suite.

Assessment of dentists' subjective satisfaction with a newly developed device for maxillary sinus membrane elevation by the crestal approach

  • Kim, Young-Kyun;Cho, Yong-Seok;Yun, Pil-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.6
    • /
    • pp.308-314
    • /
    • 2013
  • Purpose: The purposes of this study were to assess the dentists' subjective satisfaction with the crestal approach sinus (CAS) kit, a device for maxillary sinus membrane elevation by the crestal approach using a special drilling system and hydraulic pressure, and to summarize the subjective satisfaction of dental implants placed after a sinus lift procedure with the CAS kit. Methods: Thirty dental clinicians who had experience with dental implant placement after a sinus lift procedure with the CAS kit from June 2010 to May 2012 were included in this study. The questionnaire for the evaluation of the dentists' subjective satisfaction with the CAS kit was sent to the respondents and returned. The questionnaire was composed of two main parts. The first part was related to the sinus membrane perforation rate. The second part was related to the dentists' subjective satisfaction with the CAS kit. Results: A total of 28 dentists answered the questionnaire. Among 924 implant cases, sinus membrane perforation occurred in 38 cases (4.1%). Among the 28 dentists, 26 dentists (92.9%) were satisfied or very satisfied with the CAS kit. In particular, 24 dentists (85.7%) reported that safety, cutting performance, and user-friendliness of the CAS drill were advantages of the CAS kit. However, 7 dentists (25%) did not routinely use the hydraulic lifter for sinus membrane elevation. Conclusions: From the survey, it was shown that the respondents were generally satisfied with the CAS kit and that the cutting performance and safety of the drill component were considered strengths of the CAS kit.

Collision Performance Improvement in Orthogonal Code Hopping Multiplexing Systems Using Multiple Antennas (다중 안테나를 이용한 직교 부호 도약 다중화 시스템의 성능향상)

  • Jung, Bang-Chul;Lee, Woo-Jae;Park, Yeoun-Sik;Jeon, Seong-Keun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.10
    • /
    • pp.2100-2112
    • /
    • 2011
  • An orthogonal code hopping multiplexing (OCHM) technique has been proposed for accommodating a large number of users with low channel activities than the number of orthogonal codewords through statistical multiplexing in downlink cellular systems. In this paper, a multiple input multiple output (MIMO) antenna based OCHM system is proposed to improve the performance. Each modulated symbol is repeated N times and the N repeated symbols are transmitted simultaneously using N transmit antennas. Through repetitions, the effect of perforations that the OCHM system experiences is decentralized among the repeated symbols and the full perforation probability is significantly reduced. Each receiver detect the transmitted signal using its pre-assigned code hopping pattern. Simulation results show that the proposed scheme saves the required energy for a given frame error rate (FER).

Stomal Complications in Children (소아 장루의 합병증)

  • Park, Joong-Jai;Lee, Joo-Hong;Jung, Jong-Do;Choi, Young-Cheol;Chung, Woo-Shik;Jun, Si-Youl
    • Advances in pediatric surgery
    • /
    • v.8 no.1
    • /
    • pp.11-15
    • /
    • 2002
  • This is a 20 year analysis of the problems associated with enterostomy formation, and closure. Forty-three stomas were established in 43 patients: 23 for anorectal malformations, 11 for Hirschsprung's diseases, 4 for necrotizing enterocolitis, 3 for multiple ileal atresias, 1 for volvulus neonatorum with perforation, and 1 for diaphragmatic hernia with colon perforation. Thirty boys and 13 girls were included (mean age 4.8 months). Stoma complications were encountered in 13 patients (30.2 %): stomal prolapse, stenosis, obstruction, paracolic hernia, retraction, dysfunction, and skin excoriation, Four patients (9.3 %) required stomal revision. Occurrence of complications was not related to age and primary disease, but sigmoid colostomy showed lower complication rate than transverse colostomy (20.0 % vs 42.9 %, p<0.05). There were five deaths but, only one (2.3 %) was directly related to the enterostomy complication. Twenty-one stomas were closed in our hospital and complications occurred in seven patients (33.3 %). The most common complication was wound sepsis in 5 children. In conclusion, because the significant morbidity of stomal formation still exists, refinements of the surgical technique seem to be required, Sigmoid loop colostomy is preferred whenever possible.

  • PDF

Current Status(1994) of Neonatal Surgery in Korea -Survey among the members of Korean Association of Pediatric Surgeons- (1994년도 한국신생아외과의 현황 - 대한소아외과학회 회원대상 전국조사 -)

  • Kim, W.K.;Kim, S.Y.;Kim, S.K.;Kim, I.K.;Kim, J.C.;Park, K.W.;Park, Y.S.;Park, W.H.;Park, J.S.;Song, Y.T.;Oh, S.M.;Lee, D.S.;Lee, M.D.;Lee, S.C.;Chang, S.I.;Chung, E.S.;Jung, P.M.;Joo, J.S.;Choi, S.O.;Huh, Y.S.;Hwang, E.H.
    • Advances in pediatric surgery
    • /
    • v.2 no.1
    • /
    • pp.26-32
    • /
    • 1996
  • To understand the current status of neonatal surgery in Korea, a survey was made among the 27 members of Korean Association of Pediatric Surgeons. Response rate among surgeons was 78 percent, eighteen hospitals participated in this study. Five hundred and three cases of neonatal surgical patients were analyzed. In Korea, about 50% of cases were treated at the hospital in the capital city area. Regional number of patients were closely related to the regional population. Imperforate anus(19%), atresia/stenosis of gut(12%), and Hirschsprung's diseases(12%) were sitting at the top in the list. Majority of operation was done within the first week of life, especially during the first 24 hour period. Eighty per cent was major or so called index cases. Mortality in so-called index cases was 17%. High mortality was observed in patients with diaphragmatic hernia(47%), gastrointestinal perforation(65%) and esophageal atresia(28%). Low birth weight babies showed higher mortality in gastrointestinal perforation, esophageal atresia and abdominal wall defect. These were compared to 1993 survey of Japanese Society of Pediatric Surgeons.

  • PDF

Frequency-Domain Analysis for Motion of Floating Structures with Perforated Wall (유공벽이 설치된 부유체 동요 평가를 위한 주파수 영역 해석)

  • Jeongsoo Kim;Youn Ju Jeong;Young-Taek Kim
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2024
  • As increasing demands for a floating structure expanded from offshore industry facilities to living facilities, it has emerged that necessity of techniques to reduce motions of a floating structure. This study present a floating structure with porosity on the outer surface of the floater. Under each regular and irregular wave, responses of the floater was investigated in frequency domain. The proposed structure is composed of inner and outer floaters, which are connected to each other and the outer wall is perforated, and the heave and the pitch of floaters with different perforation rates (0~30%) were compared with at both the center and the edge. The results showed that pitch responses can be decreased by increasing of perforation rate of the floater. Comparing with responses of the non-perforated floater, those of the proposed floating structure were reduced to above 10% and 2%, respectively for regular and irregular wave conditions.

A Study on the Surgical Hand Scrub and Surgical Glove Perforation (외과적 손씻기 및 외과용 장갑의 천공율에 대한 연구)

  • 윤혜상
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.4
    • /
    • pp.653-667
    • /
    • 1995
  • Post - operative wound infections have been a serious problem in nursing care in the operating room and appear to be strongly related to the infection occurring during the performance of operation. The purpose of this study is to identify patterns in duration of surgical hand scrub (SHS), to evaluate the method of SHS and to examine the rate of glove perforation. Subjects for this study include 244 doctors and 169 nurses working in the operative theatre of a hospital in Seoul area. Test samples and related data were collected from this medical facility between April 1, through 15, and July 1, through 5, 1995 by the author and a staff member working in the operating room. For the study, data on the SHS of doctors and nurses were obtained at the time of operation and multiple batches of surgical gloves worn by the operating doctors were collected after each operation. The duration of SHS was measured with a stop watch and the method of SHS was evaluated according to Scoring Hand Scrub Criteria (SHS Criteria) and expressed as SHS scores. For the analysis of the data, t-test was used to compare the differences in the duration and the SHS scores of doctors and nurses, and Pearson's correlation coefficient was used to examine the relationship between the SHS duration and the SHS scores. The results of the study are summarized as follows. 1) The mean time spent in each SHS was 167 seconds in nurses, and 127 seconds in doctors. The data comparing nurses and doctors indicated that there were significant differences in Our ation of SH S between these two groups (t=5.58, p=.000). 2) The mean time spent in the first SHS was 145 seconds and that in the End SHS, 135 seconds, and there was not a significant difference in the duration of the SHS between doctors and nurses (t=1.44, P=.156). 3) The mean time spent in the SHS by OS (Orthopaedic surgery) doctors was 162 seconds, 150 seconds by NS(Neurologic surgery), 121 seconds by GS(General surgery), 94 seconds by OPH(Opthalmology) and DS(Dental surgery), 82 seconds by URO(Urology), 78 seconds by PS(Plastic surgery) and 40 seconds by ENT(Ear, Nose & Throat) These also showed a significant difference in the duration of the SHS among the medical specialities (t=4.8, P=.0001). 4) The average SHS score of the nurses was 15.2, while that of doctors was 13.1. The statistical analysis showed that t-value was 3.66, p was. 000. This indicates that the nurses actually clean their hands more thoroughly than the doctors do. 5) The average SHS score of NS doctors was 15.5, 15.3 for doctors for OPH,14.3 for OS,12.7 for GS, 12.0 for DS, 11.7 for URO, 10.1 for PS, 7.5 for ENT. Comparison of the average SHS scores from 8 specialties showed that there was a significant differences in the patterns of the SHS (F=5.08, P=.000) among medical specialties. 6) It appears that the operating personnel scrub the palms and dorsum of their hand relatively well, however, less thorough the nails and fingers. 7) The more the operating personnel spend their time in hand scrubbing, the more correctly they clean their hands(r=.6427, P<.001). 8) The overall frequencies of perforation in all post-operative gloves tested was 38 out of 389 gloves (10.3%). The perforation rate for PS was 13%, 12.1% for GS,8.8% for 05, and 3.3% for NS.

  • PDF

Making Method of Deterioration Map and Evaluation Techniques of Surface and Three-dimensional Deterioration Rate for Stone Cultural Heritage (석조문화유산의 손상지도 제작방법과 표면 및 3차원 손상율 평가기법)

  • Jo, Young-Hoon;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.27 no.3
    • /
    • pp.251-260
    • /
    • 2011
  • This study focus on the suggestion of standard legend, the process system on making method of deterioration map, the development of crack index (CI), and the evaluation techniques of surface and 3D deterioration rate for stone cultural heritage. The standard legends of deterioration forms were made using a common graphic program after crack, blistering, scaling, break-out, granular disintegration, and perforation were subdivided. The deterioration map improved accuracy and reliability on deterioration range using 3D digital restoration and high resolution photograph mapping technique. Also, quantitative deterioration evaluation of stone cultural heritage was carried out developing the crack index, and the 3D deterioration rate of a break-out part was calculated by virtual restoration modeling. As a quantitative deterioration evaluation of Magoksa Temple stone pagoda based on the results described above, the north face showed high deterioration rate of bursting crack (1.70), hair crack (1.34), scaling (20.2%) and break out (13.0%), and the 3D deterioration rate of first roof stone was 6.7%.

Characteristics of high performance reinforced concrete barriers that resist non-deforming projectile impact

  • Dancygier, A.N.
    • Structural Engineering and Mechanics
    • /
    • v.32 no.5
    • /
    • pp.685-699
    • /
    • 2009
  • Current research and development of high performance concrete, together with study of phenomena that are pertinent to impact resistance, have lead to a new generation of barriers with improved properties to resist impact loads. The paper reviews major properties and mechanisms that affect impact resistance of concrete barriers as per criteria that characterize the resistance. These criteria are the perforation limit, penetration depth and the amount of front and rear face damage. From the long-known, single strength parameter that used to represent the barriers' impact resistance, more of the concrete mix ingredients are now considered to be effective in determining it. It is shown that the size and hardness of the aggregates, use of steel fibers and micro-silica have different effects on performance under impact and on the resistance. Additional pertinent phenomena, such as the rate and size effects, confinement and local versus global response, are pointed out with their reference to possible future developments in the design of impact resisting concrete barriers.