• Title/Summary/Keyword: Perfluorocarbon

Search Result 21, Processing Time 0.025 seconds

Determination of Atmospheric Perfluorocarbon Background Concentration of fL/L Range in Korea (국내 대기 중 fL/L 농도의 perfluorocarbon 배경농도 측정)

  • 예선경;김혜경;노철언;이종범;이강웅;한진석
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.305-306
    • /
    • 2001
  • 동북아시아 지역은 대기오염물질의 장거리 이동과 관련하여 많은 관심이 집중되고 있는 지역이다. 특히 중국은 급속한 산업화로 인해 많은 양의 대기오염 물질을 배출하고 있으며, 배출된 대기오염물질이 장거리를 이동하면서 특히 중국의 풍하지역에 놓이는 경우가 많은 우리나라에 피해를 줄 가능성이 크나 이에 대한 증거 자료가 미흡한 실정이다. 따라서 우리나라 서해안 지역에 대한 오염물질의 이류 특성을 파악할 필요가 있다. (중략)

  • PDF

Characteristics of a Bioreactor Using Perfluorocarbons and a New Impeller (과불소탄소화물과 새로운 임펠러를 사용한 생물반응기의 특성)

  • 조무환;김용락정재학김정목
    • KSBB Journal
    • /
    • v.6 no.3
    • /
    • pp.231-240
    • /
    • 1991
  • Recently, developments of large scale and high density cell culture methods have been the objects of many researches, because the demand of various pharmaceutical products produced by animal cell culture has been rapidly increasing. The cell culture equipment should have the requirements such as sufficient oxygen transfer and mixing, low shear stress and surface tension, and small foaming. In order to develop a proper bioreactor meeting these requirements simultaneously, a perfluorocarbon having high solubility of oxygen was sprayed into the medium as an oxygen carrier instead of air. Also, a new impeller was developed and combined together with the perfluorocarbon spraying system so as to design a new bioreartor for cell cultivation. The new impeller had better characteristics of mixing and oxygen transfer than the paddle and cell-lift impellers based on the same, shear rate. But, it was observed that the volumetric oxygen transfer coefficient of the new bioreactor decreased with increasing cell density during E. coli fermentation.

  • PDF

A study on heat transport limitation for a perfluorocarbon heat pipe (PFC 히트파이프의 열전달 한계에 관한 연구)

  • 강환국;김재진;김철주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.313-320
    • /
    • 1999
  • A PFC(Perfluorocarbon) heat pipe has been used recently for cooling of GTO(gate turn off) thyristors or diodes in electric commuter trains. The present study was conducted to determine heat transport limitation of a PFC heat pipe which is one of the important parameters in heat pipes design. The variables such as tube diameter, fill charge ratio, internal surface structure and operating temperature were examined by way of experiment. Experimental data showed that the heat transport limitation of PFC heat pipe was considerably low and mostly dependent on tube diameter, with the value of 440~500W for d$o$/=22.23mm and 150~200W for d$o$=15.88mm. The other parameters had negligible effects, except for the case of small charge ratio less than 30%. Some correlations proposed by previous studies were in agreement with data from this study within 10~30%.

  • PDF

A Study on Heat Transfer Coefficient of a Perfluorocarbon Heat Pipe (Perfluorocarbon 히트파이프의 열전달 계수에 관한 연구)

  • 강환국;김철주;김재진
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.194-201
    • /
    • 1998
  • In electric commuter trains using AC motors, lots of GTO thyristors and diodes are needed for power controls. These semiconductors generate heat about 1~2 kW, and for cooling which perfluorocarbon(PFC) heat pipes have been in use for the last two decades. The present study was investigated on the effects of such important design parameters as structure of internal surface (grooved or smooth), fill charge ratio, and inclinating angle from a vertical on heat transfer coefficients at both evaporators and condensers. To obtain experimental data, several heat pipes of the same geometry of 520 mm long and diameter of 15.88 mm but different in fill charge ratio and internal surface structure were designed and fabricated. For prediction of the heat transfer coefficients, related expressions were examined and the results of calculations were compared with experimental data. Performance tests were conducted while heat pipes operated at mode of thermosyphons. High enhancements of heat transfer coefficient were obtained internal grooves. In these cases, the evaporating heat transfer coefficients distributed in the range of 2~5.5 kW/$m^2$K, with an increase of heat flux from 15~45 kW/$m^2$. These experimental data were in good agreement with Rohsenow's expression based on nucleate boiling when correction factor $C_R$=1.3 was encountered. In addition, the condensation heat transfer coefficients were distributed from 1.5 to 3.5 kW/$m^2$K, and the data were in good agreements with Nusselt's correlation, based on filmwise condensation on vertical plate, when choosing a correction factor $C_N=4$. A fill charge ratio of 40~100% were recommended, and the in clination angle effects were negligible when the angle was higher then 30$^{\circ}$.

  • PDF

Evaluation of INPUFF Model Using METREX Tracer Diffusion Experiment Data (METREX 확산실험 자료를 이용한 INPUFF모델의 평가)

  • 이종범;송은영;황윤성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.437-452
    • /
    • 2002
  • The Metropolitan Tracer Experiment (METREX) was performed over the Washington, D.C. area using two inert, non-deposition perfluorocarbon gases for over 1 year period (November 1983∼December 1984). Two perfluorocarbon gas tracers (PDCH, PMCH) were released simultaneously at intervals of every 36 hours for 6 hours, regardless of the meteorological conditions in metropolitan area. Samples were collected continuously for 8 hours at a central downtown and two adjacent suburban locations. Monthly air samples were collected at 93 sites across the whole region (at urban, suburban, and rural locations). The purpose of this study is to simulate INPUFF and ISCST model using METREX data, and to compare calculated and observed concentrations. In the case of INPUFF simulation, two meteorological input data were used. One is result data from wind field model which was calculated by diagnostic wind model (DWM), the other is meteorological data observed at single station. Here, three kinds of model calculation were performed during April and July 1984; they include (1) INPUFF model using DWM data (2) INPUFF model using single meteorological data (3) ISCST model. The monthly average concentration data were used for statistic analysis and to draw their horizontal distribution patterns. Eight-hour-averaged concentration was used to describe movement of puff during the episode period. The results showed that the concentrations calculated by puff model (INPUFF) were better than plume model (ISCST). In the case of puff model (INPUFF), a model run using wind field data produced better results than that derived by single meteorological data.

Determination of Atmospheric Perfluorocarbon Background Concentrations of fL/L Range at the Western Coastal Area of Korea

  • Kim, Hye-Kyeong;Yea, Sun-Kyung;Ro, Chul-Un;Lee, Chong-Bum;Jang, Meong-Do;Lee, Gang-Woong;Yoo, Eun-Jin;Han, Jin-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.2
    • /
    • pp.301-308
    • /
    • 2002
  • As part of perfluorocarbon (PFC) tracer release experiment conducted at the western coastal area of Korea in February 2001, the background concentration level of perfluorocarbons (PFCs) in the atmosphere was determined by gas chromatography with electron capture detector. Prior to the PFC tracer release experiment in the field, air samples were collected using active samplers and the background concentrations of PFCs were determined. The concentrations of perfluoromethylcyclohexane ($C_7F_{14}$, PMCH) in the western coastal area of Korea were in the range of 5.8-8.7 fL/L. The mean concentration of the PMCH in the region exhibited no significant spatial and temporal variations. This concentration level is somewhat higher and has larger standard deviation than those of studies previously conducted in USA and Europe on the background concentration levels of PFCs. Because the background concentration of PMCH in Korea is still very low and consistent temporally and spatially, the PMCH tracer can be used suitably for the studies of long-range atmospheric transport.

Perfluorocarbon Does Not Inhibit Chemokine Expression in Airway Epithelial Cells (Perfluorocarbon이 기도 상피세포 Chemokine 발현에 미치는 영향에 관한 연구)

  • Suh, Gee-Young;Kang, Kyeong-Woo;Park, Sang-Joon;Chung, Man-Pyo;Kim, Ho-Joong;Choi, Dong-Chull;Rhee, Chong-H;Kwon, O-Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.2
    • /
    • pp.223-235
    • /
    • 2000
  • Background: Liquid ventilation is associated with decreased inflammatory response in an injured lung. This study was performed to investigate if whether perfluorocarbon(PFC) can decrease chemokine expression in airway epithelial cells. Methods: A549 cells were used for airway epithelial cells and perfluorodecalin for PFC. To expose cells to PFC, lower chamber of Transwell$^{(R)}$plate was used. This study was performed in two parts. In the first part, we examined whether PFC could decrease chemokine expression in airway epithelial cells through inhibition of other inflammatory cells. Peripheral blood mononuclear cells(PBMC's) were isolated and stimulated with lipopolysaccharide(LPS, 10 ${\mu}g/mL$) for 24 hours with or without exposure to PFC. Then A549 cells were stimulated with conditioned media(CM) containing the culture supernatants of PBMC. After 24 hours, the expressions of interleukin-8(IL-8) and RANTES were measured. In the second part of the study, we studied whether PFC could directly suppress chemokine expression in airway epithelial cells. A549 cells were stimulated for 24 hours with interleukin-l$\beta$ and/or tumor necrosis factor-$\alpha$ with or without exposure to PFC, and then the chemokine expression was measured. Northern analysis was used to measure the mRNA expression, and ELISA was used for immunoreactive protein measurements in culture supernatant. Results: 1. IL-8 and RANTES mRNA expression and immunoreactive protein production were increased significantly by CM from LPS-stimulated PBMC in A459 cells compared to with CM from unstimulated PBCM (p<0.05), but exposure of PFC had no significant effect on either mRNA expression or immunoreactive protein expression. 2. IL-8 and RANTES mRNA expression and immunoreactive protein production were increased significantly by IL-1$\beta$ and TNF-$\alpha$ in A549 cells(p<0.05), but exposure of PFC had no significant effect on neither either mRNA expression nor immunoreactive protein production. Conclusion : Decreased chemokine expression of airway epithelial cells may not be involved in decreased inflammatory response observed in liquid ventilation. Further studies on possible mechanisms of decreased inflammatory response are warranted.

  • PDF

Enhancement of Oxygen Transfer in Animal Cell Culture by Using a Perfluorocarbon as an Oxygen Carrier (과불소 탄소화물을 산소전달매체로서 사용하여 동물세포 배양의 산소전달 증진)

  • 조무환
    • KSBB Journal
    • /
    • v.4 no.1
    • /
    • pp.1-7
    • /
    • 1989
  • In order to increase the oxygen transfer in a bioreactor for animal cell culture, a penluorocarbon, $Flutec^R$ ppll was used in a modified Celligen $Celligem^{TM}$. Also, the effects of ppll on the hybridoma cell growth and on the production of monoclonal antibody were investigated. There was no harmful effect of ppl1 on the cell growth and on the production of monoclonal antibody.

  • PDF

A Study on Heat Transfer Coefficient of a Perflourocarbon Heat Pipe (Perfluorocarbon 히트파이프의 열전달 계수에 관한 연구)

  • 강환국;김철주;이진성;김재진
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1998.05a
    • /
    • pp.95-103
    • /
    • 1998
  • 오늘날 전기 철도 차량의 속도제어방식에는 A.C모터의 속도를 제어하는 방식을 많이 사용하고 있고 이 경우 여러 개의 GTO thyristor와 다이오드가 필요하다. 그런데 이러한 반도체 소자들은 전기 부하의 일부를 저항열로 소모하며 반도체의 용량에 따라 차이가 있으나 전기 철도 차량의 경우 약 1~2㎾의 열이 발생한다. 따라서 이들 소자들이 적정온도범위(100~12$0^{\circ}C$미만)를 유지하기 위해서는 소자의 내부저항열을 외부로 방출시켜야 한다. 지난 30여 년 동안 이러한 반도체 소자 냉각에는 강제대류, 침적 비등, 히트파이프식 냉각방법이 적용되어 왔다. 최근에는 히트파이프식 냉각방법이 유지보수, 크기 및 중량 등 여러 측면에서 상대적으로 유리하기 때문에 히트파이프식 냉각방법을 주로 사용하고 있다. (중략)

  • PDF

Separation and Extraction of Hot Particulate from contaminated Perfluorocarbon solution

  • Kim Gye-Nam;Narayan Mathuresh;Wou Hui-Jun;Jung Chong-Hun;Oh Won-Zin
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.70-71
    • /
    • 2005
  • It was an idea to develop a system to remove the contaminated hot particulate to make clean nuclear research facilities to the clear visibility for researcher. In order to clean micron and sub micron size particulates from used PFC solution as a decontamination tool. Since PFC solution is very expensive so it was a high recommendation to develop the some filtration equipment to purify PFC for next decontamination process, in additionally, reduce the secondary waste. However, we developed an easy and economic filter system to purify the PFC solution. The major advantage of the process operates in closed loop under near ambient conditions, thus minimizing the potential for fugitive TRU emissions and reduces the secondary waste. This has very significant safety and cost impacts. Here we proposed the two types PFC filter systems.

  • PDF