• 제목/요약/키워드: Percutaneous access

검색결과 32건 처리시간 0.022초

Percutaneous Enteral Stent Placement Using a Transhepatic Access for Palliation of Malignant Bowel Obstruction after Surgery

  • Won Seok Choi;Chang Jin Yoon;Jae Hwan Lee
    • Korean Journal of Radiology
    • /
    • 제22권5호
    • /
    • pp.742-750
    • /
    • 2021
  • Objective: To assess the safety and clinical efficacy of percutaneous transhepatic enteral stent placement for recurrent malignant obstruction in patients with surgically altered bowel anatomy. Materials and Methods: Between July 2009 and May 2019, 36 patients (27 men and 9 women; mean age, 62.7 ± 12.0 years) underwent percutaneous transhepatic stent placement for recurrent malignant bowel obstruction after surgery. In all patients, conventional endoscopic peroral stent placement failed due to altered bowel anatomy. The stent was placed with a transhepatic approach for an afferent loop obstruction (n = 27) with a combined transhepatic and peroral approach for simultaneous stent placement in afferent and efferent loop obstruction (n = 9). Technical and clinical success, complications, stent patency, and patient survival were retrospectively evaluated. Results: The stent placement was technically successful in all patients. Clinical success was achieved in 30 patients (83.3%). Three patients required re-intervention (balloon dilatation [n = 1] and additional stent placement [n = 2] for insufficient stent expansion). Major complications included transhepatic access-related perihepatic biloma (n = 2), hepatic artery bleeding (n = 2), bowel perforation (n = 1), and sepsis (n = 1). The 3- and 12-months stent patency and patient survival rates were 91.2%, 66.5% and 78.9%, 47.9%, respectively. Conclusion: Percutaneous enteral stent placement using transhepatic access for recurrent malignant obstruction in patients with surgically altered bowel anatomy is safe and clinically efficacious. Transhepatic access is a good alternative route for afferent loop obstruction and can be combined with a peroral approach for simultaneous afferent and efferent loop obstruction.

Percutaneous femoral access: Stuck guide wire, decannulation difficulty due to unravelling and knotting

  • Bhanu Pratap Singh Chauhan;Binita Dholakia;Ashfaque Khan;Chirag Hirani;Satheesh Kumar;Dibya Jyoti Mahakul;Abhishek Katyal;Wajid Nazir;Daljit Singh
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • 제26권2호
    • /
    • pp.223-226
    • /
    • 2024
  • Percutaneous techniques for femoral arterial access are increasingly being performed due to advances in endovascular cerebral procedures, as they provide a less morbid and minimally invasive approach than open procedures. Common complications associated with this peripheral puncture include hematoma, bleeding, pseudoaneurysm, arteriovenous fistula, retroperitoneal bleeding, inadvertent venous puncture, dissection, etc. The retrograde femoral access is currently the most frequently used arterial access as it is technically straightforward, allows for the use of larger size sheaths and catheters, allows repeated attempts, etc. Although being technically less challenging, grave complications can occur due to hardware failure. Here, we present a case of unruptured posterior inferior cerebellar artery (PICA) aneurysm, who underwent uneventful diagnostic cerebral digital substraction angiography (DSA) via right femoral artery route on first attempt, but on second attempt for therapeutic intervention, landed up with stuck guide wire and faced decannulation difficulty due to unravelling of guide wire and multiple knot formation, which was finally removed after multiple attempts at pulling and improvised manoeuvres. Such cannulation and decannulation difficulties have been reported multiple times for central venous access, but extremely rarely for femoral routes, making this case a rarity and worth reporting.

Update on Transradial Access for Percutaneous Transcatheter Visceral Artery Embolization

  • Hee Ho Chu;Jong Woo Kim;Ji Hoon Shin;Soo Buem Cho
    • Korean Journal of Radiology
    • /
    • 제22권1호
    • /
    • pp.72-85
    • /
    • 2021
  • Transfemoral access (TFA) is a widely used first-line approach for most peripheral vascular interventions. Since its introduction in cardiologic and neurointerventional procedures, several advantages of transradial access (TRA) over TFA have been demonstrated, such as patient preference, lower complication rates, early ambulation, and shorter hospital stay. However, studies reporting the safety and efficacy of this approach for peripheral vascular interventions performed by interventional radiologists are relatively few. This review aimed to summarize the technique and clinical applications of TRA in percutaneous transcatheter visceral artery embolization and the management of complications.

Feasibility of Percutaneous Pancreatic Stent Placement in Postoperative Pancreaticojejunostomy Stenosis

  • Juil Park;Kichang Han;Joon Ho Kwon;Man-Deuk Kim;Jong Yun Won;Sungmo Moon;Gyoung Min Kim
    • Korean Journal of Radiology
    • /
    • 제24권12호
    • /
    • pp.1241-1248
    • /
    • 2023
  • Objective: To evaluate the role of percutaneous pancreatic stent placement in postoperative pancreaticojejunostomy stenosis (PJS). Materials and Methods: This retrospective single-center study included seven procedures in five patients (four males and one female; median age, 63 years) who underwent percutaneous pancreatic stent placement for postoperative PJS between January 2005 and December 2021. The patients were referred to interventional radiology because of unfavorable anatomy or bowel abnormalities. The pancreatic duct was accessed under ultrasound and/or computed tomography guidance. A stent was placed after balloon dilatation of the PJS. Moreover, plastic stents were placed for the first two procedures, whereas bare-metal stents were used for the remaining five procedures. Technical success was defined as the successful placement of stents for the PJS, meanwhile, clinical success was defined as the normalization of pancreatic enzymes without recurrence of pancreatitis. Results: Pancreatic duct access and stent placement were successfully performed in all patients (technical success rate: 100%). All the procedures initially yielded clinical success. However, recurrence of pancreatitis was observed after two procedures that used plastic stents because of stent migration at 0.3 and 3 months after the procedure. In contrast, no instances of recurrent pancreatitis were noted after metal stent placement for a follow-up duration of 1-36 months. No serious procedure-related adverse events were observed. Conclusion: Percutaneous pancreatic stent placement may be a viable option for patients with postoperative PJS in whom an endoscopic approach is not feasible. Metal stents may be considered over plastic stents for the management of PJS, considering the possible lower stent migration and infeasibility of frequent endoscopic stent exchange due to the altered anatomy.

Current treatment status and medical costs for hemodialysis vascular access based on analysis of the Korean Health Insurance Database

  • Lee, Hyung Seok;Ju, Young-Su;Song, Young Rim;Kim, Jwa Kyung;Choi, Sun Ryoung;Joo, Narae;Kim, Hyung Jik;Park, Pyoungju;Kim, Sung Gyun
    • The Korean journal of internal medicine
    • /
    • 제33권6호
    • /
    • pp.1160-1168
    • /
    • 2018
  • Background/Aims: The Republic of Korea is a country where the hemodialysis population is growing rapidly. It is believed that the numbers of treatments related to vascular access-related complications are also increasing. This study investigated the current status of treatment and medical expenses for vascular access in Korean patients on hemodialysis. Methods: This was a descriptive observational study. We inspected the insurance claims of patients with chronic kidney disease who underwent hemodialysis between January 2008 and December 2016. We calculated descriptive statistics of the frequencies and medical expenses of procedures for vascular access. Results: The national medical expenses for access-related treatment were 7.12 billion KRW (equivalent to 6.36 million USD) in 2008, and these expenses increased to 42.12 billion KRW (equivalent to 37.67 million USD) in 2016. The population of hemodialysis patients, the annual frequency of access-related procedures, and the total medical cost for access-related procedures increased by 1.6-, 2.6-, and 5.9-fold, respectively, over the past 9 years. The frequency and costs of access care increased as the number of patients on hemodialysis increased. The increase in vascular access-related costs has largely been driven by increased numbers of percutaneous angioplasty. Conclusions: The increasing proportion of medical costs for percutaneous angioplasty represents a challenge in the management of end-stage renal disease in Korea. It is essential to identify the clinical and physiological aspects as well as anatomical abnormalities before planning angioplasty. A timely surgical correction could be a viable option to control the rapid growth of access-related medical expenses.

요추 추간판 탈출증에서 Dekompressor(R)를 이용한 경피적 수핵 감압술 (Percutaneous Discectomy of Herniated Intervertebral Disc with a Dekompressor(R))

  • 조외경;김찬;한경림;이현호;조혜원
    • The Korean Journal of Pain
    • /
    • 제18권2호
    • /
    • pp.192-197
    • /
    • 2005
  • Background: Radicular pain, associated with herniated intervertebral disc, has been treated with either conservative treatments or a traditional surgical discectomy. Several modalities for minimally invasive percutaneous procedures have been developed as alternatives to a surgical discectomy. Percutaneous decompression using a $Dekompressor^{(R)}$ probe has been recently introduced. Herein, we report the outcome of percutaneous decompression with a $Dekompressor^{(R)}$ for the treatment of a herniated intervertebral disc. Methods: Between August 2004 and April 2005, percutaneous decompression was performed using a $Dekompressor^{(R)}$, 1.5-mm percutaneous lumbar discectomy probe in 17 patients with a herniated lumbar intervertebral disc resistant to conservative treatments, with the results reviewed retrospectively. The procedure was performed under fluoroscopic guidance after local anesthesia. Disc access was gained with a posterolateral approach on the symptomatic side and intradiscal placement of the discectomy probe in the herniated disc confirmed from the anteroposterior and lateral views on the fluoroscopy. Results: We obtained satisfactory clinical results in 14 patients with a decrease in the initial Visual analogue scale (VAS) of more than 55% and the elimination or reduction of analgesic medication, with a follow-up of 3 to 11 months. Conclusion: We concluded that a percutaneous discectomy with a $Dekompressor^{(R)}$ probe might be an effective alternative for the treatments of painful disc herniations resistant to conservative managements when performed under proper selection criteria.

동정맥루 기능 부전에서 경피적 혈관성형술 후 발생한 정맥 파열의 유병률 및 관리: 파열되지 않은 혈관과의 일차 개통 비교 연구 (Prevalence and Management of Venous Rupture Following Percutaneous Transluminal Angioplasty in Dysfunctional Arteriovenous Access: A Comparative Study of Primary Patency Rates with Non-Ruptured Access Circuits)

  • 박윤수;양승부;강채훈;구동억
    • 대한영상의학회지
    • /
    • 제85권4호
    • /
    • pp.746-753
    • /
    • 2024
  • 목적 본 연구는 기능 부전의 동정맥루에 대한 경피적 혈관성형술 후 발생한 정맥 파열의 유병률 및 관리에 대하여 다루고자 하였다. 대상과 방법 1998년 1월부터 2015년 12월까지, 6732명의 환자(여성 3685명, 남성 3047명, 평균 나이 58.60 ± 12.84세; 평균 혈액투석 접근 시기: 34.32 ± 39.35개월)에 대하여 시행된 13506건의 경피적 혈관성형술, 기계적 혈전제거술, 그리고 혈전용해술이 검토되었다. 경피적 혈관성형술 후 정맥 혈관이 파열된 비율을 확인하였고 일차 개통은 시술 후 정맥 혈관의 파열된 상태, 혈전의 존재 유무, 치료 방법에 따라 결정되었다. 결과 정맥 파열은 13506건의 시술 중 604건에서 발생했다. 정맥 혈관 파열은 여성, 동정맥 이식, 그리고 혈전이 동반되었을 경우 호발하였다. 풍선 탐포네이드는 604건의 파열 사례에서 시행되었고 스텐트 시술은 조영제 유출과 혈류 정체가 지속되었을 때, 119건에서 시행되었다. 일차 개통은 파열군보다 비파열군에서 더 우수하게 나타났다. 그러나, 접근 유형과 혈전의 존재 유무는 개통 측면에서 유의한 차이가 없었다. 파열 환자의 일차 개통 시간은 지속적인 풍선 탐포네이드 후 8.4개월 이였고 스텐트 시술 후 11.2개월이었다. 결론 풍선 탐포네이드와 비피막형 스텐트 설치는 경피적 혈관성형술 관련 정맥 파열에서 적용될 수 있는 치료 방법이다. 특히, 스텐트 설치는 비파열군과 유사한 개통 시간을 보여주었다.

Vertebroplasty Utilizing Percutaneous Vertebral Body Access (PVBA) Technique for Osteoporotic Vertebral Compression Fractures in the Middle Thoracic Vertebrae

  • Cho, Yong-Jun;Choi, Jong-Hun;Cho, Sung-Min
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권3호
    • /
    • pp.161-165
    • /
    • 2007
  • Objective : Percutaneous approach to the middle thoracic vertebra through the transpedicular route for the patients with osteoporotic vertebral compression fractures is difficult due to the small size of the pedicle and parasagittally oriented vertebra body anatomy. The percutaneous vertebral body access [PVBA] technique utilizing the posterolateral extrapedicular approach avoids the pedicle and provides direct access to the vertebral body. The objective of this study is to evaluate the efficacy of the vertebroplasty utilizing PVBA technique for osteoporotic vertebral compression fractures in the middle thoracic vertebrae. Methods : A retrospective review was done on 20 patients who underwent vertebroplasty utilizing PVBA technique performed for painful osteoporotic compression fracture in the middle thoracic vertebrae at 22 levels from May 2003 to June 2006. The average amount of the injected cement was 1.5-2.5ml. The postprocedural outcome was assessed using a visual analogue scale [VAS]. Results : The treated vertebrae were T5 [1 level], T6 [5 levels], 17 [7 levels], and T8 [9 levels]. The compression rate and kyphotic angle were improved after procedure from $18%{\pm}13.4$ to $16%{\pm}13.8$ [p > 0.05] and from $6.9^{\circ}{\pm}6.7$ to $6.6^{\circ}{\pm}6.2$ [p>005], respectively. Preprocedural VAS was $8.2{\pm}0.70$ and was decreased to $2.1{\pm}1.02$ [p < 0.01] after treatment. Postprocedural cement leakage was noted in 3 levels [13.7%]. There were no cases of leakage to epidural space or neural foramen, segmental artery injury, and pneumothorax. Conclusion : These results suggest that the complication rates are low and good results can be achieved with vertebroplasty utilizing PVBA technique for the osteoporotic vertebral compression fractures especially in the middle thoracic vertebrae.

Safety of a Totally Implantable Central Venous Port System with Percutaneous Subclavian Vein Access

  • Keum, Dong-Yoon;Kim, Jae-Bum;Chae, Min-Cheol
    • Journal of Chest Surgery
    • /
    • 제46권3호
    • /
    • pp.202-207
    • /
    • 2013
  • Background: The role of totally implantable central venous port (TICVP) system is increasing. Implantation performed by radiologist with ultrasound-guided access of vein and fluoroscope-guided positioning of catheter is widely accepted nowadays. In this article, we summarized our experience of TICVP system by surgeon and present the success and complication rate of this surgical method. Materials and Methods: Between March 2009 and December 2010, 245 ports were implanted in 242 patients by surgeon. These procedures were performed with one small skin incision and subcutaneous puncture of subclavian vein. Patient's profiles, indications of port system, early and delayed complications, and implanted period were evaluated. Results: There were 82 men and 160 women with mean age of 55.74. Port system was implanted on right chest in 203, and left chest in 42 patients. There was no intraoperative complication. Early complications occurred in 11 patients (4.49%) including malposition of catheter tip in 6, malfunction of catheter in 3, and port site infection in 2. Late complication occurred in 12 patients (4.90%). Conclusion: Surgical insertion of TICVP system with percutaneous subclavian venous access is safe procedures with lower complications. Careful insertion of system and skilled management would decrease complication incidence.

The Obturator Guiding Technique in Percutaneous Endoscopic Lumbar Discectomy

  • Han, In-Ho;Choi, Byung-Kwan;Cho, Won-Ho;Nam, Kyoung-Hyup
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권3호
    • /
    • pp.182-186
    • /
    • 2012
  • In conventional percutaneous disc surgery, introducing instruments into disc space starts by inserting a guide needle into the triangular working zone. However, landing the guide needle tip on the annular window is a challenging step in endoscopic discectomy. Surgeons tend to repeat the needling procedure to reach an optimal position on the annular target. Obturator guiding technique is a modification of standard endoscopic lumbar discectomy, in which, obturator is used to access triangular working zone instead of a guide needle. Obturator guiding technique provides more vivid feedback and easy manipulation. This technique decreases the steps of inserting instruments and takes safer route from the peritoneum.