Vertebroplasty Utilizing Percutaneous Vertebral Body Access (PVBA) Technique for Osteoporotic Vertebral Compression Fractures in the Middle Thoracic Vertebrae

  • Cho, Yong-Jun (Department of Neurosurgery, Chunchon Sacred Heart Hospital, College of Medicine, Hallym University) ;
  • Choi, Jong-Hun (Department of Neurosurgery, Chunchon Sacred Heart Hospital, College of Medicine, Hallym University) ;
  • Cho, Sung-Min (Department of Neurosurgery, Chunchon Sacred Heart Hospital, College of Medicine, Hallym University)
  • Published : 2007.03.30

Abstract

Objective : Percutaneous approach to the middle thoracic vertebra through the transpedicular route for the patients with osteoporotic vertebral compression fractures is difficult due to the small size of the pedicle and parasagittally oriented vertebra body anatomy. The percutaneous vertebral body access [PVBA] technique utilizing the posterolateral extrapedicular approach avoids the pedicle and provides direct access to the vertebral body. The objective of this study is to evaluate the efficacy of the vertebroplasty utilizing PVBA technique for osteoporotic vertebral compression fractures in the middle thoracic vertebrae. Methods : A retrospective review was done on 20 patients who underwent vertebroplasty utilizing PVBA technique performed for painful osteoporotic compression fracture in the middle thoracic vertebrae at 22 levels from May 2003 to June 2006. The average amount of the injected cement was 1.5-2.5ml. The postprocedural outcome was assessed using a visual analogue scale [VAS]. Results : The treated vertebrae were T5 [1 level], T6 [5 levels], 17 [7 levels], and T8 [9 levels]. The compression rate and kyphotic angle were improved after procedure from $18%{\pm}13.4$ to $16%{\pm}13.8$ [p > 0.05] and from $6.9^{\circ}{\pm}6.7$ to $6.6^{\circ}{\pm}6.2$ [p>005], respectively. Preprocedural VAS was $8.2{\pm}0.70$ and was decreased to $2.1{\pm}1.02$ [p < 0.01] after treatment. Postprocedural cement leakage was noted in 3 levels [13.7%]. There were no cases of leakage to epidural space or neural foramen, segmental artery injury, and pneumothorax. Conclusion : These results suggest that the complication rates are low and good results can be achieved with vertebroplasty utilizing PVBA technique for the osteoporotic vertebral compression fractures especially in the middle thoracic vertebrae.

Keywords

References

  1. Barr JD, Barr MS, Lemley TJ, McCann RM : Percutaneous vertebroplasty for pain relief and spinal stabilization. Spine 25 : 923-928, 2000 https://doi.org/10.1097/00007632-200004150-00005
  2. Bostrom MPG, Lane JM : Future directions: augmentation of osteoporotic vertebral bodies. Spine (Supple) 22 : 38-42, 1997 https://doi.org/10.1097/00007632-199701010-00007
  3. Cotten A, Dewatre F, Cortet B, Assaker R, Leblond D, Duquesnoy B, et al : Percutaneous vertebroplasty for osteolytic metastases and myeloma : effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up. Radiology 200 : 525-530, 1996 https://doi.org/10.1148/radiology.200.2.8685351
  4. Dean JR, Ison KT, Gishen P : The strengthening effect of percutaneous vertebroplasty. Clin Radiol 55 : 471-476, 2000 https://doi.org/10.1053/crad.2000.0478
  5. Deramond H, Wright NT, Belkoff SM : Temperature elevation caused by bone cement polymerization during vertebroplasty. Bone 25 : 17S- 25S, 1999 https://doi.org/10.1016/S8756-3282(99)00127-1
  6. Diamond TH, Champion B, Clark WA : Management of acute osteoporotic vertebral fractures : a nonrandomized trial comparing percutaneous vertebroplasty with conservative therapy. Am J Med 114 : 257-265, 2003 https://doi.org/10.1016/S0002-9343(02)01524-3
  7. Do HW, Kwon YJ, Yang JY, Choi CS, Ju MB : The analysis of polymethylmethacrylate leakage after vertebroplasty for vertebral body compression fractures. J Korean Neurosurg Soc 35 : 478-482, 2004
  8. Ferguson RL, Tencer AF, Woodard P, Allen BL Jr : Biomechanical comparisons of spinal fracture models and the stabilizing effects of posterior instrumentations. Spine 13 : 453-460, 1988 https://doi.org/10.1097/00007632-198805000-00003
  9. Grados F, Depriester C, Cayrolle G, Hardy N, Deramond H, Fardellone P : Long-term observation of vertebral osteoporotic fractures treated by percutaneous vertebroplasty. Rheumatology 39 : 1410-1414, 2000 https://doi.org/10.1093/rheumatology/39.12.1410
  10. Hide IG, Gangi A : Percutaneous vertebroplasty : history, technique and current perspective. Clin Radiol 59 : 461-467, 2004 https://doi.org/10.1016/j.crad.2004.01.001
  11. Jensen ME, Evans AJ, Mathis JM, Kallmes DF, Cloft HJ, Dion JE : Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures : technical aspects. AJNR Am J Neuroradiol 18 : 1897-1904, 1997
  12. Kang JH, Kuh SU, Shin ZZ, Cho YE, Yoon YS, Chin DK : The effectiveness of osteoplasty system (vertebroplasty using large cannula-low pressure delivery system) in compression fracture and other spinal pathology. J Korean Neurosurg Soc 38 : 259-264, 2005
  13. Komemushi A, Kariya TS, Kojima KH, Shomura Y, Sawada S : Percutaneous vertebroplasty for compression fracture : analysis of vertebral body volume by CT volumetry. Acta Radiologica 46 : 276-279, 2005 https://doi.org/10.1080/02841850510016072
  14. Kornblatt MD, Casey MP, Jacobs RR : Internal fixation in lumbosacral spine fusion. A biomechanical and clinical study. Clin Orthop Relat Res : 141-150, 1986
  15. Lee JU, Ryu KS, Park CK, Choi YK, Park CK, Ji C, et al : Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic thoracic and lumbar vertebral body compression fractures : outcome of 159 patients. J Koren Neurosurg Soc 30 : 173-179, 2001
  16. Lee KS, Cho YJ, Choi JH, Cho SM, Ryu KS, Ahn MS : A small amount of bone cement injected vertebroplasty utilizing percutaneous vertebral body access technique for osteoporotic vertebral fractures. Korean J Spine 2 : 333-341, 2005
  17. Leibschner MAK, Rosenberg WS, Keaveny TM : Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty. Spine 26 : 1547-1554, 2001 https://doi.org/10.1097/00007632-200107150-00009
  18. Moreland DB, Landi MK, Grand W : Vertebroplasty : techniques to avoid complications. Spine 1 : 66-71, 2001 https://doi.org/10.1016/S1529-9430(01)00013-4
  19. Mousavi P, Roth S, Finkelstein J, Cheung G, Whyne C : Volumetric quantification of cement leakage following percutaneous vertebroplasty in metastatic and osteoporotic vertebrae. J Neurosurg 99 : 56-59, 2003
  20. Murphy KJ, Deramond H : Percutaneous vertebroplasty in benign and malignant disease. Neuroimaging Clin N Am 10 : 535-545, 2000
  21. Noh CH, Yi JS, Lee HJ, Yang JH, Lee IW, Kim MC : Effect of percutaneous vertebroplasty with polymethylmethacrylate to osteoporotic spinal compression fractures and bursting fractures. J Korean Neurosurg Soc 35 : 365-371, 2004
  22. Perez-Higueras A, Alvarez L, Rossi RE, Quinones D, Al-Assir I : Percutaneous vertebroplasty : long-term clinical and radiological outcome. Neuroradiology 44 : 950-954, 2002 https://doi.org/10.1007/s00234-002-0856-1
  23. Ryu KS, Park CK, Kim MC : Dose-dependent epidural leakage of polymethylmethacrylate after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures. J Neurosurg (Supple) 96 : 56-61, 2002 https://doi.org/10.3171/spi.2002.96.1.0056
  24. Truumees E, Hilibrand A, Vaccaro AR : Percutaneous vertebral augmentation. Spine J 4 : 218-229, 2004 https://doi.org/10.1016/j.spinee.2003.08.029
  25. Tschirhart CE, Sandra ER, Whyne CM : Biomechanical assessment of stability in the metastatic spine following percutaneous vertebroplasty : effects of cement distribution patterns and volume. J Biomech 38 : 1582- 1590, 2005 https://doi.org/10.1016/j.jbiomech.2004.07.023
  26. Zindrick MR, Wiltse LL, Doornik A, Widell EH, Knight GW, Patwardhan AG, et al : Analysis of the morphometric characteristics of the thoracic and lumbar pedicles. Spine 12 : 160-166, 1987 https://doi.org/10.1097/00007632-198703000-00012