Analysis on the corneal thickness and anterior chamber depth of the Keratoconus using Pentacam

  • Kim, Douk-Hoon;Sapkota, Kishor
    • 한국임상보건과학회지
    • /
    • 제6권1호
    • /
    • pp.1089-1096
    • /
    • 2018
  • Purpose: To investigate the corneal thickness and anterior chamber depth (ACD) of eyes with Keratoconus in the Korean population with the Pentacam. Methods: The subjects consisted of 84 eyes from Keratoconic adults aged 7-59 years during 2010. The thinnest area, apex zone, and pupil centre of the corneal thickness were measured using the Pentacam pachymetry. ACD value was also measured with Pentacam. Results: There was a statistically significant relationship between thickness of the cornea at the apex area and the pupil centre (p=0.0001). However, there was no statistical difference (p>0.5) in the mean thickness of thinnest area, apex zone, pupil centre of cornea between right eye and left eye. Also, correlation between ACD and corneal thickness in all subjects had no statistical differences (p>0.05) in all subjects. Conclusion: These results suggested that the regional thickness of cornea and ACD with Pentacam can provide correct and useful diagnostic information of the morphology of Keratoconus for the RGP contact lens and diagnosis of abnormal corneal refraction surgery.

Pentacam을 이용한 한국 청소년 집단에서 각막의 중심두께와 전방깊이 분석 (Analysis of the Central Corneal Thickness and Anterior Chamber Depth of Eyes in Korean Young Population using the Pentacam)

  • 김덕훈;배한용
    • 한국임상보건과학회지
    • /
    • 제1권2호
    • /
    • pp.31-37
    • /
    • 2013
  • Purpose. This study was to investigate the analysis of the central corneal thickness and anterior chamber depth of eyes in Korean Young Population using the Pentacam topography. Methods. The subjects consisted of 126 eyes from normal cornea of Korean aged 7-12($8.857{\pm}1.501$) years during 2009. The thinnest location, pachy apex, and pupil central region of the cornea thickness was measured using the Pentacam pachymetry. The anterior chamber depth of normal corneas was measured with Pentacam. Results. The thinnest location of corneal thickness was $547.413{\pm}37.893$um. The pachy apex of cornea thickness was $552.103{\pm}36.016$um. Also, the pupil center of corneal thickness was measured $552.143{\pm}36.418$um. On the other hand, the mean thickness in the central cornea was a statically significant relationship(t-test, p=0.0002) between pachy apex and thinnest zone. Also the mean thickness of the central cornea was a statically significant correlation(pearson p=0.0001) among the pupil center, pachy apex and thinnest zone. The anterior chamber depth was $3.137{\pm}0.308$mm. The mean depth in the anterior chamber of cornea was a statically relationship(t-test, p>0.05) between OD and OS. Conclusions. The results of this clinical study suggested that the analysis of the central corneal thickness and anterior chamber depth using Pentacam in Korean young population can provide the useful morphological information in diagnosis of cornea for the contact lens fitting and corneal refraction surgery.

  • PDF

Color soft contact lens and corneal thickness

  • Kim, Douk-Hoon
    • 한국임상보건과학회지
    • /
    • 제7권1호
    • /
    • pp.1205-1214
    • /
    • 2019
  • Purpose: To investigate the effect of color soft contact lenses on the corneal thickness in young Korean population. Methods: The subjects consisted of 112 eyes (7 males, 49 females) with the mean age of $20.987{\pm}1.093years$ (range 20-25 years) in young Korean population during 2018. Test was compared the corneal thickness before and after wearing color soft contact lenses. The thinnest cornea thickness(TCT), central cornea thickness(CCT), pupil centre thickness(PCT), superior corneal thickness(SCT),inferior corneal thickness(ICT), medial corneal thickness(MCT), lateral corneal thickness(LCT) of the cornea was measured using the Pentacam pachymetry. The statistically analysis was perform the Shaparo-Wilk test. Results: The right eye was a statistically significant among the CCT,LCT, MCT and TCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. Also the left eye was a statistically significant among the LCT and MCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. However, there was no statistical difference (p>0.5) in the mean PCT between before and after wearing color soft contact lenses. Conclusion: These results suggested that the color soft contact lens wear can the effect the regional thickness of cornea. Therefore, the analysis of corneal topography with Pentacam can provide correct and useful diagnostic information of the morphology of the RGP contact lens fitting and diagnosis of corneal refraction surgery.

측정 범위에 따른 각막비구면계수의 비교 (Comparison of Corneal Asphericity with Measuring Range)

  • 전인철;정우재;강지훈
    • 한국안광학회지
    • /
    • 제17권4호
    • /
    • pp.469-476
    • /
    • 2012
  • 목적: 본 연구의 목적은 각막의 직경과 방향에 따른 비구면계수 변화를 알아보고자 하였다. 방법: 시력에 영향을 줄 수 있는 안과적 질환이 없고 굴절교정 수술 경험이 없는 성인 57명(평균 $27.0{\pm}4.8$세, 남 20명, 여37명)을 대상으로 각막비구면계측기(Pentacam, Oculus Co., Germany)을 이용하여 각막의 직경과 방향에 따른 비구면계수 변화를 측정하였다. 결과: 각막정점을 기준으로 모든 방향에서 직경이 증가함에 따라 비구면계수가 통계적으로 유의하게 증가하였으며(p<0.05), 측정된 모든 직경에서 방향별 비구면계수의 크기는 상측> 비측> 하측> 이측 순으로 나타났다. 강주경선과 약주경선에 따른 비구면계수와 변화량은 강주경선에서 높게 측정되었으며 이는 통계적으로 유의한 것으로 나타났다(p<0.05). 결론: 각막의 비구면계수는 각막의 직경이 증가함에 따라 유의하게 증가하였고, 각막정점을 기준으로 모든 방향에서 측정된 수치나 증가량이 다르게 나타나므로 각막형상을 이해하는데 도움이 되고 RGP 렌즈 제조와 피팅시 고려되어야 할 부분이라 생각된다.

Oculus Pentacam을 사용한 각막 특성 분석 (Study of the cornea characteristics using Oculus Pentacam)

  • 이정영;박은규
    • 한국정보컨버전스학회논문지
    • /
    • 제6권1호
    • /
    • pp.37-41
    • /
    • 2013
  • 본 연구에서는 Oculus Pentacam을 사용하여 20대~40대의 각막 전, 후면 곡률반경 및 각막 난시도의 상호관계를 분석하여 다음과 같은 결과를 얻었다. 전체 대상자의 각막전면 수평곡률반경의 평균값은 남자 7.94mm(${\pm}0.22$), 여자 7.87mm(${\pm}0.21$)이었고 수직곡률반경은 남자 7.69mm(${\pm}0.27$), 여자 7.63mm(${\pm}0.23$)로 나타났고, 각막후면 곡률반경은 수평의 경우 남자가 6.55mm(${\pm}0.22$), 여자가 6.52mm(${\pm}0.23$), 수직의 경우 남자 6.06mm(${\pm}0.24$), 여자 6.08mm(${\pm}0.24$)로 나타났다. 각막전면과 각막후면의 곡률반경 상관관계를 분석해 본 결과 유의한 상관관계가 있는 것으로 나타났다. 본 연구에서 나타난 결과는 각막 전후면 곡률반경, 굴절력, 난시도 등에서 지금까지 보고된 여러 논문들과 유사한 결과를 얻었으나 각막두께에서는 지금까지 보고된 다른 논문에 비해 각막두께가 두껍게 나타났다.

  • PDF

한국인 20세부터 24세까지 각막 두께와 안압의 분석 (Analysis of cornea thickness and intra ocular pressure of 20 to 24 years old population in Korea)

  • 김덕훈
    • 한국임상보건과학회지
    • /
    • 제11권1호
    • /
    • pp.1632-1638
    • /
    • 2023
  • Purpose: The aim of this study was to determine the distribution of the cornea thickness and intra ocular pressure Korean adult of 20 to 24 year old using the Pentacam and tonometer. Methods: The subjects of this study were 43 Korean adults with healthy eyes. Corneal thickness was measured with Pentacam device. The intra ocular pressure was measured with tonometer. Data was analyzed by means of the Pearson's correlation cofficient. P-values<0.001 were considered statistically significant. Results: Mean age of subjects was 20.41±0.86 years. The mean +/- intra ocular pressure of the right eye and left eye were 16.236±2.523mmHg and 16.971±1.992mmHg, respectively. The mean central corneal thickness of the right eye and left eye was 545.324±38.682㎛ and 547.442±33.778㎛, respectively. No significant difference in central corneal thickness was found between the right and left eyes. But, there was a statistically significant difference between central cornea thickness and peripheral cornea thickness around 4 mm of central cornea(p<0.001, Pearson's correlation). However there was no statistically significant difference between central cornea thickness and intra ocular pressure. Conclusion: The results of this study could be used as a clinical reference data for diagnosis and treatment of cornea in Korean adult.

콘택트렌즈의 재질별 각막부종의 비교 (Comparison of Corneal Edema Induced by Material of Contact Lens)

  • 김기성;김선경;김태훈;김효진
    • 한국안광학회지
    • /
    • 제20권2호
    • /
    • pp.151-156
    • /
    • 2015
  • 목적: 콘택트렌즈를 권장착용시간 동안 착용한 후에 렌즈의 재질에 따라 발생하는 각막부종의 정도를 비교해 보고자 한다. 방법: 안질환이나 약물사용이 없는 성인남녀 43명 77안을 대상으로 하였다. Narafilcon A, HEMA, 실리콘 하이드로젤 재질의 정기교체형 렌즈 3종의 렌즈를 사용하였다. 중심각막두께는 Pentacam을 사용하여 렌즈 착용 전과 8시간 착용 후를 측정하였다. 착용 전과 후의 차이 값으로 각막부종의 정도를 판단하였다. 결과: Narafilcon A, HEMA 재질의 렌즈, 실리콘 하이드로젤 재질의 정기교체형 렌즈의 평균 각막부종은 각각 $2.36{\pm}6.15{\mu}m(Mean{\pm}SD)$, $23.61{\pm}10.71{\mu}m$, $18.25{\pm}8.64{\mu}m$였다. Narafilcon A를 착용한 뒤 측정된 중심각막두께는 착용 전 측정한 중심각막두께와 통계적으로 유의한 차이가 없었다. HEMA와 실리콘 하이드로젤 재질의 렌즈에서 착용 후에 유발된 각막부종은 그 정도에 있어 narafilcon A와 통계적으로 유의한 차이가 있었다. 결론: 정기교체형 실리콘 하이드로젤 재질 렌즈에서 유발된 각막부종의 양은 HEMA 재질의 렌즈에서 유발된 각막부종의 양과 통계적으로 유의한 차이가 없었지만 narafilcon A와는 유의한 차이가 있었다. 따라서 콘택트렌즈 재료의 조성에 따라 권장착용시간을 초과하지 않도록 주의해야 할 것으로 판단된다.

한국 성인의 연령에 따른 각막 전후면 구면수차에 관한 분석 (Analysis of anterior and posterior corneal spherical aberration with age in the korean)

  • 송윤영;정미아;강인산;최지영
    • 디지털융복합연구
    • /
    • 제11권1호
    • /
    • pp.315-320
    • /
    • 2013
  • 20~71세 성인을 연령에 따라 5군으로 분류하여 연령에 의한 정상 한국인의 각막 전후면 수차를 알아보기 위하여 수행되었다. 본 연구의 취지에 동의한 사람 가운데 전신질환이나 안질환이 없으며, 굴절이상 수술을 포함하여 안과 관련 수술병력이 없는 성인 290안을 대상으로 Pentacam 을 사용하여 각막곡률반경, 비구면도, 각막 구면수차를 측정하였다. 전체 대상군의 평균 전면 곡률반경과 구면수차 사이에는 음의 상관관계가 나타났고(r = -0.22, p < 0.0001), 평균 후면 곡률반경과 구면수차 사이 또한 음의 상관관계가 나타났다(r = -0.27, p < 0.0001). 또한, 평균 전면 비구면도와 구면수차 사이에는 양의 상관관계가 나타났으나(r = 0.24, p < 0.0001), 평균 후면 비구면도와 구면수차 사이에는 음의 상관관계가 나타났다(r = -0.17, p = 0.00288) 전체 대상군의 전면 구면수차의 평균 값은 $0.482{\pm}0.099{\mu}m$, 후면 구면수차의 평균값은 $-0.098{\pm}0.029{\mu}m$이고, 전체 구면수차의 평균값은 $0.385{\pm}0.097{\mu}m$로 나타났다. 연령에 따른 구면수차의 상관관계를 분석한 결과 전면수차는 연령과 유의한 양의 상관관계(r = 0.227, p<0.0001)를 보였고, 후면 또한 연령과 유의한 양의 상관관계(r = 0.349, p<0.0001)를 나타났다. 한국 정상인의 각막 구면수차 분석을 통하여 한국 정상인 눈의 광학적 부분의 더 나은 이해를 제시하였으며, 현대인의 시력의 질을 향상시키기 위한 추가적인 연구에 활용될 수 있는 기초 자료로 활용 할 수 있을 것으로 사료된다.

Comparison of Intraocular Lens Power Calculation Methods Following Myopic Laser Refractive Surgery: New Options Using a Rotating Scheimpflug Camera

  • Cho, Kyuyeon;Lim, Dong Hui;Yang, Chan-min;Chung, Eui-Sang;Chung, Tae-Young
    • Korean Journal of Ophthalmology
    • /
    • 제32권6호
    • /
    • pp.497-505
    • /
    • 2018
  • Purpose: To evaluate and compare published methods of calculating intraocular lens (IOL) power following myopic laser refractive surgery. Methods: We performed a retrospective review of the medical records of 69 patients (69 eyes) who had undergone myopic laser refractive surgery previously and subsequently underwent cataract surgery at Samsung Medical Center in Seoul, South Korea from January 2010 to June 2016. None of the patients had pre-refractive surgery biometric data available. The Haigis-L, Shammas, Barrett True-K (no history), Wang-Koch-Maloney, Scheimpflug total corneal refractive power (TCRP) 3 and 4 mm (SRK-T and Haigis), Scheimpflug true net power, and Scheimpflug true refractive power (TRP) 3 mm, 4 mm, and 5 mm (SRK-T and Haigis) methods were employed. IOL power required for target refraction was back-calculated using stable post-cataract surgery manifest refraction, and implanted IOL power and formula accuracy were subsequently compared among calculation methods. Results: Haigis-L, Shammas, Barrett True-K (no history), Wang-Koch-Maloney, Scheimpflug TCRP 4 mm (Haigis), Scheimpflug true net power 4 mm (Haigis), and Scheimpflug TRP 4 mm (Haigis) formulae showed high predictability, with mean arithmetic prediction errors and standard deviations of $-0.25{\pm}0.59$, $-0.05{\pm}1.19$, $0.00{\pm}0.88$, $-0.26{\pm}1.17$, $0.00{\pm}1.09$, $-0.71{\pm}1.20$, and $0.03{\pm}1.25$ diopters, respectively. Conclusions: Visual outcomes within 1.0 diopter of target refraction were achieved in 85% of eyes using the calculation methods listed above. Haigis-L, Barrett True-K (no history), and Scheimpflug TCRP 4 mm (Haigis) and TRP 4 mm (Haigis) methods showed comparably low prediction errors, despite the absence of historical patient information.