• 제목/요약/키워드: Penetration resistance test

검색결과 404건 처리시간 0.035초

압전센서를 이용한 콘크리트의 응결시간 추정 (Estimation of setting times of concrete using piezoelectric sensor)

  • 이준철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.99-100
    • /
    • 2021
  • In this study, the setting times of concrete was evaluated using the electro-mechanical (EMI) behavior of piezoelectric sensor embedded in the concrete. Penetration resistance test was also performed to compare with EMI sensing technique. As a result, the setting times of concrete can be measured more effectively than penetration resistance test through the EMI sensing technique using the piezoelectric sensor.

  • PDF

알루미늄 5052-H34 합금 적층재의 방탄성능과 파괴모드에 관한 연구 (A Study on the ballistic performance and fracture mode of anodized Aluminum 5052-H34 alloy laminates)

  • 손세원;김희재;박영의;홍성희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.507-512
    • /
    • 2000
  • The ob.jective of this study is to determine fracture behaviors(penetrati0n modes) and resistance to penetration duringballistic impact of Al 5052-H34 alloy laminates and anodized Al 5052-H34 alloy laminates. Resistance to penetration is determined by $V_{50}$ ballistic limit, a statical velocity with 50% probability for complete penetration, test method. Fracture behaviors and ballistic tolerance, described by penetration modes, are respectfully observed that result from V50 test and Projectile Through Plates (PTP) test at velocities greater than $V_{50}$. PTP tests were conducted with 0" obliquity at room temperature using 5.56mm ball projectile. $V_{50}$ tests with 0" obliquity at room temperature were conducted with projectiles that were able to achieve near or complete penetration during PTP tests. Surface Hardness, resistance to penetration, and penetration modes of A1 5052-H34 alloy laminates compared to those of anodized Al 5052-H34 alloy laminates.y laminates.

  • PDF

PVD처리한 티타늄 합금의 고속충격 거동에 관한 연구 (A Study on the high velocity impact behavior of titanium alloy by PVD method)

  • 손세원;이두성;홍성희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.567-572
    • /
    • 2001
  • In order to investigate the fracture behaviors(penetration modes) and resistance to penetration during ballistic impact of Titanium alloy laminates and nitrified Titanium alloy laminates which were treated by PVD(Physical Vapor Deposition) method, ballistic tests were conducted. Evaporation, sputtering, and ion plating are three kinds of PVD method. In this research, Ion plating was used to achieve higher surface hardness and surface hardness test were conducted using a Micro vicker's hardness tester. Resistance to penetration is determined by the protection ballistic limit($V_{50}$), a statistical velocity with 50% probability for complete penetration. Fracture behaviors and ballistic tolerance, described by penetration modes, are respectfully observed at and above ballistic limit velocities, as a result of $V_{50}$ test and Projectile Through Plates (PTP) test methods. PTP tests were conducted with $0^{\circ}$ obliquity at room temperature using 5.56mm ball projectile. $V_{50}$ test with $0^{\circ}$ obliquity at room temperature were conducted with projectiles that were able to achieve near or complete penetration during PTP tests. Surface hardness, resistance to penetration, and penetration modes of Titanium alloy laminates are compared to those of nitrified Titanium alloy laminates.

  • PDF

콘 관입저항치를 이용한 수직배수재 타설심도 결정에 관한 연구 (A Study on the Determination of Construction Depth of Vertical Drain by Cone Resistance)

  • 김연정;김남호;신윤섭
    • 기술발표회
    • /
    • 통권2006호
    • /
    • pp.261-269
    • /
    • 2006
  • 최근 피조콘시험은 과거 일반적으로 사용되었던 표준관입시험과 함께 연약지반의 특성을 평가하기 위해 빈번히 사용되고 있다. 본 연구에서는 하부지반의 지층상태를 파악하고 설계를 위한 연약지반 심도 결정 및 시공시 수직배수재 타설심도 결정시 그 신뢰도를 향상시키기 위해서 표준관입시험결과(N치), 선행압밀하중(pc), 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치($q_c$)와의 관계를 분석하였다. 대상 지역별로 일정한 표준관입저항치를 기준으로 평균 연약지반심도를 결정하여, 동일한 심도에서 피조콘관입저항치를 값을 분석한 결과 $q_c$=(1.09~1.63)N, 선행압밀하중을 고려한 결과 $q_c$=(1.21~1.98)N의 관계를 나타내었다. 또한 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치($q_c$)와의 관계를 분석한 결과 평균적으로 피조콘 관입저항치 10kgf/$cm^2$의 경우 수직배수재 타설 시 관입저항치는 약 65~70.0kgf/$cm^2$의 값을 나타내였다.

  • PDF

고속충격을 받는 Ti/Al 적층재의 파괴거동에 관한 연구 (A study on the fracture behavior of Ti/Al laminates under high velocity impact)

  • 손세원;이두성;홍성희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.267-272
    • /
    • 2003
  • In order to investigate the effect of face material on Ti/Al alloy laminates under high velocity impact, a ballistic testing was conducted. Ballistic resistance of these materials was measured by protection ballistic limit($V_{50}$), a statistical velocity with 50% probability penetration. Fracture behaviors and ballistic tolerance, described by penetration modes, were respectfully observed, by $V_{50}$ test and Projectile Through Plates (PTP) test at velocities greater than $V_{50}$. PTP tests were conducted with $0^{\circ}$obliquity at room temperature using 5.56mm ball projectile. $V_{50}$ tests with $0^{\circ}$obliquity were also done with projectiles that were able to achieve near or complete penetration during PTP tests. Resistance to penetration, and penetration modes which face material was Titanium alloy, were compared to those which face material was anodized Al alloy after cold-rolling.

  • PDF

The Perforation Behavior of the Anodized AI Light Armor under High Velocity Impact

  • Sohn, Se-Won;Lee, Doo-Sung;Kim, Hee-Jae;Hong, Sung-Hee
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제4권4호
    • /
    • pp.45-50
    • /
    • 2003
  • In order to investigate the effect of surface treatment (Anodizing) and rolling on AI 5083-H131 alloy, under hyper velocity impact, a ballistic testing was conducted. Ballistic resistance of these materials was measured by a protection ballistic limit ($V_{50}$)' a statistical velocity with 50% probability of penetration. Perforation behavior and ballistic tolerance, described by penetration modes, were respectfully observed, by $V_{50}$ test and Projectile Through Plates (PTP) test at velocities greater than $V_{50}$. PTP tests were conducted with 0$^{\circ}$ obliquity at room temperature using 5.56mm ball projectiles. $V_{50}$ tests with 0$^{\circ}$ obliquity were also done with projectiles that were able to achieve near or complete penetration during PTP tests. Resistance to penetration, and penetration modes of Al 5052-H34 alloy were compared to those of Al 5083-H 131 alloy.

콘 관입저항치를 이용한 수직배수재 타설심도 결정에 관한 연구 (A Study on the Determination of Construction Depth of Vertical Drain by Cone Resistance)

  • 장서용;김종렬;신윤섭;마봉덕
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권5호
    • /
    • pp.163-170
    • /
    • 2006
  • 최근 피조콘시험은 과거 일반적으로 사용되었던 표준관입시험과 함께 연약지반의 특성을 평가하기 위해 빈번히 사용되고 있다. 본 연구에서는 하부지반의 지층상태를 파악하고 설계를 위한 연약지반 심도 결정 및 시공시 수직배수재 타설심도 결정시 그 신뢰도를 향상시키기 위해서 표준관입시험결과, 선행압밀하중, 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치와의 관계를 분석하였다. 대상 지역별로 일정한 표준관입저항치를 기준으로 평균 연약지반심도를 결정하여, 동일한 심도에서 피조콘관입저항치를 값을 분석한 결과 qc=(1.09~1.63)N, 선행압밀하중을 고려한 결과 qc=(1.21~1.98)N의 관계를 나타내었다. 또한 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치(qc)와의 관계를 분석한 결과 평균적으로 피조콘 관입저항치 $10kgf/cm^2$의 경우 수직배수재 타설 시 관입저항치는 약 $65{\sim}70kgf/cm^2$ 의 값을 나타내었다.

Evaluation on Sensitivity and Approximate Modeling of Fire-Resistance Performance for A60 Class Deck Penetration Piece Using Heat-Transfer Analysis and Fire Test

  • Park, Woo Chang;Song, Chang Yong
    • 한국해양공학회지
    • /
    • 제35권2호
    • /
    • pp.141-149
    • /
    • 2021
  • The A60 class deck penetration piece is a fire-resistance apparatus installed on the deck compartment to protect lives and to prevent flame diffusion in the case of a fire accident in a ship or offshore plant. In this study, the sensitivity of the fire-resistance performance and approximation characteristics for the A60 class penetration piece was evaluated by conducting a transient heat-transfer analysis and fire test. The transient heat-transfer analysis was conducted to evaluate the fire-resistance design of the A60 class deck penetration piece, and the analysis results were verified via the fire test. The penetration-piece length, diameter, material type, and insulation density were used as the design factors (DFs), and the output responses were the weight, temperature, cost, and productivity. The quantitative effects of each DF on the output responses were evaluated using the design-of-experiments method. Additionally, an optimum design case was identified to minimize the weight of the A60 class deck penetration piece while satisfying the allowable limits of the output responses. According to the design-of-experiments results, various approximate models, e.g., a Kriging model, the response surface method, and a radial basis function-based neural network (RBFN), were generated. The design-of-experiments results were verified by the approximation results. It was concluded that among the approximate models, the RBFN was able to explore the design space of the A60 class deck penetration piece with the highest accuracy.

조석 영향에 의한 해성준설토의 강도변화 특성에 관한 연구 (Characteristics of the Strength Change of Dredged Soil by Tide Influence)

  • 천병식;김봉수;이원택;도종남
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1071-1074
    • /
    • 2008
  • In this study, the behavior of dredged soil was measured by repeated tide and analyzed the change of settlements and cone penetration resistance by centrifuge model about dredged soil of Kunsan-Janghang site that maximum tidal range is 7.4m. Consequently the settlements of dredged soil by repeated tide in the 2nd month was 0.489 m. After 12th month, the total settlements was 0.524 m in the model. It meaned the settlements of dredged soil by repeated tide in the 2th month was 80% of the settlements. Also, with the lapse of time, cone penetration resistance increased centrifuge model test for catching the strength change of dredged soil by repeated tide. After 10th month, there were not almost changes. cone penetration resistance in 10th month was measured more 3.5~5.6 times than that in its early stages. Also, with the lapse of time, cone penetration resistance increased almost linearly. And, when we surveyed the relation between cone penetration resistance and time, as depth increased, cone penetration resistance rose.

  • PDF

표면 경화 처리된 Al, Ti의 고속 충격 저항성에 관한 연구 (A Study on the resistance of surface hardening treated Aluminum, Titanium alloy under the high velocity impact)

  • 손세원;김희재;홍성희;김영태
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.852-855
    • /
    • 2002
  • In order to investigate the fracture behaviors(penetration modes) and resistance to penetration during ballistic impact of surface hardening treated Aluminum, Titanium alloy laminates, ballistic tests were conducted. In this paper, Anodized Al 5083-H131 alloy laminates and nitrified Ti (Gr.2) alloy laminates were used to achieve higher surface hardness. Surface hardness test were conducted using a Micro victor's hardness tester and thickness of surface hardening treated specimens was measured by video microscope. Resistance to penetration is determined by the protection ballistic limit($V_50$), a statistical velocity with 50% probability far complete penetration. Fracture behaviors and ballistic tolerance, described by penetration modes, are respectfully observed at and above ballistic limit velocities, as a result of $V_50$ test and Projectile Through Plates (PTP) test methods. PTP tests were conducted with $0^{\circ}$ obliquity at room temperature using 5.56mm ball projectile. $V_50$ tests with $0^{\circ}$ obliquity at room temperature were conducted with projectiles that were able to achieve near or complete penetration during PTP tests.

  • PDF