• Title/Summary/Keyword: Pelvic correction

Search Result 37, Processing Time 0.023 seconds

Surgical Corrections of Perineal Hernia by Muscle Transposition in Dogs (근육전위을 이용한 회음허니아의 교정)

  • Lee Hae-beom;Choi Sung-jin;Lee Cheol-ho;Chon Seung-ki;Choi In-hyuk;Kim Nam-soo
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.435-438
    • /
    • 2005
  • Two dogs (case 1:2-year-old intact male German Shepherd-mixed dog and case 2: 4-year-old intact female Jindo miked) with perineal hernia were referred to the Chonbuk Animal Medical Center, Chonbuk National University. In the both cases, there were unilateral perineal swelling involving the right side of the anus. In addition, in case 2, swelling was also present ventral to the anus. Rectal palpation of pelvic diaphragm revealed weakness of the muscles. Both cases were surgically treated using muscle transposition technique for hemiorrhaphy. In case 1, transposition of the superficial gluteal and internal obturator muscles and in case 2, transposition oi semitendinosus muscle was performed for hemiorrhaphy and reconstruction of the pelvic diaphragm. Both dogs became recovered after the surgical correction and no complications were observed during 10-month (casel) and 9-month(case2). Muscle transposition can be a useful technique for the treatment of perineal hernia in the dog.

Effects of Axillary Crutch Length on EMG Activity of the Trunk Muscles and Range of Motion of the Lumbar Spine, Pelvis, and Hip Joint in Healthy Men

  • Kang, Min-Hyeok;Jang, Jun-Hyeok;Kim, Tae-Hoon;Oh, Jae-Seop
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.55-63
    • /
    • 2013
  • This study investigated the effects of axillary crutch length on trunk muscle activity and lumbo-pelvic-hip complex movements during crutch gait. Eleven healthy men participated in this study. The participants performed a three-point gait with optimal, shorter, and longer crutch lengths. Weight-bearing (WB) side was determined as the dominant leg side. The electromyography (EMG) activity of the bilateral rectus abdominis (RA) and erector spinae (ES) muscles and lumbo-pelvic-hip complex movements were monitored using a three-dimensional motion system with wireless surface EMG. Differences in the EMG activity of RA and ES muscles and range of motion (ROM) of lumbar spine, pelvis, and hip among conditions were analyzed using one-way repeated-measures analysis of variance, and a Bonferroni correction was conducted. There was less RA muscle activity on the WB side under the optimal crutch length condition compared with shorter and longer crutch length conditions (p<.05). The EMG activity of the RA muscle on the non-WB side and ES muscle on the WB side were significantly decreased under the optimal crutch length condition compared with shorter crutch length condition (p<.05). No significant differences in the EMG activity of the ES muscle on the non-WB side and ROM of lumbo-pelvic-hip complex were found among conditions (p>.05). These findings indicate that the optimal crutch length improves the trunk muscle efficiency during crutch gait.

Study of Scatter Influence of kV-Conebeam CT Based Calculation for Pelvic Radiotherapy (골반 방사선 치료에서 산란이 kV-Conebeam CT 영상 기반의 선량계산에 미치는 영향에 대한 연구)

  • Yoon, KyoungJun;Kwak, Jungwon;Cho, Byungchul;Kim, YoungSeok;Lee, SangWook;Ahn, SeungDo;Nam, SangHee
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.37-45
    • /
    • 2014
  • The accuracy and uniformity of CT numbers are the main causes of radiation dose calculation error. Especially, for the dose calculation based on kV-Cone Beam Computed Tomography (CBCT) image, the scatter affecting the CT number is known to be quite different by the object sizes, densities, exposure conditions, and so on. In this study, the scatter impact on the CBCT based dose calculation was evaluated to provide the optimal condition minimizing the error. The CBCT images was acquired under three scatter conditions ("Under-scatter", "Over-scatter", and "Full-scatter") by adjusting amount of scatter materials around a electron density phantom (CIRS062, Tissue Simulation Technology, Norfolk, VA, USA). The CT number uniformities of CBCT images for water-equivalent materials of the phantom were assessed, and the location dependency, either "inner" or "outer" parts of the phantom, was also evaluated. The electron density correction curves were derived from CBCT images of the electron density phantom in each scatter condition. The electron density correction curves were applied to calculate the CBCT based doses, which were compared with the dose based on Fan Beam Computed Tomography (FBCT). Also, 5 prostate IMRT cases were enrolled to assess the accuracy of dose based on CBCT images using gamma index analysis and relative dose differences. As the CT number histogram of phantom CBCT images for water equivalent materials was fitted with a gaussian function, the FHWM (146 HU) for "Full-scatter" condition was the smallest among the FHWM for the three conditions (685 HU for "under scatter" and 264 HU for "over scatter"). Also, the variance of CT numbers was the smallest for the same ingredients located in the center and periphery of the phantom in the "Full-scatter" condition. The dose distributions calculated with FBCT and CBCT images compared in a gamma index evaluation of 1%/3 mm criteria and in the dose difference. With the electron density correction acquired in the same scatter condition, the CBCT based dose calculations tended to be the most accurate. In 5 prostate cases in which the mean equivalent diameter was 27.2 cm, the averaged gamma pass rate was 98% and the dose difference confirmed to be less than 2% (average 0.2%, ranged from -1.3% to 1.6%) with the electron density correction of the "Full-scatter" condition. The accuracy of CBCT based dose calculation could be confirmed that closely related to the CT number uniformity and to the similarity of the scatter conditions for the electron density correction curve and CBCT image. In pelvic cases, the most accurate dose calculation was achievable in the application of the electron density curves of the "Full-scatter" condition.

Effects of Self-Traction Exercises on the Vertebral Alignment, Muscle Strength, and Flexibility of Adults in Their Twenties with Scoliosis

  • Kim, Yongmin;Jeon, Changkeun;Yoo, Kyoungtae
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.2
    • /
    • pp.1810-1817
    • /
    • 2019
  • Background: Effect of cervical and lumbar tractions on the reduction in the angle of curvature and the effect of a correction exercise or a general traction method on balance, muscle strength, pain, and body alignment, however insufficient research has been undertaken on self traction exercises targeting patients with scoliosis. Purpose: To determine the effect of cervical and lumbar tractions on the reduction in the angle of curvature and the effect of a correction exercise or a general traction method on balance, muscle strength, pain, and body alignment. Design: Randomized controlled clinical trial (single blinded) Methods: Twelve adults(20s) with scoliosis were included in this study and performed a traction program that was composed of a 5-min warm-up exercise, a 15-min main exercise, and a 5-min cool-down exercise (25 minutes in total), three times a week for four weeks. The Chiro traction machine was used for the self-traction exercise. Vertebral alignment, muscle strength, and flexibility were compared before and after the intervention using the paired T-test. Results: The scoliosis angle, pelvic torsion, and lumbar extensor were significantly changed by intervention; however, there was no significant difference in flexibility. Conclusion: The results revealed that self-traction exercise activated blood flow through the extension and contraction of muscles, effectively increasing the function of the muscles around the vertebrae.

A comparison of bladder volume by sonogram and CBCT for Pelvic region cancer (골반부 암 치료 시 초음파검사를 통한 방광체적과 CBCT영상 방광체적의 비교)

  • Son, Seong Ho;Park, Ha Ryung;Baek, Jung Jin;Son, Jong Ki;Choi, Min Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.7-12
    • /
    • 2019
  • Purpose: During the pelvic radiation therapy, it is performed with controlling bladder volume because the range of irradiation is changed depending on the bladder volume. Therefore in this study, we evaluate the accuracy of BVI by tracing the change of bladder volume using ultrasonic pulse diagnosis equipment(BVI 6100, Medical supply Co. LTD) Material and Methods: From January 2017 to September 2018, 19 patients who received pelvic radiation therapy at Pusan National University Hospital were included. To treat the patient, we compared that the bladder volume obtained from the BVI and the bladder volume obtained from the CBCT image then we evaluated for significance. Results: There was a significant correlation of r=0.773, BVI and CBCT in the whole volume section. However, based on the bladder volume in the RTP Image the p value was shown to be 0 at 125~175cc and lower than 0.05 at 175~275cc, And more than 0.05 at 275~375cc. Conclusions: In this study, the patient whose bladder volume is above than 275cc, there is a significance of bladder volume between BVI and CBCT image. However, we could make a decision to be undermined the reliability of BVI measurement in the case of the patient with emptied his urine. Therefore, it is possible to acquire a significant value for 175~275cc patients to use the correction value of BVI and the appropriate tolerance of volume.

Contribution of Lateral Interbody Fusion in Staged Correction of Adult Degenerative Scoliosis

  • Choi, Seung Won;Ames, Christopher;Berven, Sigurd;Chou, Dean;Tay, Bobby;Deviren, Vedat
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.6
    • /
    • pp.716-722
    • /
    • 2018
  • Objective : Lateral interbody fusion (LIF) is attractive as a less invasive technique to address anterior spinal pathology in the treatment of adult spinal deformity. Its own uses and benefits in treatment of adult degenerative scoliosis are undefined. To investigate the radiographic and clinical outcomes of LIF, and staged LIF and posterior spinal fusion (PSF) for the treatment of adult degenerative scoliosis patients, we analyzed radiographic and clinical outcomes of adult degenerative scoliosis patients who underwent LIF and posterior spinal fusion. Methods : Forty consecutive adult degenerative scoliosis patients who underwent LIF followed by staged PSF at a single institution were retrospectively reviewed. Long-standing 36" anterior-posterior and lateral radiographs were taken preoperatively, at inter-stage, 3 months, 1 year, and 2 years after surgery were reviewed. Outcomes were assessed through the visual analogue scale (VAS), 36-Item Short Form Health Survey (SF-36), and Oswestry Disability Index (ODI). Results : Forty patients with a mean age of 66.3 (range, 49-79) met inclusion criteria. A mean of 3.8 levels (range, 2-5) were fused using LIF, while a mean of 9.0 levels (range, 3-16) were fused during the posterior approach. The mean time between stages was 1.4 days (range, 1-6). The mean follow-up was 19.6 months. Lumbar lordosis was significantly restored from $36.4^{\circ}$ preoperatively up to $48.9^{\circ}$ (71.4% of total correction) after LIF and $53.9^{\circ}$ after PSF. Lumbar coronal Cobb was prominently improved from $38.6^{\circ}$ preoperatively to $24.1^{\circ}$ (55.8% of total correction) after LIF, $12.6^{\circ}$ after PSF respectively. The mean pelvic incidence-lumbar lordosis mismatch was markedly improved from $22.2^{\circ}$ preoperatively to $8.1^{\circ}$ (86.5% of total correction) after LIF, $5.9^{\circ}$ after PSF. Correction of coronal imbalance and sagittal vertebral axis did not reach significance. The rate of perioperative complication was 37.5%. Five patients underwent revision surgery due to wound infection. No major perioperative medical complications occurred. At last follow-up, there were significant improvements in VAS, SF-36 Physical Component Summary and ODI scores. Conclusion : LIF provides significant corrections in the coronal and sagittal plane in the patients with adult degenerative scoliosis. However, LIF combined with staged PSF provides more excellent radiographic and clinical outcomes, with reduced perioperative risk in the treatment of adult degenerative scoliosis.

Palliative Irradiation Using Helical Tomotherapy in Recurrent Pelvic Tumors with Prior Radiotherapy (방사선치료 후 재발한 골반암에서 토모테라피를 이용한 고식적 재치료)

  • Kay, Chul-Seung;Yoo, Eun-Jung;Kim, Ji-Hoon;Ro, Duck-Young;Kim, Ki-Jun
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.133-140
    • /
    • 2010
  • Purpose: We retrospectively investigated the effect of irradiation using helical tomotherapy in recurrent pelvic tumors that underwent prior irradiation. Materials and Methods: Fourteen patients with recurrent pelvic tumors consisting of rectal cancer (57.1%), cervical cancer (35.7%) and cancer with an unknown origin (7.1%) were treated with tomotherapy. At the time of irradiation, median tumor size was 3.5 cm and 7 patients complained of pain originating from a recurrent tumor. The median radiation dose delivered to the gross tumor volume, clinical target volume, and planning target volume was 50 Gy, 47.8 Gy and 45 Gy, respectively and delivered at 5 fractions per week over the course of 4 to 5 weeks. Treatment response and duration of local disease control were evaluated using the Response Evaluation Criteria in Solid Tumors (ver. 1.0) and the Kaplan-Meyer method. Treatment-related toxicities were assessed through Common Terminology Criteria for Adverse Events (ver. 3.0). Results: The median follow-up time was 17.3 months, while the response rate was 64.3%. Symptomatic improvement appeared in 6 patients (85.7%). The median duration time of local disease control was 25.8 months. The rates of local failure, distant failure, and synchronous local and distant failure were 57.1%, 21.4%, and 7.1%, respectively. Acute toxicities were limited in grade I or II toxicities, except for one patient. No treatment related death or late toxicity was observed. Conclusion: Helical tomotherapy could be suggested as a feasible palliative option in recurrent pelvic tumors with prior radiotherapy. However, to increase treatment effect and overcome the limitation of this outcome, a large clinical study should be performed.

Effects of Seated Exercise of Thoracic and Abdominal Muscles on Upper Extremity Function and Trunk Muscles Activity in Patients with Chronic Stroke

  • Park, Shinjun;Kim, Sangduk
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.2
    • /
    • pp.2065-2070
    • /
    • 2020
  • Background: Weakness of the abdominal and mid thoracic muscles the lead to thoracic kyphosis of stroke patients. The trunk muscles activity of stroke patients is significantly related to upper extremity. Objectives: To investigate the effect of seated exercise of thoracic and abdominal muscles on upper extremity function and trunk muscles activity in stroke patients. Design: One-group pretest-posttest design. Methods: A total of 27 stroke patients were recruited. All stroke patient were given seated abdominal exercise (posterior pelvic tilt exercises) and thoracic exercise (postural-correction exercise). All exercises were conducted for 30 minutes, three times a week for four weeks. The manual function test (MFT) and electromyography (EMG) were measured, and EMG electrodes were attached to thoracic paraspinal muscles and lower rectus abdominal muscles. EMG signal is expressed as %RVC (reference voluntary contraction). Results: Experimental group showed significant increases in abdominal muscles, paraspinal muscles activity and MFT total score, items of arm motion (forward elevation of the upper extremity, lateral elevation of the upper extremity, touch the occiput with the palm) in MFT after four weeks. Conclusion: These results suggest that, in stroke patients, seated exercise of thoracic and abdominal muscles contribute to improve trunk muscles activity and upper extremity function in stroke patients.

Radiographic and Clinical Outcomes Following Pedicle Subtraction Osteotomy : Minimum 2-Year Follow-Up Data

  • Choi, Ho Yong;Hyun, Seung-Jae;Kim, Ki-Jeong;Jahng, Tae-Ahn;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.1
    • /
    • pp.99-107
    • /
    • 2020
  • Objective : The purpose of this study was to report the results of pedicle subtraction osteotomy (PSO) for fixed sagittal imbalance with a minimum 2-year follow-up. Besides, authors evaluated the effect of adjunctive multi-level posterior column osteotomy (PCO) on achievement of additional lumbar lordosis (LL) during PSO. Methods : A total of 31 consecutive patients undergoing PSO for fixed sagittal imbalance were enrolled and analyzed. Correction angle of osteotomized vertebra (PSO angle) and other radiographic parameters including pelvic incidence (PI), thoracic kyphosis, LL, and sagittal vertical axis (SVA) were evaluated. Clinical outcomes and surgical complications were also assessed. Results : The mean age was 66.0±9.3 years with a mean follow-up period of 33.2±10.5 months. The mean number of fused segments was 9.6±3.5. The mean operative time and surgical bleeding were 475.9±160.5 minutes and 1406.1±932.1 mL, respectively. The preoperative SRS-22 score was 2.3±0.7 and improved to 3.2±0.8 at the final follow-up. The mean PI was 54.5±9.5°. LL was changed from 7.0±28.9° to -50.2±13.2°. The PSO angle was 33.7±13.5° (15.6±20.1° preoperatively, -16.1±19.4° postoperatively). The difference of correction angle of LL (57.3°) was greater about 23.6° than which of PSO angle (33.7°). SVA was improved from 189.5±93.0 mm, preoperatively to 12.4±40.8 mm, postoperatively. There occurred six, eight, and 14 cases of complications at intraoperative, early (<2 weeks) postoperative, and late (≥2 weeks) postoperative period, respectively. Additional operations were needed in nine patients due to the complications. Conclusion : PSO could provide satisfactory results for patients with fixed sagittal imbalance regarding clinical and radiographic outcomes. Additional correction of LL could be achieved with conduction of adjunctive multi-level PCOs during PSO.

The Investigation Regarding the Dose Change due to the Heterogeneity of Prostate Cancer Treatment with IMRT (전립선암의 세기조절 방사선치료 시 불균질부에 의한 선량변화에 관한 고찰)

  • Yoon, Il-Kyu;Park, Jang-Pil;Lee, Jae-Hee;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.107-112
    • /
    • 2007
  • Purpose: The pelvic phantom was fabricated in the following purposes: (1) Dose verification of IMRT plan using Eclipse planning computer, (2) to study the interface effect at the interface between rectal wall and air. The TLD can be inserted in the pelvic phantom to confirm the dose distribution as well as uncertainty at the interface. Materials and Methods: A pelvic phantom with the dimension of 30 cm diameter, 20 cm height and 20 cm thickness was fabricated to investigate the dose at the rectal wall. The phantom was filled with water and has many features like bladder, rectum, and prostate and seminal vesicle (SV). The rectum is made of 3 cm-dimater plastic pipe, and it cab be blocked by using a plug, and film can be inserted around the rectal wall. The phantom was scanned with Philips Brillance scanner and various organs such as prostate, SV, and rectal wall, and bladder wall were delineated. The treatment parameters used in this study are the same as those used in the protocols in the SNUH. TLD chips are inserted to the phantom to evaluate the dose distribution to the rectal wall (to simulate high dose gradient region), bladder wall and SV (to simulate the high dose region) and 2 spots in anterior surface (to simulate the low dose region). The TLD readings are compared with those of the planning computer (ECLIPSE, Varian, USA). Results: The target TLD doses represented as the prostate and SV show excellent agreements with the doses from the RTP within +/-3%. The rectal wall doses measured at the rectal wall are different from the those of the RTP by -11%. This is in literatures called as an interface effect. The underdosages at the rectal wall is independent of 3 heterogeneity correction algorithm in the Eclipse RTP. Also the low dose regions s represented as surface in this study were within +/-1%. Conclusion: The RTP estimate the dosage very accurately withihn +/-3% in the high dose (SV, or prostate) and low dose region (surface). However, the dosage at the rectal wall differed by as much as 11% (In literatures, the underdosage of 9$\sim$15% were reported). This range of errors occurs at the interface, for example, at the interface between lung and chest wall, or vocal cord. This interface effect is very important in clinical situations, for example, to estimate the NTCP (normal tissue complication probability) and to estimate the limitations of the current RTP system. Monte-carlo-based RTP will handle this issue correctly.

  • PDF