• Title/Summary/Keyword: Peak-hour ratio

Search Result 42, Processing Time 0.025 seconds

Derivation of the Instantaneous Unit Hydrograph and Estimation of the Direct Runoff by Using the Geomorphologic Parameters (지상인자에 의한 순간단위도 유도와 유출량 예측)

  • 천만복;서승덕
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.3
    • /
    • pp.87-101
    • /
    • 1990
  • The purpose of this study is to estimate the flood discharge and runoff volume at a stream by using geomorphologic parameters obtained from the topographic maps following the law of stream classification and ordering by Horton and Strahier. The present model is modified from Cheng' s model which derives the geomorphologic instantaneous unit hydrograph. The present model uses the results of Laplace transformation and convolution intergral of probability density function of the travel time at each state. The stream flow velocity parameters are determined as a function of the rainfall intensity, and the effective rainfall is calculated by the SCS method. The total direct runoff volume until the time to peak is estimated by assuming a triangular hydrograph. The model is used to estimate the time to peak, the flood discharge, and the direct runoff at Andong, Imha. Geomchon, and Sunsan basin in the Nakdong River system. The results of the model application are as follows : 1.For each basin, as the rainfall intensity doubles form 1 mm/h to 2 mm/h with the same rainfall duration of 1 hour, the hydrographs show that the runoff volume doubles while the duration of the base flow and the time to peak are the same. This aggrees with the theory of the unit hydrograph. 2.Comparisions of the model predicted and observed values show that small relative errors of 0.44-7.4% of the flood discharge, and 1 hour difference in time to peak except the Geomchon basin which shows 10.32% and 2 hours respectively. 3.When the rainfall intensity is small, the error of flood discharge estimated by using this model is relatively large. The reason of this might be because of introducing the flood velocity concept in the stream flow velocity. 4.Total direct runoff volume until the time to peak estimated by using this model has small relative error comparing with the observed data. 5.The sensitivity analysis of velocity parameters to flood discharge shows that the flood discharge is sensitive to the velocity coefficient while it is insensitive to the ratio of arrival time of moving portion to that of storage portion of a stream and to the ratio of arrival time of stream to that of overland flow.

  • PDF

Optical Properties of Silicon Oxide (SiOx, x<2) Thin Films Deposited by PECVD Technique (PECVD 방법으로 증착한 SiOx(x<2) 박막의 광학적 특성 규명)

  • Kim, Youngill;Park, Byoung Youl;Kim, Eunkyeom;Han, Munsup;Sok, Junghyun;Park, Kyoungwan
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.9
    • /
    • pp.732-738
    • /
    • 2011
  • Silicon oxide thin films were deposited by using a plasma-enhanced chemical-vapor deposition technique to investigate the light emission properties. The photoluminescence characteristics were divided into two categories along the relative ratio of the flow rates of $SiH_4$ and $N_2O$ source gases, which show light emission in the broad/visible range and a light emission peak at 380 nm. We attribute the broad/visible light emission and the light emission peak to the quantum confinement effect of nanocrystalline silicon and the Si=O defects, respectively. Changes in the photoluminescence spectra were observed after the post-annealing processes. The photoluminescence spectra of the broad light emission in the visible range shifted to the long wavelength and were saturated above an annealing temperature of $900^{\circ}C$ or after 1 hour annealing at $970^{\circ}C$. However, the position of the light emission peak at 380 nm did not change at all after the post-annealing processes. The light emission intensities at 380 nm initially increased, and decreased at annealing temperatures above $700^{\circ}C$ or after 1 hour annealing at $700^{\circ}C$. The photoluminescence behaviors after the annealing processes can be explained bythe size change of the nanocrystalline silicon and the density change of Si=O defect in the films, respectively. These results support the possibility of using a silicon-based light source for Si-optoelectronic integrated circuits and/or display devices.

Effect of Pulmonary Arterial Size on Postoperative Right Ventricular Pressure in Tetralogy of Fallot (활로씨 4 증후군에 폐동맥크기가 수술후 우심실압력에 미치는 영향)

  • 김용진
    • Journal of Chest Surgery
    • /
    • v.21 no.5
    • /
    • pp.828-841
    • /
    • 1988
  • To predict the postoperative hemodynamic status of right ventricle preoperatively, a retrospective analysis was undertaken to determine the influence of pulmonary artery size on postoperative right ventricular pressure in 32 consecutive patients with tetralogy of Fallot who underwent total correction between July, 1987 to June, 1988 at the Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital. We have related the ratio of the postrepair peak systolic pressure in the right ventricle and the systemic systolic arterial pressure[PRV/Ao] to the preoperative cineangiographic measurement of pulmonary arterial tree, expressed as pulmonary artery index[PAI], the ratio of diameter of the right pulmonary artery to diameter of ascending aorta[r.PA/A.Ao], the ratio of right and left pulmonary artery to diameter of descending aorta[r.I.PA/D.Ao] There was tendency that the postrepair PRV/Ao seems to be related to the preoperative diameter of right and left pulmonary artery, but there were no statistically significant correlation with PAI, r.PA/A.Ao, r.l.PA/D. Ao to the ratio of the postoperative peak systolic right ventricular pressure and systemic systolic arterial pressure[PRV/Ao]. There was tendency to decrease the postoperative right ventricular pressure[PRV/Ao] about 11.2%[P < 0.025] within several hours than immediately after repair, but after then, there was no change of right ventricular pressure[PRV/Ao] significantly. There was good correlation of pressure change between the immediate and late postrepair right ventricular pressure[48 hour], and the derived linear regression line was; y=0.68534 0.1994[r=0.57294, P < 0.001]. There was no operative death due to residual high right ventricular pressure[PRV/Ao >0.75] related to hypoplastic pulmonary arterial development, thus we expect, for symptomatic patients even infants, that complete repair can be attempted when the pulmonary artery index[PAI] is over 108mm2/BSA, RPA/AAo is over 0.35, RPA LPA/D. Ao is over 1.36.

  • PDF

A Study on Characteristic Design Hourly Factor by Road Type for National Highways (일반국도 도로유형별 설계시간계수 특성에 관한 연구)

  • Ha, Jung-Ah
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.2
    • /
    • pp.52-62
    • /
    • 2013
  • Design Hourly Factor(DHF) is defined as the ratio of design hourly volume(DHV) to Average Annual Daily Traffic(AADT). Generally DHV used the 30th rank hourly volume. But this case DHV is affected by holiday volumes so the road is at risk for overdesigning. Computing K factor is available for counting 8,760 hour traffic volume, but it is impossible except permanent traffic counts. This study applied three method to make DHF, using 30th rank hourly volume to make DHF(method 1), using peak hour volume to make DHF(method 2). Another way to make DHF, rank hourly volumes ordered descending connect a curve smoothly to find the point which changes drastic(method 3). That point is design hour, thus design hourly factor is able to be computed. In addition road classified 3 type for national highway using factor analysis and cluster analysis, so we can analyze the characteristic of DHF by road type. DHF which was used method 1 is the largest at any other method. There is no difference in DHF by road type at method 2. This result shows for this reason because peak hour is hard to describe the characteristic of hourly volume change. DHF which was used method 3 is similar to HCM except recreation road but 118th rank hourly volume is appropriate.

Diel Feeding Activity in Summer of Juvenile Pacific Herring, Clupea pallasii in the Southeastern Coast of Korea (여름철 동해 남부에 출현하는 청어(Clupea pallasii) 유어의 일섭식 변동)

  • Park, Joo Myun;Huh, Sung-Hoi
    • Korean Journal of Ichthyology
    • /
    • v.29 no.4
    • /
    • pp.267-271
    • /
    • 2017
  • Diel changes in feeding activity of juvenile Pacific herring, Clupea pallasii were investigated throughout the analysis of stomach contents of 301 fishes collected from the southeastern coast of Korea. Fish samples were collected every 3 hour over a 24 h period in summer using small bottom trawl. The ratio of empty stomach, stomach fullness, stomach contents index (SCI) and stomach fullness index (IF) of juvenile C. pallasii were varied markedly with day/night changes. The ratio of empty stomach tended be higher during nighttime, while the other values were higher at daytime, with showing peak before sunset. During daytime, the stomach contents mainly were made up of copepods and euphausiids, while the diets at midnight were composed of nearly digested and unidentifiable items.

Observational Study for the Thermal Environment Evaluation of Summertime over the Asphalt Pavement - Case Study in Daegu 2014 -

  • Kim, Hae-Dong;Kim, Sung-Rak;Kim, Baek-Jo
    • Journal of Environmental Science International
    • /
    • v.24 no.10
    • /
    • pp.1265-1272
    • /
    • 2015
  • To investigate the thermal environment over the summertime asphalt pavements, an automatic weather observation system was installed at a parking lot paved with asphalt to observe various meteorological parameters and surface temperature from July 1 to September 30, 2014. Since the number of rainy days in summer of 2014 particularly after the mid July is more than that of average data, a ratio of daily peak surface temperature above $45^{\circ}C$ was 28% which was lower than the average. The observational data about hourly average surface temperature and various heat balance factors at days where daily peak surface temperature is above $45^{\circ}C$ are as follows: An hour that had the daily maximum temperature was around 15 pm and the value was $49^{\circ}C$ approximately. Net shortwave radiation was the highest at 12pm as $800W/m^2$ and much radiation of $500W/m^2$ was absorbed at the ground between 11am and 17pm. Sensible heat that was delivered from the ground to the atmosphere was evaluated as $200W/m^2$ between 10am and 19pm. underground transfer heat up to $100W/m^2$ was measured as negative from 19pm to the next day 8am, which indicated the lower atmosphere was heated at night.

A Biopharmaceutical Study on Rifampicin-Polyvinylpyrrolidone Coprecipitate (Rifampicin-Polyvinylpyrrolidone 공침물에 관한 생물약제학적 연구)

  • 김영일
    • YAKHAK HOEJI
    • /
    • v.23 no.2
    • /
    • pp.81-94
    • /
    • 1979
  • Rifampicin-polyvinylpyrrolidone coprecipitates were prepared by the solvent method to increase the solubility and dissolution rate, thereby improving absorption of rifampicin. It was found that the solubility and dissolution rate were greater with the 1 : 5 (w/w) coprecipitate than with the pure drug, physical mixtures or coprecipitates of any other ratio of the two components. The blood concentration data in non-fasted rats showed that the extent of absorption of rifampicin were significantly enhanced following the oral administration of the 1 : 5 coprecipitate; The area under the serum concentration curve (0-8hr) was 1.3 times greater with the 1 : 5 coprecipitate than with the pure drug. The blood concentration reached its peak (4. 38$\pm$1.36mcg/ml) within two hours in the case of oral administration of the 1 : 5 coprecipitate and, on the other hand, it reached the maximum (3.77$\pm$0.90mcg/ml) after four hours of oral administration of the pure drug. It was observed that there was no significant difference between the 1 : 5 coprecipitate and the pure drug in the extent and rate of absorption of rifampicin when fasted rats were used. When the 1 : 5 coprecipitate was orally administered to human subjects 20 minutes after meal, it was found that the blood concentration reached the maximum after one hour; in the case of the pure drug, it reached its peak after four hours.

  • PDF

Evaluation of Thermal Degradation of 2.25Cr-1Mo Steel Using Ultrasonic Nonlinear Effect and X-ray Diffraction Method (초음파 비선형 음향 효과 및 X-선 회절법을 이용한 2.25Cr-1Mo 강의 열화 손상 평가)

  • Kim, Duk-Hee;Park, Un-Su;Park, Ik-Keun;Byeon, Jai-Won;Kwun, Sook-In
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.71-79
    • /
    • 2002
  • It was attempted to evaluate the degree of degradation of thermally aged 2.25-1Mo steek by ultrasonic monlinear parameter(UNP) measurement and X-ray diffraction analysis of extracted carbide. Artificial aging was performed to simulate the microstructural degradation in 2.25Cr-1Mo steel arising from long time exposure at $540{\circ}C$. Microstructural analysis (number of carbides per unit area) and measurements of mechanical properties(Vickers hardness, DBTT) and degradation evaluation parameters(UNP and intensity ration of X-ray diffraction peak of electrolytically extracted carbide) were performed. Both of UNP and intensity ratio of X-ray diffraction peak for M6C carbide to that of M23C6 carbide(IR) increased abruptly in the initial 1000 hour of aging and then changed little. UNP and IR were proposed as potential parameters to evaluate the degree of aging degradation of 2.25Cr-1Mo steel.

The structure and the surface composition of semiconductor CdZnTe films by EBE (EBE로 증착된 반도체 CdZnTe 박막의 결정구조와 표면조성)

  • 박국상;김선옥;이기암
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.5 no.1
    • /
    • pp.25-36
    • /
    • 1995
  • We have investigated the structure and the conductivity of the $Cd_{1-y}Zn_{y}$ Te films evaporated on the glass substrates (Corning 7059) by Electron Beam Evaporator (EBE) in pressure of approximately $1 {\times} 10^{-6}$ torr.The structure temperatures were held at both room temperature and $300^{\circ}C$, and the samples have annealed for an hour at $300^{\circ}C$ The survace com-position of the as-prepared films were slightly different from those of CdZn Te source material.Cd losses on the CdZnTe surface was measured about 4% of atomic ratio at room temperature substrate, whereas Zn atomic ratio was nearly constant, relatively. The strure is observed to be polycrystalline whose phase is mainly cubic phase. Thermal expansion coefficient was $6.30 {\times} 10^{-5}/^{\circ}C$ which was calculated from the variation of lattice parameter by X-ray powder pat-terns measured at $400^{\circ}C$.Diffraction peaks were slightly increased by annealing for an hour at $300^{\circ}C $, but they werey highly affected by substrate temperature during evaporation.

  • PDF

Ex Vivo Lung Perfusion of Cardiac-death Donor Lung in Pigs

  • Paik, Hyo Chae;Haam, Seok Jin;Park, Moo Suk;Song, Joo Han
    • Korean Journal of Transplantation
    • /
    • v.28 no.3
    • /
    • pp.154-159
    • /
    • 2014
  • Background: Lung transplantation (LTx) is a life-saving treatment for patients with end-stage lung disease; however, the shortage of donor lungs has been a major limiting factor to increasing the number of LTx. Growing experience following LTx using donor lungs after cardiac death (DCD) has been promising, although concerns remain. The purpose of this study was to develop a DCD lung harvest model using an ex vivo lung perfusion (EVLP) system and to assess the function of presumably damaged lungs harvested from the DCD donor in pigs. Methods: The 40 kg pigs were randomly divided into the control group with no ischemic lung injury (n=5) and the study group (n=5), which had 1 hour of warm ischemic lung injury after cardiac arrest. Harvested lungs were placed in the EVLP circuit and oxygen capacities (OC), pulmonary vascular resistance (PVR), and peak airway pressure (PAP) were evaluated every hour for 4 hours. At the end of EVLP, specimens were excised for pathologic review and wet/dry ratio. Results: No statistically significant difference in OC (P=0.353), PVR (P=0.951), and PAP (P=0.651) was observed in both groups. Lung injury severity score (control group vs. study group: 0.700±0.303 vs. 0.870±0.130; P=0.230) and wet/dry ratio (control group vs. study group: 5.89±0.97 vs. 6.20±0.57; P=0.560) also showed no statistically significant difference between the groups. Conclusions: The function of DCD lungs assessed using EVLP showed no difference from that of control lungs without ischemic injury; therefore, utilization of DCD lungs can be a new option to decrease the number of deaths on the waiting list.