• Title/Summary/Keyword: Peak voltage detection method

Search Result 27, Processing Time 0.038 seconds

A Single-Phase Quasi Z-Source Dynamic Voltage Restorer(DVR) (단상 Quasi Z-소스 동적전압보상기(DVR))

  • Lee, Ki-Taeg;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.327-334
    • /
    • 2010
  • This paper deals with a single-phase dynamic voltage restorer(DVR) with a quasi Z-source topology. The proposed system based on a single-phase quasi Z-source PWM ac-ac converter which have features such as the input voltage and output voltage are sharing ground, and input current operates in continuous current mode(CCM). For the detection of voltage sag-swell, peak voltage detection method is applied. Also, the circuit principles of the proposed system are described. During the 60% severe voltage sag and 30% voltage swell, the proposed system controls the adding or missing voltage and maintains the rated voltage of sinusoidal waveform at the terminals of the critical loads. Finally, PSIM simulation and experimental results are presented to verify the proposed concept and theoretical analysis.

A Series Arc Fault Detection Strategy for Single-Phase Boost PFC Rectifiers

  • Cho, Younghoon;Lim, Jongung;Seo, Hyunuk;Bang, Sun-Bae;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1664-1672
    • /
    • 2015
  • This paper proposes a series arc fault detection algorithm which incorporates peak voltage and harmonic current detectors for single-phase boost power factor correction (PFC) rectifiers. The series arc fault model is also proposed to analyze the phenomenon of the arc fault and detection algorithm. For arc detection, the virtual dq transformation is utilized to detect the peak input voltage. In addition, multiple combinations of low- and high-pass filters are applied to extract the specific harmonic components which show the characteristics of the series arc fault conditions. The proposed model and the arc detection method are experimentally verified through a boost PFC rectifier prototype operating under the grid-tied condition with an artificial arc generator manufactured under the guidelines for the Underwriters Laboratories (UL) 1699 standard.

Dynamic Response Improvement of Stand Alone Engine-Generator System using Double Voltage Detection Method (전압 이중 검출법에 의한 독립형 엔진-발전기 시스템 응답특성 개선)

  • Lee, Dong-Hee;Ahn, Jin-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1195-1199
    • /
    • 2008
  • In this paper, peak detector of generator's output voltage and variable gain controller are introduced for a fast dynamic response. The conventional r,m.s, signal detected has inherent time delay, and the dynamic response of generator using conventional PID controller has some problem in sudden load change. In this paper, the peak detector and signal selector with variable gain controller is used to overcome this problem. The main controller can check the voltage state from the peak detector. When a sudden load change, the over-voltage and under-voltage signal from peak detector change the controller's gain and exciter's current reference. The proposed scheme can improve the dynamic response, which is verified from experimental test of 200kW diesel engine-generator.

A Study on the Design of the Dynamic Voltage Restorer Prototype (Dynamic Voltage Restorer Prototype 설계에 관한 연구)

  • Kim, Ji-Won;Chun, Yeong-Han;Jeon, Jin-Hong;Oh, Tae-Kyoo;Park, Dong-Wook
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.3
    • /
    • pp.140-145
    • /
    • 2001
  • The instantaneous voltage drop is occurred when the fault is happened on the nearby feeders. The instantaneous voltage drop is continued during relatively short period. But, the effect of it can be very severe to some sensitive devices. That is, it can be the reason of restart or malfunction of some devices. And these phenomenons can cause the enormous economical damage and shorten the lifetime of the devices. In this paper, the device which can compensate the instantaneous voltage drop, is studied. Through the computer simulation using PSCAD/EMTDC, the validity of the control algorithm using peak detection method is verified. And the Dynamic Voltage Restorer(DVR) prototype is designed and constructed. Through the experiment, the function and performance of the DVR prototype is verified.

  • PDF

A Detection Scheme of a Secondary Arc Extinction Using Correlation of a Fault Voltage (고장 전압의 correlation을 이용한 2차 아크 소호 판별)

  • Jang, Won-Hyeok;Seo, Hun-Chul;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.340_341
    • /
    • 2009
  • This paper suggests a detection scheme of a secondary arc extinction using the peak value of a fault voltage estimated by correlation algorithms. The system implemented in this paper is based on a Korean 765 kV system and the suggested proposed scheme is tested on the system. The performance of the method is analyzed by using Electro-Magnetic Transients Program (EMTP)/ATPDraw.

  • PDF

A Study on Accuracy Detection Method for Signal Peak Voltage (신호용 PEAK 전압 정밀검출에 관한 연구)

  • Park, Ho-Chul;Sung, Hyung-Su;Han, Seung-Moon;Han, Jeong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2528-2530
    • /
    • 2000
  • In general, Diode makes a major role in electronic circuit. For example, switching of rectifier, cross current of switching rectifier, energy transfer of electronic element and reverse charge of capacitor, voltage insulation, energy feedback from load to power supply, and such as recovery of storaged energy. Generally, We regard power diode as ideal element, but it has a certain boundary actually, specially, We use diode for detecting circuit peak hold voltage signal. It has cut in voltage. It occurs error of measurement value namely. This error, below in region diode voltage drop (0.7v) measurement value is wholesome signal, Specially, We can not get precision data. Therefore, precision level is low between theoretical and measurement data because of error in actual circuit. Conclusionally, In this paper, We define the error concerning to the power diode characteristics which is used detecting of the minute signal, and recommend the method that minimize measurement error.

  • PDF

Design of radiation detection circuit for gamma column scanning (자동 감마 증류탑 검사 장치를 위한 방사선 계측장치 설계)

  • Kim, Jong-Beom;Jeong, Seong-Hui
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.612-615
    • /
    • 2003
  • In this paper, a design of radiation detector for gamma column scanner is introduced. Distillation column is important unit in Petro-chemical industries, and its on-line diagnose is very important. To get density profile measured by the radiation transmitted through column is well method for on-line diagnose as gamma scanning. For this purpose radiation detection circuit, radiation source and mechanical system for moving source and detector are required. Conventional radiation detection circuit for this application is sensitive to electric noise because of interface between the radiation circuit and the controller for mechanical system. The radiation detection system introduced here is using loop coil instead of slip ring to remove contact noise. Radiation detection system designed here for gamma scanning consist of BGO detector, high voltage circuit, PHA circuit and FSK modem. The BGO detector is used as radiation sensor, high voltage circuit and peak height analysis circuit is essential to process the signal generated from BGO detector. Micro controller convert measured data into ASCII data. FSK modem transmit ASCII data. Transmitted ASCH data is picked up in antenna coil and processed for combined function with mechanical system. This method gives good result by isolating the controlling circuit of mechanical system from radiation detecting circuit which is sensitive to noise.

  • PDF

Dynamic Voltage Restorer(DVR) with a Z-Source AC Converter Topology (Z-소스 교류 컨버터 토폴로지의 동적 전압 보상기)

  • Lim, Young-Cheol;Jung, Young-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.36-43
    • /
    • 2010
  • This paper proposes a new type of voltage sag-swell compensator based on a Z-source AC-AC converter. The proposed topology employs a pulse width modulation (PWM) Z-source AC-AC converter along with a injection transformer. A safe commutation strategy is used to eliminate voltage spikes on switches without snubber circuit. During a voltage sag or swell, the proposed system controls the adding or missing voltage and maintains the rated voltage of sinusoidal waveform at the terminals of the critical loads. The proposed system is able to compensate 20[%] voltage swell and is also able to compensate 60[%] voltage sag. In order to control and detect the voltage sag and swell, the peak voltage detection method is applied. Also, the operating principles of the proposed system are described, and a circuit analysis is provided. Finally, PSIM simulation and experimental results are presented to verify the proposed concept and theoretical analysis.

Detection and Location of Cable Fault Using Improved SSTDR (개선된 SSTDR을 이용한 케이블 고장 검출과 위치 계산)

  • Jeon, Jeong-Chay;Kim, Jae-Jin;Choi, Myeong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1583-1589
    • /
    • 2016
  • This paper proposes an improved spread spectrum time domain reflectometry (ISSTDR) using time-frequency correlation and reference signal elimination method in order to have more accurate fault determination and location detection than conventional (SSTDR) despite increased signal attenuation due to the long distance to cable fault location. The proposed method has a two-step process: the first step is to detect a peak location of the reference signal using time-frequency correlation analysis, and the second step is to detect a peak location of the correlation coefficient of the reflected signal by removing the reference signal. The proposed method was validated through comparison with existing SSTDR methods in open-and short-circuit fault detection experiments of low voltage power cables. The experimental results showed that the proposed method can detect correlation coefficients at fault locations accurately despite reflected signal attenuation so that cable faults can be detected more accurately and clearly in comparison to existing methods.

Degradation Evaluation of Turbine Rotor Using Magnetic Method (자기적 방법에 의한 터빈 로터강의 열화도 평가)

  • Ryu, K.S.;Park, J.S.;Nahm, S.H.;Kim, Y.I.;Yu, K.M.;Ryu, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1593-1595
    • /
    • 2000
  • We present a new procedure to evaluate the degradation in a lCr-lMo-0.25V steel. The method is based on the existence of the peak of reversible permeability in the differential magnetization around the coercive field strength. The apparatus is based on the detection of the voltage induced in a surface type coil using a lock-in amplifier tuned to a frequency to the exciting one. Results obtained the reversible permeability and Vickers hardness on the annealed samples show the peak interval of reversible permeability and Vickers hardness decreased as ageing time increased. The correlation between Vickers hardness and the peak interval of reversible permeability could well be evaluated non destructively.

  • PDF