• 제목/요약/키워드: Peak pressure

검색결과 1,458건 처리시간 0.03초

강제 입수에 의한 슬래밍 현상에 관한 실험적 연구 (An Experimental Study on Slamming Phenomenon by Forced Impact)

  • 남종오;강효동;정장영;권순홍;최한석
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.392-395
    • /
    • 2006
  • This paper presents the experimental results at slamming phenomenon. The air pressure cylinder was used to ensure repeatability of the impact. The results showed that the adopted experimental technique was very excellent in terms of repeatability when is compared to that of the free drop tests. The pressure time histories, magnitude of peak pressure and the behavior of jet spray were obtained. The flat specimen was tested for various incident angles. To estimate the incident speed of the specimen high speed camera was used. The high speed camera was also useful tool in understanding the behavior.

  • PDF

인체보행 시 양발에 가해지는 압력분포를 통한 자세 뒤틀림 측정 및 분석 (Posture for Distortion Measurement and Analysis Through the Pressure Distribution During a Person Walking)

  • 홍주희;김경호
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.487-492
    • /
    • 2016
  • In this paper, a device for analyzing the pressure distribution during walking was produced by using the pressure sensor on the heel. This device was limited to a frequency band by using the 1st low-pass filter. And an algorithm to analyze the value of the quantity to pressure using a analog to digital converter. It is used by using the threshold voltage of pressure sensor, it is suggested the algorithm. The algorithm is detected the peak which is exceeded the threshold voltage. and thus in accordance, it is detected the number of steps. And the calorie consumption were detected by using it. Also it used an MCU and Bluetooth. And by confirming the data at the LCD of the other MCU, it was to reduce the size of the device. According to this algorithm, it has the advantage that there is no restriction on the activity than when using an imaging device and it is inexpensive than other sensors such as an acceleration sensor or a gyro and it is easy to handle.

제트 편향기에 충돌하는 초음속 제트에 관한 연구 (Study of Supersonic Jet Impinging on a Jet Deflector)

  • 이택상;정조순;신완순;박종호;김윤곤
    • 한국추진공학회지
    • /
    • 제5권3호
    • /
    • pp.10-18
    • /
    • 2001
  • 본 논문은 제트 편향기 기초 설계 자료를 제시하기 위하여 쐐기 형상의 제트 편향기에 충돌하는 초음속 제트에 관한 연구이다. 설계 마하수 2, 초음속 유동장치를 이용하여 초음속 제트가 꼭지각 $90^{\cire}$ 쐐기에 충돌할 때 중심선에서 표면압력분포, 유동 가시화, 압력 등 분포에 대해 실험 연구를 수행하고 유동해석 결과와 비교하였다. 쐐기가 노즐 출구면에 위치할 때는 제트가 충분히 발달하지 못해 과소팽창비의 영향이 없었지만, 노즐 출구로부터 거리가 멀어지면서 과소팽창비가 커지면 쐐기 표면에서 압력 회복율은 저하했다. 압력 등 분포에서는 쐐기 표면에서 최대 압력이 형성된 영역을 확인하였다.

  • PDF

인체계측 모델을 이용한 욕창방지용 공기셀 매트리스의 개발 (Development of Air-cell Mattress for Preventing Pressure Ulcer Using Anthropometric Model)

  • 강성재;김규석;홍정화;류제청;김경훈;문무성;문인혁
    • 제어로봇시스템학회논문지
    • /
    • 제11권7호
    • /
    • pp.578-586
    • /
    • 2005
  • Air mattress is now used widely to prevent the pressure ulcer by reducing the localized pressure peaks. The pressure control method based on the anthrophometric model of an air-cell mattress developed in this study is presented. The air-cell mattress has 18 cylindrical air cells made of porous material allowing air leakage. Even though the air leakage can contribute to reducing the development of pressure ulcer by lowering the pressure peak, temperature and humidity, the air pressure changes with time and the desired air-cell pressure has to be determined as an optimal value for each user. To select the desired air-cell pressure, we first divide the parts of the body into four sections such as head, trunk, hip, and leg. Then, the pressure of each section grouped with air-cells is calculated from the weight of each part estimated from the individual height and body weight. Air supply system for the air-cell mattress is implemented by using four electronic solenoid valves and an air compressor, and it is driven by a real-time microcontroller. We experimented with five subjects of the contact pressure on skin. The experimental results show that the proposed air-cell mattress is effective for the prevention of the pressure ulcer.

기능성 인솔과 일반 인솔의 발에 대한 접촉 면적, 최대 압력, 최대 평균압력 및 최대 힘 비교 (Comparison of the Contact Area, Maximum Pressure, Maximum Average Pressure and Maximum Force between Functional Insoles and General Insoles)

  • 이수경
    • PNF and Movement
    • /
    • 제20권3호
    • /
    • pp.431-441
    • /
    • 2022
  • Purpose: The purpose of this study was to compare the changes in the contact area, maximum pressure, maximum mean pressure, and maximum force of functional insoles and general insoles when walking. Methods: Foot pressure was measured by the ignition of functional insoles and general insoles on Company N shoes. The foot pressure was measured using a precision pressure distribution meter (Pedar - X mobile system, Novel, Germany). Each insole sensor contained 99 independent cells and was inserted between the foot and the shoe. A wireless Bluetooth-type program was used to measure the pressure detected by the measuring insoles. In order to eliminate adaptation and fatigue caused by wearing the guide during the experiment, sufficient rest was taken between each experiment, and the wearing order was randomly selected. Results: Functional insole significantly increased the forefoot and midfoot (medial, lateral) (p<0.05), while total foot, forefoot, and rearfoot peak pressure significantly decreased (p < 0.05) compared to the general insole. Conclusion: In the functional insole, a high contact area was measured inside, even in the middle of the foot, leading to a proper change in foot pressure. It was confirmed that the contact area was reduced and dispersion occurred well. In addition, it was found that the maximum pressure in the front and back of the entire foot was reduced, so the weight pressure dispersion in the functional insole was evenly distributed, and the maximum average pressure change was similar.

DPF의 유동특성에 관한 과도해석 연구 (Study on Transient Analysis for Flow Characteristics in DPF)

  • 신동원;윤천석
    • 한국자동차공학회논문집
    • /
    • 제18권1호
    • /
    • pp.131-138
    • /
    • 2010
  • Because real flow of engine exhaust is very hot and highly transient, it may cause thermal and inertial loads on catalyzed filters in DPF. Transient and detailed flow and thermal simulations are necessary in this field. To assess the importance of time dependent phenomena, typical cone-type configuration such as an underbody DPF is selected for steady and transient analysis. User defined functions of FLUENT by sinusoidal inlet velocities are written and integrated with main solver for realistic simulation. Also, 4-cylinder and 6-cylinder engines for 3,000 L class are considered for the dynamic exhaust effect of engine type. Key parameters to understanding of catalyst performance and durability issues such as flow uniformity index and peak velocity are investigated. Also, pressure drop for engine power are considered. From the simulation results for three different cases, proper approach is recommended.

Ultrasonic Evaluation of Interfacial Stiffness for Nonlinear Contact Surfaces

  • Kim, Noh-Yu;Kim, Hyun-Dong;Cho, Youn-Ho
    • 비파괴검사학회지
    • /
    • 제28권6호
    • /
    • pp.504-511
    • /
    • 2008
  • This paper proposes an ultrasonic measurement method for measurement of linear interfacial stiffness of contacting surface between two steel plates subjected to nominal compression pressures. Interfacial stiffness was evaluated by using shear waves reflected at contact interface of two identical solid plates. Three consecutive reflection waves from solid-solid surface are captured by pulse-echo method to evaluate the state of contact interface. A non-dimensional parameter defined as the ratio of their peak-to-peak amplitudes are formulated and used to calculate the quantitative stiffness of interface. Mathematical model for 1-D wave propagation across interfaces is developed to formulate the reflection and transmission waves across the interface and to determine the interfacial stiffness. Two identical plates are fabricated and assembled to form contacting surface and to measure interfacial stiffness at different states of contact pressure by means of bolt fastening. It is found from experiment that the amplitude of interfacial stiffness is dependent on the pressure and successfully determined by employing pulse-echo ultrasonic method without measuring through-transmission waves.

고전압 COS 퓨즈로부터 방사된 충격성 소음의 지속시간 제어에 관한 실험적 연구 (An Experimental Study on the Control of Duration time of Impulse Noise from a High Voltage COS Fuse)

  • 송화영;김덕한;이종석;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.258-261
    • /
    • 2006
  • This study introduces the control of duration time of impulse noises emitted from a high voltage COS fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the peak sound pressure level over 150 dB(A) is generated at the distance of 2m from a COS Fuse. For the purpose of the reduction of impulse noise, in this study, the reactive type silencer has been utilized. And also electrical interrupting test was experimented. From the experimental results, the reactive type silencer has been shown to have the noise reduction of about 13 dB(A). It has been found that the electrical interception performance of the COS fuse was related to the control of the duration time of impulse noise.

  • PDF

심실의 부하감소 측면에서 좌심실 보조장치의 최적 치료시기 예측을 위한 시뮬레이션 연구 (Prediction of Pumping Efficacy of Left Ventricular Assist Device according to the Severity of Heart Failure: Simulation Study)

  • 김은혜;임기무
    • 한국기계가공학회지
    • /
    • 제12권4호
    • /
    • pp.22-28
    • /
    • 2013
  • It is important to begin left ventricular assist device (LVAD) treatment at appropriate time for heart failure patients who expect cardiac recovery after the therapy. In order to predict the optimal timing of LVAD implantation, we predicted pumping efficacy of LVAD according to the severity of heart failure theoretically. We used LVAD-implanted cardiovascular system model which consist of 8 Windkessel compartments for the simulation study. The time-varying compliance theory was used to simulate ventricular pumping function in the model. The ventricular systolic dysfunction was implemented by increasing the end-systolic ventricular compliance. Using the mathematical model, we predicted cardiac responses such as left ventricular peak pressure, cardiac output, ejection fraction, and stroke work according to the severity of ventricular systolic dysfunction under the treatments of continuous and pulsatile LVAD. Left ventricular peak pressure, which indicates the ventricular loading condition, decreased maximally at the 1st level heart-failure under pulsatile LVAD therapy and 2nd level heart-failure under continuous LVAD therapy. We conclude that optimal timing for pulsatile LVAD treatment is 1st level heart-failure and for continuous LVAD treatment is 2nd level heart-failure when considering LVAD treatment as "bridge to recovery".

폐동맥고혈압을 동반한 심실중격결손증 환자의 폐세동맥의 형태학적 고찰 (Morphological study of pulmonary arterioles in patients with ventricular septal defect associated with pulmonary hypertension)

  • 조범구
    • Journal of Chest Surgery
    • /
    • 제17권3호
    • /
    • pp.339-345
    • /
    • 1984
  • Thirty four patients with a ventricular septal defect, aged 2 months to 24 years [median 2.33 years], had lung biopsies during open heart procedures to assess the degree of pulmonary vascular disease. The patients were divided into two groups according to their age; group 1 - under 2 years of age [15 patients], and group 2- over 2 years of age [19 patients]. The, pathologic change of the pulmonary arterioles was correlated with pre-operative hemodynamic data in 34 patients. There was no significant correlation between the severity of pulmonary vascular disease according to Heath-Edwards classification and the patients age [X2=1.8381, P=0.1751 ]. There was a significant correlation between degree of medial wall thickness and arteriolar diameter and the level of preoperative peak pulmonary artery pressure and peak systemic artery pressure [Pp/Ps]. Also, there was a good correlation between the preoperative pulmonary vascular resistance and systemic vascular resistance [Rp/Rs]. There was no significant correlation between wall thickness and Pp/Ps, and Rp/Rs below the age of 2 years. We conclude that, in patients over 2 years of age, there was a significant correlation between the medial wall thickness of the pulmonary arteriole and elevation of Pp/Ps and Rp/Rs. This is not true in patients under 2 years of age.

  • PDF