• Title/Summary/Keyword: Peak detection algorithm

Search Result 191, Processing Time 0.026 seconds

A Study on the Technology Measuring Partial Discharge for Long Term Aging Experiments of Insulation Materials (장시간 절연체 열화실험을 위한 부분방전측정기술 연구)

  • Seon, Jong-Ho;Kim, Gwang-Hwa;Park, Jeong-Hu;Jo, Jeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.12
    • /
    • pp.665-672
    • /
    • 2000
  • This paper described the measurement technology to analyze the partial discharge characteristics for long term aging of insulations. This system was consisted of high voltage generation and measurement part, PD detection part, digital conversion and signal processing part. We used the VXI system for digital conversion and signal processing part. In the digital conversion part, we studied the error of partial discharge magnitude and memory capacity for reading digital signal with the sampling rate. In the signal processing part, we showed the program algorithm to count pulses and read peak values of partial discharge. The allowable minimum sampling rate of digizer was decided to 250kS/s through analyzing test. We confirmed that this system was very useful in the study of $\phi-q-n$ characteristics of long term PD experiments with specimens being consisted of internal void defects and CIGRE II electrodes.

  • PDF

Implementation and evaluation of the BCG measurement system for non-constrained health monitoring (무구속 건강모니터링을 위한 심탄도 계측 시스템 구현 및 평가)

  • Noh, Yun-Hong;Jeong, Do-Un
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.8-16
    • /
    • 2010
  • This research proposes measuring of BCG(ballistocardiogram) to monitor heart activities in a non-constrained environment, at home or work. Unlike with ECG, measuring BCG does not require the attachment of leads on the subject's body and allows signal measuring in a non-constrained state. It enables effective long-term monitoring of cardiac conditions. In this study a chair type BCG measurement system to continuous monitor the activity of the heart is implemented. The instrument consists of upper petal and ready for press of chair load cell sensor is attached to measure the change of the object's weight. In order to extract the output ballistic signal from the weight and force sensor signals. Beside the signal processing circuit for the digital conversion, the ballistic signal is detected using DAQ equipment. Signal processing algorithm including wavelet transforms for noise cancellation, template matching for normalization and peak detection in BCG is developed. ECG and BCG were concurrently measured to evaluate the performance of the system, and comparing the characteristics of the two signals verified the possibility of the system in non-constrained and nonconscious health monitoring.

A Study on the Instantaneous Voltage Drop Compensator through the Series Voltage Injection (직렬 전압주입에 의한 순간전압강하 보상기기에 관한 연구)

  • 전영환;김지원;전진홍
    • Journal of Energy Engineering
    • /
    • v.10 no.4
    • /
    • pp.310-317
    • /
    • 2001
  • The instantaneous voltage drop is occurred when the fault is happened on the nearby feeders. The instantaneous voltage drop is continued during relatively short period. But, the effect of it can be very severe to some sensitive devices. That is, it can be the reason of restart or malfunction of some devices. And these phenomenons can cause the enormous economical damage and shorten the lifetime of the devices. In this paper the device which can compensate the instantaneous voltage drop, is studied. The device injects the voltage to the power system through the series transformer. The validity of the proposed algorithm using peak detection method is verified through the computer simulation and experiments.

  • PDF

Blood Pressure Measurement using the Modified Step-wise Deflation Method (개선된 계단 배기 방법을 이용한 혈압 측정)

  • Oh, Hong-Sic;Lee, Jong-Shill;Chee, Young-Joon;Kim, In-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.351-358
    • /
    • 2010
  • In the automatic non-invasive blood pressure measurement device, the oscillometric method iswidely used. In the oscillometric method, the step-wise deflation has the advantage of the robustness for the motion artifacts than the linear deflation method. But it has the disadvantage of its longer measurement time because we need to detect two or more pulses in a certain cuff pressure step. In this study, we suggest the modified step-wise deflation method to overcome this limitation while maintaining the general concept of step-wise deflation. Using one valid pulse in each step and the deflating valve control during the diastolic period, the measurement time could be reduced. In order to verify the accuracy of the proposed algorithm, we compared the blood pressure values from the suggested method and the blood pressure values from the conventional auscultation method. The mean and standard deviation were -0.50${\pm}$5.3mmHg and 2.08${\pm}$4.75mmHg, for systolic and diastolic blood pressure respectively. The measurement time can be reduced up to the half of conventional step-wise deflation method.

A Real Time Heartbeat Rate Estimation Algorithm Using PPG Signals (광용적맥파를 이용한 실시간 맥박 검출 알고리듬)

  • Kim, Chisung;Han, Dong Seog
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.82-87
    • /
    • 2016
  • The photoplethysmogram (PPG) signal is one of the mainly considered bio signals along with the electrocardiogram (ECG) signal. PPG signals can be used to estimate the speed of flow of blood in vein, saturation of peripheral oxygen and etc. The heartbeat rate is a common feature in order to evaluate those checkup lists. To estimate the correct heartbeat rate, dynamic noises must be removed in the PPG signal. Conventionally, the acceleration signal is used to remove dynamic noises. This method, however, increases the computational complexity. In this paper, we proposes a solution that uses only PPG signals to calculate the heartbeat rate, and which can be used as a basement in real-time healthcare solution.

Depth Extraction of Convergent-Looking Stereo Images Based on the Human Visual System (인간시각체계에 기초한 교차시각 스테레오 영상의 깊이 추출)

  • 이적식
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.4A
    • /
    • pp.371-382
    • /
    • 2002
  • A camera model with optical axes parallel has been widely used for stereo vision applications. A pair of input ages are obtained from a convergent-looking stereo camera model based on the human visual system in this per, and each image is divided into quadrant regions with respect to the fixation point. The reasoning of quadrant partitions is based on the human visual system and is proven by a geometrical method. Image patches : constructed from the right and left stereo images. A modified cepstrum filter is applied to the patches and disparity vectors are determined by peak detection algorithm. The three-dimensional information for synthetic ages is obtained from the measured disparity and the convergent stereo camera model. It is shown that the experimental results of the proposed method for various stereo images are accurate around the fixation point like the human visual system.

Measurement Device of Resistive Leakage Current for Arrester Deterioration Diagnosis (피뢰기 열화진단을 위한 저항분 누설전류의 측정장치)

  • 길경석;한주섭;김정배
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.10
    • /
    • pp.469-475
    • /
    • 2003
  • Resistive leakage current flowing ZnO blocks increases with its ages, which is an important indicator of arrester deterioration. However, a complicated circuitry is essential to measure the resistive leakage current included in the total leakage current, and the difficult handling of the measurement makes few applications to the fields. In this paper, we propose a resistive leakage current measurement device which is composed of a current detection circuit and an analysis program operated on a microprocessor. The device samples the input leakage current waveform digitally, and discriminate the zero-cross and the peak point of the waveform to analyze the current amplitude vs. phase. The capacitive leakage current is then eliminated from the total leakage current by using an algorithm to extract the resistive leakage current only. Also, the device can be operated automatically and manually to analyze the resistive leakage current even when the leakage current waveform is distorted due to various types of arrester deterioration. To estimate the performance of the device, we carried out a test on ZnO blocks and lightning arresters. From the results, it is confirmed that the device could analyze most parameters needed for the arrester diagnostics such as total leakage current. resistive leakage current, and the $3^rd$ harmonic leakage current.

The development of Fetal Heart Rate monitoring system based on DSP processor (DSP 프로세서를 이용한 태아심음 및 자궁수축감시장치의 개발)

  • Jnag, D.P.;Kim, K.H.;Lee, Y.H.;Lee, Y.K.;Bak, M.I.;Lee, D.S.;Kim, S.I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.320-324
    • /
    • 1996
  • Digital fetal monitoring system based on the personal computer combined with the digital signal processing board was implemented. The DSP board acquires and digitally processes ultrasound fetal Doppler signal for digital rectification, FIR filtering, autocorrelation function calculation, its peak detection and MEDIAN filtering. The personal computer interfaced with the DSP board is in charge of graphic display, hardcopy, data transmission and on-line analysis of fetal heart rate change including and variability. I used a recursive technique for autocorrelation function computation method and MEDIAN filter which can greatly reduce the amount of calculation and accuracy. I also implemented analysis algorithm of fetal heart rate change based on normal fetal sample data in order to exact diagnosis.

  • PDF

Comparison of Speech Onset Detection Characteristics of Adaptation Algorithms for Cochlear Implant Speech Processor (인공와우 어음처리방식을 위한 적응효과 알고리즘의 음성개시점 검출 특성 비교)

  • Choi, Sung-Jin;Kim, Jin-Ho;Kim, Kyung-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.1
    • /
    • pp.25-31
    • /
    • 2008
  • It is well known that temporal information, i.e speech onset, about input speech can be represented to the response nerve signal of auditory nerve better depending on the adaptation effect occurred in the auditory nerve synapse. In addition, the performance of a speech processor of cochlear implant can be improved by the adaptation effect. In this paper, we observed the emphasis characteristic of speech onset in the recently proposed adaptation algorithm, analyzed the characteristic of performance change according to the variation of parameters and compared with transient emphasis spectral maxima (TESM) is the previous typical strategy. When observing false peaks which are generated everywhere except speech onset, in the case of the proposed model, the false peak were generated much less than in the case of the TESM and it is more distinguishable under noise.

Design of Anti-Islanding Algorithm for Utility interactive Photovoltaic System (계통연계형 태양광 발전시스템에서 역충전방지 알고리즘 설계)

  • Gho, J.S.;Kim, H.S.;Choe, G.H.;Kim, H.S.;Lee, Y.J.;You, G.J.;Song, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.440-442
    • /
    • 1995
  • In a recently as renewable energy source photovoltaic(PV) system using solar energy has been very widely researched because of its pollution-free and infinity. Especially many researches are intensively focused on small scale utility interactive PV system which can use dead space and easily make power stabilized from unstable natural energy source. In this system one of the most important matters is islanding protection. Islanding phenomenon appears when power failure occurs. For the safety of utility interactive PV system must has the function of not only system protection but also detection of islanding. This paper describes parallel operating alghorithm using reactive power variation method and twin peak band pass filter. This alghorithm is verified useful by simulation.

  • PDF