• Title/Summary/Keyword: Peak control

Search Result 2,181, Processing Time 0.027 seconds

Statistical Analysis of the Performance Reliability Data for Stroke Patients (뇌졸중 환자 운동신뢰성 측정치의 통계적 분석)

  • Byun, Jae-Hyun;Lee, Seung-Mi
    • Journal of Applied Reliability
    • /
    • v.16 no.1
    • /
    • pp.64-70
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate performance reliability of stroke patients using kinematic analysis. Methods: A protocol to evaluate performance reliability was performed for three tasks on 20 stroke patients and 10 normal people. The tasks include hand to head (HH) task, hand to mouth (HM) task, and hand to target (HT) task. Results: The affected arms showed smaller joint angle, slower peak velocity, longer time to peak velocity for task performances than control group. Also, slower peak velocity and longer movement time for task performance in unaffected arm of stroke patients were obtained compared with the control group. Conclusion: Kinematic analysis is very useful quantitative tool to provide understanding on upper extremity function of stroke patients.

Restarting Trains Under Moving Block Signaling - An Expert System Approach

  • K, K.-Wong;Akio, Katuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.96.6-96
    • /
    • 2001
  • A high peak power demand at substations will result under Moving Block Signalling (MBS) when a dense queue of trains begins to start from a complete stop at the same time in an electrified railway system. This may cause the power supply interruption and in turn affect the train service substantially. In a recent study, measures of Starting Time Delay (STD) and Acceleration Rate Limit (ARL) are the possible approaches to reduce the peak power demand on the supply system under MBS. Nevertheless, there is no well-defined relationship between the two measures and peak power demand reduction (PDR). In order to attain a lower peak demand at substations on different traffic conditions and system requirements, an expert system is one of the possible approaches to procure the appropriate use of peak demand reduction measures ...

  • PDF

Development of Daily Peak Power Demand Forecasting Algorithm using ELM (ELM을 이용한 일별 최대 전력 수요 예측 알고리즘 개발)

  • Ji, Pyeong-Shik;Kim, Sang-Kyu;Lim, Jae-Yoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.4
    • /
    • pp.169-174
    • /
    • 2013
  • Due to the increase of power consumption, it is difficult to construct an accurate prediction model for daily peak power demand. It is very important work to know power demand in next day to manage and control power system. In this research, we develop a daily peak power demand prediction method based on Extreme Learning Machine(ELM) with fast learning procedure. Using data sets between 2006 and 2010 in Korea, the proposed method has been intensively tested. As the prediction results, we confirm that the proposed method makes it possible to effective estimate daily peak power demand than conventional methods.

Peak Load Compensation Control Method of 10kW Rapid charger for Electric Vehicle (V2G를 고려한 전기자동차용 충전기의 피크부하보상 제어 기법)

  • Choi, Seong-Chon;Choi, Ga-Gang;Jung, Doo-Young;Lee, Woo-Won;Lee, Su-Won;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.150-151
    • /
    • 2012
  • The utility grid has a supply of electric energy which is larger than the usually required power consumption under peak load condition. So, power distribution is required to have a heavy capacity because of peak-load period. To solve the problem, this paper proposes a 10kW rapid charger system which has a function of load compensation at the peak-load condition. The proposed system supplies power demanded by peak-load through transferring energy in the battery of electric vehicle to the grid. V2G operation is verified through simulation performed by 10kW rapid-charger.

  • PDF

The Immediate Effects of Unilateral Contract-Relax Stretching on Contralateral Knee Extension Range -A Preliminary Study- (한쪽 다리에 적용한 수축-이완 기법이 반대쪽 무릎관절 폄 범위에 미치는 효과 -예비연구-)

  • Shin, Seung-Sub
    • PNF and Movement
    • /
    • v.17 no.2
    • /
    • pp.263-274
    • /
    • 2019
  • Purpose: This article was conducted to determine the immediate effects of unilateral contract-relax (CR) stretching on contralateral knee extension range and to compare both sides of the knee extension range between experimental and control groups. Methods: This study recruited 16 adult males and females with straight leg raising abilities below $90^{\circ}$. The subjects were randomly divided into an experimental group and a control group comprising 8 subjects each. The experimental group performed direct CR stretching on the right hamstring muscles with straight hip extension adduction, and the control group performed indirect CR stretching on the right hamstring muscles with straight hip flexion abduction. Each group performed CR stretching 4 times with 4 repetitions comprising 10 sec of contraction and a 10 sec break between repetitions. Before and after the CR stretching exercises, the subjects' passive knee extensions were measured at the hip in a $90^{\circ}$ flexed position. The subjects' peak force on the right leg and peak pressure on the left leg during each CR stretching exercise were also measured. Results: After doing CR stretching 4 times, each group showed a significantly increased passive knee extension range on both sides, and there was no difference in the passive knee extension ranges between the groups. The peak force on the right leg was significantly higher in the experimental group than the control group. There was no difference in peak pressure between the groups. Conclusion: After applying unilateral CR stretching, the study subjects experienced a significantly increased passive knee extension range on the contralateral side. For patients who find it difficult to apply stretching techniques to knee joints directly, the use of the proprioceptive neuromuscular facilitation technique of CR stretching may be useful in improving the range of the knee joint on the contralateral side without direct treatment.

Landing with Visual Control Reveals Limb Control for Intrinsic Stability

  • Lee, Aeri;Hyun, Seunghyun;Ryew, Checheong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.3
    • /
    • pp.226-232
    • /
    • 2020
  • Repetition of landing with visual control in sports and training is common, yet it remains unknown how landing with visual control affects postural stability and lower limb kinetics. The purpose of this study was to test the hypothesis that landing with visual control will influence on lower limb control for intrinsic dynamic postural stability. Kinematics and kinetics variables were recorded automatically when all participants (n=10, mean age: 22.00±1.63 years, mean heights: 177.27±5.45 cm, mean mass: 73.36±2.80 kg) performed drop landings from 30 cm platform. Visual control showed higher medial-lateral force, peak vertical force, loading rate than visual information condition. This was resulted from more stiff leg and less time to peak vertical force in visual control condition. Leg stiffness may decrease due to increase of perturbation of vertical center of gravity, but landing strategy that decreases impulse force was shifted in visual control condition during drop landing. These mechanism explains why rate of injury increase.

The Study on the Field test and Operational Method of a Direct Load Control System for Air conditioner (에어컨부하 직접제어시스템 실증시험 및 운용방안에 관한 연구)

  • Gang, Won-Gu;Kim, Chung-Hwan;Kim, Myong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2825-2827
    • /
    • 2000
  • In electric power industry. load balance has been one of the most fundamental and important management goals. Therefore. the strategy to achieve high quality load management now includes load balance besides the stabilization of electricity supply and quality management of electricity. Amongst many techniques of load management. direct load management has been actively studied and utilized to increase power facility and peak load suppression. Higher peak load situation is appeared during summer than during winter in Korea. and approximately 20% of the peak load is due to the load for air-conditioning. To cope with this peak load problem during summer KEPCO is performing a research project to develop a system to remotely control air-conditioning load using wireless communication. Currently, applicable facilities are limited to small-scale air-conditioning facility that has less than 2KW power capacity. This paper described the 1st year of efforts made in the study.

  • PDF

Reducing Peak Cooling Demand Using Building Precooling and Modified Linear Rise of Indoor Space Temperature (건물예냉과 실내온도의 선형상승에 의한 피크냉방수요 저감)

  • Lee, Kyoung-Ho;Yang, Seung-Kwon;Han, Seung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.2
    • /
    • pp.86-96
    • /
    • 2010
  • The paper describes development and evaluation of a simple method for determining gradient of modified linear setpoint variation to reduce peak electrical cooling demand in buildings using building precooling and setpoint adjustment. The method is an approximated approach for minimizing electrical cooling demand during occupied period in buildings and involves modified linear adjustment of cooling setpoint temperature between $26^{\circ}C$ and $28^{\circ}C$. The gradient of linear variation or final time of linear increase is determined based on the cooling load shape in conventional cooling control having a constant setpoint temperature. The potential to reduce peak cooling demand using the simple method was evaluated through building simulation for a calibrated office building model considering four different weather conditions. The simple method showed about 30% and 20% in terms of reducing peak cooling demand and chiller power consumption, respectively, compared to the conventional control.

Performence Characteristics and Analysis Effect of Maximum Power Saving Device in Metal Parts Heat Treatment Company (금속 부품 열처리업체의 최대전력절감장치 동작 특성 및 효과 분석)

  • Chang, Hong-Soon;Han, Young-Sub;Hwang, Ik-Hwan;Seo, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.40-44
    • /
    • 2014
  • In this paper, maximum power is the lowering device using the facility's energy use and peak load electricity through analyzing attitude should like to make it reduce its power base rate. Simulator to manage the demand for power, a maximum electric power base power from electronic watt-hour meters by a device's signal, predictive power, the current power by computing the goal of power for less than Maximum peak power and peak shift, so that you can manage, and peak York, which role you want a cut Metal heat treatment result which analyzes the data, demand for electricity company over the years of analyzing the characteristics of each load, and effects and Reducing power consumption device every month identified seven Sequence control to the load system and successful power control is about showing that the defined goals.

Changes of photoluminescence in silicon-oxide films (실리콘산화막의 광루미니센스 변화에 관한 연구)

  • 이재희
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.3
    • /
    • pp.216-220
    • /
    • 2000
  • Photoluminescence (PL) results of $Si^+$-implanted $SiO_2$films on crystalline silicon are reported. Visible and infrared PL are observed for all the samples. The PL spectrums have about 7000 $\AA$, 7400 $\AA$ and 8400 $\AA$ peak positions. As amount of $Si^+$ ion dose changed, the PL peak positions and intensity are changed. In particular, the PL spectrum has three peaks and more intensity than the other $Si^+$ ion implantation samples for $1{\times}10^{17}/cm^2$ $Si^+$ ion implantation. Not nanocrystal but defects that $Si^+$ ions treated are contributed to the PL spectrum. For the changes of $Si^+$ ion dose and annealing time, O rich radiative defects, Si rich radiative defects, and nonradiative defects control the PL spectrum. We confirmed that more radiative defects can be created by control of $Si^+$ ion dose.

  • PDF