• Title/Summary/Keyword: Peak Flow Ratio

Search Result 195, Processing Time 0.027 seconds

A Study on the Flame Structure and NOx Distribution In Coaxial Diffusion Combustor (동축확산연소기 화염구조와 NOx 분포에 관한 연구)

  • Kim, K.S.;Lee, W.S.;Kang, I.G.;Lee, D.H.
    • Journal of the Korean Society of Combustion
    • /
    • v.4 no.2
    • /
    • pp.35-41
    • /
    • 1999
  • The purpose of this study is to establish the flame structure and NOx emission characteristics of the swirl flow coaxial diffusion combustion in the model gas turbine combustor. The mean temperature, ion currents and NOx emission measurement technique showed the effect of equivalence ratio into flame length and flame stability. As a result of this study, NOx emission was increased by increasing the equivalence ratio, and the peak value of the NOx was appeared near the flame front.

  • PDF

Numerical analysis of unsteady hydrodynamic performance of pump-jet propulsor in oblique flow

  • Qiu, Chengcheng;Pan, Guang;Huang, Qiaogao;Shi, Yao
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.102-115
    • /
    • 2020
  • In this study, the SST k - ω turbulence model and the sliding mesh technology based on RANS method have been adopted to simulate the exciting force and hydrodynamic of a pump-jet propulsor in different oblique inflow angle (0°, 10°, 20°, 30°) and different advance ratio (J = 0.95, J = 1.18, J = 1.58).The fully structured grid and full channel model have been adopted to improved computational accuracy. The classical skewed marine propeller E779A with different advance ratio was carried out to verify the accuracy of the numerical simulation method. The grid independence was verified. The time-domain data of pump-jet propulsor exciting force including bearing force and fluctuating pressure in different working conditions was monitored, and then which was converted to frequency domain data by fast Fourier transform (FFT). The variation laws of bearing force and fluctuating pressure in different advance ratio and different oblique flow angle has been presented. The influence of the peak of pulsation pressure in different oblique flow angle and different advance ratio has been presented. The results show that the exciting force increases with the increase of the advance ratio, the closer which is to the rotor domain and the closer to the blades tip, the greater the variation of the pulsating pressure. At the same time, the exciting force decrease with the oblique flow angle increases. And the vertical and transverse forces will change more obviously, which is the main cause of the exciting force. In addition, the pressure distribution and the velocity distribution of rotor blades tip in different oblique flow angles has been investigated.

GaN Thin Flims Grown by CVPE(Chloride Vapor Phase Epitaxy) Method (CVPE(Chloride Vapor Phase Epitaxy)법에 의한 GaN 박막성장 연구)

  • 오태효;박범진
    • Korean Journal of Crystallography
    • /
    • v.8 no.2
    • /
    • pp.81-88
    • /
    • 1997
  • We investigated the CVPE grown of GaN thin films on (0001) sapphire using the $GaCl_3$ and $NH_3$ as source gases. The growth temperatures are ranged 970 to $1040^{\circ}C$ with the various flow rate ratio of source gases. The nitridation treatment was performed using the $NH_3$ gas before the GaN deposition. The optimal growth conditions were determined to be; growth temperature of $1040^{\circ}C$, III/V flow rate ratio of 2, nitridation time of 3 min. The FWHM at the (0002) peak from the XRD analysis was shown to be 0.32 deg. for the sample grown under those conditions. The growth rate was about $40{\mu}m/hr$ at $1040^{\circ}C$.

  • PDF

Numerical investigation on VIV suppression of marine riser with triangle groove strips attached on its surface

  • Wang, Wei;Song, Baowei;Mao, Zhaoyong;Tian, Wenlong;Zhang, Tingying
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.2
    • /
    • pp.875-882
    • /
    • 2019
  • The effects of Triangle Groove Strips (TGS) on Vortex-induced Vibration (VIV) suppression of marine riser are numerically investigated using Computational Fluid Dynamics (CFD) method. The range of Reynolds number in simulations is 4.0 × 104 < Re < 1.2 × 105. The two-dimensional unsteady Reynolds-Averaged Navier-Stokes (RANS) equations and Shear Stress Transport (SST) k-ω turbulence model are used to calculate the flow around marine riser. The Newmark-β method is employed for evaluating the structure dynamics of marine riser. The effect of the height ratio (ε) of TGS on VIV suppression is evaluated. The amplitude responses, frequency responses, vortex patterns and the flow around the structures are discussed in detail. With the increase of the height ratio of TGS, the suppression effect of TGS on VIV suppression is improved firstly and then weakened. When ε=0.04, the suppression effect of TGS is the best. Compared with the VIV responses of smooth marine riser, the amplitude ratio is reduced by 38.9%, the peak of the lift coefficient is reduced by 69% and the peak of the drag coefficient is reduced by 40% when Re=6.0 × 104. With the increase of Reynolds number, the suppression effect of TGS on VIV suppression is improved firstly and then weakened. When the Reynolds number is 7.0 × 104, the amplitude ratio can be reduced by 40.1%. As to the large-amplitude vibration cases, the TGS show nice suppression effect on VIV.

An Analysis of Characteristic Parameters for the Design of Detention Pond in Urbanized Area (도시유역에서 저류지 설계를 위한 특성인자 분석)

  • Lee, Jae-Joon;Kim, Ho-Nyun;Kwak, Chang-Jae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.4 s.23
    • /
    • pp.37-47
    • /
    • 2006
  • Urban development results in increased runoff volume and flowrates and shortening in time of concentration, which may cause frequent flooding downstream. Flow retardation structures to limit adverse downstream effects of urban storm runoff are used. There are various types of flow retardation measures include detention basins, retention basins, and infiltration basins. In basic planning phase, a number of planning models of detention ponds which decide storage volume by putting main variables were used to design detention ponds. The characteristics of hydrological parameters $\alpha,\;\gamma$ which are used in planning models of detention pond were analyzed. In this study, detention ponds data of Disaster Impact Assessment report at 22 sites were analyzed in order to investigate correlation between characteristic of urban drainage basin parameter and characteristics of detention pond parameter due to urbanization effects. The results showed that storage volume was influenced by peak discharge ratio $\alpha$ more than runoff coefficient ratio $\beta$ and peak discharge ratio $\alpha$ was influenced by runoff coefficient ratio $\beta$ less than regional parameter n. Storage ratio was mainly influenced by duration of design rainfall in the case of trapezoidal inflow hydrograph such as Donahue et al. method.

Experimental Analysis of Flow Characteristics around Wind-Turbine Blades (풍력터빈 블레이드 주위 흐름의 유동특성에 대한 실험적 분석)

  • Lee, Jung-Yeop;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.7 no.2
    • /
    • pp.64-71
    • /
    • 2010
  • The flow and noise characteristics of wake behind wind-turbine blades have been investigated experimentally using a two-frame particle image velocimetry (PIV) technique. Experiments were carried out in a POSTECH subsonic large wind-tunnel ($1.8^W{\times}1.5^H{\times}4.3^L\;m^3$) with KBP-750D (3-blade type) wind-turbine model at a freestream velocity of $U_o\;=\;15\;m/s$ and a tip speed ratio $\lambda\;=\;6.14$ (2933 rpm). The wind-turbine blades are connected to an AC servo motor, brake, encoder and torque meter to control the rotational speed and to extract a synchronization signal for PIV measurements. The wake flow was measured at four azimuth angles ($\phi\;=\;0^{\circ}$, $30^{\circ}$, $60^{\circ}$ and $90^{\circ}$) of the wind-turbine blade. The dominant flow structure of the wake is large-scale tip vortices. The turbulent statistics such as turbulent intensity are weakened as the flow goes downstream due to turbulent dissipation. The dominant peak frequency of the noise signal is identical to the rotation frequency of blades. The noise seems to be mainly induced by the tip vortices.

The Effectiveness of VAS for Evaluation of Pulmonary Condition in Postoperative Patients. (수술후 폐기능상태 평가를 위한 시각적 상사척도(VAS)의 효용성에 관한 연구)

  • Lee Young-Ran;Kim Myung-Ja
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.1 no.1
    • /
    • pp.69-76
    • /
    • 1994
  • This study was designed and undertaken to find out the effectiveness of VAS for evaluation of general anesthetic postoperative pulmonary-function. We compared the degree of perceived pulmonary function recovery with peak expiratory flow at postoperative 72 hours of subjects. The subjects of this study were collected 38 patients who had received upper abdominal operation in St. Paul Hospital, Catholic University Medical College, and Kangnam Scared Heart Hospital and Kangdong Scared Heart Hospital, Hallym University. Data collection period was from June 15th, to August 7th, 1992. The degree of pulmonary recovery function was measured with peak expiratory at 72 hours postoperatively. The degree of perceived pulmonary function of the patient was measured with ten points visual analog scale at 72 hours postoperatively. Peak expiratory flow and visual analog score was analyzed with Pearson correlation. Peak expiratory flow was expressed as a ratio of preoperative value. The result was as follows : The recovery of pulmonary function and the degree of perceived pulmonary function of the patient at 72hours postoperatively was revealed high correlation (r=.84). The above result suggested that patients with general anesthetic upper abdominal surgery should evaluate recovery of pulmonary function making use of VAS. We know that VAS is very useful in postoperative patients. We perceived that VAS is to take up a positive attitude of patients. Nurse should furnish the nursing care objectively and scientifically to patients. As VAS was economic and simple, VAS should be adviced for wider application.

  • PDF

Effect of critical flow model in MARS-KS code on uncertainty quantification of large break Loss of coolant accident (LBLOCA)

  • Lee, Ilsuk;Oh, Deogyeon;Bang, Youngseog;Kim, Yongchan
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.755-763
    • /
    • 2020
  • The critical flow phenomenon has been studied because of its significant effect for design basis accidents in nuclear power plants. Transition points from thermal non-equilibrium to equilibrium are different according to the geometric effect on the critical flow. This study evaluates the uncertainty parameters of the critical flow model for analysis of DBA (Design Basis Accident) with the MARS-KS (Multi-dimensional Analysis for Reactor Safety-KINS Standard) code used as an independent regulatory assessment. The uncertainty of the critical flow model is represented by three parameters including the thermal non-equilibrium factor, discharge coefficient, and length to diameter (L/D) ratio, and their ranges are determined using large-scale Marviken test data. The uncertainty range of the thermal non-equilibrium factor is updated by the MCDA (Model Calibration through Data Assimilation) method. The updated uncertainty range is confirmed using an LBLOCA (Large Break Loss of Coolant Accident) experiment in the LOFT (Loss of Fluid Test) facility. The uncertainty ranges are also used to calculate an LBLOCA of the APR (Advanced Power Reactor) 1400 NPP (Nuclear Power Plants), focusing on the effect of the PCT (Peak Cladding Temperature). The results reveal that break flow is strongly dependent on the degree of the thermal non-equilibrium state in a ruptured pipe with a small L/D ratio. Moreover, this study provides the method to handle the thermal non-equilibrium factor, discharge coefficient, and length to diameter (L/D) ratio in the system code.

Runoff Reduction Effect of Rainwater Retentive Green roof (저류형 옥상녹화의 우수유출저감에 대한 연구)

  • Baek, So-Young;Kim, Hyun-Woo;Kim, Mi-Kyeong;Han, Moo-Young
    • KIEAE Journal
    • /
    • v.16 no.1
    • /
    • pp.67-71
    • /
    • 2016
  • Purpose: There is a growing interest in rainwater runoff reduction effect of green roof, as flooding caused by increasing impervious surface is becoming more and more frequent in urban areas. This study was conducted to prove runoff reduction and runoff delay effect of the retentive green roof and to investigate its influencing factors to the rainfall events that occurred in the summer of 2013. Method: The experiment intended to monitor the runoff quantity of the retentive green roof($140m^2$) and normal roof($100m^2$) in #35 building in Seoul National University, Seoul, Korea for 75 days in 2013. Result: On analysis of 9 rainfall events, it showed that the retentive green roof has 24.8~100% of runoff reduction ratio, 21.2~100% of peak flow reduction ratio, 0.5~3.75 hours of peak delay, and $1.8{\sim}7.2m^3$ of retaining capacity in an area of $140m^2$. It shows different results depending on rainfall and antecedent dry days. The results show that runoff reduction effect is effective when the rainfall is less than 50 mm and antecedent dry day is longer than five days on average. By installing retentive green roofs on buildings, it can help mitigate urban floods and rehabilitate urban water cycle.

A Study on the Fetal Umbilical Artery Doppler Blood Flow Velocity Waveforms in Normal Pregnancy (정상 임신에서 Doppler 초음파를 이용한 제대동맥 혈류속도 파형에 관한 연구)

  • Bae, Cheol-Seong;Kwun, Gee-Jin;Lee, Doo-Jin;Park, Yoon-Kee;Lee, Sung-Ho;Cho, Kil-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.1
    • /
    • pp.63-71
    • /
    • 1991
  • Noninvasive techniques for antenatal detection of the fetal development and well-being such as biophysical profile, non-stress and stress test remain major challenges in modem obstetric practice. To obtain and analyze umbilical artery velocity waveform by pulsed-wave doppler ultrasound, a total of 160 determinations were carried out on 157 normal pregnant women between 16th to 41st week gestation. The ratio of peak systolic to end-diastolic flow velocity(S/D ratio), pulsatility index and resistance index were measured as indices of the resistance in feto-placental circulation. The results were as follows : As gestation advances, the, mean values for peak systolic and end-diastolic velocities raised progressively. As gestation advances, the mean values for the S/D ratio declined progressively, exhibiting high diastolic flow velocity caused by low resistance. Pulsatility index, and resistance index were also declined progressively, as gestation advances. The analysis of umbilical artery blood flow velocity waveforms provides a new noninvasive technique to evaluate fetal development and well-being, and may be expected a reliable method for assessment of fetal life.

  • PDF