Enzymatic Synthesis of 2-Phenoxyethanol Galactoside by Whole Cells of ${\beta}$-Galactosidase-Containing Escherichia coli

  • Lee, Hyang-Yeol;Jung, Kyung-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.9
    • /
    • pp.1254-1259
    • /
    • 2014
  • We investigated whether ${\beta}$-galactosidase (${\beta}$-gal)-containing Escherichia coli cells could transfer a galactose to 2-phenoxyethanol, resulting in 2-phenoxyethanol galactoside (PE-Gal). PE-Gal was confirmed by liquid chromatography-mass spectrometry. In addition, we also confirmed that a galactose molecule was covalently bonded with PE during thin-layer chromatography analysis of the ${\beta}$-gal hydrolysate of PE-Gal. The yield for PE-Gal synthesis was about 37.5% (weight basis), which was about 7-8 times greater than that of a previous report. In addition, the concentration of ${\beta}$-gal (0.96 U/ml) used in this PE-Gal synthesis was about 20 times less than that in a previous report.

Development of Heat Plate on Butt Welding for PE pipes (PE 배관 맞대기 융착을 위한 열판의 개발)

  • Jin, Hyeong-Guk;Kim, Jae-Seong;An, Dae-Hwan;Lee, Bo-Yeong
    • Proceedings of the KWS Conference
    • /
    • 2006.10a
    • /
    • pp.292-294
    • /
    • 2006
  • Many processes have been introduced to join PE pipes, but most of these methods have lots of disadvantages such as costs and lack of reliability, etc. Recently due to the benefits of cost, safety and reliability, the butt welding has been paid much attention to joint PE pipes. In case of butt welding, the heat plate which is used to melt PE pipes is the most critical equipment. In this study, after developing the heat plate of new shape, the PE double wall pipes with misalignments were butt-welded by using the conventional and developed heat plates and comparison of weld-zones and tensile test was performed. As the results of tensile test, weld-zones using developed heat plate have strength of $147.7{\sim}251.0%$ of weld-zones using conventional heat plate.

  • PDF

Joining of Polyethylene Polymer by the Ultrasonic Welding (초음파 용접을 이용한 폴리에틸렌 수지의 접합)

  • Lee, Chul-Ku
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.3
    • /
    • pp.73-81
    • /
    • 1997
  • This study was to find the best adhesive condition comparing mechanical property in case of hot-melt adhesion using glue-gun, ultrasonic welding with adhesion and only ultrasonic welding in order to adhere thermoplastic resin of polyethylene (PE) in which reliable adhesion was resulted in case of ultrasonic welding with same materials of PE. The best welding condition were acquired at welding time 1 second, welding pressure 250kPa for PE-PE where welding time and welding pressure were increased in accordance with the increase of material strength. At the best ultrasonic welding conditions, bonding strength of PE-PE welding was about 21MPa of which material have tensile strength of 24MPa. Through the analysis of microscophic test for ultrasonic welding structure, it was distinguished between well welded structure with higher intermolecule flow and bad welded structure with lower flow, of which result is mostly correspond with the result of tensile strength test.

  • PDF

Effects of Covering Materials on Light Environment in Protected Horticulture (시설원예의 피복자재가 광환경에 미치는 영향)

  • 조일환;조삼증;김태영;허노열;권영삼
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1997.05a
    • /
    • pp.87-91
    • /
    • 1997
  • 시설원예의 현대화에 따른 각종 피복자재의 도입ㆍ개발과 시설재배 면적의 급속한 증가로 인해 그에 따른 피복자재의 광환경 특성이 검토되지 않고 피복자재가 이용되고 있다. 따라서 본 연구는 연질필름중 가장 피복재배면적이 많은 PE(Polyethylene)필름과 경질판PC (Polycarbonate), PET (Poyethylene terephthalate), 유리 피복자재의 광환경 개선을 위한 기초 연구로 실시하였다. 1. 피복자재별 광투과율은 PE가 약 80%, 유리가 약 90%로, 유리 온실은 완공후 4년이하 경과했음에도 약 5개월 된 PE 보다 광투과율이 높았다. 2. 피복자재별 광반사율은 PE가 가장 높은 약 3% 였고 PC>PET>유리의 순으로 나타났다. 3. 피복자재별 광흡수율은 PE는 전파장에 걸쳐 고루 흡수되었으나 PC, PET는 자외선의 흡수가 많았다. 4. 피복자재별 토마토 군락내 광분포에서 제 1과방의 광량은 시설내 투과일사의 약 15%정도였다. 5. 피복자재별 토마토엽의 증산속도는 PE가 다소 낮았으나 처리간 큰 차이는 없었다. 6. 수경재배의 토마토의 광합성속도가 토경재배 보다 낮았다.

  • PDF

An Overview of Hangul Handwritten Image Database PE92 (한글 필기체 영상 데이터베이스 PE92의 소개)

  • Kim, D.H.;Bang, S.Y.
    • Annual Conference on Human and Language Technology
    • /
    • 1992.10a
    • /
    • pp.567-575
    • /
    • 1992
  • 한글 문자인식 시스템을 개발하기 앞서 생각해야 할 것이 인식실험에 사용될 문자 데이타를 수집하는 것이다. 이 논문에서는 연구 개발자들에게 문자인식 실험에 필요한 충분한 데이타를 제공하며 필기체 문자 데이타를 표준화하여 문자인식 시스템 상호간의 성능을 객관적으로 평가하기 위하여 한글 필기체 문자 데이터베이스 PE92를 개발하였다. 여기서는 PE92 데이타베이스의 소개로서 먼저 PE92를 수집하는데 있어 고려사항들, 즉 필기자, 수집문자의 수, 수집용지의 규격, 데이타베이스의 저장, 데이타의 압축에 대하여 알아본다. 다음 PE92 데이타베이스의 규격을 알아본다.

  • PDF

SPACE CHARGE IN PE LAMINATE (PE Laminate의 공간전하 형성)

  • Roh, Hong-S.;Lee, Jae-Y.;Han, Jae-H.;Suh, Kwang-S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1428-1430
    • /
    • 1994
  • The accumulation of space charge in PE/PE/PE laminates was investigated using the low density polyethylenes having different melt indices from 0.25 to 45 g/10 min. Both heterocharge and homocharge accumulated in parent polyethylenes depend on the value of melt index. A general rule found in this study was that the heterocharge decreases as the melt index increases and finally the homocharge accumulates when the melt index is very high. Because of this reason, PE laminates showed different charge formation characteristics depending on melt index of polyethylene. Details of up to date results are described in the text.

  • PDF

A Study on Various Parameters of the PE-CVD Chamber with Wafer Guide Ring (웨이퍼 가이드링 적용에 따른 PE-CVD 챔버 변수에 대한 연구)

  • Hyun-Chul Wang;Hwa-Il Seo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.2
    • /
    • pp.55-59
    • /
    • 2024
  • Plasma Enhanced Chemical Vapor Deposition (PE-CVD) is a widely used technology in semiconductor manufacturing for thin film deposition. The implementation of wafer guide rings in PE-CVD processes is crucial for enhancing efficiency and product quality by ensuring uniform deposition around wafer edges and reducing particle generation. On the other hand, to prevent overall temperature non-uniformity and degradation of thin film quality within the chamber, it is essential to consider various parameters comprehensively. In this study, after applying the wafer guide rings, temperature variations and fluid flow changes were simulated. Additionally, by simulating the temperature and flow changes when applied to the PE-CVD chamber, this paper discusses the importance of optimizing variables within the entire chamber.

  • PDF

Microclimate and Crop Growth in the Greenhouses Covered with Spectrum Conversion Films using Different Phosphor Particle Sizes (광전환재 크기가 다른 광전환 필름 피복 온실 내 미기상 및 작물 생육)

  • Park, Kyoung Sub;Kwon, Joon Kook;Lee, Dong Kwon;Son, Jung Eek
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.111-117
    • /
    • 2016
  • The objective of this study was to analyze the microclimate and the growth of tomato and lettuce in the greenhouses covered with spectrum conversion films using different phosphor particles sizes. Two spectrum conversion films using phosphor particles larger than $10{\mu}m$ (Micro-film) and smaller than 500 nm (Nano-film) in radius, and poly-ethylene (PE) film were used in double-layered greenhouses as outer coverings. PE films were used as inner coverings in all the greenhouses. Thickness of the films for inner and outer coverings was 0.06 mm. Tensile strength, elongation, and tearing resistance of the Micro- and Nano-films were not different from those of the PE film. Transmittances at a wavelength of 300-1100 nm were a little higher at the Micro-film and lower at the Nano-film than that of the PE film, respectively. Air temperatures at the Micro- and Nano-films were over $2^{\circ}C$ higher than at the PE film, but no significant difference was observed between the two light conversion films. The soil temperature at the Nano-film was $1.5^{\circ}C$ and $3^{\circ}C$ higher than at the Micro- and PE films, respectively. The yields of tomato at the Micro- and Nano-films were 12% and 14% higher than at the PE film, but no significant difference was observed between the two spectrum conversion films. The total soluble solid showed no significant differences among all the films. The yields of lettuces at the Micro- and Nano-films were 27% and 59% higher than at the PE film. Hunter's red (a) value of the lettuce leaf was the highest at the Nano-film. In this experiment, tomatoes requiring high irradiation were better at the Nano film, while lettuce requiring low irradiation better at the Micro film.

Effects of Ethanol on the Subacute Lead Poisoning in Rats (흰쥐에서 아급성 연중독에 미치는 에탄올의 영향에 관한 연구)

  • 이용욱;박성관;이선동
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.3
    • /
    • pp.56-66
    • /
    • 1995
  • This study was performed to investigate the effects of Ethanol on the lead poisoning in rats. For this experiment, 48 male Sprague-Dawley strain were used. The experimental groups were divided into six: a normal control(Control), 200 mg/kg b.w. lead(Pd), 5% ethanol(E5), 10% ethanol(E10), 200 mg/kg b.w. lead plus 5% ethanol(PE5) and 200 mg/kg b.w. lead plus 10% ethanol(PE10). Lead was dissolved in the distilled water and administered orally. Ethanol was given with drinking water ad libitum. The rats were allocated to each group by 8 and sacrificed for 5 weeks. The results were as follows: 1. The mean body weight of each group were increased constantly in all groups during experimental period, but the values of ethanol treatment groups were higher than that of control (Control), lead treatment group(Pb) (P<0.01). 2. Compared to Control and Pb, the relative weight of liver and brain were increased in all the ethanol fed groups. But the relative weight of organs were not observed significantly. 3. The lead concentration of organs were high in the group treated with lead(Pb, PES, PE10) (P<0.01), and PE5, PE10 were high compared with Pb in brain especially(P<0.01). However, no statistical significance were showed between PE5 and PE10. 4. The concentration of serum ALT was increased by lead plus ethanol (PE5, PE10) significantly (P<0.01). 5. The concentration of Hematocrit, hemoglobin, WBC and RBC were not observed difference significantly in all groups.

  • PDF

QoS Support Mechanisms in Mobile MPLS VPN (이동 MPLS VPN에서의 QoS 지원 방안)

  • Lee Young-seok;Yang Hae-kwon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.1
    • /
    • pp.65-73
    • /
    • 2006
  • Network based VPN(Virtual Private Network) using MPLS(Multiprotocol Label Switching) technology, called PE(Provider Edge router) based MPLS VPN, is regarded as a good solution for intranets or ext3nets because of the low cost and the flexibility of the service provision. In this paper, we describe a mechanism that allows the VPN users to move from one site to another site of the VPN network based on the BGP-E MPLS technology. This mechanism is designed for PE(Provider Edge) routers of the backbone network. PE routers connected to the VPN sites establish a new MPLS path to the mobile node after they detect movement of the mobile VPN node. The new location may belong to the same VPN or to different VPN. We desisted VPN management and control functions of the PE routers in order to interface with the Mobile IP protocol and support the QoS mechanism. The pilot implementation and performance measurement were carried out on a simulation using COVERS tool.