• Title/Summary/Keyword: Pd(100)

Search Result 304, Processing Time 0.034 seconds

Effect of Extraction Temperature and Time on Saponin Composition of Red Ginseng Extract (추출온도(抽出溫度) 및 시간(時間)이 홍삼(紅蔘)엑기스의 사포닌 조성(組成)에 미치는 영향)

  • Sung, Hyun-Soon;Yang, Cha-Bum;Kim, Woo-Jung
    • Korean Journal of Food Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.265-270
    • /
    • 1985
  • The saponin yield and its compositional changes of red ginseng extract (RG-EXT) was investigated during extraction at various temperature for 5 times of 8 hours. The higher temperature resulted an increase in solids yield while the total saponin recovered was decreased, particularly at $100^{\circ}C$. A relatively lower thermal stability was found for protopanaxadiol saponin, one of the saponin fractions, than protopanaxatriol saponin. The compositional ratio of saponin at ginsenoside level was little affected by extraction time. The yields data showed that more than 94% of total saponin was recovered by 3$\sim$4 times of 8 hours extraction. Extraction at $80^{\circ}C$ for 4 times of 8 hours were suggested for preparation of RG-EXT from the result of this work.

  • PDF

A NEW METHOD - REAL TIME MEASUREMENT OF THE INITIAL DYNAMIC VOLUMETRIC SHRINKAGE OF COMPOSITE RESINS DURING POLYMERIZATION (복합레진의 초기 동적 체적 중합수축의 실시간 측정 -새로운 측정장치의 개발에 대한 소고-)

  • 이인복
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.134-140
    • /
    • 2001
  • The polymerization shrinkage of composite resins is an important drawback although the composites have many advantages-more esthetic and conservative than metallic restoratives etc. The purposes of this research were to develop a new measurement method and to manufacture an instrument that can measure the initial dynamic volumetric shrinkage of composite resins during polymerization. The instrument was basically an electromagnetic balance that constructed with a force transducer using position sensitive photo detector(PSPD) and a negative feedback servo amplifier of proportional-derivative(PD) controller. The volumetric change of composites during polymerization was detected continuously as buoyancy change in distilled water by means of Archimedes's principle. It was converted to continuous electrical voltage signal in real time. The signal was properly conditioned and filtered and then it was stored in computer by a data acquisition(DAQ) board. By using this electronic instrument. the dynamic patterns of the polymerization shrinkage of eight commercial(Z-100, DenFil, AeliteFil, Z-250, P-60, SureFil, Synergy compact, and Tetric ceram) composite resins were measured and compared. The results were as follows. 1. From this project of developing instrument, the ability has been achieved that can acquire and process data of electrical signal transformed from various physical phenomenon by using temperature, displacement. photo. and force transducer. As a consequence, the instrumentation and measurement system used to analyze the physical characteristics of various dental materials in dental research field can be designed, manufactured and implemented in lab. 2. This instrument has some advantages. It was insensible to temperature change and could measure true dynamic volumetric shrinkage in real time without complicated process. It showed accuracy and high precision results with small standard deviation. 3. The polymerization shrinkage of composites was significantly different between brands and ranged from 2.47% to 3.89%, The order of polymerization shrinkage was as follows, in order of increasing shrinkage, SureFil, P60, Z250, Z100, Synergy compact. DenFil, Tetric ceram, and AeliteFil. 4. The polymerization shrinkage rate per unit time, dVol%/dt, showed that the instrument can provide an indirect research method for polymerization reaction kinetics.

  • PDF

Phase-Shifting System Using Zero-Crossing Detection for use in Fiber-Optic ESPI (영점검출을 이용한 광섬유형 전자 스페클 패턴 간섭계의 위상이동)

  • Park, Hyoung-Jun;Song, Min-Ho;Lee, Jun-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.516-520
    • /
    • 2005
  • We proposed an efficient phase stepping method for the use in fiber-optic ESPI. To improve phase-stepping accuracy and efficiency, a fiber-optic Michelson interferometer was phase-modulated by a ramp-driven fiber stretcher, resulting in 4$\pi$ phase excursion in the PD interference signal. The zero-crossing points of the signal, which have consecutive $\pi$ phase difference, were carefully detected and used to generate trigger signals for the CCD camera. From the experimental results by using this algorithm, $\pi$/2 phase-stepping errors between the speckle patterns were measured to be less than 0.6 mrad with 100 Hz image capture speed. Also it has been shown that the error from the nonlinear phase modulation and environmental perturbations could be minimized without any feedback algorithm.

The Characteristics of Blood Pressure Control in Chronic Renal Failure Patients Treated with Peritoneal Dialysis (복막 투석중인 만성 신부전 환자의 혈압 조절에 관한 연구)

  • Jung, Hang-Jae;Bae, Sung-Hwa;Park, Jun-Bum;Jo, Kyoo-Hyang;Kim, Young-Jin;Do, Jun-Young;Yoon, Kyung-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.333-341
    • /
    • 1999
  • Background and Methods: In order to evaluate characteristics and modulatory factors of blood pressure in peritoneal dialysis(PD), studies were conducted on the 69 patients who had underwent peritoneal equilibration test(PET). Results: The results were as follows; 1) All patients received an antihypertensive drug before PD, but, 15 of 69 patients successfully quit taking the antihypertensive drug after peritoneal dialysis. 2) During peritoneal dialysis, mean arterial pressure(MAP) was significantly decreased for the first 3 months, and this lasted for 1 year, and antihypertensive drug requirements were significantly decreased continuously up to 9 months(p<0.05). 3) After changing the modality from hemodialysis to peritoneal dialysis, MAP(mmHg, from $107.0{\pm}4.5$ to $98.6{\pm}8.8$, p<0.05), antihypertensive drug requirements(from $5.6{\pm}2.6$, to $2.0{\pm}2.5$, p<0.01) and erythropoietin dosages(Uint/week, from $4600{\pm}2660$ to $2000{\pm}1630$, p<0.05) were decreased. 4) Multiple logistic regression analysis showed that MAP(p<0.01) and daily ultrafiltration volume(p<0.05) can contribute to the determination of antihypertensive drug requirements. However the relationship between antihypertensive drug requirements and PET results or dialysis adequacy indices(weekly Kt/V, weekly creatinine clearance) was not revealed. Conclusion: In conclusion, the prescription of antihypertensive drugs should be considered according to daily ultrafiltration volume, especially during first year after initiating PD, and follow-ups for over a year may be needed.

  • PDF

Optimization and Scale-up of Fish Skin Peptide Loaded Liposome Preparation and Its Storage Stability (어피 펩타이드 리포좀 대량생산 최적 조건 및 저장 안정성)

  • Lee, JungGyu;Lee, YunJung;Bai, JingJing;Kim, Soojin;Cho, Youngjae;Choi, Mi-Jung
    • Food Engineering Progress
    • /
    • v.21 no.4
    • /
    • pp.360-366
    • /
    • 2017
  • Fish skin peptide-loaded liposomes were prepared in 100 mL and 1 L solution as lab scales, and 10 L solution as a prototype scale. The particle size and zeta potential were measured to determine the optimal conditions for the production of fish skin peptide-loaded liposome. The liposome was manufactured by the following conditions: (1) primary homogenization at 4,000 rpm, 8,000 rpm, and 12,000 rpm for 3 minutes; (2) secondary homogenization at 40 watt (W), 60 W, and 80 W for 3 minutes. From this experimental design, the optimal conditions of homogenization were selected as 4,000 rpm and 60 W. For the next step, fish peptides were prepared as the concentrations of 3, 6, and 12% at the optimum manufacturing conditions of liposome and stored at $4^{\circ}C$. Particle size, polydispersion index (pdI), and zeta potential of peptide-loaded liposome were measured for its stability. Particle size increased significantly as manufacture scale and peptide concentration increased, and decreased over storage time. The zeta potential results increased as storage time increased at 10 L scale. In addition, 12% peptide showed the formation of a sediment layer after 3 weeks, and 6% peptide was considered to be the most suitable for industrial application.

Field Test of Optical Voltage and Current Meter (광 응용 전류 전압계의 현장실험)

  • Kim, K.C.;Song, J.T.;Song, W.S.;Kim, C.S.;Lee, K.C.;Lee, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.794-798
    • /
    • 1992
  • We present an optical Voltage and current sensor using $BSO(Bi_{12}SiO_{20})$ monocrystal. The voltage and current sensor consist of PBS(Polarizing Beam Splitter), 1/4 wavelength plate, ZnSe, Selfoc lens, LED, and PIN-PD etc. Magnetic core was made using permalloy for applying magnetic field to current sensor effectively. Current was measured from 100 to 1,600 ampere and accuracy was about ${\pm}$5%. The accuracy could be improved to ${\pm}$l% after reducing the nonlinear property of BSO crystal using our own program in PC (IBM286). We noticed that these data were not influenced by 154,000 voltage at all. Applied voltage was reduced to 1/20 using capacitors. And experiment was carried out up to 450V of the reduced voltage. The data fran optical voltage sensor was similar to that from conventional voltage sensor. The accuracy of the data was within about ${\pm}$1%.

  • PDF

Micropositioning of a Linear Motion Table with Magnetic Bearing Suspension (자기 베어링으로 지지 되는 직선운동 테이블의 초정밀 위치제어에 관한 연구)

  • 김의석;안형준;장인배;한동철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.466-469
    • /
    • 1995
  • This paper presents a design and performance of the 6 D.O.F linear motion table with a magnetic bearing suspension. The linear positioning of the table with a 150mm stroke is driven by a brushless DC Linear motor and the other attitudes of the stage are controlled by the analog PD controller with magnetic bearing actuators. Each magnetic bearing unit which consists of 3 electromagnets, 3 capacitance probes and 3 backup bearings affords controlled forces by detecting the air gap between the probes and guideways. An integral type capacitance probe amplifier is equipped on the upper plate of the table so that the probe line to the probe amplifier can be shorter therefore the problems due to the stray capacitance and noise can be reduced. Form the pitch-yaw errormeasured by the autocollimator, the vertical and horizont straightness errors of the table are derived that they are maintained below 1.mu. m over 100mm stroke. The positioning accuracy of the linear motion is maintained below 2 .mu. m and the repeatability error is below 1 .mu. m

  • PDF

The First-principles View of Nanometal Alloy Catalysts

  • Ham, Hyung Chul;Hwang, Gyeong S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.129-129
    • /
    • 2013
  • Nanometal alloy catalysts have been found to significantly increase catalytic efficiency, compared to the monometallic counterparts. This enhancement can be attributed to various alloying effects: i) the existence of uniquemixed-metal surface sites [the so called ensemble (geometric) effect]; ii) electronic state changes due to metal-metal interactions [the so called ligand (electronic) effect]; and iii) strain caused by lattice mismatch between the alloy components [the socalled strain effect]. In addition, the presence of low-coordination surface atoms and preferential exposure of specific facets [(111), (100), (110)] in association with the size and shape of nanoparticle catalysts [the so called shape-size-facet effect] can be another important factor for modifying the catalytic activity. However, mechanisms underlying the alloying effect still remain unclear owing to the difficulty of direct characterization. Computational approaches, particularly the prediction using first-principles density functional theory (DFT), can be a powerful and flexible alternative for unraveling the role of alloying effects in catalysis since those can give us quantitative insights into the catalytic systems. In this talk, I will present the underlying principles (such as atomic arrangement, facet, local strain, ligand interaction, and effective atomic coordination number at the surface) that govern catalytic reactions occurring on Pd-based alloys using the first-principles calculations. This work highlights the importance of knowing how to properly tailor the surface reactivity of alloy catalysts for achieving high catalytic performance.

  • PDF

Two Cases of Non-Small Cell Lung Cancer Treated with Intravenous Cultivated Wild Ginseng Pharmacopuncture (산삼약침 혈맥주입을 시행한 비소세포성폐암 환자 2례)

  • Bang, Sun-Hwi;Kwon, Ki-Rok;Yoo, Hwa-Seung
    • Journal of Pharmacopuncture
    • /
    • v.11 no.2
    • /
    • pp.13-19
    • /
    • 2008
  • Objectives To investigate the therapeutic effects of intravenous cultivated wild ginseng(Panax ginseng C.A. Meyer) pharmacopuncture(CWGP) in treating patients with non-small cell lung cancer(NSCLC). Design Prospective case series. Setting This study was conducted at the East-West Cancer Center of Dunsan Oriental Hospital, Daejeon University. Patients Two non-small cell lung cancer patients. Intervention Two non-small cell lung cancer patients were injected CWGP(20mL/day) mixed with 0.9% normal saline(100mL) intravenously. Each patient received a total of 16 and 9 cycles, respectively. One cycle is composed of 14 days. Outcome Measures The effect of intravenous CWGP was measured by scanning with computed tomography(CT) after every 2 cycle and Positron emission tomography- computed tomography(PET/CT) after every 6 cycles. Response and progression was evaluated using the Response Evaluation Criteria in Solid Tumors(RECIST) Committee classification of complete response(CR), partial response(PR), progressive disease(PD) and stable disease(SD). Results They were treated with intravenous CWGP for 8 and 5 months respectively. time later, each tumor remains stable disease(SD). Conclusion These cases may give us a possibility that intravenous CWGP offers potential benefits for non-small cell lung cancer patients.

Allele Frequency of the Short Tandem Repeat Locus Human Lipoprotein Lipase(LPL) Gene by Polymerase Chain Reaction in the Korean Population (한국인에서 중합효소연쇄 반응법에 의한 STR 유전좌위 LPL의 유전자빈도 검색)

  • Na, Yun-Ju;Hur, Woong;Yoon, Chang-Lyuk
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.2
    • /
    • pp.253-260
    • /
    • 1997
  • 한국인 집단에서 개인식별의 기초자료로 활용하고자 한국인 201명을 대상으로 STR 유전좌위 중 하나인 LPL 유전좌위의 유전자 빈도 및 유전자형 분포를 구하였다. 혈액으로부터 추출한 핵 DNA를 중합효소연쇄반응으로 증폭시키고 폴리아크릴아마이드 겔 상에서 전기영동하여 은염색한 후 관찰하여 다음의 결과를 얻었다. 1. 한국인 집단 201명의 LPL 유전자에서 5개의 대립유전자, 7개의 유전자형을 검출하였으며, 이형접합도는 50.7%로 나타났고 대립 유전자다양성 (allelic diversity value)은 0.454, 개 인식 별력 (PD)은 0.674를 보였다. 2. 대립 유전자 및 유전자빈도는 9, 10, 11, 12, 13 대립 유전자에서 각각 0.020, 0.714, 0.100, 0.164, 0.002로 나타났으며, 대립유전자 7, 8, 14는 관찰되지 않았다. 이상의 결과를 볼 때 한국인 집단에서 STR LPL유전좌위의 유전자빈도는 친자감정 등 개인식별에 유용하게 사용할 수 있으나 감정실무에 응용시 다수의 STR유전좌위 및 VNTR유전좌위의 분석을 병행하여야 할 것으로 사료된다.

  • PDF