• Title/Summary/Keyword: Patterns

Search Result 28,320, Processing Time 0.062 seconds

Structural and Resting-State Brain Alterations in Trauma-Exposed Firefighters: Preliminary Results (외상에 노출된 소방관들의 뇌 구조 및 휴식기 뇌기능 변화: 예비 결과)

  • Yae Won Park;Suhnyoung Jun;Juwhan Noh;Seok Jong Chung;Sanghoon Han;Phil Hyu Lee;Changsoo Kim;Seung-Koo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.676-687
    • /
    • 2020
  • Purpose To analyze the altered brain regions and intrinsic brain activity patterns in trauma-exposed firefighters without posttraumatic stress disorder (PTSD). Materials and Methods Resting-state functional MRI (rsfMRI) was performed for all subjects. Thirty-one firefighters over 40 years of age without PTSD (31 men; mean age, 49.8 ± 4.7 years) were included. Twenty-six non-traumatized healthy controls (HCs) (26 men; mean age, 65.3 ± 7.84 years) were also included. Voxel-based morphometry was performed to investigate focal differences in the brain anatomy. Seed-based functional connectivity analysis was performed to investigate differences in spontaneous brain characteristics. Results The mean z-scores of the Seoul Verbal Learning Test for immediate and delayed recall, Controlled Oral Word Association Test (COWAT) score for animals, and COWAT phonemic fluency were significantly lower in the firefighter group than in the HCs, indicating decreased neurocognitive function. Compared to HCs, firefighters showed reduced gray matter volume in the left superior parietal gyrus and left inferior temporal gyrus. Further, in contrast to HCs, firefighters showed alterations in rsfMRI values in multiple regions, including the fusiform gyrus and cerebellum. Conclusion Structural and resting-state functional abnormalities in the brain may be useful imaging biomarkers for identifying alterations in trauma-exposed firefighters without PTSD.

Acute Exacerbation of Idiopathic Pulmonary Fibrosis with Lung Cancer: A Comparative Analysis of the Incidence, Survival Rate, and CT Findings with the Patients without Lung Cancer (폐암을 동반한 특발성 폐섬유증 환자에서 폐섬유증의 급성 악화: 폐암 비동반군과의 발병률, 생존율 및 전산화단층촬영 소견의 비교)

  • Bumsang Cho;Hee Kang;Je Hun Kim;Jung Gu Park;Sekyoung Park;Jong Hyouk Yun
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.688-700
    • /
    • 2020
  • Purpose To compare the incidence, survival rate, and CT findings of acute exacerbation (AE) of idiopathic pulmonary fibrosis (IPF) between patients with and without lung cancer. Materials and Methods From June 2004 to July 2018, 89 consecutive patients diagnosed with IPF were included. Among them, 26 patients had IPF with lung cancer (IPF-LCA), and 63 patients had IPF alone. The clinical characteristics and CT findings associated with IPF, lung cancer, and AE were reviewed. Surgery and chemotherapy were performed for 6 and 23 cases of lung cancer, respectively, as the first- or second-line anticancer treatment. The overall survival, CT findings, disease-free period before AE, and duration from the onset of AE to death were compared. Results The incidence of AE was 61.5% in the IPF-LCA group and 58.7% in the IPF group (p = 0.806). The mean overall survival in the IPF-LCA and IPF groups were 16.8 and 83.0 months, respectively (p < 0.001). The mean durations from the start of the lung cancer treatment to the onset of AE were 16.0 and 4.6 months in cases of surgical treatment and chemotherapy, respectively. In comparison of death from AE, the survival rate was significantly lower in the IPF-LCA group than in the IPF group (p = 0.008). In the CT findings associated with AE, the IPF-LCA group tended to have a peribronchial (p < 0.001) or asymmetric distribution (p = 0.016). Conclusion In patients with IPF who develop lung cancer, the rate of death from AE is higher than that in patients with IPF alone. They tend to have unusual CT patterns associated with AE, such as a peribronchial or asymmetric distribution.

Usefulness of 18F-FDG PET/CT and Multiphase CT in the Differential Diagnosis of Hepatocellular Carcinoma and Combined Hepatocellular Carcinoma-Cholangiocarcinoma (간세포암종과 혼합성 간세포암종-담관암종에서 다위상 전산단층촬영술 소견과 18F-FDG PET/CT에서 섭취율 차이에 대한 분석 )

  • Jae Chun Park; Jung Gu Park;Gyoo-Sik Jung;Hee Kang;Sungmin Jun
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1424-1435
    • /
    • 2020
  • Purpose The purpose of this study was to evaluate the usefulness of multiphasic CT and 18F-fluorodeoxyglucose (FDG) PET/CT for the differentiation of combined hepatocellular carcinoma-cholangiocarcinoma (cHCC-CCA) from hepatocellular carcinoma (HCC). Materials and Methods From January 2007 to April 2016, 93 patients with pathologically confirmed HCC (n = 84) or cHCC-CCA (n = 9) underwent CT and PET/CT imaging. Contrast enhancement patterns were divided into three types based on the attenuation of the surrounding liver parenchyma: type I (early arterial enhancement with delayed washout), type II (early arterial enhancement without delayed washout), and type III (early hypovascular, infiltrative appearance, or peripheral rim enhancement). Results cHCC-CCAs (89%) had a higher PET/CT positive rate than did HCCs (61%), but the PET/CT positive rate did not differ significantly (p = 0.095). Among the 19 cases of the type II enhancement pattern, 3 (21%) of 14 HCCs and 4 (80%) of 5 cHCC-CCAs were PET/CT positive. cHCC-CCAs had a significantly higher PET/CT positive rate (p = 0.020) in the type II enhancement pattern. Conclusion The PET/CT positive rate of cHCC-CCA was significantly higher than that of HCC in lesions with a type II enhancement pattern. The 18F-FDG PET/CT can be useful for the differentiation of cHCC-CCA from HCC in lesions with a type II enhancement pattern on multiphasic CT.

Generative Adversarial Network-Based Image Conversion Among Different Computed Tomography Protocols and Vendors: Effects on Accuracy and Variability in Quantifying Regional Disease Patterns of Interstitial Lung Disease

  • Hye Jeon Hwang;Hyunjong Kim;Joon Beom Seo;Jong Chul Ye;Gyutaek Oh;Sang Min Lee;Ryoungwoo Jang;Jihye Yun;Namkug Kim;Hee Jun Park;Ho Yun Lee;Soon Ho Yoon;Kyung Eun Shin;Jae Wook Lee;Woocheol Kwon;Joo Sung Sun;Seulgi You;Myung Hee Chung;Bo Mi Gil;Jae-Kwang Lim;Youkyung Lee;Su Jin Hong;Yo Won Choi
    • Korean Journal of Radiology
    • /
    • v.24 no.8
    • /
    • pp.807-820
    • /
    • 2023
  • Objective: To assess whether computed tomography (CT) conversion across different scan parameters and manufacturers using a routable generative adversarial network (RouteGAN) can improve the accuracy and variability in quantifying interstitial lung disease (ILD) using a deep learning-based automated software. Materials and Methods: This study included patients with ILD who underwent thin-section CT. Unmatched CT images obtained using scanners from four manufacturers (vendors A-D), standard- or low-radiation doses, and sharp or medium kernels were classified into groups 1-7 according to acquisition conditions. CT images in groups 2-7 were converted into the target CT style (Group 1: vendor A, standard dose, and sharp kernel) using a RouteGAN. ILD was quantified on original and converted CT images using a deep learning-based software (Aview, Coreline Soft). The accuracy of quantification was analyzed using the dice similarity coefficient (DSC) and pixel-wise overlap accuracy metrics against manual quantification by a radiologist. Five radiologists evaluated quantification accuracy using a 10-point visual scoring system. Results: Three hundred and fifty CT slices from 150 patients (mean age: 67.6 ± 10.7 years; 56 females) were included. The overlap accuracies for quantifying total abnormalities in groups 2-7 improved after CT conversion (original vs. converted: 0.63 vs. 0.68 for DSC, 0.66 vs. 0.70 for pixel-wise recall, and 0.68 vs. 0.73 for pixel-wise precision; P < 0.002 for all). The DSCs of fibrosis score, honeycombing, and reticulation significantly increased after CT conversion (0.32 vs. 0.64, 0.19 vs. 0.47, and 0.23 vs. 0.54, P < 0.002 for all), whereas those of ground-glass opacity, consolidation, and emphysema did not change significantly or decreased slightly. The radiologists' scores were significantly higher (P < 0.001) and less variable on converted CT. Conclusion: CT conversion using a RouteGAN can improve the accuracy and variability of CT images obtained using different scan parameters and manufacturers in deep learning-based quantification of ILD.

New Trends in the Production of One Hundred Fans Paintings in the Late Joseon Period: The One Hundred Fans Painting in the Museum am Rothenbaum Kulturen und Künste der Welt in Germany and Its Original Drawings at the National Museum of Korea (조선말기 백선도(百扇圖)의 새로운 제작경향 - 독일 로텐바움세계문화예술박물관 소장 <백선도(百扇圖)>와 국립중앙박물관 소장 <백선도(百扇圖) 초본(草本)>을 중심으로 -)

  • Kwon, Hyeeun
    • MISULJARYO - National Museum of Korea Art Journal
    • /
    • v.96
    • /
    • pp.239-260
    • /
    • 2019
  • This paper examines the circulation and dissemination of painting during and after the nineteenth century through a case study on the One Hundred Fans paintings produced as decorative folding screens at the time. One Hundred Fans paintings refer to depictions of layers of fans in various shapes on which pictures of diverse themes are drawn. Fans and paintings on fans were depicted on paintings before the nineteenth century. However, it was in the nineteenth century that they began to be applied as subject matter for decorative paintings. Reflecting the trend of enjoying extravagant hobbies, fans and paintings on fans were mainly produced as folding screens. The folding screen of One Hundred Fans from the collection of the Museum am Rothenbaum Kulturen und Künste der Welt (hereafter Rothenbaum Museum) in Germany was first introduced to Korean in the exhibition The City in Art, Art in the City held at the National Museum of Korea in 2016. Each panel in this six-panel folding screen features more than five different fans painted with diverse topics. This folding screen is of particular significance since the National Museum of Korea holds the original drawings. In the nineteenth century, calligraphy and painting that had formerly been enjoyed by Joseon royal family members and the nobility in private spaces began to spread among common people and was distributed through markets. In accordance with the trend of adorning households, colorful decorative paintings were preferred, leading to the popularization of the production of One Hundred Fans folding screens with pictures in different shapes and themes. A majority of the Korean collection in the Rothenbaum Museum belonged to Heinrich Constantin Eduard Meyer(1841~1926), a German businessman who served as the Joseon consul general in Germany. From the late 1890s until 1905, Meyer traveled back and forth between Joseon and Germany and collected a wide range of Korean artifacts. After returning to Germany, he sequentially donated his collections, including One Hundred Fans, to the Rothenbaum Museum. Folding screens like One Hundred Fans with their fresh and decorative beauty may have attracted the attention of foreigners living in Joseon. The One Hundred Fans at the Rothenbaum Museum is an intriguing work in that during its treatment, a piece of paper with the inscription of the place name "Donghyeon" was found pasted upside down on the back of the second panel. Donghyeon was situated in between Euljiro 1-ga and Euljiro 2-ga in present-day Seoul. During the Joseon Dynasty, a domestic handicraft industry boomed in the area based on licensed shops and government offices, including the Dohwaseo (Royal Bureau of Painting), Hyeminseo (Royal Bureau of Public Dispensary), and Jangagwon (Royal Bureau of Music). In fact, in the early 1900s, shops selling calligraphy and painting existed in Donghyeon. Thus, it is very likely that the shops where Meyer purchased his collection of calligraphy and painting were located in Donghyeon. The six-panel folding screen One Hundred Fans in the collection of the Rothenbaum Museum is thought to have acquired its present form during a process of restoring Korean artifacts works in the 1980s. The original drawings of One Hundred Fans currently housed in the National Museum of Korea was acquired by the National Folk Museum of Korea between 1945 and 1950. Among the seven drawings of the painting, six indicate the order of their panels in the margins, which relates that the painting was originally an eight-panel folding screen. Each drawing shows more than five different fans. The details of these fans, including small decorations and patterns on the ribs, are realistically depicted. The names of the colors to be applied, including 'red ocher', 'red', 'ink', and 'blue', are written on most of the fans, while some are left empty or 'oil' is indicated on them. Ten fans have sketches of flowers, plants, and insects or historical figures. A comparison between these drawings and the folding screen of One Hundred Fans at the Rothenbaum Museum has revealed that their size and proportion are identical. This shows that the Rothenbaum Museum painting follows the directions set forth in the original drawings. The fans on the folding screen of One Hundred Fans at the Rothenbaum Museum are painted with images on diverse themes, including landscapes, narrative figures, birds and flowers, birds and animals, plants and insects, and fish and crabs. In particular, flowers and butterflies and fish and crabs were popular themes favored by nineteenth century Joseon painters. It is noteworthy that the folding screen One Hundred Fans at the Rothenbaum Museum includes several scenes recalling the typical painting style of Kim Hong-do, unlike other folding screens of One Hundred Fans or Various Paintings and Calligraphy. As a case in point, the theme of "Elegant Gathering in the Western Garden" is depicted in the Rothenbaum folding screen even though it is not commonly included in folding screens of One Hundred Fans or One Hundred Paintings due to spatial limitations. The scene of "Elegant Gathering in the Western Garden" in the Rothenbaum folding screen bears a resemblance to Kim Hong-do's folding screen of Elegant Gathering in the Western Garden at the National Museum of Korea in terms of its composition and style. Moreover, a few scenes on the Rothenbaum folding screen are similar to examples in the Painting Album of Byeongjin Year produced by Kim Hong-do in 1796. The painter who drew the fan paintings on the Rothenbaum folding screen is presumed to have been influenced by Kim Hong-do since the fan paintings of a landscape similar to Sainsam Rock, an Elegant Gathering in the Western Garden, and a Pair of Pheasants are all reminiscent of Kim's style. These paintings in the style of Kim Hong-do are reproduced on the fans left empty in the original drawings. The figure who produced both the original drawings and fan paintings appears to have been a professional painter influenced by Kim Hong-do. He might have appreciated Kim's Painting Album of Byeongjin Year or created duplicates of Painting Album of Byeongjin Year for circulation in the art market. We have so far identified about ten folding screens remaining with the One Hundred Fans. The composition of these folding screens are similar each other except for a slight difference in the number and proportion of the fans or reversed left and right sides of the fans. Such uniform composition can be also found in the paintings of scholar's accoutrements in the nineteenth century. This suggests that the increasing demand for calligraphy and painting in the nineteenth century led to the application of manuals for the mass production of decorative paintings. As the demand for colorful decorative folding screens with intricate designs increased from the nineteenth century, original drawings began to be used as models for producing various paintings. These were fully utilized when making large-scale folding screens with images such as Guo Ziyi's Enjoyment-of-Life Banquet, Banquet of the Queen Mother of the West, One Hundred Children, and the Sun, Cranes and Heavenly Peaches, all of which entailed complicated patterns. In fact, several designs repeatedly emerge in the extant folding screens, suggesting the use of original drawings as models. A tendency toward using original drawings as models for producing folding screens in large quantities in accordance with market demand is reflected in the production of the folding screens of One Hundred Fans filled with fans in different shapes and fan paintings on diverse themes. In the case of the folding screens of One Hundred Paintings, bordering frames are drawn first and then various paintings are executed inside the frames. In folding screens of One Hundred Fans, however, fans in diverse forms were drawn first. Accordingly, it must have been difficult to produce them in bulk. Existing examples are relatively fewer than other folding screens. As discussed above, the folding screen of One Hundred Fans at the Rothenbaum Museum and its original drawings at the National Museum of Korea aptly demonstrate the late Joseon painting trend of embracing and employing new painting styles. Further in-depth research into the Rothenbaum painting is required in that it is a rare example exhibiting the influence of Kim Hong-do compared to other paintings on the theme of One Hundred Fans whose composition and painting style are more similar to those found in the work of Bak Gi-jun.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

A Study on the Location of Retail Trade in Kwangju-si and Its Inhabitants와 Effcient Utilization (광주시 소매업의 입지와 주민의 효율적 이용에 관한 연구)

  • ;Jeon, Kyung-sook
    • Journal of the Korean Geographical Society
    • /
    • v.30 no.1
    • /
    • pp.68-92
    • /
    • 1995
  • Recentry the structure of the retail trade have been chanaed with its environmantal changes. Some studies may be necessary on the changing process of environment and fundamental structure analyses of the retail trade. This study analyzes the location of retail trades, inhabitants' behavior in retail tredes and their desirable utilization scheme of them in Kwangju-si. Some study methods, contents and coming-out results are as follows: 1. Retail trades can be classified into independent stores, chain-stores (supermarket, voluntary chain and frenchiise system and convenience store), department stores, cooperative associations, traditional, markets mail-order marketing, automatic vending and others by service levels, selling-items, prices, managements, methods of retailing and store or nonstore type. 2. In Kwangju, the environment of retail trades is related to the consumers of population structure: chanes in consumers pattern, trends toward agings and nuclear family, increase of leisur: time and female advances to society. Rapid structural shift in retail trade has also been occurred due to these social changes. Traditionl and premodern markets until 1970s altere to supermarkets or department stores in 1980s, and various types, large enterprises and foreign capitals came into being in 1990s. 3. The locational characteristics of retail trades are resulted from the spatial analysis of the total population distribution, and from the calculation of segregation index in the light of potential demand. The densely-populated areas occurs in newly-built apartment housing complex which is distributed with a ring-shaped pattern around the old urban core. The numbers and rates of the aged over sixty in Kwangsan-gu and the circumference area of Mt.Moodeung, are larger and higher where rural elements are remarkable. A relation between population distribution and retail trade are analysed by the index of population per shop. The index of the population number per shop is lower in urban center, as a whole, being more convenient for consumers. In newly-formed apartment complex areas, on the other, the index more than 1,000 per shop, meeting not the demands for consumers. Because both the younger and the aged are numerous in these areas, the retail trade pattern pertinent to both are needed. Urban fringes including Kwangsan-gu and the vicinity of Mt.Moodeung have some problems owing to the most of population number per shop (more than 1, 500) and the most extensive as well. 4. The regional characteristic of retail trade is analyzed through the location quotient of shops by locational patterns and centerality index. Chungkum-dong is the highest-order central place in CBD. It is the core of retail trades, which has higher-ordered specialty store including three big department stores, supermarkets and large stores. Taegum-dong, Chungsu-dong, Taeui-dong, and Numun-dong that are neiahbored to Chungkum-dong fall on the second group. They have a central commercial section where large chain stores, specialty shopping streets, narrow-line retailing shops (furniture, amusement service, and gallary), supermarkets and daily markets are located. The third group is formed on the axis of state roads linking to Naju-kun, Changseong-kun, Tamyang-kun, Hwasun-kun and forme-Songjeong-eup. It is related to newly, rising apartment housing complex along a trunk road, and characterized by markets and specialty stores. The fourth group has neibourhood-shopping centers including older residential area and Songjeong-eup area with independent stores and supermarkets as main retailing functions. The last group contains inner residential area and outer part of a city including Songjeong-eup. Outer part of miscellaneous shops being occasionally found is rural rather than urban (Fig. 7). 5. The residents' behaviors using retail trade are analyzed by factors of goods and facilities. Department stores are very high level in preference for higher-order shopping-goods such as clothes for full dress in view of both diversity and quality of goods(28.9%). But they have severe traffic congestions, and high competitions for market ranges caused by their sma . 64.0% of respondents make combined purpose trips together with banking and shopping. 6. For more efficiency of retail-trading, it is necessary to induce spatial distribution policy with regard to opportunity frequency of goods selection by central place, frontier regions and age groups. Also we must consider to analyze competition among different types of retail trade and analyze the consumption behaviors of working females and younger-aged groups, in aspects of time and space. Service improvement and the rationalization of management should be accomplished in such as cooperative location (situation) must be under consideration in relations to other functions such as finance, leisure & sports, and culture centers. Various service systems such as installment, credit card and peremium ticket, new used by enterprises, must also be carried service improvement. The rationalization and professionalization in for the commercial goods are bsically requested.

  • PDF

Problems in the field of maternal and child health care and its improvement in rural Korea (우리나라 농촌(農村)의 모자보건(母子保健)의 문제점(問題點)과 개선방안(改善方案))

  • Lee, Sung-Kwan
    • Journal of agricultural medicine and community health
    • /
    • v.1 no.1
    • /
    • pp.29-36
    • /
    • 1976
  • Introduction Recently, changes in the patterns and concepts of maternity care, in both developing and developed countries have been accelerating. An outstanding development in this field is the number of deliveries taking place in hospitals or maternity centers. In Korea, however, more than 90% of deliveries are carried out at home with the help of untrained relatives or even without helpers. It is estimated that less than 10% of deliveries are assisted by professional persons such as a physician or a midwife. Taking into account the shortage of professional person i11 rural Korea, it is difficult to expect widespread prenatal, postnatal, and delivery care by professional persons in the near future, It is unrealistic, therefore, to expect rapid development of MCH care by professional persons in rural Korea due to economic and sociological reasons. Given these conditions. it is reasonable that an educated village women could used as a "maternity aid", serving simple and technically easy roles in the MCH field, if we could give such a women incentive to do so. The midwife and physician are assigned difficult problems in the MCH field which could not be solved by the village worker. However, with the application of the village worker system, we could expect to improve maternal and child hoalth through the replacement of untrained relatives as birth attendants with educated and trained maternity aides. We hope that this system will be a way of improving MCH care, which is only one part of the general health services offered at the local health centre level. Problems of MCH in rural Korea The field of MCH is not only the weakest point in the medical field in our country hut it has also dropped behind other developing countries. Regarding the knowledge about pregnancy and delivery, a large proportion of our respondents reported having only a little knowledge, while 29% reported that they had "sufficient" knowledge. The average number of pregnancies among women residing in rural areas was 4.3 while the rate of women with 5 or more pregnancies among general women and women who terminated childbearing were 43 and 80% respectively. The rate of unwanted pregnancy among general women was 19.7%. The total rate for complications during pregnancy was 15.4%, toxemia being the major complication. The rate of pregnant women with chronic disease was 7%. Regarding the interval of pregnancy, the rates of pregnancy within 12 months and within 36 months after last delivery were 9 and 49% respectively. Induced abortion has been increasing in rural areas, being as high as 30-50% in some locations. The maternal death rate was shown 10 times higher than in developed countries (35/10,000 live births). Prenatal care Most women had no consultation with a physician during the prenatal period. Of those women who did have prenatal care, the majority (63%) received such care only 1 or 2 times throughout the entire period of pregnancy. Also, in 80% of these women the first visit Game after 4 months of gestation. Delivery conditions This field is lagging behind other public health problems in our country. Namely, more than 95% of the women deliveried their baby at home, and delivery attendance by a professional person occurred only 11% of the time. Attendance rate by laymen was 78% while those receiving no care at all was 16%. For instruments used to cut the umbilical corn, sterilized scissors were used by 19%, non-sterilized scissors by 63% and 16% used sickles. Regarding delivery sheets, the rate of use of clean sheets was only 10%, unclean sheets, vinyl and papers 72%, and without sheets, 18%. The main reason for not using a hospital as a place of delivery was that the women felt they did not need it as they had previously experience easy deliveries outside hospitals. Difficult delivery composed about 5% of the total. Child health The main food for infants (95%) was breast milk. Regarding weaning time, the rates within one year, up to one and half, two, three and more than three years were 28,43,60,81 and 91% respectively, and even after the next pregnancy still continued lactation. The vaccination of children is the only service for child health in rural Korea. As shown in the Table, the rates of all kinds of vaccination were very low and insufficient. Infant death rate was 42 per 1,000 live births. Most of the deaths were caused by preventable diseases. Death of infants within the neonatal period was 83% meaning that deaths from communicable diseases decreased remarkably after that time. Infant deaths which occurred without medical care was 52%. Methods of improvement in the MCH field 1. Through the activities of village health workers (VHW) to detect pregnant women by home visiting and. after registration. visiting once a month to observe any abnormalities in pregnant women. If they find warning signs of abnormalities. they refer them to the public health nurse or midwife. Sterilized delivery kits were distributed to the expected mother 2 weeks prior to expected date of delivery by the VHW. If a delivery was expected to be difficult, then the VHW took the mother to a physician or call a physician to help after birth, the VHW visits the mother and baby to confirm health and to recommend the baby be given proper vaccination. 2. Through the midwife or public health nurse (aid nurse) Examination of pregnant women who are referred by the VHW to confirm abnormalities and to treat them. If the midwife or aid nurse could not solve the problems, they refer the pregnant women to the OB-GY specialist. The midwife and PHN will attend in the cases of normal deliveries and they help in the birth. The PHN will conduct vaccination for all infants and children under 5, years old. 3. The Physician will help only in those cases referred to him by the PHN or VHW. However, the physician should examine all pregnant women at least three times during their pregnancy. First, the physician will identify the pregnancy and conduct general physical examination to confirm any chronic disease that might disturb the continuity of the pregnancy. Second, if the pregnant woman shows any abnormalities the physician must examine and treat. Third, at 9 or 10 months of gestation (after sitting of the baby) the physician should examine the position of the fetus and measure the pelvis to recommend institutional delivery of those who are expected to have a difficult delivery. And of course. the medical care of both the mother and the infants are responsible of the physician. Overall, large areas of the field of MCH would be served by the VHW, PHN, or midwife so the physician is needed only as a parttime worker.

  • PDF

The Cross-Cultural Study about Effects of Service Quality Dimensions on CS in Korea and China (할인점 서비스품질의 각 차원이 CS에 미치는 영향에 대한 한(韓).중(中)간 비교 문화적 연구)

  • Noh, Eun-Jeong;Seo, Yong-Goo
    • Journal of Global Scholars of Marketing Science
    • /
    • v.19 no.1
    • /
    • pp.23-35
    • /
    • 2009
  • A hypermarket as the one of the most globally standardized retailing format is also the type of store among various types of stores that the most active in expanding into other foreign markets. Recently, as several Korean retailing companies start to penetrate into Chinese market they differentiate themselves with modern facilities and customers service oriented high-end concept. China and Korea as Far East Asian countries share many common values, however precise and careful analysis should be carried out since there may also be critical differences in socio-economic aspects as well as in consumption patterns due to the level of development stages of retail industry among two countries. Even though precise and careful study is crucial on Chinese retailing market and consumers, none of researches and studies on 'how the quality of service dimensional structure is different between Korea and China', and 'what will be the most important and influential service dimensional factors for Chinese consuers compared to the hypermarkets customers in Korea' in order to improve the level of Chinese consumers satisfaction' have been fulfilled At this point of view, this study uses KD-SQS (Rho Eun Jung & Sir Yong Gu, 2008) which is a measure of Korean hypermarkets service quality to set up a hypothesis on Korean and Chinese consumers, and an empirical analysis is conducted. We try to get the answers about how the comparative importance of Service quality dimensions which decides the level of customer satisfaction is different depending on the cultural dimensions and socio-economic factors among two countries, Korea and China. Based upon the results, we try to give a valuable suggestion of what service dimensional factors should be reinforced to improve the level of CS in Chinese retailing market. Hypotheses for this study are as follows : H1. Each dimension of Service Quality significantly affects the level of CS H2. The effect of 'Basic Benefit' in service quality dimensions on the level of CS is greater in China than in Korea H3. The effect of 'Promotion' in service quality dimensions on the level of CS is greater in China than in Korea H4. The effect of 'Physical Aspects'in service quality dimensions on the level of CS is greater in Korea than in China. H5. The effect of 'Personal Interaction' in service quality dimensions on the level of CS is greater in China than in Korea H6. The effect of 'Policy' in service quality dimensions on the level of CS will be greater in Korean than in China H7. The effect of additional convenience in service quality dimensions on the level of CS will be greater in Korean than in China. More than 1,100 data were collected directly from the surveys of Chinese and Korean consumers in order to verify the hypotheses above. In Korea, stores which have floor space of over $9,000m^2$and opened later than year 2000 were selected for the samples, and thus Gayang, Wolgye, Sangbong, Eunpyeong, Suh-Suwon, Gojan stores and their customers were surveyed. In China, notable differences in the income levels and consumer behaviors between cities and regions were considered, and thus the research area was limited to the stores only in Shanghai. 6 stores which have the size of over $6,000m^2$ and opened later than 2000, such as Ruihong, Intu, Mudanjang, Sanrin, Raosimon, and Ranchao stores were selected for the survey. SPSS 12.0 and AMOS 7.0 were used as statistical tools, and exploratory factor analysis, confirmatory factor analysis, and multi-group analysis were conducted. In order to carry out a multi group analysis that decides whether the structure variables which shows the different effects of 6 service dimensions in Korean and Chinese groups is statistically valid, configural invariance, metric invariance, and structural invariance are tested in order. At the results of the tests, 3 out of 7 hypotheses were supported and other 4 hypotheses were denied. According to the study, 4 dimensions (Basic Benefit, Physical Environment, Policy, and additional convenience) were positively correlated with CS in Korea, and 3 dimensions (i.e. basic benefit, policy, additional convenience) were significant in China. However, the significance of the service-dimensions was turned out to be partially different in Korea and China. The Basic Benefit is more influential in deciding the level of CS in china than Korea, however Physical Aspect is more important factor in Korea. 'Policy dimension' did not make significant difference between two countries. In the 'additional convenience dimension', the differences in 'socio-economic factors' than in'cultural background' were considered as more important in Chinese consumers than Korean. Overall, the improvement of Service quality will be crucial factors to increase the level of CS in Chinese market same as Korean market. In addition, more emphases need to be placed on the service qualities of 'Basic Benefit' and 'additional convenience' dimensions in China. In particular, 'low price' and 'product diversity' that constitute 'Basic Benefit' are proved to be comparatively disadvantageous and weak points of Korean companies compared to global players, and thus the prompt strengthening those dimensions would be urgent for Korean retailers. Moreover, additional conveniences such as various tenants and complex service and entertaining area will be more important in China than in Korea. Besides, Applying advanced Korean Hypermaret`s customer policy to Chinese consumers will help to get higher reliability and to differentiate themselves to other competitors. However, as personal interaction, physical aspect, promotions were proved as not significant for the level of CS in China, Korean companies need to reconsider the priority order of resource allocations when they tap into Chinese market.

  • PDF