• Title/Summary/Keyword: Pattern measurement

Search Result 1,883, Processing Time 0.032 seconds

Design of Brassiere Pattern for Big Size Breast Women -Based on 3D Breast Scanning Data- (유방이 큰 여성을 위한 브래지어 패턴 설계 -3차원 유방 형상 자료를 중심으로-)

  • Han, Chohee;Yi, Kyong-Hwa
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.43 no.2
    • /
    • pp.204-214
    • /
    • 2019
  • A CAD program has recently been introduced that can be directly developed into a three-dimensional human body shape and made into a pattern. It is possible to fabricate a bra that reflects the volume and surface area of the breast; however, it still needs to be verified. This study investigates the average size and shape of 20 big-breasted women and designs a brassiere pattern for women with large breasts using a 3D Flattening function of OptiTex PDS v15.6. In addition, the study verifies the reliability of the proposed method compared to a conventional brassiere pattern. The study results are as follows. First, the three dimensional measurement values were smaller than the direct measurement dimensions when the three dimension measurement dimensions of the subjects were compared with the direct measurement dimensions, the replica measurement dimensions and the three dimensional measurement dimensions. Second, the 3D flattening pattern reflects the actual shape, length, and area of the actual breast when comparing a brassiere pattern using a 3D shape and pattern reflecting the direct measurement.

Study on the Basic Bodice Pattern Grading according to the Measurement Variations of the Body (인체 부위별 치수증감을 반영한 길 원형 그레이딩에 관한 연구)

  • Jung, Myoung-Sook
    • The Korean Journal of Community Living Science
    • /
    • v.20 no.4
    • /
    • pp.571-578
    • /
    • 2009
  • This study was to apply the measurement variations of each region of the body to the basic bodice pattern grading and to provide the clothing pattern fit for the human body. Grading variation used in the apparel industry was researched and new grading variation was proposed by analyzing the statistical data of body measurements. The statistical variation in body measurements was applied to set the optimum grading region and variation. Five sizes were used by split grading method and drawn with Bust Circumference and waist length based on the middle size. Differences between the grading pattern and the drawing pattern were analyzed by overlapping them and measuring each region. The measurement variations of drawing patterns between the sizes were very different from those of statistical data. On the other hand, the measurement variations of grading patterns between the sizes and those of statistical data were similar. In summary, the grading pattern by applying the measurement variations to the region of the body was superior to the drawing pattern drawn by the basic measurements for clothing fitness.

  • PDF

A study on the Korean trousers pattern design (남자한복(男子韓服)의 바지원형제도에 관한 연구)

  • Lee, Soon-Ja
    • Journal of the Korean Society of Costume
    • /
    • v.15
    • /
    • pp.21-45
    • /
    • 1990
  • The purpose of this thesis is to study the method of the reasonable pattern design. The studying method is based on the original principle of the trousers' cutting and I have a hypothesis about the trousers pattern which should be proved. When I selected the practical method, I made use of the international measuring rule, graph paper and tracing paper, in order to prove the new pattern design. The reasonable pattern design should be the one of the suitable original principles to be suited in the design through any measurement. Therefore, I have discussed the above mentioned design. I find out the conclusion to prove the hypothesis of pattern design with the experimental measure after showing the above mentiond design. The characteristics is as follows. First : To be convinient when walking, because of little degree as folding of the front part of trousers with the under-angle. Second : To be suitable in proportion to the length of trousers and the under-angle. Third ; When folding the center line of the Sapok (a name of one of the trousers parts), the length of the Sapoks is same and harmonized with the Sapoks because of the same angle of both Sapoks in any case of the measurement. Fourth : No correction of the lines when dressing, for the same points of the large Sapok and the small one. Fifth : To be easiness of the pattern design through the concrete measurement. I could find out a little extent errors of pattern showings, an easiness of dressing, scientification of formation in Korean trousers and standard of the practical measurement in the program to be presented as the result of studying.

  • PDF

A Study on the Measurement of the Beam Pattern of Array Antenna for VHF Radar using Active Beam Pattern Measuring Device and Drone (능동 빔패턴 측정장치 및 드론을 활용한 초단파레이다용 배열안테나의 빔패턴 측정에 대한 연구)

  • Kim, Ki-Jung;Lee, Sung-Je;Jang, Youn-Hui
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1031-1036
    • /
    • 2019
  • This study describes the technique of the beam pattern measurement of array antenna for VHF band radar using drone and active beam pattern measuring device. There is no anechoic chamber for measuring the beam pattern of a large size antenna in the country. In this study, to test the antenna beam pattern characteristics of the developed VHF band radar, the antenna beam pattern characteristics were tested by Drone mounting an Active Beam Pattern Measuring Device. By comparing the results of the pre-simulation analysis with the measured results for the antenna, we could confirm that the beamwidth and side-lobe characteristics are satisfactory. Through the antenna beam pattern measurement technology using Drone and Active Beam Pattern Measuring Device, the beam pattern measurement technology of array antenna of low frequency band and large antenna for low band radar will be used.

Calculation of Composite Desirability Function According to the Measurement Unit and Numerical Pattern of Characteristics in the Multiple Response Analysis (MRA에서 특성값의 측정단위와 수치형태에 따른 종합 만족도 산출 방법)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.11a
    • /
    • pp.565-572
    • /
    • 2009
  • This paper presents the optimization steps with weight and importance of estimated characteristic values in the multiresponse surface analysis(MRA). The research introduces the shape parameter of individual desirability function for relaxation and tighening of specification bounds. The study also proposes the combinded desirability function using arithmetic, geometric and harmonic means considering the measurement unit and numerical pattern.

  • PDF

An Experimental Technique with Pattern Recognition for Deformation Measurement of Small Structures (패턴 인식을 통한 미소 구조물의 변형 측정 기법 개발)

  • 박태상;백동천;이순복
    • Transactions of Materials Processing
    • /
    • v.11 no.7
    • /
    • pp.614-619
    • /
    • 2002
  • For an accurate measurement of the material behavior of small structures, a new optical experimental technique is proposed to measure the deformation. The test method uses the dual microscope that can measure the relative deformation of two adjacent regions. The magnified view is captured by CCD cameras and the relative deformation can be measured by the pattern matching and tracing method. Using this experimental technique, the deformation of solder joints in electronic packaging and the strain of the nickel thin film are measured.

Improvement of ECG Measurement for the Elderly's U-healthcare Clothing Using 3D Tight-fit Pattern (3D패턴을 이용한 노인용 u-헬스케어 의복의 심전도 측정 연구)

  • Park, Hye-Jun;Shin, Seung-Chul;Shon, Boo-Hyun;Hong, Kyung-Hi
    • Fashion & Textile Research Journal
    • /
    • v.10 no.5
    • /
    • pp.676-682
    • /
    • 2008
  • In this study a guideline of the 3D-fit pattern for the ECG(electrocardiogram) measurement of elderly's u-healthcare clothes was proposed. In the screening test of the ECG measurement band, ECG peak band was observable at the band pressure of 0.20 kPa. By employing a 3D body image, tight-fit 3D patterns were made at two different reduction rates of 21%(pattern 1) and 33%(pattern 2), and corresponding pressure of both of the clothes were 0.25 kPa and 0.54 kPa, respectively. Typical waves of ECG were found in both stationary and moving position. In terms of the subjective evaluation of the u-healthcare clothes when worn, it was confirmed that reduction pattern 1(0.25 kPa) conveyed comfortable clothing pressure and pleasantness, which is very close to the result of screening test of ECG band experiment. As results, it is recommended that reduction rate should be adjusted, so that clothing pressure is about 0.2 kPa for the elderly's comfortable and efficient u-healthcare clothes.

A Method for Projecting Multiple Stripe Patterns for High Precision 3D Measurement (고정밀 3차원 측정을 위한 다중 줄무늬 투영 방법에 관한 연구)

  • Chang, Min-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.2 s.191
    • /
    • pp.58-63
    • /
    • 2007
  • This paper proposes a novel method of projecting a multiple stripe pattern whose intensity profile is sinusoidal. The sinusoidal stripe patterns are plated with chromium on a piece of glass, and the glass is placed within an optical projection system. By linearly moving the glass along the direction of the stripe pattern, the projection system generates the motion blurring effect, and as a result, produces a blurred stripe pattern whose intensity profile is sinusoidal along the perpendicular direction of the stripe pattern. The sinusoidal pattern improves the measurement accuracy of phase-shifting method. Experimental results are provided for three different types of stripe patterns: rectangle, diamond, and sinusoid.

The Merging Method of Point Data with Point Pattern Matching in 3D Measurement (3차원 형상측정에서 점 패턴매칭을 이용한 점 데이터의 결합방법)

  • 조택동;이호영;양상민
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.9
    • /
    • pp.714-719
    • /
    • 2003
  • We propose a measuring method of large object using the pattern matching. It is hard and expensive to get the complete 3D data when the object is large and exceeds the limit of measuring devices. The large object is divided into several smaller areas and is scanned several times to get the data of all the pieces. These data are aligned to get the complete 3D data using the pattern matching method such as point pattern matching method and transform matrix algorithm. The laser slit beam and CCD camera are applied for the experimental measurement. Visual C++ on Windows 98 is implemented in processing the algorithm.

PCB Integrated Spiral Pattern Pick-up Coil Current Measurement Scheme with High Sensitivity for WBG Devices (WBG 소자를 위한 높은 측정 감도를 가지는 PCB 내장형 Spiral 패턴 Pick-up Coil 전류 측정 기법)

  • Kim, Kyeong-Mo;Cha, Hwa-Rang;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.3
    • /
    • pp.162-170
    • /
    • 2020
  • In this paper, we report our study of the current measuring technique by implementing a pick-up coil in the PCB pattern instead of the current measuring sensor in a power converter using a WBG device. The proposed PCB pattern coil structure has a higher mutual inductance value than the conventional pattern by constructing the coil using the multi layer board. It has high sensitivity and is configured without additional process outside the PCB. In the current measurement, the integrator is measured by integrating the coil at the back end and the current waveform measured using proposed pick-up coil is confirmed by comparing it with the original current waveform through DPT simulation.