• Title/Summary/Keyword: Patients with cancer

Search Result 9,669, Processing Time 0.044 seconds

In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma (직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Lee, Hwang Kyu;Jee, Keum Nahn;Hong, Sujin;Koh, Jae Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Purpose : To evaluate and compare the accuracy of magnetic resonance imaging (MRI) and ultrasound (US) for detection and estimation of invasion depth of colorectal carcinoma (CRC) by correlation with histopathologic findings in vitro, and to find out the best MR pulse sequence for accurate delineation of tumor from surrounding normal tissue. Materials and Methods: Resected specimens of CRC from 45 patients were examined about tumor detectability and invasion depth of US using high frequency (5-17 MHz) linear transducer in a tube filled with normal saline and MRI in a 8-channel quadrate head coil. The institutional review board approved this study and informed consent was waived. MRI with seven pulse sequences of in- and out-of-phases gradient echo T1 weighted images, fast spin echo T2 weighted image and its fat suppression image, fast imaging employing steady-state acquisition (FIESTA) and its fat suppression image, and diffusion weighted image (DWI) were performed. In each case, both imaging findings of MRI and US were evaluated independently for detection and estimation of invasion depth of tumor by consensus of two radiologists and were compared about diagnostic accuracy according to the histopathologic findings as reference standard. Seven MR pulse sequences were evaluated on the point of accurate delineation of tumor from surrounding normal tissue in each specimen. Results: In specimens of CRC, both imaging modalities of MRI (91.1%) and US (86.7%) showed relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of tumor. In early CRC, diagnostic accuracy of US was 87.5% and that of MRI was 75.0%. There was no statistically significant difference between two imaging modalities (p > 0.05). The best pulse sequence among seven MR sequences for accurate delineation of tumor from surrounding normal tissue in each specimen of CRC was fast spin echo T2 weighted image. Conclusion: MRI and US show relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of resected specimen of CRC. The most excellent pulse sequence of MRI for accurate delineation of tumor from surrounding normal tissue in CRC is fast spin echo T2 weighted image.

Evaluation of the Solitary Pulmonary Nodule by Spiral Computed Topography with Contrast Enhancement (고립성 폐결절의 감별에 있어서 나선형 흉부 전산화 단층촬영시 조영증강의 의의)

  • Song, Kwang Seon;Shin, Kye Chul;Yong, Suk Joong;Ryu, Jeong Seon;Kang, Sin Goo;Kim, Chong Ju;Sung, Ki Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.519-526
    • /
    • 1996
  • Background : Clinical and Radiographic studies to differentiate benign from malignant pulmonary nodules have previously focused on clinical status and the morphologic and the computed tomographic attenuation characteristics of the lung nodules. Distinctive differences in the vascularity and pathophysiology of malignant versus benign pulmonary nodules were identified. We evaluated the diagnostic method for differentiating malignant from benign solitary pulmonary nodule by contrast enhancement on the spiral CT. Method : Sixteen patients with solitary pulmonary nodule were examined(Tuberculoma 8, primary lung cancer 8). Serial thin section on the spiral CT was performed before and after(45second, 2min, 5min) the onset of the injection of 100mL of nonionic contrast material(2mL/sec). Results : There was no difference in size of nodule and pre-contrast CT number (Hounsfield unit) between benign and malignant nodules. At forty-five second after the onset of the injection, malignant neoplasms($19.6{\pm}7.9$ HU) enhanced significantly more than tuberculomas($4.9{\pm}9.4$ HU, p=0.008). At 2minute and 5 minute after, malignant neoplasms($34.0{\pm}19.2$HU, $34.0{\pm}15.4$HU) enhanced significantly more than tuberculomas ($6.7{\pm}9.7$HU, p=0.007 and $7.7{\pm}11.5$HU, p=0.011). On cut-off value 20HU(contrast enhancement) 2minute after the injection of contrast media, sensitivity was 87% and specificity was 87%. No correlation between the contrast enhancement and size of the nodules was observed. Conclusion : Studies with the use of an intravenously administered noniodinated contrast medium in examining the enhancement properties of lung nodules was performed. The contrast enhancement was useful in differential diagnosis of solitary pulmonary nodules.

  • PDF

EVALUATION OF OSTEOGENIC ACTIVITY AND MINERALIZATION OF CULTURED HUMAN DENTAL PAPILLA-DERIVED CELLS (배양된 치유두 유래세포의 조골활성 및 골기질 형성의 평가)

  • Park, Bong-Wook;Byun, June-Ho;Choi, Mun-Jeoung;Hah, Young-Sool;Kim, Deok-Ryong;Cho, Yeong-Cheol;Sung, Iel-Yong;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.4
    • /
    • pp.279-288
    • /
    • 2007
  • In the present study, we focused on stem cells in the dental papilla of the tooth germ. The tooth germ, sometimes called the tooth bud, is the primordial structure from which a tooth is formed. The tooth germ consists of the enamel organ, the dental papilla, and the dental follicle. The dental papilla lies below a cellular aggregation of the enamel organ. Mesenchymal cells within the dental papilla are responsible for formation of dentin and pulp of a tooth. Tooth germ disappears as a tooth is formed, but that of a third molar stays in the jawbone of a human until the age of 10 to 16, because third molars grow slowly. Impacted third molar tooth germs from young adults are sometimes extracted for orthodontic treatment. In the present study, we evaluated the osteogenic activity and mineralization of cultured human dental papilla-derived cells. Dental papillas were harvested from mandible during surgical extraction of lower impacted third molar from 3 patients aged 13-15 years. After passage 3, the dental papilla-derived cells were trypsinized and subsequently suspended in the osteogenic induction DMEM medium supplemented with 10% fetal bovine serum, 50 g/ml L-ascorbic acid 2-phosphate, 10 nM dexamethasone and 10 mM -glycerophosphate at a density of $1\;{\times}10^6\;cells/dish$ in a 100-mm culture dish. The dental papilla-derived cells were then cultured for 6 weeks and the medium was changes every 3 days during the incubation period. Dental papilla-derived cells showed positive alkaline phosphatase (ALP) staining during 42 days of culture period. The formation of ALP stain showed its maximal manifestation at day 7 of culture period, then decreased in intensity during the culture period. ALP mRNA level was largely elevated at 1 weeks and gradually decreased with culture time. Osteocalcin mRNA expression appeared at day 14 in culture, after that its expression continuously increased in a time-dependent manner up to day 28. The expression remained constant thereafter. Runx2 expression appeared at day 7 with no detection thereafter. Von Kossa-positive mineralization nodules were first present at day 14 in culture followed by an increased number of positive nodules during the entire duration of the culture period. Osteocalcin secretion was detectable in the culture medium from 1 week. The secretion of osteocalcin from dental papilla-derived cells into the medium greatly increased after 3 weeks although it showed a shallow increase by then. In conclusion, our study showed that cultured human dental papilla-derived cells differentiated into active osteoblastic cells that were involved in synthesis of bone matrix and the subsequent mineralization of the matrix.

Analysis on the Decrease of Planning Target Volume in the Case of Lung Radiation Surgery with the Application of Respiratory Gated Radiotherpy Method (폐암 환자의 방사선수술 시 호흡연동 방사선치료 방법의 적용을 통한 계획용표적체적 감소 효과 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mee-Sun;Jung, Jae-Uk
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.263-268
    • /
    • 2008
  • The application of a respiratory gated radiotherpy method to the lung radiation surgery was evaluated compared with the conventional method in which the whole tumor motion range is considered in the delineation of PTV (Planning target volume). The four dimensional CT simulation images were acquired for the five NSCLC (Non-small cell lung cancer) patients for radiation surgery. The respiratory gated plan was prepared with the 50% phase CT images and the conventional method was planned based on the ITV (Internal target volume) which include all the target volumes created in each phase CT images within a whole respiratory period. The DVH (Dose volume histogram) of OAR (Organ at risk) which calculated in each method was compared for the evaluation of the plan properness. The relative decrease of OARs' DVH were verified in the application of respiratory gated method. The average decrease rate were $16.88{\pm}9.97%$ in the bronchus, $34.13{\pm}19.15%$ in the spinal cord, $28.42{\pm}18.49%$ in the chest wall and $32.48{\pm}16.66%$ in the lung. Based on these results, we can verified the applicability and the effectiveness of the respiratory gated method in the lung radiation surgery.

  • PDF

Comparison of Dose When Prescribed to Point A and Point H for Brachytherapy in Cervical Cancer (자궁경부암 근접치료에서 A점과 H점을 이용한 치료계획 시 선량 비교)

  • Gang, Ji-Hyeong;Gim, Il-Hwan;Hwang, Seon-Boong;Kim, Woong;Im, Hyeong-Seo;Gang, Jin-Mook;Gim, Gi-Hwan;Lee, Ah-Ram
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.61-66
    • /
    • 2012
  • Purpose: The purpose of this study is to compare plans prescribed to point A with these prescribed to point H recommended by ABS (American Brachytherapy Society) in high dose rate intracavitary brachytherapy for cervical carcinoma. Materials and Methods: This study selected 103 patients who received HDR (High Dose Rate) brachytherapy using tandem and ovoids from March 2010 to January 2012. Point A, bladder point, and rectal point conform with Manchester System. Point H conforms with ABS recommendation. Also Sigmoid colon point, and vagina point were established arbitrarily. We examined distance between point A and point H. The percent dose at point A was calculated when 100% dose was prescribed to point H. Additionally, the percent dose at each reference points when dose is prescribed to point H and point A were calculated. Results: The relative dose at point A was lower when point H was located inferior to point A. The relative doses at bladder, rectal, sigmoid colon, and vagina points were higher when point H was located superior to point A, and lower when point H was located inferior to point A. Conclusion: This study found out that as point H got located much superior to point A, the absorbed dose of surrounding normal organs became higher, and as point H got located much inferior to point A, the absorbed dose of surrounding normal organs became lower. This differences dose not seem to affect the treatment. However, we suggest this new point is worth being considered for the treatment of HDR if dose distribution and absorbed dose at normal organs have large differences between prescribed to point A and H.

  • PDF

In Vitro Imaging of MRI and Ultrasound for Gastric Carcinoma (위암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Kil, Sung-Won;Jee, Keum-Nahn
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.178-187
    • /
    • 2008
  • Purpose : To evaluate and compare the diagnostic accuracy of MRI and ultrasound(US) for estimation of invasion depth of gastric carcinoma by correlation with histopathologic findings in vitro and to find out the best MR pulse sequence for detection and accurate delineation of tumor. Materials and Methods : Resected specimen of total or subtotal gastrectomy from 53 patients with gastric carcinoma were done of imaging studies of MRI and US. And US was examined by using high frequency linear transducer for tumor invasion depth by a radiologist. In each case, both imaging findings of MRI and US were evaluated independently for tumor detection and invasion depth by consensus of two radiologists and were compared the diagnostic accuracy between two imaging modalities according to the histopathologic findings. MR imaging with five MR pulse sequences, spin echo T1 and in- and out-of phase gradient echo T1 weighted images, FSE and SSFSE T2 weighted images, were performed. Five MR pulse sequences were evaluated and compared on the point of detection and accurate distinction of tumor from surrounding normal tissue. Results : In EGC, diagnostic accuracy of US(77%) was superior than that of MRI(59%) but no statistically significant difference was noted between two imaging modalities(p=0.096). In AGC, both imaging modalities of MRI and US showed relatively high diagnostic accuracy as 97% and 84% respectively. Diagnostic accuracy of MRI was statistically better than that of US at the significant level(p<0.001). The best MR pulse sequence among five in each specimen was FSE T2WI(75.5%, 40/53) in both EGC and AGC. In AGC, FSE T2WI showed excellent imaging quality by showing very high ratio (93.5%, 29/31) of accurate delineation of tumor. Conclusion : MRI and US show relatively high diagnostic accuracy in the evaluation of tumor invasion depth of resected specimen in AGC. The most excellent pulse sequence of MRI for the evaluation of tumor invasion depth is FSE T2WI on the point of detection and accurate delineation of tumor in both EGC and AGC.

  • PDF

Association of Periodontitis with Serum Vitamin D Level among Korean Adults (한국 성인의 비타민 D와 치주질환의 관계)

  • Kim, Jaemin;Hwang, Hee-jin
    • Journal of dental hygiene science
    • /
    • v.18 no.4
    • /
    • pp.210-217
    • /
    • 2018
  • Periodontal disease is a chronic inflammatory disease that affects quality of life and nutrition. Several studies have demonstrated a link between periodontal disease and low bone density, and vitamin D is expected to have a beneficial effect on periodontal disease as well as on bone mineral density and anti-inflammatory effects. The purpose of this study was to identify the association between periodontal disease and vitamin D because the results are different in some studies and there is a lack of research in Korea. In this study, we conducted a multiple linear regression analysis of 8,783 subjects among 23,626 subjects who were older than 20 years of age, who had serum vitamin D levels and periodontal disease, who had three years of the National Health and Nutrition Survey that was conducted in Korea from 2012 to 2014. We examined the relationship between serum vitamin D levels and periodontal disease. Tooth loss and vitamin D levels were negatively correlated (${\beta}=-0.028$, p=0.008). In addition, the prevalence of periodontal disease was found to be higher in men younger than 50 years of age with lower vitamin D levels (Q1: 1.769 [1.125~2.782], Q2: 1.182 [0.743~1.881], Q3: 0.676 [0.400~1.881]; p=0.001). Low vitamin D levels and periodontal disease are common diseases in primary care. Vitamin D supplementation is expected to have favorable effect on periodontal disease and falls, osteoporosis, osteoarthritis, and cancer. Therefore, patients with periodontal disease may benefit from periodic vitamin D management to improve quality of life as well as to manage periodontal disease. In addition, as shown in this study, not only elderly individuals, but also men younger than 50 years of age are related to periodontal disease, so there should be interest in controlling the levels of vitamin D in adults.

The Evaluation of Hybrid-Volumetric Modulated Arc Therapy for Lung Cancer Radiation Therapy (폐암 방사선 치료 시 Hybrid-Volumetric Modulated Arc Therapy의 유용성 평가)

  • Lee, Geon Ho;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Du Sang;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.19-26
    • /
    • 2017
  • Objectives: In the Lung, the VMAT rotates continuously and examines radiation. That increases the low doses to normal lung. Due to that, the incidence of radiation pneumonia among radiation side effects may increase. The cause of radiation pneumonia is the lower dose area of the lungs. The H-VMAT was applied to patients who applied to reduce radiation in the lower doses of the lungs. We wanted to assess the usefulness of the H-VMAT by comparing the radiation doses to the low dose areas of the lungs and the normal organs. Materials and Methods: A total of 26 patients who applied for a H-VMAT procedure were applied to the patient. The prescription dose applied to total dose 44 Gy from 22 divisions. For each patient, a plan was implemented with Conventional RT, VMAT and H-VMAT. Conventional RT was carried out in four to five fields each, considering the size, location, shape, and location of the PTV. In the case of a VMAT plan, the two Half ARC, three Half ARC method and the two Full ARC were planned. The H-VMAT was planned by adding two Static fields in the VMAT, taking into account the dose of the lung and the tolerance dose of the organs. Results: In the NSCLC, the lung doses $V_5$ and $V_{10}$ of the lungs except for the treatment plan volume were the lowest with $55.40{\pm}13.39%$ and $32.05{\pm}11.37%$ of H-VMAT. And, in the SCLC, the lung doses of V5 and V10 were the lowest at $64.32{\pm}16.15%$ and $35.50{\pm}9.91%$, respectively. The spinal dose of VMAT in NSCLC was $21.15{\pm}4.02Gy$, which was 7.94 Gy lower than other treatment methods. The lowest spinal dose was delivered at $19.72{\pm}1.82Gy$ for SCLC. The mean dose delivered to the esophagus was also $17.44{\pm}2.04Gy$ and $17.84{\pm}9.20Gy$ in SCLC and NSCLC, respectively. Conclusion: When comparing the value of the surrounding normal organ dose, the VMAT showed that less doses were transmitted from the heart, esophagus and spinal cord than the rest of the treatment plan. However, it was similar to VMAT in normal organs except for the spinal cord. VMAT has increased doses of some normal organs but did not exceed the tolerance dose. It showed a low value in $V_5$, $V_{10}$. When comparing Conventional RT, VMAT, and H-VMAT, If the dose to the heart, esophagus and spinal cord is lower than the tolerance dose, it is thought to reduce the incidence of radiation pneumonia by applying H-VMAT that show the benefits of low doses of the lungs.

  • PDF

Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study (Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • Purpose Respiratory motion during PET/MRI acquisition may result in image blurring and error in measurement for volume and quantification of lesion. The aim of this study was to evaluate changes of quantitative accuracy, tumor size and image quality by applying MR based respiratory motion correction technique (MBRMCT) using integrated PET/MR scanner. Materials and Methods Data of 30 patients (aged $62.5{\pm}10.2y$) underwent $^{18}F-FDG$ liver PET/MR (Biograph mMR 3.0T, Siemens) study were collected. PET listmode data for 7 minutes was simultaneously acquired with maximum average gate (MAG), minimum time gate (MTG) and non gate (NG) T1 weighted MR images. Gated PET reconstruction was performed using mu-maps generated from MAG and MTG by setting 35% of efficiency window. Maximum SUV ($SUV_{max}$), peak SUV ($SUV_{peak}$), tumor size and full width at half maximum (FWHM) in the z-axis direction of MAG, MTG and NG PET images were evaluated. Results Compared to NG, mean $SUV_{max}$ and $SUV_{peak}$ were increased in MAG 13.15%(p<0.0001), 8.66%(p<0.0001), MTG 13.27%(p<0.0001), 8.80%(p<0.0001) and mean tumor size and FWHM were decreased in MAG 14.47%(p<0.0001), 15.49%(p=0.0004), MTG 14.89%(p<0.0001), 15.79%(p=0.0003) respectively. Mean $SUV_{max}$ and $SUV_{peak}$ of MTG were increased by 0.07%(p=0.8802), 0.13%(p=0.7766). Mean tumor size and FWHM of MTG were decreased by 0.49%(p=0.2786), 0.36%(p=0.2488) compared to MAG. There was no statistically significant difference between MAG and MTG which increase total scan time for about 7 and 2 minutes. Conclusion SUV, accuracy of tumor size and spatial resolution were improved in both of MAG and MTG by applying MBRMCT without installing additional hardware in liver PET/MR study. More accurate information can be provided with the increase of 2 minutes scan time if applying MTG of MBRMCT to various abdominal PET/MR studies affected by respiratory motion.

Improving Diagnostic Accuracy for Malignant Nodes and N Staging in Non-Small Cell Lung Cancer Using CT-Corrected FDG-PET (비소세포폐암에서 CT-보정 양전자단층촬영술을 이용한 악성 림프절 평가 및 N 병기 결정 성적 향상)

  • Lee, Eun-Jeong;Choi, Joon-Young;Lee, Kyung-Soo;Chung, Hyun-Woo;Lee, Su-Jin;Cho, Young-Seok;Choi, Yong;Choe, Yearn-Seong;Lee, Kyung-Han;Kwon, O-Jung;Shim, Young-Mog;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.231-238
    • /
    • 2005
  • Purpose: We investigated prospectively whether the interpretation considering the patterns of FDG uptake and the findings of unenhanced CT for attenuation correction can improve the diagnostic accuracy for assessing malignant lymph node (LN) and N stage in non-small cell lung cancor (NSCLC) using CT-corrected FDG-PET (PET/CT). Materials & Methods: Subjects were 91 NSCLC patients (M/F 62/29, age: $60{\pm}9$ yr) who underwent PET/CT before in dissection. We evaluated the maximum SUV (maxSUV), patterns of FDG uptake, short axis diameter, and calcification of LN showing abnormally increased FDG uptake. Then we investigated criteria improving the diagnostic accuracy and correlated results with postoperative pathology. In step 1, in was classified as benign or malignant based on maxSUV only. In step 2, LN was regarded as benign if it had lower maxSUV than the cut-off value of step 1 or it had calcification irrespective of its maxSUV. In step 3, LN regarded as malignant in step 2 was classified as benign if they had indiscrete margin of FDG uptake. Results: Among 432 LN groups surgically resected (28 malignant, 404 benign), 71 showed abnormally increased FDG uptake. We determined the cut-off as maxSUV=3.5 using ROC curve analysis. The sensitivity, specificity, and accuracy for assessing malignant LN were 64.3%, 86.9%, 85.4% in step 1, 64.3%, 95.0%, 93.1% in step 2, and 57.1%, 98.0%, 95.4% in step3, respectively. The accuracy for assessing N stage was 64.8% in step 1, 80.2% in step 2, and 85.7% in step 3. Conclusion: interpreting PET/CT, consideration of calcification and shape of the FDG uptake margin along with maxSUV can improve the diagnostic accuracy for assessing malignant involvement and N stage of hilar and mediastinal LNs in NSCLC.