• Title/Summary/Keyword: Patients Waiting Time

Search Result 155, Processing Time 0.029 seconds

An Investigation of Selection and Transfer Factors on the Admission of Rehabilitation Hospital (재활병원 입원 시 선택 및 전원 요인 조사)

  • Lee, Jae Hong;Kwon, Won An;Lee, Jin Hwan;Min, Dong Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2819-2827
    • /
    • 2013
  • The purpose of his study was to analyze the environmental and the medical factors of prematurely discharged patients in a rehabilitation hospital. The subjects were 107 inpatients. The data were collected using self-report questionnaire and analyzed using the SPSS Win 19.0 program. In result, Firstly, general selection of hospitals was the 'Recommendation' 35.5%, Environmental dissatisfaction factors are Hospital facilities 37.4%. Hospital choice is the highest 'Acquaintances' 23.4%. Second, the lowest group about professionalism, kindness, and description of explanation on satisfaction in survey is group of care workers for the sick. The highest group is physical and occupational therapist. Third, the satisfaction regarding medical procedures of administrative work, waiting time and medical expenses is the highest normal. Hospital facilities in one of the highest factors in environmental dissatisfaction is can be considered as an element of patient departure because of not much number of nervous special hospitals. Medical dissatisfaction factors is the lowest satisfaction of care worker even if those spend much time. this is the focus leaving hospital. Therefore, factors care workers on service satisfaction and dissatisfaction in analysis and problem solving is considered that the need to find ways to improve the quality of service care workers.

Study on Telemedicine system in Medical Law (의료법상의 원격의료 제도에 관한 고찰)

  • Joung, Soon-Hyoung;Park, Jong-Ryeol
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.12
    • /
    • pp.241-249
    • /
    • 2012
  • The rapid development of the current information and communication brings big changes and progress in the health service delivery system. And it is becoming the worldwide trend increasingly. As the name of medical information, by more rapid, detail and more quickly to the patients and diagnosis of the disease it provides not only a high level of health care services but also hospitals and related institutions are making increase the efficiency of the work. Among them, the Telemedicine, that system has many advantage which can expect the shorten the waiting time and the uniform high level of medical, etc. without visiting medical institutions. Especially, the most advantage is it can increase the accessibility of information about extensive medical, without regard to the time and place. But this is the reality, which compared speed the development of modern science and technology with lack of operational regulations and mindset. Current in our Medical Law, it regulates the Telemedicine, but it has Institutional, facility, and environmental constraints. Because, there is no detailed legal relationship. And it takes that in terms of a special form called by a non-face-to-face contact with medical practice rather than the scene. Therefore, in this paper will find a way out to activate the Telemedicine by presupposes the development potential is infinite and find the legal issues and improvements.

Improvement Plans for Increasing Satisfaction among Other Departments Based on The Survey (설문조사를 바탕으로 부서 간 만족도 향상을 위한 개선 안)

  • Park, Ji-Hye;Kim, Nyeon-Ok;Seo, Mi-Hye;Yoo, Soh-Yeon;Park, Hye-Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • Purpose Recently, there has been increasing demands for clinical departments at Asan Medical center in Seoul. They want to see the results of lab tests about blood samples as soon as possible and to be reported to them on the day. As the main contents of the survey, we explained the goodness of Asan medical center's in vitro and the points to be improved. Based on this, it became an opportunity to create a positive image of In vitro laboratory. In addition, we could identify their specific requirements through the surveys. Materials and Methods In September 2016, a total of 14 questionnaire surveys were conducted for 49 clinical departments and outpatient nurses at Asan Medical center in Seoul. The survey consists of description questions to be able to express the intention of the individual and the questions made on the Likert 4 point scale. The main contents of 14 questions are composed of goodness of In Vitro laboratory and points to be improved. Results 62% answered that the best service in In Vitro laboratory was "good accuracy and reproducibility". On the other hand, as an inconvenience when requesting blood tests, 73% pointed out that "the result report time was long", which was recognized as a part to be improved. There are many contents that "The result of all tests is reported within 2 hours" on the day of the examination. In the question - 'Are there some examination results which do not coincide well with clinical observations?', 55 of 56 people answered "no". Above all, the majority answered that waiting for re-examination results is too long. This problem must be causing discomfort to the patients. Conclusion In order to improve these problems, the first thing is to increase the number of blood tests by using the current personnel, equipments and reagents to the fullest by item in Asan Medical Center's Nuclear medicine in vitro part. Secondly, in case of re-examinations, we use the "AMIS message" to show other clinical departments the reporting time. This methode improves the efficiency of work with nurses and increases satisfaction of custom service. Thirdly, the correlation was evaluated by selecting the test species that can be carried out by the shortening method. Currently, C-peptide and insulin are implemented in the reaction process to shorten 2 hours into 1 hour. Finally, we are considering purchasing new equipments for quick test results.

  • PDF

A Modified Protocol for Myocardial Perfusion SPECT Using Natural Plant Extracts for Enhancement of Biliorg Excretion (담즙분비촉진 식물추출물을 이용한 심근관류영상 검사법 개선)

  • Jeong, Hwan-Jeong;Kim, Chang-Guhn
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.364-373
    • /
    • 2003
  • Purpose: For good quality of myocardial perfusion images, an approximately 30 min to 1 hour of waiting time after radiopharmaceutical injection and ingestion of fatty meal are asked of the patients. The aim of this study was to investigate the shortening of waiting time after radiopharmaceutical injection and improvement of image quality using natural plant extracts that promote bile excretion. Materials and Methods: Ten volunteers participated in protocol 1 (7 men, 3 women; mean age, $24.1{\pm}2.4$ years) and protocol 2 (8 men, 2 women; mean age, $26.1{\pm}2.9$ years), respectively. For the modified method of both protocols, subjects took natural plant extracts 15 minutes before the first injection of $^{99m}Tc$ MIBI without laking fatty meals. Control (Conventional) methods were peformed with intake of a fatty meal 20 to 30 minutes after $^{99m}Tc$ MIBI injection. Results: As the results of protocol 1 and 2, the ratio of myocardial to lung ratio were not different between modified and conventional method. Liver to lung ratio of modified method showed significantly lower value than that of conventional method. In modified method, myocardial to liver ratio was higher persistently. In protocol 2, natural plant extracts took before the first injection of $^{99m}Tc$ MIBI exerted accelerating effect of excretion of bile juice into Intestine until the end of examination. Conclusion: These results represent that natural plant extracts for facilitation of bile excretion before injection of $^{99m}Tc$ MIBI may provide better quality of myocardial perfusion images without the need for preparations such as ingestion of fatty meal within the 2 hours compared with conventional method.

Evaluation on the radiation exposure from activated wedge filter (10MV 이상 고에너지 사용시 wedge filler의 방사화가 작업환경에 미치는 영향평가)

  • Lee HwaJung;Kim DaeYoung;Kim WonTaek;Lee KangHyeok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.69-79
    • /
    • 2004
  • In the process of photon treatments, linear accelerators with energies higher than 10 MV produce neutrons through the (${\gamma}$, n) interactions with the composite materials of the linac head md these materials further produce the induced radiations. We investigate the possible risks from these induced radiations especially in the wedge filters to the radiation workers. Wedge filters are used to modify the isodose profiles in the radiation treatment using the linear accelerator and always be handled by the radiation workers. For the background radiation, we measured the radiation in both the waiting room and the outside of the building for two hospitals, S and H. The results of S hospital were $0.11\;{\mu}Sv/hr$ and $0.10\;{\mu}Sv/hr$ for waiting room and outside respectively, and in the case of H hospital, they were $0.12\;{\mu}Sv/hr$ and $0.11\;{\mu}Sv/hr$. Using a survey meter, we measured the radiation from wedge filters inserted in 10 MV and 15 MV Siemens linear accelerators. The time series measurements were done in ${\sim}1$ minutes after exposure of 5 Gy of monitor units for the field size of $25{\times}25cm^2$. The starting value of 10 MV machine was about $3.26\;{\mu}Sv/hr$, which was three times higher than that of 10 MV. The measured radiation was from $^{28}Al$ and $^{53}Fe$ with a half life of 3.5 min. If the treatment patients are $20{\sim}50$ per day and the number of process of wedge filter change per patient is one or two, the annual dose equivalent is $0.08{\sim}0.4\;mSv$ for 10 MV, and $0.27{\sim}1.36\;mSv$ for 15 MV, which are in the range of dose equivalent limits of radiation workers.

  • PDF

Quality Improvement on Upper Gastrointestinal Series (위장조영검사에서 화질 개선 방법)

  • Lim, Byung-Hak;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.395-401
    • /
    • 2016
  • Upper gastrointestinal series is a diagnostic test that X-ray passes through the stomach after administering contrast media such as barium or gastrografin. Upper gastrointestinal series with an advantage of no side effect except temporary constipation or abdominal pain has been widely used to diagnose diseases of the gastrointestinal system. However, image degradation and diagnostic accuracy frequently occurred when improper movement and breath control were carried out by lack of understanding the overall inspection process for the upper gastrointestinal series. The movie of the upper gastrointestinal series was made for improving inspection accuracy and image quality. The examinees encouraged to see the movie for waiting time before doing upper gastrointestinal series. In this study, image quality and diagnostic accuracy was examined for the effect of the movie about upper gastrointestinal series. 60 patients composed of each 10 people from 30s to 80s were selected randomly among both 2,940 examinees in 2014 and 3,076 examinees in 2015. Image quality was evaluated by the full width at half maximum of profile for each image using the Image J. The measurement of the full width at half maximum showed 0.208 mm and 0.133 mm for after and before seeing the movie. Thus it was verified that the movie education could improve the image quality and diagnostic accuracy for upper gastrointestinal series.

A Study of Bone Uptake According to Renal Function in the Whole Body Bone Scan (전신 뼈 검사에서 신장 기능에 따른 뼈 섭취율에 대한 고찰)

  • Cho, Yong-In;Jang, Dong-Gun;Park, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.299-304
    • /
    • 2013
  • Whole body bone scan has been used to confirm bone metastasis and follow-up study with radio isotope. However, if the factors related to $^{99m}Tc$ uptake and waiting time for study are inappropriate, it would be image of low quality. The purpose of present study was to investigate correlation between the evaluation index of renal function and uptake of radiopharmaceuticals. The population for this retrospective study consisted of 387 patients who underwent whole body bone scan between June 2012 and December 2012. As a result of quantitative and qualitative analysis, we were able to confirm that GFR of less than normal range and creatinine levels in blood of more than average are more likely to be under the mean uptake rate. As a result of analysis on the indicator affecting soft-tissue and bone uptake, the correlation of all elements was somewhat low. Also there are no statistically significances due to the other parameters we did not deal with. Therefore, further research on additional factors is needed for exact study and improvement of the image quality.

Gracilis Muscle Transplantation in Neglected Brachial Plexus Palsy (진구성 상완 신경총 마비에 대한 유리박근이식술)

  • Chung, Duke-Whan;Han, Chung-Soo;Ok, Jae-Chul;Cho, Chang-Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • v.6 no.1
    • /
    • pp.73-79
    • /
    • 1997
  • Complete denervation after severe brachial plexus injury make significant muscle atrophy with loss of proper function. It is much helpful to reconstruct the essential function of the elbow flexion movement in patient with total loss of elbow flexion motion after brachial plexus lesion which was not recovered with nerve surgery or long term conservative treatment from onset. In whole arm type brachial plexus injury, if there were no response to neurotization or neglected from injury, the volume of the denervated muscle is significantely reduced month by month. About 18 months most of the muscle fibers change to fibrous tissues and markedly atrophied irreversibly, further waiting is no more meaningful from that period. Authors performed 14 cases of functioning gracilis muscle transfer from 1981 to 1995 with microneurovascular technique, neuromusculocutaneous free flaps were performed for reconstruction of lost elbow flexion function. Average follow-up period was 5 years and 6 months. We used couple of intercostal nerves as a recipient nerve which were anastomosed to muscular nerve from obturator nerve in all cases. Recipient vessels were three deep brachial artery and eleven brachial artery which were anastomosed to medial femoral circumflex artery with end to end or end to side fashion. Average resting length of the transplanted gracilis were 24 cm. We can get average 54 degree flexion range of elbow with fair muscle power from flail elbow. There were one case of muscle necrosis with lately developed thrombosis of microvascular anastomosed site which comes from insufficient recipient arterial condition, 3 cases of partial marginal necrosis of distal skin of the transplanted part which were not significant problem with spontaneously solved with time goes by gracilis muscle has constant neurovascular pattern with relatively easy harvesting donor with minimal donor morbidity. Especially it has similar length and shape with biceps brachii muscle of upper arm and longer nerve pedicle which can neurorrhaphy with intercostal nerve without nerve graft if sufficient mobilization of the nerves from both sides of gracilis and intercostal region. Authors can propose gracilis muscle transplantation with intercostal nerves neurotization is helpful method with minimal donor morbidity for neglected brachial plexus palsy patients.

  • PDF

Inhibition of Porcine Endogenous Retrovirus Expression by RNA Interference (RNA 간섭을 통한 Porcine Endogenous Retrovirus의 발현 억제)

  • Lee, Hyun-A;Koo, Bon-Chul;Kwon, Mo-Sun;Kim, Te-Oan
    • Reproductive and Developmental Biology
    • /
    • v.30 no.3
    • /
    • pp.181-187
    • /
    • 2006
  • In recent years the number of patients waiting for organ transplantation has greatly outpaced the supply of human organs available, which leads to a renewed interest in pig-to-human xenotransplantation as an alternative. However, one of the biggest barriers in the xenotransplantation is presence of porcine endogenous retroviruses(PERV) that can infect human cells. In this study, to present a possible solution for this problem we tried to inhibit expression of PERVs using shRNAs(short hairpin RNA) at the level of RNA synthesis and virus release. The shRNA targeting the sequence of PERV A, B type was cloned into pSIREN-RetroQ vector under the control of polymerase-III U6-RNA gene promoter. Quantitative real-time PCR was performed to detect my alterations in mRNA production of PERV A, B targeted by the shRNA in each done. Depending on the target sequence of the shRNA, the transcription of PERV was decreased to as much as 4% and the number of progeny viruses was reduced to less than 1/200,000. Transgenic pigs producing such shRNAs may result in a highly reduced PERV expression in cells and organs, which is a prerequisite for safe xenotransplantations.

Market in Medical Devices of Blockchain-Based IoT and Recent Cyberattacks

  • Shih-Shuan WANG;Hung-Pu (Hong-fu) CHOU;Aleksander IZEMSKI ;Alexandru DINU;Eugen-Silviu VRAJITORU;Zsolt TOTH;Mircea BOSCOIANU
    • Korean Journal of Artificial Intelligence
    • /
    • v.11 no.2
    • /
    • pp.39-44
    • /
    • 2023
  • The creativity of thesis is that the significance of cyber security challenges in blockchain. The variety of enterprises, including those in the medical market, are the targets of cyberattacks. Hospitals and clinics are only two examples of medical facilities that are easy targets for cybercriminals, along with IoT-based medical devices like pacemakers. Cyberattacks in the medical field not only put patients' lives in danger but also have the potential to expose private and sensitive information. Reviewing and looking at the present and historical flaws and vulnerabilities in the blockchain-based IoT and medical institutions' equipment is crucial as they are sensitive, relevant, and of a medical character. This study aims to investigate recent and current weaknesses in medical equipment, of blockchain-based IoT, and institutions. Medical security systems are becoming increasingly crucial in blockchain-based IoT medical devices and digital adoption more broadly. It is gaining importance as a standalone medical device. Currently the use of software in medical market is growing exponentially and many countries have already set guidelines for quality control. The achievements of the thesis are medical equipment of blockchain-based IoT no longer exist in a vacuum, thanks to technical improvements and the emergence of electronic health records (EHRs). Increased EHR use among providers, as well as the demand for integration and connection technologies to improve clinical workflow, patient care solutions, and overall hospital operations, will fuel significant growth in the blockchain-based IoT market for linked medical devices. The need for blockchain technology and IoT-based medical device to enhance their health IT infrastructure and design and development techniques will only get louder in the future. Blockchain technology will be essential in the future of cybersecurity, because blockchain technology can be significantly improved with the cybersecurity adoption of IoT devices, i.e., via remote monitoring, reducing waiting time for emergency rooms, track assets, etc. This paper sheds the light on the benefits of the blockchain-based IoT market.