• Title/Summary/Keyword: Patients Radiation Dose

Search Result 1,494, Processing Time 0.034 seconds

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.

Lymphopenia after Mediastinal Irradiation in Lung Cancer (폐암환자에서 종격동 방사선조사 후에 발생하는 림프구 감소증)

  • Oh Yoon Kyeong;Ha Chul Soo;Park Hee Chul;Lee Seung Il;Ryu So Yeon;Kee Keun Hong;Jeon Ho Jong
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.34-40
    • /
    • 2002
  • Purpose : This study was undertaken to retrospectively evaluate white blood ceil kinetics, especially lymphocyte depression after different treatments, and to find the correlation between immunosuppression and large blood volume and dynamic blood flow within the mediastinal radiotherapy (RT) field in lung cancer. Materials and Methods : Thirty-four patients with lung cancer were retrospectively evaluated; 10 patients had only radiotherapy (RT group), 8 had chemotherapy (CT group) and 16 fad chemotherapy and radio-therapy (RT/CT group). The mean follow-up periods of the RT-including groups (RT group and RT/CT group) and the RT-excluding group (CT group) were 6 and 8 months, respectively. Complete blood cell counts including lymphocyte percentage $(\%)$ were checked weekly during RT but less frequently during CT and after RT and after RT. Results : Changes in total white blood cell counts were not significantly different among the three groups. The lymphocyte count and lymphocyte $\%$ were much lower in the RT-including groups than in the RT-excluding group. The difference between pre-treatment and final lymphocyte count and the difference between pre-treatment and final lymphocyte $\%$ were significant (p=0.044 and p=0.037) between the RT-including groups and the RT-excluding group. Conclusion : lymphopenia was more marked after treatment containing RT than CT only. Lymphopenia may be one cause of a compromised immune system after mediastinal irradiation in lung cancer. We suggest cautiously that previous studies showing evidence of lymphocyte apoptosis after low-dose irradiation and large blood volume and dynamic blood flow within the RT fields could be somewhat related to lymphopenia after mediastinal irradiation.

Evaluation of Usefulness according to Environmental Change of Auditory and Visual in Pediatric X-ray (소아 X선 촬영에서 청각과 시각의 환경변화에 따른 유용성 평가)

  • Baek, Sung-Wook;Song, Jong-Nam;Kim, Jeong Hun;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.605-610
    • /
    • 2017
  • Unlike adults, cognitive ability and communication are not accurate in pediatric patients. Therefore movement due to psychological anxiety in X-ray photography is one of the factors that increase repeated irradiation. In order to minimize the rejection of X-ray and to improve the satisfaction of medical service, it is necessary to improve the environment of the radiological room to help psychological stability and to find a positive measure for reduction of radiation dose, including unnecessary. The subjects of this study were 186 pediatric patients from May to July, 2017, who were from 6 months to 36 months, The study group was set up a radiological room without auditory and visual environment changes is A group, except for changes in visual environment, the room where only auditory environmental changes were applied was group B, the auditory environment changes were excluded, and the room where only the visual environment change was applied was divided into group C, the auditory and visual environment changes were applied to the D. In group A, 10 retrospectives were obtained, 7 in group B, 5 in group C, and 2 in group D. Especially in group A and group D, statistically significant at p <0.053 In conclusion, hearing and visual environment changes affected the psychological stability of pediatric patient, and the repeated irradiation was reduced, thus improving the quality of medical services.

Usefulness of the Salivary Gland Scan Using $^{99m}Tc$-pertechnetate after Radiotherapy in Patients with Head and Neck Cancer (방사선 치료에 따른 $^{99m}Tc$-pertechnetate를 이용한 이하선과 악하선 기능 검사의 유용성)

  • Kim, Jong-Jin;Hong, In-Soo;Lee, Jong-Young;Kim, Myung-Soon;Sung, Ki-Joon;Park, Jin-Sook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.3
    • /
    • pp.325-331
    • /
    • 1996
  • Purpose : To assess the functional change of salivary gland, recovery of salivary destruction, difference of susceptibility to irradiation between the parotid and sub-mandibular gland, correlation between the xerostomia and excretory rate by irradiation in salivary scan using $^{99m}Tc$-pertechnetate in patients with head and neck cancer. Materials and Methods : We evaluated 19 patients with head and neck cancer who had taken $^{99m}Tc$-pertechnetate salivary gland scan before, during and after radiotherapy. We measured the uptake of radioactivity every 5 minutes for 60 minutes after injection of $^{99m}Tc$-pertechnetate(370MBq). We also evaluated the first excretory function stimulated by 5% citric acid at 30 minutes after injection of $^{99m}Tc$-pertechnetate and then the second excretory function stimulated by 10% citric acid at 45 minutes. Results : The mean uptake curves showed a sharp increase at the 1st week of radiotherapy and then showed a gradual decrease afterwards during radiotherapy. And the mean uptake curves after radiotherapy Persistently decreased on follow up scans without being recovered. The excretory rates decreased gradually as radiation dose increased and were not recovered after radiotherapy. Our study was not satisfactory enough to show the difference of susceptibility to irradiation between the parotid and salivary gland and the correlation between the symptom of xerostomia and the change of the excretory rates. Conclusion : The parotid and submandibular gland scans using $^{99m}Tc$-pertechnetate are useful in the assessment of the functional change of the salivary gland by radiotherapy and predicted the functional change of the salivary gland until 1 year-follow up scan.

  • PDF

Correlation Between Response to Induction Chemotherapy and Subsequent Radiotherapy in Previously Untreated Patients with Squamous Cell Carcinomas of the Head and Neck (두경부의 악성종양(편평상피암) 환자에서 유도화학요법에 의한 종양의 관해와 방사선치료에 의한 관해의 상호 관계)

  • Park Woo Yoon;Yoo Seong Yul;Koh Kyoung Hwan;Cho Chul Koo;Park Young Hwan;Shim Youn Sang;Oh Kyung Kyoon;Lee Yong Sik
    • Radiation Oncology Journal
    • /
    • v.8 no.2
    • /
    • pp.207-212
    • /
    • 1990
  • To determine the correlation between the response to induction chemotherapy and subsequent radiotherapy we analyzed the clinical records of 60 patients with locally advanced carcinoma of the head and neck retrospectively who had completed a full course ($2\~3$ cycle) of induction chemotherapy and curative radiotherapy in Korea Cancer Center Hospital between 1986 and 1989. Chemotherapy was administeredd with CDDP+Bleomycin (BP) in 20, CDDP+5-FU (FP) in 37, and hybrid of BP and FP in three patients. Radiotherapy was giver conventionally with a dose of 65 to 75 Gy or more over seven to eight weeks according to the size of lesion. Response rates following induction chemotherapy were $80\%$ for the tumors and $879\%$ for the nodes whereas complete reponse rates were $12\%\;and\;13\%$, respectively. Six months after radiotherapy $67\%$ of the tumors and $77\%$ of the nodes achieved a complete response. Among the 48 tumor responders and the 31 nodal responders to chemotherapy,39 ($81\%$) and 28 ($90\%$), respectively, achieved complete response after radiotherapy. Thus, whether or not the tumor and node respond to induction chemotherapy was predictive of the response to subsequent radiotherapy (p<0.0005 in tumor, p<0.0001 in node). By reanalyzing according to disease subsets (i.e. primary site, T-stage, N-stage) this relationship was not observed at T1-T2 disease (p>0.3). Therefore the tumor or node's response to induction chemotherapy is a predictor for subsequent radiotherapy except in T1-T2 tumors, and complete response to radiotherapy can be expected despite the failure of induction chemotherapy in $T_1-T_2$ tumors.

  • PDF

Prophylactic Cranial Irradiation for Acute Lymphoblastic Leukemia in Childhood (소아 급성 림프모구성 백혈병의 예방적 전뇌 방사선조사)

  • Kim, In-Ah;Choi, Ihl-Bhong;Kang, Ki-Mun;Shinn, Kyung-Sub;Kim, Hack-Ki
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.137-147
    • /
    • 1996
  • Purpose : This report is the result f retrospective analysis for children who received prophylactic cranial irradiation combined with intrathecal chemotherapy. Materials and Methods : Ninety children with ALL who had got bone marrow remission after induction chemotherapy received PCI. All but 3 children were treated with a dose of 1800 cGy as a standard regimen. While the PCI was given, all patients received intrathecal chemotherapy. Results : Nine of 90 patients experienced CNS relapse during the duration of follow-up ranged from 36 to 96 months (median 60 months). Three children experienced BM relapse prior to CNS relapse. Therefore, CNS relapse rate as the first adverse event was $6.7\%$. Median time interval of CNS relapse was 16 months from the first day of hematologic complete remission. Eighty-nine percent of patients who had CNS relapse were associated with hematologic relapse. and $78\%$ of CNS relpase occurred during maintenance chemotherapy (on-therapy relapse). The CNS RFS at 2 and 5 years are $68\%$ and $42\%$, respectively with median of 43 months. The Prognostic factors affecting CNS RFS are initial WBC count (cut-off point of 50,000/ul), FAB subtype and CALGB risk criteria. The DFS at 2 and 5 years are 61 and $39\%$, respectively with median of 34 months. The prognostic factors affecting DFS are initial WBC count (cut-off point of 50,000/ul), FAB subtype, POG and CALGB risk criteria. Conclusions : In our study, $6.7\%$ of CNS relapse rate as a first adverse event was comparable with other studies. Various risk criteria was based on age at diagnosis and initial WBC count such as POG and CALGB criteria, had prognostic significance for CNS RFS and DFS. Prospective randomized trial according to prognostic subgroup based on risk criteria and systematic study about neuropsychologic function for long term survivors, are essential to determine the most effective and least toxic form of CNS prophylaxis.

  • PDF

Korean Clinical Imaging Guidelines for the Appropriate Use of Chest MRI (한국형 흉부 MRI 영상 진단 정당성 권고안)

  • Jiyoung Song;Bo Da Nam;Soon Ho Yoon;Jin Young Yoo;Yeon Joo Jeong;Chang Dong Yeo;Seong Yong Lim;Sung Yong Lee;Hyun Koo Kim;Byoung Hyuck Kim;Kwang Nam Jin;Hwan Seok Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.562-574
    • /
    • 2021
  • MRI has the advantages of having excellent soft-tissue contrast and providing functional information without any harmful ionizing radiation. Although previous technical limitations restricted the use of chest MRI, recent technological advances and expansion of insurance coverage are increasing the demand for chest MRI. Recognizing the need for guidelines on appropriate use of chest MRI in Korean clinical settings, the Korean Society of Radiology has composed a development committee, working committee, and advisory committee to develop Korean chest MRI justification guidelines. Five key questions were selected and recommendations have been made with the evidence-based clinical imaging guideline adaptation methodology. Recommendations are as follows. Chest MRI can be considered in the following circumstances: for patients with incidentally found anterior mediastinal masses to exclude non-neoplastic conditions, for pneumoconiosis patients with lung masses to differentiate progressive massive fibrosis from lung cancer, and when invasion of the chest wall, vertebrae, diaphragm, or major vessels by malignant pleural mesothelioma or non-small cell lung cancer is suspected. Chest MRI without contrast enhancement or with minimal dose low-risk contrast media can be considered for pregnant women with suspected pulmonary embolism. Lastly, chest MRI is recommended for patients with pancoast tumors planned for radical surgery.

Dosimetric Comparison of Left-sided Whole Breast Irradiation using a Virtual Bolus with VMAT and static IMRT (좌측 유방의 세기변조 방사선치료 시 Virtual Bolus 적용에 따른 선량 변화 비교 평가)

  • Lim, Kyeong Jin;Kim, Tae Woan;Jang, Yo Jong;Yang, Jin Ho;Lee, Seong Hyeon;Yeom, Du Seok;Kim, Seon Yeong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.51-63
    • /
    • 2019
  • Purpose: Radiation therapy for breast cancer should consider the change in breast shape due to breathing and swelling. In this study, we evaluate the benefit of using virtual bolus for IMRT of left breast cancer. Materials and methods: 10 patients with early breast cancer who received radiation therapy after breastconserving surgery compared the VMAT and IMRT plans using the virtual bolus method and without using it. The first analysis compared the V95%, HI, CI of treatment volume, Dmean, V5, V20, V30 of ipsilateral lung, and Dmean of heart in VMAT plan made using the virtual bolus method(VMAT_VB) to the plan without using it(VMAT_NoVB) in case there is no change in the breast. In IMRT, the same method was used. The second analysis compared TCP and NTCP based on each treatment plan in case there is 1cm expansion of treatment volume. Result: If there is no change in breast, V95% in VB Plan(VMAT_VB, IMRT_VB) and NoVB Plan(VMAT_NoVB, IMRT_NoVB) is all over 99% on each treatment plan. V95% in VMAT_NoVB and VMAT_VB is 99.80±0.17% and 99.75±0.12%, V95% in IMRT_NoVB and IMRT_VB is 99.67±0.26% and 99.51±0.15%. Difference of HI, CI is within 3%. OAR dose in VB plan is a little high than NoVB plan, and did not exceed guidelines. If there is 1cm change in breast, VMAT_NoVB and IMRT_NoVB are less effective for treatment. But VMAT_VB and IMRT_VB continue similar treatment effect compared in case no variation of breast. Conclusion: This study confirms the benefit of using a virtual bolus during VMAT and IMRT to compensate potential breast shape modification.

A Study on the Change of Image Quality According to the Change of Tube Voltage in Computed Tomography Pediatric Chest Examination (전산화단층촬영 소아 흉부검사에서 관전압의 변화에 따른 화질변화에 관한 연구)

  • Kim, Gu;Kim, Gyeong Rip;Sung, Soon Ki;Kwak, Jong Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.503-508
    • /
    • 2019
  • In short a binary value according to a change in the tube voltage by using one of VOLUME AXIAL MODE of scanning techniques of chest CT image quality evaluation in order to obtain high image and to present the appropriate tube voltage. CT instruments were GE Revolution (GE Healthcare, Wisconsin USA) model and Phantom used Pediatric Whole Body Phantom PBU-70. The test method was examined in Volume Axial mode using the pediatric protocol used in the Y university hospital of mass-produced material. The tube voltage was set to 70kvp, 80kvp, 100kvp, and mAs was set to smart mA-ODM. The mean SNR difference of the heart was $-4.53{\pm}0.26$ at 70 kvp, $-3.34{\pm}0.18$ at 80 kvp, $-1.87{\pm}0.15$ at 100 kvp, and SNR at 70 kvp was about -2.66 higher than 100 kvp and statistically significant (p<0.05) In the Lung SNR mean difference analysis, $-78.20{\pm}4.16$ at 70 kvp, $-79.10{\pm}4.39$ at 80 kvp, $-77.43{\pm}4.72$ at 100 kvp, and SNR at 70 kvp at about -0.77 higher than 100 kvp were statistically significant. (p<0.05). Lung CNR mean difference was $73.67{\pm}3.95$ at 70 kvp, $75.76{\pm}4.25$ at 80 kvp, $75.57{\pm}4.62$ at 100 kvp and 20.9 CNR at 80 kvp higher than 70 kvp and statistically significant (p<0.05) At 100 kvp of tube voltage, the SNR was close to 1 while maintaining the quality of the heart image when 70 kvp and 80 kvp were compared. However, there is no difference in SNR between 70 kvp and 80 kvp, and 70 kvp can be used to reduce the radiation dose. On the other and, CNR showed an approximate value of 1 at 70 kvp. There is no difference between 80 kvp and 100 kvp. Therefore, 80 kvp can reduce the radiation dose by pediatric chest CT. In addition, it is possible to perform a scan with a short scan time of 0.3 seconds in the volume axial mode test, which is useful for pediatric patients who need to move or relax.

The Development of Iodine-123 with MC-50 Cyclotron (MC-50 싸이클로트론을 이용한 $^{123}I$ 제법 연구)

  • Suh, Yong-Sup;Yang, Seung-Tae;Chun, Kown-Soo;Lee, Jong-Doo;Han, Hyon-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.286-293
    • /
    • 1991
  • $^{123}I$, which is applied for the thyroid and other in vivo kinetic study, has a special role in life sciences. The 159 KeV $\gamma-ray$ from $^{123}I$ is almost ideally appropriate for the current imaging instrumentation. Its decay mode (electron capture) and short half-life (13.3 hr) reduced the burden of radiation dose to the patients, and its chemical property makes it easy to synthesize the labelling compounds. In this experiment, the production of $^{123}I$ via the nuclear reaction $^{124}Te(p,2n)^{123}I$ with 28 MeV protons was sutdied. $TeO_2$ is used as a target material, because it has good physical properties. The target was prepared with $TeO_2$ powder and was molten into a ellipsoidal cavity (a=14 mm, b=10 mm, $270.8mg/cm^2$ thick) of pure platinum. The irradiation was carried out in the external proton beam with incident energies range from 28 MeV to 22 MeV, and current was $30{\mu}A$. The loss of $TeO_2$ target was significantly reduced by using $4\pi-cooling$ system in irradiation. The dry distillation method was adopted for the separation of $^{123}I$ from irradiated target, and when it was kept 5 minutes at $780^{\circ}C$, its result was quantitative. The loss of the target material $(TeO_2)$ was below 0.2% for each production run and $^{123}I$ from the dry distillation apparatus was captured with 0.01 N NaOH in $Na^{123}I$ form, then the pH of the solution was adjusted to $7.5\sim9.0$ with HC1/NaOH. The $Na^{123}I$ solution was passed through $0.2{\mu}m$ membrane filter, and sterilized under high pressure and temperature for 30 minutes. The production of $^{123}I$ is acceptable for clinical application based on the quality of USP XXI.

  • PDF