• Title/Summary/Keyword: Patient-reported outcome measures

Search Result 43, Processing Time 0.031 seconds

The Quality of Life after Lymphaticovenous Anastomosis in 118 Lower Limb Lymphedema Patients

  • Jin Geun Kwon;Yeongsong Kim;Min Young Jang;Hyunsuk Peter Suh;Changsik John Pak;Vaughan Keeley;Jae Yong Jeon;Joon Pio Hong
    • Archives of Plastic Surgery
    • /
    • v.50 no.5
    • /
    • pp.514-522
    • /
    • 2023
  • Background This is a prospective study on 118 patients who underwent lymphaticovenous anastomosis (LVA) due to secondary lower limb lymphedema between January 2018 and October 2020 to evaluate patients' quality of life (QOL) using the Quality of Life Measure for Limb Lymphedema (LYMQoL) questionnaire. Methods The outcome measurement included the LYMQoL leg scoring system tool evaluating the function, appearance, symptom, mood, and overall outcome. In addition, correlation analysis was performed for three factors: based on International Society of Lymphology (ISL) stages, disease duration, and amount of volume reduction. Results The LYMQoL tool overall satisfaction score significantly increased at all intervals from 4.4 ± 0.2 preoperative to 6.5 ± 0.3 postoperative at 12 months (p < 0.001). Significant findings were seen for each domain scores compared preoperatively and at 12 months: function score (18.6 ± 0.5 to 15.4 ± 0.6), appearance score (17.8 ± 0.5 to 16.0 ± 0.6), symptom score (11.8 ± 0.3 to 8.9 ± 0.4), and mood score (14.5 ± 0.4 to 11.4 ± 0.5; p < 0.05). The correlation analysis between improvement of the overall score and the ISL stage (p = 0.610, correlation coefficient [r] = -0.047), disease duration (p = 0.659, r = -0.041), and amount of limb volume reduction (p = 0.454, r = -0.070) showed no statistical significance. Conclusion The QOL of secondary lower limb lymphedema patients was significantly improved after LVA regardless of the severity of disease, duration of disease, and amount of volume reduction after LVA. Understanding the patient-reported outcome measurement will help the surgeons to manage and guide the expectations of the patients.

Clinical and patient-reported outcomes after recession coverage using modified vestibular incision subperiosteal tunnel access with a volume-stable collagen matrix as compared to a coronally advanced flap with a subepithelial connective tissue graft

  • Chun-Teh Lee;Marlena Lange;Alain Jureidini;Nurit Bittner;Ulrike Schulze-Spate
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.6
    • /
    • pp.466-478
    • /
    • 2022
  • Purpose: Coronally advanced split-or full-thickness (CAST or CAFT) flaps in combination with subepithelial connective tissue grafts (SCTGs) are commonly used in root-coverage procedures despite postoperative pain and bleeding from the graft donor site. Therefore, the modified vestibular incision subperiosteal tunnel access procedure (VISTAX) uses a novel collagen matrix (VCMX) instead of autogenous tissue to address the limitations associated with autogenous tissue grafting. This retrospective study compared the clinical outcomes of VISTAX to the results obtained after using a CAST or CAFT flap in combination with SCTG for root coverage. Methods: Patients with single or multiple adjacent recession I/II defects were included, with 10 subjects each in the VISTAX, CAFT, and CAST groups. Defect coverage, keratinized tissue width, esthetic scores, and patients' perceived pain and dentinal hypersensitivity (visual analogue scale [VAS]) were assessed at baseline, 3 months, and 6 months. Results: All surgical techniques significantly reduced gingival recession (P<0.0001). Defect coverage, esthetic appearance, and the reduction in dentinal hypersensitivity were comparable. However, the VAS scores for pain were significantly lower in the VISTAX group than in the CAFT and CAST groups, which had similar scores (P<0.05). Furthermore, the clinical results of VISTAX and CAFT/CAST generally remained stable at 6 months. Conclusions: The clinical outcomes of VISTAX, CAFT, and CAST were comparable. However, patients perceived significantly less pain after VISTAX, indicating a potentially higher patient acceptance of the procedure. A prospective trial with a longer follow-up period and a larger sample size should therefore evaluate VISTAX further.

Blossom smart expander technology for tissue expander-based breast reconstruction facilitates shorter duration to full expansion: A pilot study

  • Choi, Youna K.;Rochlin, Danielle H.;Nguyen, Dung H.
    • Archives of Plastic Surgery
    • /
    • v.47 no.5
    • /
    • pp.419-427
    • /
    • 2020
  • Background This study evaluated the Blossom system, an innovative self-filling, rate-controlled, pressure-responsive saline tissue expander (TE) system. We investigated the feasibility of utilizing this technology to facilitate implant-based and combined flap with implant-based breast reconstruction in comparison to conventional tissue expansion. Methods In this prospective, single-center, single-surgeon pilot study, participants underwent either implant-based breast reconstruction or a combination of autologous flap and implantbased breast reconstruction. Outcome measures included time to full expansion, complications, total expansion volume, and pain scores. Results Fourteen patients (TEs; n=22), were included in this study. The mean time to full expansion was 13.4 days (standard error of the mean [SEM], 1.3 days) in the combination group and 11.7 days (SEM, 1.4 days) in the implant group (P=0.78). The overall major complication rate was 4.5% (n=1). No statistically significant differences were found in the complication rate between the combination group and the implant group. The maximum patient-reported pain scores during the expansion process were low, but were significantly higher in the combination group (mean, 2.00±0.09) than in the implant group (mean, 0.29±0.25; P=0.005). Conclusions The reported average duration for conventional subcutaneous TE expansion is 79.4 days, but this pilot study using the Blossom system achieved an average expansion duration of less than 14 days in both groups. The Blossom system may accommodate single-stage breast reconstruction. The overall complication rate of this study was 4.5%, which is promising compared to the reported complication rates of two-stage breast reconstruction with TEs (20%-45%).

Hindi version of short form of douleur neuropathique 4 (S-DN4) questionnaire for assessment of neuropathic pain component: a cross-cultural validation study

  • Gudala, Kapil;Ghai, Babita;Bansal, Dipika
    • The Korean Journal of Pain
    • /
    • v.30 no.3
    • /
    • pp.197-206
    • /
    • 2017
  • Background: Pain with neuropathic characteristics is generally more severe and associated with a lower quality of life compared to nociceptive pain (NcP). Short form of the Douleur Neuropathique en 4 Questions (S-DN4) is one of the most used and reliable screening questionnaires and is reported to have good diagnostic properties. This study was aimed to cross-culturally validate the Hindi version of the S-DN4 in patients with various chronic pain conditions. Methods: The S-DN4 is already translated into the Hindi language by Mapi Research Trust. This study assessed the psychometric properties of the Hindi version of the S-DN4 including internal consistency and test-retest reliability after 3 days' post-baseline assessment. Diagnostic performance was also assessed. Results: One hundred sixty patients with chronic pain, 80 each in the neuropathic pain (NeP) present and NeP absent groups, were recruited. Patients with NeP present reported significantly higher S-DN4 scores in comparison to patients in the NeP absent group (mean (SD), 4.7 (1.7) vs. 1.8 (1.6), P < 0.01). The S-DN4 was found to have an AUC of 0.88 with adequate internal consistency (Cronbach's ${\alpha}=0.80$) and a test-retest reliability (ICC = 0.92) with an optimal cut-off value of 3 (Youden's index = 0.66, sensitivity and specificity of 88.7% and 77.5%). The diagnostic concordance rate between clinician diagnosis and the S-DN4 questionnaire was 83.1% (kappa = 0.66). Conclusions: Overall, the Hindi version of the S-DN4 has good internal consistency and test-retest reliability along with good diagnostic accuracy.

Chest wall perforator flaps for partial breast reconstruction: Surgical outcomes from a multicenter study

  • Soumian, Soni;Parmeshwar, Rishikesh;Chandarana, Mihir;Marla, Sekhar;Narayanan, Sankaran;Shetty, Geeta
    • Archives of Plastic Surgery
    • /
    • v.47 no.2
    • /
    • pp.153-159
    • /
    • 2020
  • Background Perforator artery flaps based on the branches of intercostal arteries and lateral thoracic artery can be used for reconstruction after breast-conserving surgery (BCS). Although described more than a decade ago, these have not been adopted widely in clinical practice. We report on short-term and long-term surgical outcomes of partial breast reconstruction using chest wall perforator flaps from a prospective multicenter audit. Methods All patients operated for BCS and partial breast reconstruction using intercostal artery perforator or lateral thoracic artery perforator flaps from January 2015 to October 2018 were included in the analysis. Oncoplastic breast surgeons with appropriate level of training performed all tumor excisions and reconstructions as a single-stage procedure. Patient characteristics, treatment details and surgical outcomes were noted. Specific outcomes recorded were margin re-excision and complication rates. Results One hundred and twelve patients underwent the procedure in the given study period. The median age was 54 years. Median specimen weight was 62.5 g and median volume of excision was 121.4 mL. Fifteen patients (13.39%) underwent a margin re-excision for close or positive margins without additional morbidity. One patient required a completion mastectomy. Eight patients (7.14%) had an early complication. None of the patients required a contralateral symmetrization procedure. The results were comparable across the participating centers. Conclusions Chest wall artery perforator-based flaps are an excellent option for lateral and inferior quadrant partial breast reconstructions. The short and long-term surgical outcomes are comparable across sites and can be performed with minimal morbidity. Patient-reported outcome measures need to be studied.

Effect of Tailored Music Intervention on Intra-operative Anxiety among Those Undergoing Regional Anesthesia (환자의 선호도를 고려한 음악중재가 부분마취 환자의 수술 중 불안에 미치는 효과)

  • Kim, Joo Hee;Baek, Seol Hyang
    • Journal of Korean Clinical Nursing Research
    • /
    • v.14 no.1
    • /
    • pp.187-198
    • /
    • 2008
  • Purpose: Music intervention has long been used in research of patients undergoing surgical operation in reducing anxiety level and improve surgical outcome. However, there are few studies that have considered a patient's music preference. We investigated the effect of the tailored music intervention which chose music according to the patient's preference on anxiety level and vital signs. Method: The subjects were 50 patients who received regional anesthesia for surgical operation at D hospital in Pohang city from April, 2006 to November, 2006. All of the subjects were randomly assigned either music group (30 subjects) or non-music group (20 subjects). As the patients arrived in the operating room, vital signs were monitored until the subjects were transferred to the recovery room, while Spielberger's STAI-KYZ questionnaires were applied twice to measure preoperative and intra-operative anxiety. The data were analyzed by 2-test, t-test, one-way ANCOVA and repeated measures ANOVA using SPSS 12.0/PC+. Results: There were no significant differences between the two groups on vital signs. All of the vital signs increased when the subjects arrived in the operating room, but decreased quickly once the operation began, regardless of the groups. However, the music group reported significantly less intra-operative anxiety, compared to the non-music group (F=15.208, p<.000), when preoperative anxiety was treated as a covariance. Conclusion: The findings support that the use of music which was chosen by patients during the surgery significantly reduced patient's intra-operative anxiety during regional anesthesia.

  • PDF

A Study of the Reliability and Validity of the Korean Version of DSM-5 Symptom Measure-Inattention and Anger for Parent and Guardian of Child Age 6 to 17

  • Shin, Min-Sup;Kim, Bung-Nyun;Cho, Minji;Jang, Mirae;Shin, Hanbyul;Do, Ryemi;Park, Hyungseo;Yoon, Narae;Noh, Gahye;Song, Jae-Won;Ahn, Yebin;Shin, Jiyoon;Jang, Soomin;Noh, Eunjung;Lee, Eunhwa
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.32 no.2
    • /
    • pp.71-78
    • /
    • 2021
  • Objectives: This study was conducted to investigate the reliability and validity of the Korean version of the DSM-5 Level 2 Cross-Cutting Symptom Measure-inattention [Swanson, Nolan and Pelham, version IV (SNAP-IV)] and anger [Patient-Reported Outcome Measurement Information System (PROMIS) Anger] for parents and guardians of children aged 6-17 years. Methods: We included 104 children and adolescents diagnosed with attention-deficit/hyperactivity disorder (ADHD), ADHD with anxiety and depression, depressive disorder, anxiety disorder, and tic disorder with somatic symptoms (ADHD=41, depression=9, anxiety=14, ADHD+anxious depression=11, tic+somatic symptoms=29). Their ages ranged from 8 years to 15 years. The participants' mothers completed the SNAP-IV, PROMIS Anger scale, Korean version of the IOWA Conners Rating Scale (K-IOWA), and Korean ADHD Rating Scale (K-ARS) so that the reliability and validity of the SNAP-IV and PROMIS Anger scales, which are DSM-5 scales for assessing inattention and anger of children and adolescents, could be examined. Results: The reliability coefficient of SNAP-IV (Cronbach's α) was 0.94. The correlation coefficients between SNAP-IV, K-IOWA inattention, and K-ARS inattention scores ranged from 0.73 to 0.86. The mean SNAP-IV scores of the ADHD and the ADHD+anxious depression groups were significantly higher than those of the anxiety and the tic+somatic symptoms groups. The reliability coefficient of the PROMIS Anger was 0.91. The correlation coefficient between PROMIS Anger and K-IOWA oppositional/defiant scores was 0.75. The PROMIS Anger mean score of the ADHD+anxious depression group tended to be higher than that of the other groups. Conclusion: These results suggest that the Korean version of the DSM-5 Level 2 Cross-Cutting Symptom Measure-inattention and anger for parent and guardian of child age 6-17 might be a reliable and valid test and may be useful for screening children and adolescents with ADHD.

Anatomic coracoclavicular ligament reconstruction with triple flip-buttons leads to good functional outcomes and low reduction loss: a case series

  • Raul Aguila;Gonzalo Gana;J Tomas Munoz;Diego Garcia de la Pastora;Andres Oyarzun;Gabriel Mansilla;Sebastian Coda;J Tomas Rojas
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.2
    • /
    • pp.140-147
    • /
    • 2023
  • Background: The management of acromioclavicular (AC) joint dislocation remains controversial. Recently, anatomic coracoclavicular (CC) fixation with a double clavicular tunnel and three flip-buttons has shown promising results. This study aimed to evaluate functional and radiological outcomes in patients with high-grade AC joint dislocation treated with anatomic CC fixation using double clavicular tunnels and three flip-buttons. Methods: A retrospective, unicentric study was performed. The study included patients with high-grade AC joint dislocation who underwent surgery with anatomic CC fixation using double clavicular tunnels and three flip-buttons. Demographic data were obtained from medical records. A functional evaluation using subjective shoulder value (SSV), visual analog scale (VAS), and disabilities of the arm, shoulder, and hand (DASH) questionnaires was performed, and an evaluation of preoperative and postoperative comparative Zanca view images was performed. Factors associated with functional outcomes and radiological AC reduction were analyzed. Results: A total of 83 patients completed follow-up and were included in the analysis. The mean SSV, VAS, and DASH scores were 92.8, 0.8, and 6.4, respectively. Patients who had complications experienced significantly worse functional outcomes (DASH: P=0.037). Suboptimal final AC reduction was observed in nine patients (11.1%), and significantly more frequently in patients older than 40 years (P=0.031) and in surgeries performed more than 7 days after injury (P=0.034). There were two reoperations (2.4%). Conclusions: Anatomic CC fixation with a double clavicular tunnel and three flip-buttons leads to good functional outcomes, low complication rates, and high rates of optimal AC reduction.

Ultrasound-guided internal jugular vein catheterization in critically ill pediatric patients

  • Yang, Eu Jeen;Ha, Hyeong Seok;Kong, Young Hwa;Kim, Sun Jun
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.4
    • /
    • pp.136-141
    • /
    • 2015
  • Purpose: Continuous intravenous access is imperative in emergency situations. Ultrasound-guided internal jugular vein (IJV) catheterization was investigated in critically ill pediatric patients to assess the feasibility of the procedure. Methods: Patients admitted to the pediatric intensive care unit between February 2011 and September 2012 were enrolled in this study. All patients received a central venous catheter from attending house staff under ultrasound guidance. Outcome measures included successful insertion of the catheter, cannulation time, number of cannulation attempts, and number and type of resulting complications. Results: Forty-one central venous catheters (93.2%) were successfully inserted into 44 patients (21 males and 23 females; mean age, $6.54{\pm}1.06$ years). Thirty-three patients (75.0%) had neurological disorders. The right IJV was used for catheter insertion in 34 cases (82.9%). The mean number of cannulation attempts and the mean cannulation time was $1.57{\pm}0.34$ and $14.07{\pm}1.91$ minutes, respectively, the mean catheter dwell time was $14.73{\pm}2.5$ days. Accidental catheter removal was observed in 9 patients (22.0%). Six patients (13.6%) reported complications, the most serious being catheter-related sepsis, which affected 1 patient (2.3%). Other complications included 2 reported cases of catheter malposition (4.6%), and 1 case each of arterial puncture (2.3%), pneumothorax (2.3%), and skin infection (2.3%). Conclusion: The results suggest that ultrasound-guided IJV catheterization can be performed easily and without any serious complications in pediatric patients, even when performed by visiting house staff. Therefore, ultrasound-guided IJV catheterization is strongly recommended for critically ill pediatric patients.

Osteocutaneous flaps for head and neck reconstruction: A focused evaluation of donor site morbidity and patient reported outcome measures in different reconstruction options

  • Kearns, Marie;Ermogenous, Panagiotis;Myers, Simon;Ghanem, Ali Mahmoud
    • Archives of Plastic Surgery
    • /
    • v.45 no.6
    • /
    • pp.495-503
    • /
    • 2018
  • With significant improvements in success rates for free flap reconstruction of the head and neck, attention has turned to donor site morbidity associated with osteocutaneous free flaps. In this review, we address the morbidity associated with harvest of the four most commonly used osteocutaneous flaps; the free fibula flap, the scapula flap, the iliac crest flap and the radial forearm flap. A comprehensive literature search was performed to identify articles relevant to donor site morbidity for these flaps. We assessed morbidity in terms of incidence of delayed healing, chronic pain, aesthetic outcomes, site specific complications and patient satisfaction/quality of life. Weighted means were calculated when sufficient studies were available for review. The radial forearm and free fibula flaps are associated with high rates of delayed healing of approximately 20% compared to the scapular (<10%) and iliac flaps (5%). The radial forearm flap has higher rates of chronic pain (16.7%) and dissatisfaction with scar appearance (33%). For the majority of these patients harvest of one of these four osteocutaneous does not limit daily function at long-term follow-up. The scapular osteocutaneous flap is associated with the lowest relative morbidity and should be strongly considered when the recipient defect allows. The radial forearm is associated with higher morbidity in terms of scarring, fractures, chronic pain and wrist function and should not be considered as first choice when other flap options are available.