• 제목/요약/키워드: Patient radiation exposure

검색결과 379건 처리시간 0.025초

컴퓨터 단층촬영 방사선 노출 관리 시스템 소프트웨어 설계 (System Software Design of Computerized Tomography Radiation Dose Management)

  • 양유미;조상욱;이길흥
    • 디지털산업정보학회논문지
    • /
    • 제10권3호
    • /
    • pp.41-48
    • /
    • 2014
  • This paper provides the design of system software for the management of radiation dose that is generated by using computerized tomography(CT). Recently, the radiation leakage incident of Japanese nuclear power plant was in the news internationally and there is a growing interest not only in nuclear power plant but in medical radiation exposure. In spite of the fact that currently safety management of radiation is under control only the workers of the radiation involved, now the exposure management of patients have been required. As surgery and inspections using the radiation have increased, this medical radiation exposure is increasing too. But it is a real situation that medical institutions don't know the level of radiation exposure applied to the patient. Therefore, a system for managing the radiation exposure of a patient from the medical institution is required. This paper proposes a design of a software program that manages the radiation exposure of CT which is a typical imaging tool to use the radiation in the medical institution. By check the amount of radiation dose and set the limit of dose, we would be of help to optimize the medical exposure of the patient.

갑상선 암의 방사성요오드 치료 시 의료진은 방사선 피폭으로부터 안전한가? (Are Medical Personnel Safe from Radiation Exposure from Patient Receiving Radioiodine Ablation Therapy?)

  • 김창근;김대응
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권4호
    • /
    • pp.259-279
    • /
    • 2009
  • Radioiodine ablation therapy has been considered to be a standard treatment for patient with differentiated thyroid cancer after total thyroidectomy. Patients may need to be hospitalized to reduce radiation exposure of other people and relatives from radioactive patients receiving radioiodine therapy. Medical staffs, nursing staffs and technologists sometimes hesitate to contact patients in radioiodine therapy ward. The purpose of this paper is to introduce radiation dosimetry, estimate radiation dose from patients and emphasize the safety of radiation exposure from patients treated with high dose radioiodine in therapy ward. The major component of radiation dose from patient is external exposure. However external radiation dose from these patients treated with typical therapeutic dose of 4 to 8 GBq have a very low risk of cancer induction compared with other various risks occurring in daily life. The typical annual radiation dose without shielding received by patient is estimated to be 5 to 10 mSv, which is comparable with 100 to 200 times effective dose received by chest PA examination. Therefore, when we should keep in mind the general principle of radiation protection, the risks of radiation exposure from patients are low and the medical personnel are considered to be safe from radiation exposure.

컴퓨터 단층촬영(CT) 방사선 노출 관리 시스템 소프트웨어 설계 (System Software Design of Computed Tomography Radiation Dose Management)

  • 양유미;이길흥;조상욱
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.489-492
    • /
    • 2014
  • 본 논문에서는 컴퓨터 단층활영(CT)을 통해 발생되는 방사선 노출량의 관리를 위한 시스템의 소프트웨어 설계를 제안한다. 방사선 피폭량은 환자의 각 신체 부위별로 민감성의 차이에 따라 다르기 때문에 방사선의 노출량을 관리할 수 있게 되면 결과적으로 환자의 방사선 피폭량을 추정할 수 있다. 최근 일본 원전의 방사선 누출 사건이 국제적으로 뉴스가 되었고 원전 뿐 만아니라 의료용 방사선 피폭까지 폭넓게 관심이 커지고 있다. 현재 방사선 안전관리는 방사선 관계 종사자에 대해서만 관리되고 있지만, 이제는 환자에 대한 피폭 관리까지 요구되고 있다. 우리나라에서 방사선을 이용한 검사와 시술이 증가하여 이에 따른 의료 피폭이 증가하였으나 의료 기관에서는 환자에게 가해지는 방사선 피폭 수치를 알지 못하는 실정이다. 따라서 의료 기관에서 환자의 방사선 피폭을 관리할 수 있는 시스템이 필요하다. 본 논문에서는 의료 기관에서 방사선을 이용하는 대표적인 촬영 도구인 CT의 방사선 노출량을 관리할 수 있는 소프트웨어 설계를 제시한다. 방사선의 노출량을 확인하고 선량의 한도를 설정함으로써 환자의 의료 피폭량을 최적화 하는데 도움이 되고자 한다.

  • PDF

X선 촬영시 피폭선량 및 실내공간선량에 관한 연구 (A Study on the Exposure and Free Space Scattered Dose in Radiography)

  • 안봉선;이규은;선종률
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권2호
    • /
    • pp.26-30
    • /
    • 1998
  • We tried to study in order to furnish the data for medical exposure dose and scattered ray in radiography. As the tables(from 1 to 3) show, we can presume, by means of a concrete numerical value, the amount of results affected by patient radiation exposure dose and somatic effect in radiography. However, there are many difficulties in the difference of exposure factor in each hospital, the accuracy of measuring by tracebility, shortage of exposure dose data especially in the area of children, and portable radiography, etc. In the radiation examination, it is considered if the gained benefit to the patient due to radiation is more than the risk of radiation, then the medical exposure is thought to be justified. Therefore, the radiotechnologists should continually make an effort to develop and study new techniques so as to reduce patient exposure dose.

  • PDF

Radiation safety for pain physicians: principles and recommendations

  • Park, Sewon;Kim, Minjung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • 제35권2호
    • /
    • pp.129-139
    • /
    • 2022
  • C-arm fluoroscopy is a useful tool for interventional pain management. However, with the increasing use of C-arm fluoroscopy, the risk of accumulated radiation exposure is a significant concern for pain physicians. Therefore, efforts are needed to reduce radiation exposure. There are three types of radiation exposure sources: (1) the primary X-ray beam, (2) scattered radiation, and (3) leakage from the X-ray tube. The major radiation exposure risk for most medical staff members is scattered radiation, the amount of which is affected by many factors. Pain physicians can reduce their radiation exposure by use of several effective methods, which utilize the following main principles: reducing the exposure time, increasing the distance from the radiation source, and radiation shielding. Some methods reduce not only the pain physician's but also the patient's radiation exposure. Taking images with collimation and minimal use of magnification are ways to reduce the intensity of the primary X-ray beam and the amount of scattered radiation. It is also important to carefully select the C-arm fluoroscopy mode, such as pulsed mode or low-dose mode, for ensuring the physician's and patient's radiation safety. Pain physicians should practice these principles and also be aware of the annual permissible radiation dose as well as checking their radiation exposure. This article aimed to review the literature on radiation safety in relation to C-arm fluoroscopy and provide recommendations to pain physicians during C-arm fluoroscopy-guided interventional pain management.

임상가를 위한 특집 3 - 치과방사선검사의 방사선안전관리: 국내외 현황 및 전망 (Radiation Safety Management in Dental Radiology: Present Status and Future)

  • 김은경
    • 대한치과의사협회지
    • /
    • 제52권3호
    • /
    • pp.147-152
    • /
    • 2014
  • Recently the patient exposure by medical and dental x-ray examination has grown rapidly and diagnostic radiology represents the largest source of man-made radiation. For the patient protection, the principle of justification and optimization should be followed. All the radiographic examinations have to show a potential benefit to the patient weighing against the potential risk. After they are justified, the radiographic exposure should be kept as low as reasonably achievable, taking into account economic and social factors. For the safe use of radiation in dentistry, the radiation safety management in accordance with the legislation is important. The present status and the future of radiation safety management in dental radiology in Korea and other country will be discussed.

전산화단층촬영장치에서 환자피폭선량 (Patient Radiation Exposure Dose in Computed Tomography)

  • 조평곤
    • 한국방사선학회논문지
    • /
    • 제9권2호
    • /
    • pp.109-115
    • /
    • 2015
  • 전산화단층촬영장치(computed tomography, CT)을 이용한 검사의 경우 방사선량의 분포가 일반 X선 장치와 차이가 있고 검사로 인한 방사선 피폭이 많은 것으로 알려져 있다. 그러나 검사 결과의 정확성에 대한 신뢰도가 높아 그 이용도는 계속적으로 증가하고 있다. 이와 같은 상황을 고려하여 기존에 발표된 자료를 바탕으로 CT장치, CT검사에서 방사선량, 진단참고준위 그리고 검사 시 방사선량 감소 방안에 대해 알아보았다.

중재적 시술 시 팬텀을 이용한 환자의 피폭선량 분석 (TA Study on Patient Exposure Dose Used the Phantom for Interventional Procedure)

  • 강병삼;동경래
    • 대한디지털의료영상학회논문지
    • /
    • 제13권2호
    • /
    • pp.71-76
    • /
    • 2011
  • Because interventional procedure operates looking at premier as real time when perate intervention enemy, by patient is revealed during suitableness time in radiation, side effect such as radiation injury of skin is apt to happen. It established by purpose of study that measure exposure dose that patient receives about these problem, and find solution for radiation injury and repletion method. In this study, we used Rando phantom of identical structure with the human body which becomes accomplished with 4 branch ingredient of the attempt and system equivalent material them and absorbed dose were measured by TLD. According to the laboratory, it shows that operations such as TFCA procedure or uterine myoma embolization are more dangerous than TACE procedure. If both operations are inspected during a short time, it is not affected in being bombed. However, it can lead to palliative agenesis or depilate, definitive agenesis only if operations are repeated more than three times. Dose distibution based on experiment, to reduce radiation exposure to patients result from reduction of scatter ray as we control field size of radiation and protection of side organs except for tumor. also we knew that we can protect patients form radiation exposure, if we increas SOD and decrease SID.

  • PDF

전남 지방에서 치근단방사선사진의 참고 선량 수준 (Reference dose levels for dental periapical radiography in Chonnam Province)

  • 한미라;강병철;이재서;윤숙자;김영희
    • Imaging Science in Dentistry
    • /
    • 제39권4호
    • /
    • pp.195-198
    • /
    • 2009
  • Purpose : To establish reference doses of periapical radiography in Chonnam Province, Korea. Materials and Methods : The target-skin distances were measured for dental patient's 1235 exposures including 345 mandibular molar areas. Each periapical radiation exposure was simulated with exactly the same patients exposure parameters and the simulated radiation doses were measured utilizing Mult-O-Meter (Unfors Instruments, Billadal, Sweden). The measurements were done in 44 dental clinics with 49 dental x-ray sets in Chonnam Province for one or two weeks at each dental clinic during year 2006. Results : The third quartile patient surface doses were 2.8 mGy for overall periapical exposures and 3.2 mGy for periapical mandibular molar exposures. Conclusion : The third quartile patient surface doses in Chonnam Province can be used as a guide to accepted clinical practice to reduce patient radiation exposure for the surveyed reference doses were below the recommended dental periapical radiography dose of 7 mGy by IAEA.

  • PDF

소아 환자에서 방사선 차폐체로 인한 피폭선량과 화질의 변화 (Changes in Exposure Dose and Image Quality due to Radiation Shielding in Pediatric Patients)

  • 이영희;이용기
    • 한국방사선학회논문지
    • /
    • 제14권7호
    • /
    • pp.931-936
    • /
    • 2020
  • 본 연구는 자동노출선량장치을 사용했을 때 생식선 차폐체의 유무와 크기 변화에 따른 소아 환자의 방사선 피폭선량과 화질의 변화를 관찰하기 위하여 수행되었다. X-ray 장비를 이용하여 소아 팬텀의 복부와 생식선에서 차폐체가 없을 때와 3가지 크기의 차폐체를 사용했을 때의 방사선 피폭선량을 측정하였으며, 얻어진 영상을 통하여 SNR과 CNR을 측정하였다. 연구 결과 방사선 차폐체의 크기에 비례하여 생식선의 방사선 피폭선량은 감소하였으나 복부의 방사선 피폭선량은 오히려 증가되는 것으로 나타났으며 화질의 변화는 나타나지 않았다. AEC System 사용으로 인하여 방사선 차폐체로 인하여 증가된 방사선으로 인하여과 피폭되지 않도록 소아 환자의 연령과 몸무게, 신체 크기에 최적화된 크기의 차폐체를 사용하는 것이 효과적이라는 것을 확인할 수 있었다.