• Title/Summary/Keyword: Patient radiation exposure

Search Result 379, Processing Time 0.021 seconds

System Software Design of Computerized Tomography Radiation Dose Management (컴퓨터 단층촬영 방사선 노출 관리 시스템 소프트웨어 설계)

  • Yang, Yu Mi;Cho, Sang Wook;Lee, Kil Hung
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.3
    • /
    • pp.41-48
    • /
    • 2014
  • This paper provides the design of system software for the management of radiation dose that is generated by using computerized tomography(CT). Recently, the radiation leakage incident of Japanese nuclear power plant was in the news internationally and there is a growing interest not only in nuclear power plant but in medical radiation exposure. In spite of the fact that currently safety management of radiation is under control only the workers of the radiation involved, now the exposure management of patients have been required. As surgery and inspections using the radiation have increased, this medical radiation exposure is increasing too. But it is a real situation that medical institutions don't know the level of radiation exposure applied to the patient. Therefore, a system for managing the radiation exposure of a patient from the medical institution is required. This paper proposes a design of a software program that manages the radiation exposure of CT which is a typical imaging tool to use the radiation in the medical institution. By check the amount of radiation dose and set the limit of dose, we would be of help to optimize the medical exposure of the patient.

Are Medical Personnel Safe from Radiation Exposure from Patient Receiving Radioiodine Ablation Therapy? (갑상선 암의 방사성요오드 치료 시 의료진은 방사선 피폭으로부터 안전한가?)

  • Kim, Chang-Guhn;Kim, Dae-Weung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.259-279
    • /
    • 2009
  • Radioiodine ablation therapy has been considered to be a standard treatment for patient with differentiated thyroid cancer after total thyroidectomy. Patients may need to be hospitalized to reduce radiation exposure of other people and relatives from radioactive patients receiving radioiodine therapy. Medical staffs, nursing staffs and technologists sometimes hesitate to contact patients in radioiodine therapy ward. The purpose of this paper is to introduce radiation dosimetry, estimate radiation dose from patients and emphasize the safety of radiation exposure from patients treated with high dose radioiodine in therapy ward. The major component of radiation dose from patient is external exposure. However external radiation dose from these patients treated with typical therapeutic dose of 4 to 8 GBq have a very low risk of cancer induction compared with other various risks occurring in daily life. The typical annual radiation dose without shielding received by patient is estimated to be 5 to 10 mSv, which is comparable with 100 to 200 times effective dose received by chest PA examination. Therefore, when we should keep in mind the general principle of radiation protection, the risks of radiation exposure from patients are low and the medical personnel are considered to be safe from radiation exposure.

System Software Design of Computed Tomography Radiation Dose Management (컴퓨터 단층촬영(CT) 방사선 노출 관리 시스템 소프트웨어 설계)

  • Yang, Yu-mi;Lee, Kil-hung;Cho, Sang-wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.489-492
    • /
    • 2014
  • This thesis provides the design of system software for the management of radiation dose that is generated using computer tomography(CT). Because radiation exposure is different depending on the difference in sensitivity to each part for each of the patient's body, if we will be able to manage an appropriate amount of radiation, it is possible to estimate the radiation exposure of the patient as a result. Recently, radiation leakage incident of Japanese nuclear power plant was in the news internationally and there is a growing interest not only a nuclear power plant, to medical radiation exposure. In spite of the fact that currently safety management of radiation is under control only the workers of the radiation involved, exposure management of patients until now have been required. Surgery and inspection using the radiation in Korea will increase, due to this medical exposure has increased, but it is a reality that medical institution don't know the level of radiation exposure applied to the patient. Therefore a system for managing the radiation exposure of the patient from the medical institution is required. This paper proposes a design of a software program to manage the radiation exposure of CT is an typical imaging tool to use the radiation in the medical institution. By check the amount of radiation dose and set the limit of dose, we would help to optimize the medical exposure of the patient.

  • PDF

A Study on the Exposure and Free Space Scattered Dose in Radiography (X선 촬영시 피폭선량 및 실내공간선량에 관한 연구)

  • Ahn, Bong-Seon;Lee, Kyu-Eun;Seon, Jong-Ryul
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.26-30
    • /
    • 1998
  • We tried to study in order to furnish the data for medical exposure dose and scattered ray in radiography. As the tables(from 1 to 3) show, we can presume, by means of a concrete numerical value, the amount of results affected by patient radiation exposure dose and somatic effect in radiography. However, there are many difficulties in the difference of exposure factor in each hospital, the accuracy of measuring by tracebility, shortage of exposure dose data especially in the area of children, and portable radiography, etc. In the radiation examination, it is considered if the gained benefit to the patient due to radiation is more than the risk of radiation, then the medical exposure is thought to be justified. Therefore, the radiotechnologists should continually make an effort to develop and study new techniques so as to reduce patient exposure dose.

  • PDF

Radiation safety for pain physicians: principles and recommendations

  • Park, Sewon;Kim, Minjung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.35 no.2
    • /
    • pp.129-139
    • /
    • 2022
  • C-arm fluoroscopy is a useful tool for interventional pain management. However, with the increasing use of C-arm fluoroscopy, the risk of accumulated radiation exposure is a significant concern for pain physicians. Therefore, efforts are needed to reduce radiation exposure. There are three types of radiation exposure sources: (1) the primary X-ray beam, (2) scattered radiation, and (3) leakage from the X-ray tube. The major radiation exposure risk for most medical staff members is scattered radiation, the amount of which is affected by many factors. Pain physicians can reduce their radiation exposure by use of several effective methods, which utilize the following main principles: reducing the exposure time, increasing the distance from the radiation source, and radiation shielding. Some methods reduce not only the pain physician's but also the patient's radiation exposure. Taking images with collimation and minimal use of magnification are ways to reduce the intensity of the primary X-ray beam and the amount of scattered radiation. It is also important to carefully select the C-arm fluoroscopy mode, such as pulsed mode or low-dose mode, for ensuring the physician's and patient's radiation safety. Pain physicians should practice these principles and also be aware of the annual permissible radiation dose as well as checking their radiation exposure. This article aimed to review the literature on radiation safety in relation to C-arm fluoroscopy and provide recommendations to pain physicians during C-arm fluoroscopy-guided interventional pain management.

Radiation Safety Management in Dental Radiology: Present Status and Future (임상가를 위한 특집 3 - 치과방사선검사의 방사선안전관리: 국내외 현황 및 전망)

  • Kim, Eun-Kyung
    • The Journal of the Korean dental association
    • /
    • v.52 no.3
    • /
    • pp.147-152
    • /
    • 2014
  • Recently the patient exposure by medical and dental x-ray examination has grown rapidly and diagnostic radiology represents the largest source of man-made radiation. For the patient protection, the principle of justification and optimization should be followed. All the radiographic examinations have to show a potential benefit to the patient weighing against the potential risk. After they are justified, the radiographic exposure should be kept as low as reasonably achievable, taking into account economic and social factors. For the safe use of radiation in dentistry, the radiation safety management in accordance with the legislation is important. The present status and the future of radiation safety management in dental radiology in Korea and other country will be discussed.

Patient Radiation Exposure Dose in Computed Tomography (전산화단층촬영장치에서 환자피폭선량)

  • Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • In case of a CT examinations, there is a difference in the distribution of radiation dose from that of general X-ray equipments, and it has been known to cause a great radiation exposure during the examinations. However, owing to its high reliability on the accuracy of a examinations result, its use has increased continuously. In consideration of such a circumstance, the CT equipment, radiation dose during CT examinations, diagnostic reference level, and solutions to reduce radiation dose were mentioned on the basis of previously reported data.

TA Study on Patient Exposure Dose Used the Phantom for Interventional Procedure (중재적 시술 시 팬텀을 이용한 환자의 피폭선량 분석)

  • Kang, Byung-Sam;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.71-76
    • /
    • 2011
  • Because interventional procedure operates looking at premier as real time when perate intervention enemy, by patient is revealed during suitableness time in radiation, side effect such as radiation injury of skin is apt to happen. It established by purpose of study that measure exposure dose that patient receives about these problem, and find solution for radiation injury and repletion method. In this study, we used Rando phantom of identical structure with the human body which becomes accomplished with 4 branch ingredient of the attempt and system equivalent material them and absorbed dose were measured by TLD. According to the laboratory, it shows that operations such as TFCA procedure or uterine myoma embolization are more dangerous than TACE procedure. If both operations are inspected during a short time, it is not affected in being bombed. However, it can lead to palliative agenesis or depilate, definitive agenesis only if operations are repeated more than three times. Dose distibution based on experiment, to reduce radiation exposure to patients result from reduction of scatter ray as we control field size of radiation and protection of side organs except for tumor. also we knew that we can protect patients form radiation exposure, if we increas SOD and decrease SID.

  • PDF

Reference dose levels for dental periapical radiography in Chonnam Province (전남 지방에서 치근단방사선사진의 참고 선량 수준)

  • Han, Mi-Ra;Kang, Byung-Cheol;Lee, Jae-Seo;Yoon, Suk-Ja;Kim, Young-Hee
    • Imaging Science in Dentistry
    • /
    • v.39 no.4
    • /
    • pp.195-198
    • /
    • 2009
  • Purpose : To establish reference doses of periapical radiography in Chonnam Province, Korea. Materials and Methods : The target-skin distances were measured for dental patient's 1235 exposures including 345 mandibular molar areas. Each periapical radiation exposure was simulated with exactly the same patients exposure parameters and the simulated radiation doses were measured utilizing Mult-O-Meter (Unfors Instruments, Billadal, Sweden). The measurements were done in 44 dental clinics with 49 dental x-ray sets in Chonnam Province for one or two weeks at each dental clinic during year 2006. Results : The third quartile patient surface doses were 2.8 mGy for overall periapical exposures and 3.2 mGy for periapical mandibular molar exposures. Conclusion : The third quartile patient surface doses in Chonnam Province can be used as a guide to accepted clinical practice to reduce patient radiation exposure for the surveyed reference doses were below the recommended dental periapical radiography dose of 7 mGy by IAEA.

  • PDF

Changes in Exposure Dose and Image Quality due to Radiation Shielding in Pediatric Patients (소아 환자에서 방사선 차폐체로 인한 피폭선량과 화질의 변화)

  • Lee, Young-Hee;Lee, Yong-Ki
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.931-936
    • /
    • 2020
  • This study was conducted to observe the changes in radiation exposure dose and image quality of pediatric patients according to the presence and size of the gonadal shield when using the AEC system. X-ray equipment was used to measure the radiation exposure dose in the abdominal and gonads of the pediatric phantom when no shielding body was used and when three different sizes of shielding body were used, and SNR and CNR were measured through the obtained images. As a result of the study, the radiation exposure dose to the gonads decreased in proportion to the size of the radiation shield, but the radiation exposure dose to the abdomen was rather increased, and the image quality did not change. It is recommended to use a shield with a size optimized for the age, weight, and body size of the pediatric patient so as not to be overexposed by the increased radiation due to the radiation shield due to the use of the AEC System. For this purpose, information about the pediatric patient with the nurse It is believed that exchange is necessary.