• Title/Summary/Keyword: Patient radiation dose

Search Result 1,016, Processing Time 0.031 seconds

Fusion of Gamma and Realistic Imaging (감마영상과 실사영상의 Fusion)

  • Kim, Yun-Cheol;Yu, Yeon-Uk;Seo, Young-Deok;Moon, Jong-Woon;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.78-82
    • /
    • 2010
  • Purpose: Recently, South Korea has seen a rapidly increased incidence of both breast and thyroid cancers. As a result, the I-131 scan and lymphoscintigraphy have been performed more frequently. Although this type of diagnostic imaging is prominent in that visualizes pathological conditions, which is similar to previous nuclear diagnostic imaging techniques, there is not much anatomical information obtained. Accordingly, it has been used in different ways to help find anatomical locations by transmission scan, however the results were unsatisfactory. Therefore, this study aims to realize an imaging technique which shows more anatomical information through the fusion of gamma and realistic imaging. Materials and Methods: We analyzed the data from patients who were examined by the lymphoscintigraphy and I-131 additional scan by Symbia Gamma camera (SIEMENS) in the nuclear medicine department of the National Cancer Center from April to July of 2009. First, we scanned the same location in patients by using a miniature camera (R-2000) in hyVISION. Afterwards, we scanned by gamma camera. The data we obtained was evaluated based on the scanning that measures an agreement of gamma and realistic imaging by the Gamma Ray Tool fusion program. Results: The amount of radiation technicians and patients were exposed was generated during the production process of flood source and applied transmission scan. During this time, the radiation exposure dose of technicians was an average of 14.1743 ${\mu}Sv$, while the radiation exposure dose of patients averaged 0.9037 ${\mu}Sv$. We also confirmed this to matching gamma and realistic markers in fusion imaging. Conclusion: Therefore, we found that we could provide imaging with more anatomical information to clinical doctors by fusion of system of gamma and realistic imaging. This has allowed us to perform an easier method in which to reduce the work process. In addition, we found that the radiation exposure can be reduced from the flood source. Eventually, we hope that this will be applicable in other nuclear medicine studies. Therefore, in order to respect the privacy of patients, this procedure will be performed only after the patient has agreed to the procedure after being given a detailed explanation about the process itself and its advantages.

  • PDF

Performance Evaluation of the Tumor Tracking Method Using Beam on/off Interface for the Treatment of Irregular Breathing (호흡이 불규칙한 환자의 치료를 위한 Beam on/off Interface를 이용한 종양 추적 치료 방법의 성능 평가)

  • Lee, Minsik
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.343-349
    • /
    • 2018
  • Dose rate regulated tracking is known to be an efficient method which adaptively delivers tracking treatments when patient breathing is irregular. The Motion Management Interface (MMI, Varian Medical System, CA), which provides beam on/off switching during treatment is available for clinic. Study is to test if delivering the adaptive tumor tracking is feasible for irregular breathing using beam switching with MMI. 55 free breathing RPM traces acquired from lung cancer patients are used. The first day RPM traces of the patients are utilized to design preprogrammed tracking MLC patterns, of which periods are intentionally reduced by 20% in order to catch up the variation of patient breathing irregularity in the treatment day. Eligibility criteria for this technique are the variation of amplitude and period less than 20%. An algorithm which determines beam on/off every 100 ms by considering the preprogrammed (MLC) positions and current breathing positions is developed. Tracking error and delivery efficacy are calculated by simulating the beam-switching adaptive tracking from the RPM traces. Breathing patterns of 38 patients (70%) met the eligibility criteria. Tracking errors of all of the cases who meet the criteria are less than 2 mm (average 1.4 mm) and the average delivery efficacy was 71%. Those of rest of the cases are 1.9 mm and 48%. Adaptive tracking with beam switching is feasible if patient selection is based on the eligibility criteria.

Comparison of Average Glandular Dose in Screen-Film and Digital Mammography Using Breast Tissue-Equivalent Phantom (유방조직등가 팬텀을 이용한 Screen-Film과 Digital Mammography에서의 평균 유선선량)

  • Shin, Gwi-Soon;Kim, Jung-Min;Kim, You-Hyun;Choi, Jong-Hak;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.13-23
    • /
    • 2007
  • In recent years, mammography system is changed rapidly from conventional screen-film system to digital system for application to screening and diagnosis. Digital mammography system provides several advantages over screen-film mammography system. According to the information provided by the manufacturer, digital mammography system offers radiation dose reduction in comparison with screen-film mammography system, because of digital detector, particularly direct digital detector has higher x-ray absorption efficiency than screen-film combination or imaging plate(IP). We measured average glandular doses(AGD) in screen-film mammography(SFM) system with slow screen-film combination, computed mammography(CM) system, indirect digital mammography(IDM) system and direct digital mammography(DDM) system using brest tissue-equivalent phantom(glandularity 30%, 50% and 70%). The results were shown as follows : AGD values for DDM system were highest than those for other systems. Although automatic exposure control(AEC) mode was selected, the curve of the AGD values against thickness or glandularity increased significantly for the SFM system with the uniform target/filter(Mo/Mo) combination. Therefore, the AGD values for the high energy examinations were highest in the SFM system, and those for the low energy examinations were highest in the DDM system. But the curve of the AGD values against thickness and glandularity increased gently for CM system with the automatic selection of the target/filter combination (from Mo/Mo to Mo/Rh or from Mo/Rh to Rh/Rh), and the AGD values were lowest. Consequently, the parameters in mammography for each exposure besides detection efficiency play an important role in oder to estimate a patient radiation dose.

  • PDF

An Analysis of Factors That Affect Image Quality Deterioration in The Potable X-ray Examination on using Digital Wireless Detector (디지털 무선 검출기를 이용한 이동형 X선검사에서 영상품질 저하의 요인분석)

  • Yu, Young-Eun;Lim, Cheong-Hwan;Ko, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.93-100
    • /
    • 2014
  • Recently the development of portable digital wireless imaging system, which acquires digital radiation images by using wireless LAN telecommunications function in an easy and fast way, provides lots of convenience for people. Considering the characteristics of portable imaging tests on emergency and critical patients, this study aims to suggest guidelines for Digital wireless detector by evaluating the effect of de-centering of focus-grid and displacement of subject in detector on the quality of image. The equipments used for this study were Elmo-T6 Digital Mobile X-ray system (SIMAZU Corp.), el' Tor ($14{\times}17$ "Wireless detector), Grid (10:1) and Chest & head phantom. After acquiring post-processing image according to dose increase and de-centering image of grid-focus and head phantom displacement image, this study compared, analyzed and evaluated these images by using a digital image analysis program by Image J. In the change of images based on dose increase, images were rough in the dose of 0.5 mAs, while there was no difference among images in the proper dose of 1~2 mAs and, especially from 2.5 mAs, average value of pixels radically decreased, affecting contrast. Over 3 mAs, contrast dropped due to saturation phenomenon of lungs. As the result of analysis using Image J program, with the increase of displacement between focus-grid and head phantom, the frequency of low pixel value also increase, causing the outline of surface image to disappear, which in turn affects contrast. For better quality imaging, a radiographer must be aware before the time of test that the image quality can be changed based on the critical patient's posture, movement, respiration, displacement of X-ray tube and distance of imaging.

The Radiation Therapy for Spinal Cord Compression in Hematologic Malignancy (혈암에서 발생한 척추압박증상의 방사선 치료)

  • Kim In Ah;Choi Ihl Bohng;Chung Su Mi;Kang Ki Mun;Kay Chul Seong;Choi Byung Ok;Jang Ji Young;Shinn Kyung Sub;Kim Chun Choo
    • Radiation Oncology Journal
    • /
    • v.12 no.3
    • /
    • pp.393-399
    • /
    • 1994
  • Spinal cord compression, an oncologic emergency, is a rare complication of hematologic malignancy Our experience was obtained with a series 32 Patients following retrospective analysis for assessing the role of radiation therapy and identifying the prognostic factors affecting on treatment outcome. Diagnosis was usually made by means of radiologic study such as myelography or computerized tomography (CT) or magnetic resonance imaging (MRI) and neurologic examination. Five cases were diagnosed by subjective symptom only with high index of suspicion. In 31 cases, the treatment consisted in radiation therapy alone and the remained one patient had laminectomy before radiation therapy because of diagnostic doubts. Total treatment doses ranged from 800 cGy to 4000 cGy with median of 2000 cGy. Initially large fraction size more than 250 cGy were used in 13 patients with rapidly progressed neurologic deficit. The clinical parameters considered in evaluating the response to treatment were backache, motor-sensory performance and sphincter function. Half of all patients showed good response. Partial response and no response were noted in $37.5\%$ and $12.5\%$, respectively. Our results showed higher response rate than those of other solid tumor series. The degree of neurologic deficit at that time of diagnosis was the most important predictor of treatment outcome. The elapsed time from development of symptoms to start of treatment was significantly affected on the outcome. But histology of primary tumor total dose and use of initial large fraction size were not significantly affect on the outcome. These results confirmed the value of early diagnosis and treatment especially in radiosensitive hematologic malignancy.

  • PDF

Analysis of the Entrance Surface Dose (ESD) and Contrast Usage of Trance Femoral Cerebral Angiography (TFCA) and Cerebral Computed Tomographic Angiography (CCTA) for Cerebrovascular Disease Examining (뇌혈관 질환 검사를 위한 뇌혈관 조영술(TFCA)과 뇌혈관 전산화 단층 촬영 검사(CCTA)의 입사표면선량(ESD) 및 조영제 사용량 분석)

  • Seo, Young-Hyun;Hong, Cheon-Gi;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.495-502
    • /
    • 2019
  • A typical cerebrovascular disease among cerebrovascular diseases is vascular diseases such as cerebral infarction, cerebral hemorrhage, cerebral aneurysm, cerebrovascular stenosis. If the disease occurs and causes cerebral damage, it may be difficult to recover completely. So that, Must continue to perform health care through examination early. In particular, Because most cerebrovascular disease examining use radiation equipment and Thus this study was to find out how to select about the optimal examining method and X-ray dose decrease method among different examining method though comparison and analysis for the entrance surface dose (ESD) on cerebrovascular examining with Trance Femoral Cerebral angiography (TFCA) and Cerebral Computed Tomographic Angiography (CCTA). Also, want to find out how to select about the optimal examining method for worried patient that contrast medium side effect though measuring and evaluating for contrast usage. Data were collected from 70 patients (43 males and 27 females) who underwent CCTA at Yeosoo region hospital from June 2018 to December 2018 and 61 patients (34 males and 27 females) who underwent TFCA at Pyeongtaek region hospital from June 2018 to November 2018. ESD analysis method collected retrospective data though M-view and PACS PLUS program, Used contrast usage measuring method did reality measuring method. In the analysis using SPSS, the ESD of TFCA was $245.74{\pm}71.91$, which was $32.05{\pm}7.74$ lower than the dose of $277.79{\pm}79.65$ of CCTA ESD, and statistically significant at t = 3.249, p = 0.017 (p<0.05). As a result of the comparison of the total amount of contrast agent, the mean contrast agent used in TFCA was $55.05{\pm}17.68ml$, which was about 14.95 smaller than the amount of contrast agent used in CCTA, and statistically significant t = -4.548, p<0.001. In conclusion, the ESD of TFCA was statistically significantly lower than that of CCTA, and also the used contrast usage was significantly tiny than that of CCTA. Therefore, Select the method to increase the utilization of TFCA for cerebral disease examining, we can consider X-ray dose decrease method at the same time as to decrease side effect of contrast medium.

Efficacy and Safety of Fractionated Stereotactic Radiosurgery for Large Brain Metastases

  • Jeong, Won Joo;Park, Jae Hong;Lee, Eun Jung;Kim, Jeong Hoon;Kim, Chang Jin;Cho, Young Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.3
    • /
    • pp.217-224
    • /
    • 2015
  • Objective : To investigate the efficacy and safety of fractionated stereotactic radiosurgery for large brain metastases (BMs). Methods : Between June 2011 and December 2013, a total of 38 large BMs >3.0 cm in 37 patients were treated with fractionated Cyberknife radiosurgery. These patients comprised 16 men (43.2%) and 21 women, with a median age of 60 years (range, 38-75 years). BMs originated from the lung (n=19, 51.4%), the gastrointestinal tract (n=10, 27.0%), the breast (n=5, 13.5%), and other tissues (n=3, 8.1%). The median tumor volume was 17.6 cc (range, 9.4-49.6 cc). For Cyberknife treatment, a median peripheral dose of 35 Gy (range, 30-41 Gy) was delivered in 3 to 5 fractions. Results : With a median follow-up of 10 months (range, 1-37 months), the crude local tumor control (LTC) rate was 86.8% and the estimated LTC rates at 12 and 24 months were 87.0% and 65.2%, respectively. The median overall survival (OS) and progression-free survival (PFS) rates were 16 and 11 months, respectively. The estimated OS and PFS rates at 6, 12, and 18 months were 81.1% and 65.5%, 56.8% and 44.9%, and 40.7% and 25.7%, respectively. Patient performance status and preoperative focal neurologic deficits improved in 20 of 35 (57.1%) and 12 of 17 patients (70.6%), respectively. Radiation necrosis with a toxicity grade of 2 or 3 occurred in 6 lesions (15.8%). Conclusion : These results suggest a promising role of fractionated stereotactic radiosurgery in treating large BMs in terms of both efficacy and safety.

The Utility of Used a Blowing Agent in PET/CT (발포제를 이용한 PET/CT의 유용성)

  • Kim, Ki-Jin;Rhim, Jae-Dong;Yoo, Se-Jong;Kim, Jeong-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.111-117
    • /
    • 2015
  • When scanning PET/CT, dose not unwrinkle gastric folds can be difficult to diagnose gastric cancer. In this study, we use an blowing agent to evaluate the extension the stomach and usefulness of it. The study enrolled 30 patients who patient with uptake in stomach between January and February 2013. Stomach extension was described as the vertical length of the Water drink group was $61.7{\pm}9.7mm$, horizontal length was $102.5{\pm}17.6mm$ and the vertical length of the Blowing agent group was $74.1{\pm}10.7mm$, horizontal length was $101.5{\pm}14.8mm$ in transverse section. Stomach extension was described as the vertical length of the Water drink group was $109.3{\pm}18.8mm$, horizontal length was $62.7{\pm}18.4mm$ and the vertical length of the Blowing agent group was $123.1{\pm}23.1mm$, horizontal length was $87.6{\pm}14.9mm$ in coronal section. Water drink group SUV decreased 35% and Blowing agent group SUV decreased 56%. Blowing agent group extension was similar or superior than water drink group. Therefore, when using a blowing agent will be able to help clinical.

A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index (Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구)

  • Kim, Jae-In;Lee, Yang-Sub;Jang, Dong-Soo;Jung, Min-Cheol;Bae, Seung-Ho;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF

Effect of Variable Scanning Protocols on the Pre-implant Site Evaluation of the Mandible in Reformatted Computed Tomography (영상재구성 전산화 단층촬영에서 촬영조건의 변화가 하악골 술전 임플란트 부위 평가에 미치는 영향)

  • Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.21-32
    • /
    • 1999
  • Purpose: To evaluate the effect of variable scanning protocols of computed tomography for evaluation of pre-implant site of the mandible through the comparison of the reformatted cross-sectional images of helical CT scans obtained with various imaging parameters versus those of conventional CT scans. Materials and Methods: A dry mandible was imaged using conventional nonoverlapped CT scans with 1 mm slice thickness and helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5. 2.0, 2.5 and 3.0. All helical images were reconstructed at reconstruction interval of 1 mm. DentaScan reformatted images were obtained to allow standardized visualization of cross-sectional images of the mandible. The reformatted images were reviewed and measured separately by 4 dental radiologists. The image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal were evaluated and the distance between anatomic structures were measured by 4 dental radiologists. Results: On image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal and in horizontal measurement. there was no statistically significant difference among conventional and helical scans with pitches of 1.0. 1.5 and 2.0. In vertical measurement. there was no statistically significant difference among the conventional and all imaging parameters of helical CT scans with pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. Conclusion: The images of helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5 and 2.0 are as good as those of conventional CT scans with 1 mm slice thickness for evaluation of predental implant site of the mandible. Considering the radiation dose and patient comfort, helical CT scans with 1 mm slice thickness and pitch of 2.0 is recommended for evaluation of pre-implant site of the mandible.

  • PDF