• Title/Summary/Keyword: Patient positioning

Search Result 186, Processing Time 0.025 seconds

Film Image Transfer System (FITS): An Efficient Method for Proper Positioning of Orthodontic Mini-implants

  • Go, Taek-Su;Kim, Seong-Hun;Nelson, Gerald
    • Journal of Korean Dental Science
    • /
    • v.4 no.1
    • /
    • pp.20-25
    • /
    • 2011
  • Purpose: To describe the newly developed Film image transfer system (FITS) for proper positioning of the orthodontic mini-implant in the narrow interdental space and considerations for better application. Materials and Methods: A patient who was planning to have orthodontic mini-implant treatment on the posterior maxilla was recruited to assess the feasibility of FITS. Dental radiographic film and bite record was taken. And then the film image was transferred on the photographic emulsion coated model using transfer light through film projector (enlarger). After exposing the photo emulsion coating on the model, the image was developed with a working solution for a paper developer and fixed. The surgical guide for the mini-implant was fabricated from the transported FITS data. Results: The completed surgical guide was easily placed intraorally, and allowed a simple and rapid placement of the mini-implant. The site of the implant placement was accurate as planned position. Conclusion: In the reported case, The FITS technique represents an effort to minimize risk to the patient and produce consistently good results based upon accurate information about the anatomy of the implant site.

A Study of Patient Centered Navigation Model for Care Convenience of Large Hospitals Based on Indoor Positioning Technology (실내 측위 기술 기반의 대형병원 진료 편의를 위한 환자 중심형 네비게이션 모델 연구)

  • Park, Chang Min;Yang, Yu Mi;Ryu, Ki Dong;Churn, Jin Hyuk;Cho, Sang Wook;Kim, Woo Je
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2014.01a
    • /
    • pp.409-412
    • /
    • 2014
  • 본 논문에서는 환자가 실내 측위 기술과 스마트폰을 이용하여 대형 병원의 내부에서 진료 동선을 스스로 찾아갈 수 있도록 하는데 도움을 주는 네비게이션 모델을 제안한다. 정보기술의 비약적인 발전과 함께 실내 측위 기술을 결합한 스마트폰의 위치기반 어플리케이션들이 각광 받게 되었다. 또한, 실내 측위와 관련된 응용 서비스도 새로이 창출되어 점차 이에 대한 관심과 그 정확성을 높이기 위한 연구들이 활발하게 이루어지고 있다. 기존의 실내측위 기법들 중 가장 보편적인 것은 Wi-Fi 신호를 이용 하는 삼각측량 기법으로 초기 구축비용이 저렴하며 서비스 제공 가능 범위가 넓어 본 논문에서 다루고자 하는 장소인 병원의 특성에 알맞다. 따라서 본 모델은 Wi-Fi를 이용하여 사용자의 정확한 위치를 추정하고 진료 프로세스에 따라 경로를 안내를 해주는 네비게이션 서비스를 제공한다. 이를 통하여 환자에게는 진료를 위한 효율적인 동선을 제공함과 동시에 대형 병원에서는 인적, 물적 낭비를 줄이는데 도움이 되고자 한다.

  • PDF

Evaluation of Setup When Using C-Rad System in Radiotherapy (방사선치료 시 C-Rad system을 이용한 셋업의 평가)

  • Park, Eun-Tae;Ko, Seong-Jin;Choi, Seok-Yoon;Kim, Jung-Hoon;Kim, Chang-Soo;Kim, Dong-Hyun;Kang, Se-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.5
    • /
    • pp.303-310
    • /
    • 2012
  • In radiotherapy, accurate patient positioning and set up are important factor that treatment can influence success. In generally, the 3-laser system is used when the patient set up. But today the body surface scanning system(C-Rad system) is trying to use. Compare and evaluate the C-Rad system and the 3-laser system to check availability. Head and neck that are no movement of internal organs and easy to apply fixation device are limited. Alderson Rando anthropomorphic phantom and 10 patients who have lesions of head and neck are targeted. C-RAD system's setup error mean and standard deviation are the X axis($0.55{\pm}0.51mm$), Y axis($-0.2mm{\pm}0.523mm$), Z axis($-0.85{\pm}0.587mm$) in the phantom study, and in the patient study X axis($-0.05{\pm}0.621mm$), Y axis($0.075{\pm}0.755mm$) Z axis($-1.025{\pm}0.617mm$). So C-RAD system is better than 3-laser system mostly, but C-RAD system's error rate is a little worse than 3-laser system in the Z axis. When radiation treatment of head and neck, body surface contour scanning system contribute to correct positioning and minimize the set up error.

Studies on changes in bulks of body per dose and in the positioning of duodenum by respiration when treating pancreatic cancer patients with radiation therapy (췌장암 환자의 방사선 치료 시 호흡에 따른 십이지장의 위치 변화 및 선량 당 체적 변화에 대한 연구)

  • Jang, Hyeong-Jun;Chun, Geum-Seong;Park, Yeong-Gyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.51-57
    • /
    • 2014
  • Purpose : In the case of treating pancreatic cancer, the importance is put on the spread of dose. Changes take place in duodenum in accordance with respiration. Thus, in this paper, I am going to trace the positioning of duodenum and the changes in bulks of body per dose by scanning the patients' Kilovoltage Cone-Beam CT using the hospital equipped CT-on rail System. Materials and Methods : Seeing three patients, I have acquired KVCBCT by using CT-on rail System and spotted the change in positioning at duodenum after comparing with the preliminary image of treatment plan by using SYNGO Software. Then, I followed the change in the bulk of duodenum and analyzed the changes in bulks of body on the same dose by transmitting the acquired KVCBCT into Pinnacle, a treatment plan system. Results : The changes in the positioning shall be as set forth like this: 1.2cm, 1.0cm in Left-Right Direction, 0cm, 0.8cm in Craniocaudal Direction, 0.1cm, and 1.0cm in Anterior-Posterior Direction. Patient number one showed that his bulks in body had increased by maximum 460%, minimum 120%, the bulks in patient number two had increased bymaximum 490%, minimum 160%, and the bulks of patient number three had increased by maximum 150%. But Minimum volume decreased 30%. Patient number one showed only a little bit of change at first when compared with the preliminary treatment plan. However, the dose increased the bulks in the patient's body: $V_{10}$ 118%, $V_{20}$ 117%, $V_{30}$ 400%, and $V_{40}$ 480% Conclusion : In treating patients with radiation therapy using 3D-CRT, the dose amount penetrated into duodenum needs to be minimized by planning appropriate treatment beforehand. In order to establish an appropriate treatment plan it is required to comprehend the changes at positioning of the duodenum by respiration and predict the changes in the bulks of duodenum by setting precise Planning Target Volume.

ORTHODONTIC AND/OR PHYSIOLOGIC POSITIONING OF IMPACTED MAXILLARY CENTRAL INCISORS (매복 상악 중절치의 교정적 처치에 관한 임상 증례)

  • Lim, Eun-Kyung;Choi, Yeoung-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.21 no.2
    • /
    • pp.510-517
    • /
    • 1994
  • It is a relatively common clinical experience to see a impacted maxillary central incisor. This is apparent at the dental age of about eight years and over, when the patient is in the early mixed dentition stage. The adjacent teeth may tilt toward the site of the missing tooth with resulting space closure and midline deviation. Most often, the central incisor is impacted labially. The labial impaction has been indicated as the most difficult to manage. Each of the current articles describing labial impactions shows at least one case with mucogingival recession or a minimal zone of attached gingiva. This report described the surgical uncovering and orthodontic-physiologic positioning methods with labially impacted maxillary central incisors. Through surgical exposure and direct bonding of lingual botton, the central incisors were brought into proper eruption path with elastic traction. The case 1 and 2 were treated with the physiologic erupting forces. The case 3 was applied with continuous orthodontic force. The case 1 and 2 resulted in good positioning, good esthetics and adequate width of keratinised gingiva. The case 3 resulted in local inflammation and inadequate width of keratinised gingiva.

  • PDF

Quality Assurance System for Determination of Center Position in X-ray and Proton Irradiation Fields using a Stainless Ball and Imaging Plates in Proton Therapy at PMRC

  • Yasuoka, Kiyoshi;Ishikawa, Satoko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.189-191
    • /
    • 2002
  • In the proton therapy using a gantry system, periodical verification of iso-center position is very important to assure precision of patient positioning system at any gantry angles in proton treatment. In the gantry system, there are three different types of iso-center; 1) in a geometrical view, 2) in an X-ray beam's eye view, 3) in a proton beam's eye view. Idealistically, they would be an identical point. They could, however, be different points. It may be a source of errors in patient positioning. At PMRC, we have established a system of verification for iso-center positions using a stainless ball of 2-cm in diameter and an imaging plate. This system provides the relation among a center of a patient target position, a center of proton irradiation field, and/or a center of X-ray field in accuracy of 50$\square$m in the 2) and 3) views, as images of a center of the stainless ball and a center of a 100 mm${\times}$100 mm-aperture brass collimator recorded on the imaging plate, which is setup at 1-cm behind the ball. In addition, it provides simultaneously the images of the ball and the collimator on an imaging intensifier (II), which is setup downstream of the proton or X-ray beam. We present a method of quality assurance (QA) for calibration of iso-center position in a rotation gantry system at PMRC and the performance of this system. A proton beam position on the 1$\^$st/ scatterer in the nozzle of the gantry affects less sensitive (reduced by a factor of 1/5) to the results of the iso-center position. The effect is systematically correctable. The effect of the nozzle (or the collimator) position is less than 0.5 mm at the maximum extraction (390 mm).

  • PDF

Propofol as an Adjuvant in the Treatment of Cancer-Related Pain -A case report- (암성 통증 관리에 사용된 부가적 진통제로서의 Propofol -증례 보고-)

  • Han, Tae-Hyung;Hwang, Won-Gyoon
    • The Korean Journal of Pain
    • /
    • v.10 no.1
    • /
    • pp.117-120
    • /
    • 1997
  • Cancer is a devastating disease, and the treatment of related pain is an extremely challenging task. Providing adequate analgesia while avoiding unnecessary drug effects often requires a polypharmacologic approach in cancer pain management. A 36-year old woman with breast cancer metastatic to the axial skeleton and bilateral hip joints was admitted to hemato-oncology service with complaints of intractable abdominal and hip pain. Despite rapidly increasing doses of intravenous morphine up to 350 mg per day; transdermal fentanyl; midazolam; ketorolac; lorazepam; dexamethasone, the patient continued to describe her pain as 10 of 10, refusing all surgical/diagnostic interventions not directly related to pain control. She did, however, consent to lumbar epidural catheter placement. The patient was sedated with titrating doses of propofol to assist with positioning. Even though the procedure was not successful due to significant thoracolumbar scoliosis, the patient admitted feeling better than she has in months during attempted placement. After continuous infusion of propofol was initiated at subhypnotic dose, the patient's analgesic demand was drastically reduced and described her pain as "1 to 3" of "10". Approximately 96 hours after the propofol infusion was started, the patient expired comfortably. There had been no change in her medical regimen during fecal 48 hours. In the case described, propofol was extremely advantageous as an adjuvant in the management of cancer related pain.

  • PDF

The Customer Satisfaction Index Model: An Empirical Study of the Private Healthcare Sector in Malaysia

  • ARIFFIN, Ahmad Azmi M.;ZAIN, Norhayati M.;MENON, Bama V.V.;AZIZ, Norzalita A.
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.9 no.1
    • /
    • pp.93-103
    • /
    • 2022
  • The main purpose of this study was to gauge the patient satisfaction index and subsequently discuss the Importance-Performance (IP) matrix analysis of the inpatient services in the context of the private hospital setting. The Malaysian Customer Satisfaction Index Model was employed as the theoretical framework for the above purposes. This study involving 242 patients in Malaysian's private healthcare sector used a Web-based survey as the main method of data collection. Partial least square structural equation modeling (PLS-SEM) was utilized for data analysis. Using Fornell et al. (1996)'s formula, the resulting patient satisfaction index was slightly lower than the "very satisfied" category, the target level required for positioning as one of the world's premier medical tourism players. The IP matrix showed that medical quality is the main competitive advantage of the private hospitals that can propel their growth in the global healthcare marketplace. The results also indicate that outcome quality, patient rights, and privacy, and service quality are the three quality domains that need to be prioritized for further improvement. On the other hand, the servicescape quality domain needs to be strategized as the unique selling proposition as the performance of the private hospitals in this regard is already extremely good.

Feasibility of Automated Detection of Inter-fractional Deviation in Patient Positioning Using Structural Similarity Index: Preliminary Results (Structural Similarity Index 인자를 이용한 방사선 분할 조사간 환자 체위 변화의 자동화 검출능 평가: 초기 보고)

  • Youn, Hanbean;Jeon, Hosang;Lee, Jayeong;Lee, Juhye;Nam, Jiho;Park, Dahl;Kim, Wontaek;Ki, Yongkan;Kim, Donghyun
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.258-266
    • /
    • 2015
  • The modern radiotherapy technique which delivers a large amount of dose to patients asks to confirm the positions of patients or tumors more accurately by using X-ray projection images of high-definition. However, a rapid increase in patient's exposure and image information for CT image acquisition may be additional burden on the patient. In this study, by introducing structural similarity (SSIM) index that can effectively extract the structural information of the image, we analyze the differences between daily acquired x-ray images of a patient to verify the accuracy of patient positioning. First, for simulating a moving target, the spherical computational phantoms changing the sizes and positions were created to acquire projected images. Differences between the images were automatically detected and analyzed by extracting their SSIM values. In addition, as a clinical test, differences between daily acquired x-ray images of a patient for 12 days were detected in the same way. As a result, we confirmed that the SSIM index was changed in the range of 0.85~1 (0.006~1 when a region of interest (ROI) was applied) as the sizes or positions of the phantom changed. The SSIM was more sensitive to the change of the phantom when the ROI was limited to the phantom itself. In the clinical test, the daily change of patient positions was 0.799~0.853 in SSIM values, those well described differences among images. Therefore, we expect that SSIM index can provide an objective and quantitative technique to verify the patient position using simple x-ray images, instead of time and cost intensive three-dimensional x-ray images.

A Study on the Usefulness of an Examination Information Printout during Ordinary X-Ray Examinations (일반촬영 검사 시 검사안내 유인물의 유용성에 관한 고찰)

  • Kang, Sang-Oh;Hong, Seong-Kwon;Son, Seok-Ho;Lee, Min-Woo;Kim, Kyeong-Soo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.1
    • /
    • pp.13-20
    • /
    • 2012
  • In a normal x-ray examination, the cooperation of a patient in positioning greatly influences the improvement of work performance, the quality of the images and the reduction in time spent on the examination. An attempt was made to discover the connection between an examination information printout and the effects of the examination by informing the patient before the examination on the examination positions in order to increase the level of cooperation by the patient and by surveying the degree of satisfaction of the patient during the examination proceedings. An examination information printout was prepared on five positions that patients consider to be difficult while receiving normal x-ray examinations and were shown to 257 male and female patients between the ages of 30 to 79 who had visited this hospital between January 1 to February 29, 2012 or to a person who had accompanied the patients before the examination to research the degree of satisfaction regarding the printout. In addition, the examination explanation printout was given to Radiologic Technologists with over 1 year experience in this hospital to use while taking the x-rays and the degree of satisfaction was surveyed and it was examined if the increase of the degree of satisfaction had an effect on the reduction in the examination time. The patients who utilized the examination information printout revealed results of approximately a 7.8% higher degree of satisfaction among the patients who had previous experience receiving x-ray examinations compared to those were having an x-ray for the first time. In the age groups between 30 to 70 years of age, the age group in the 30's revealed the lowest level of satisfaction at approximately 69% and the group in the 50's showed the highest degree of satisfaction of 87.94%. In the survey of the Radiologic Technologists, 85% responded that they were satisfied. In the question that stated "Will the examination information printouts reduce the time involved in unnecessary conversations with the patients?," the responses showed a 95% degree of satisfaction. The degree of satisfaction was high over the examination information printout by both the patients and the Radiologic Technologists. Although the effects of examination time reduction varied based on the ages of the patients and physical conditions that they were in and could not be given measurement values, it was able to be seen through the survey that reduction of the unnecessary communication between the patient and the Radiologic Technologists contributed to the increase in the degree of satisfaction. As a result, both the patients and the Radiologic Technologists had an increased degree of satisfaction over the examination information printout and it was possible for improvements to be made in the quality of medical service provided as well. Nevertheless, it is considered that a more developed manual in terms of quality and quantity must be produced using a more systematic approach and design.

  • PDF