• Title/Summary/Keyword: Patient card

Search Result 61, Processing Time 0.025 seconds

Manifestation of Cognitive Function in Geriatric Patient with Subjective Memory Complaint (주관적 기억력 저하를 호소하는 노인 환자의 인지기능 양상)

  • Park, Han-Kyul;Kim, Jin-Sung;Lee, Jong-Bum;Seo, Wan-Seok;Koo, Bon-Hoon;Bai, Dai-Seg
    • Journal of Yeungnam Medical Science
    • /
    • v.27 no.1
    • /
    • pp.27-36
    • /
    • 2010
  • Purpose : The purpose of this study was to find out cognitive function of the patients with subjective memory complaint. Material and Methods : From March 1st 2005 to May 31st 2009, 155 normal individuals without any medical illness who visited Yeungnam University Hospital to undergo medical checkup with neurocognitive test was enrolled, and checked by using Cognitive Assessment & Reference Diagnostic System. Results : 107 of the patients had normal cognitive function, 21 patients (about 15%) were diagnosed with dementia, and 10 patients (about 7%) were diagnosed with considerable psychiatric illness, such as depression, anxiety disorder, adjustment disorder. In amnesia, agnosia, aphasia, attention, calculation, dysexecution, Dementia group and Psychiatric illness group has worse score than Normal individuals group. But, in apraxia, Dementia group has worse score than Psychiatric illness group and Normal individual group. Conclusion : Because the patients with subjective memory complaint can be diagnosed as any psychiatric illness as well as dementia, sensitive screening test and early psychiatric approach is needed.

  • PDF

A Study on Virtual Reality Management of 3D Image Information using High-Speed Information Network (초고속 정보통신망을 통한 3차원 영상 정보의 가상현실 관리에 관한 연구)

  • Kim, Jin-Ho;Kim, Jee-In;Chang, Chun-Hyon;Song, Sang-Hoon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.12
    • /
    • pp.3275-3284
    • /
    • 1998
  • In this paper, we deseribe a Medical Image Information System. Our system stores and manages 5 dimensional medical image data and provides the 3 dimensional medical data via the Internet. The Internet standard VR format. VRML(Virtual Reality Modeling Language) is used to represent the 3I) medical image data. The 3D images are reconstructed from medical image data which are enerated by medical imaging systems such ans CT(Computerized Tomography). MRI(Magnetic Resonance Imaging). PET(Positron Emission Tomograph), SPECT(Single Photon Emission Compated Tomography). We implemented the medical image information system shich rses a surface-based rendering method for the econstruction of 3D images from 2D medical image data. In order to reduce the size of image files to be transfered via the Internet. The system can reduce more than 50% for the triangles which represent the surfaces of the generated 3D medical images. When we compress the 3D image file, the size of the file can be redued more than 80%. The users can promptly retrieve 3D medical image data through the Internet and view the 3D medical images without a graphical acceleration card, because the images are represented in VRML. The image data are generated by various types of medical imaging systems such as CT, MRI, PET, and SPECT. Our system can display those different types of medical images in the 2D and the 3D formats. The patient information and the diagnostic information are also provided by the system. The system can be used to implement the "Tele medicaine" systems.

  • PDF

Evaluation of Cognitive Functions in Patients with Narcolepsy (기면병 환자의 인지기능 평가)

  • Jin, You-Yang;Yoon, Jin-Sang;Chung, Eun-Kyung
    • Journal of agricultural medicine and community health
    • /
    • v.38 no.2
    • /
    • pp.97-107
    • /
    • 2013
  • Objective: This study aimed to evaluate attention, memory and executive function in patients with narcolepsy. Methods: This study included 23 narcoleptic patients whose diagnosis were confirmed by the International Classification of Sleep Disorders(ICSD) at Chonnam National University Hospital Sleep Disorders Clinic or an other hospital in Korea, from 2005 to 2008, as well as 23 normal controls. All participants were given an IQ test for Korean-Wechsler Adult Intelligence Scale and several neuropsychological function tests (the d2 test for attention function, the Rey Complex Figure Test for nonverbal memory, the Korean-California Verbal Learning Test [K-CVLT] for verbal memory, and the Wisconsin Card Sorting Test for executive function). Clinical features of narcoleptic patients, including the frequency of excessive daytime sleepiness, cataplexy, sleep paralysis and hypnagogic hallucination, were investigated by a structured clinical interview administered by a neuropsychiatist. Excessive daytime sleepiness was evaluated by the Epworth sleepiness scale. Results: Characteristic symptoms of narcolepsy observed in this study included excessive daytime sleepiness (n=23, 100.0%), cataplexy (n=19, 82.6%), hypnagogic hallucination (n=5, 21.7%) and sleep paralysis (n=12, 52.2%). In nocturnal polysomnographic findings, stage 2 sleep and REM latency were found to be significantly decreased in narcoleptic patients compared with the control group, and were accompanied by significant increases in stage 1 sleep. Narcoleptic patients had lower scores than the control group on total number, Total Number-Total Error, Concentration Performance and Fluctuation Rate on the d2 test, which measures attention. Also, there were significant differences between the performance of patient and control groups on the B list of the K-CVLT, which measures verbal memory. Conclusion: Narcoleptic patients showed decreased attention and verbal memory performance compared to the control group; however, in many areas, narcoleptic patients still demonstrated normal cognitive function.

Liberalization of Telemedicine in Germany (독일 원격의료 합법화와 법개정 논의)

  • Kim, SooJeong
    • The Korean Society of Law and Medicine
    • /
    • v.21 no.2
    • /
    • pp.3-33
    • /
    • 2020
  • Until recently the German and the South Korean medical associations reacted cautiously to the introduction of telemedicine between doctor and patient which is exclusively on the platform conducted. But the General Assembly of German Physicians voted to lift the ban on remote treatment with the amendment to Section 7 (4) MBO-Ä(Medical Association's Professional Code of Conduct) in 2018 and the situation has been fundamentally changed in Germany. From then until now 16 of 17 rural medical associations have changed their professional code to allow telemedicine. In addition the legislature started to prepare the basis for the introduction of the electronic health card (eGK) and the telematics infrastructure. So far, various laws such as Medicinal Products Act, Drug Advertisement Act and Social Code have been changed to support legalization of telemedicine and digitalization of health care. Unlike in Germany, the social circumstances such as excessive centralization of the big hospitals in Seoul and the resulting concern of small medical practices for profitability are the main obstacles to the introduction of telemedicine. However the German approach how to legalise the telemedicine and to prepare for legal and technical infrastructure is also interesting in South Korea. The discussions for and against the changes in the law and the telematics infrastructure attempted by the German government for several years indicate that not only lifting the ban on remote treatment, but also harmonization of all the related legal system could guarantee successful implementation of telemedicine.

Structural and Functional Changes of The Brain in The Patient with Schizophrenia, Paranoid type : Correlation among Brain MRI Findings, Neurocognitive Function and Psychiatric Symptoms (편집형 정신분열병 환자에서 뇌의 구조적 변화와 기능적 변화 : 뇌자기공명영상소견, 신경인지기능 및 정신증상간의 상관관계)

  • Kang, Cheol-Min;Lee, Young-Ho;Jung, Young-Jo;Lee, Jung-Heum;Kim, Su-Ji;Park, Hyun-Jin
    • Sleep Medicine and Psychophysiology
    • /
    • v.5 no.1
    • /
    • pp.54-70
    • /
    • 1998
  • Objectives : The purpose of this study is to evaluate the role of structural and functional changes of the brain in the pathophysiology of schizophrenia. Methods : The authors measured the regions of interest on the magnetic resonance imaging of the brain in 20 patients with paranoid schizophrenia(15 men and 5 women) and 23 control subjects(15 men and 8 women). We also assessed the neurocognitive functions with the Wisconsin Card Sorting Test, the Benton Neuropsychological Assessment, and the Weschler IQ test-Korean version, soft neurologic signs, and psychiatric symptoms in the patient group. Results : In the patient group, all ventricles and basal ganglia including caudate nucleus and globus pallidus were significantly enlarged. Although there were no significant differences between the two groups in the values of right frontal lobe and left temporal lobe, there was a tendency of decrease in the values of right frontal lobe and left temporal lobe. There were significant positive correlations between the values of ventricles and the frequency of previous hospitalization. However, there were no significant correlations between other values of regions of interest and clinical data. The value of the right frontal lobe was significantly correlated with the score of soft neurologic signs, which is suggestive of the neurodevelopmental abnormalities. There were significant correlations between the value of frontal lobe and the scores of the various subscales of Benton Neuropsychiatric Inventory. In contrast, the value of left amygdala and putamen showed significant correlation with the score of verbal IQ on the Weschler IQ test. Structural changes of the temporal lobe areas were related with the positive and general symptom scores on PANSS, while those of the basal ganglia were related with the negative symptom scores. Conclusions : These results suggest that the structural changes of the brain in the patients with schizophrenia show the dual process, which is suggestive that the enlarged ventricle show the neurodegenerative process, while enlarged basal ganglia, and shrinked right frontal and left temporal lobe show the neurodevelopmental abnormalities. Among these changes, structural changes of the frontal lobe related with various neuropsychological deficits, while those of left temporal lobe related with language abnormality. Relative to the relation between structural changes and psychiatric symptoms, structural changes of the temporal lobe areas were related with the positive and general symptoms, while those of the basal ganglia were related with the negative symptoms.

  • PDF

The Attitude of the Bereaved Family Attending a Bereavement Memorial Service (사별가족모임과 관련된 사별가족 태도 연구)

  • Jung, In-Soon;Shim, Byoung-Yong;Kim, Young-Seon;Lee, Ok-Kyung;Han, Sun-Ae;Shin, Ju-Hyun;Lee, Jong-Ku;Hwang, Su-Hyun;Ok, Jong-Sun;Kim, Hoon-Kyo
    • Journal of Hospice and Palliative Care
    • /
    • v.8 no.2
    • /
    • pp.143-151
    • /
    • 2005
  • Purpose: Bereavement Memorial Service has been held every year by the hospice team at St. Vincent's Hospital for the purpose of supporting the bereaved family who feel grief and mourning. The purpose of this study is to find out the attitude of the bereaved attending at bereavement memorial service (BMS) and to find out the areas needing improvements to set up better memorial service. Methods: Hospice team sent invitation card to 180 families of patients who admitted and passed away at hospice ward Nov., 2003${\sim}$Oct., 2004. Among them 22 families attended the BMS meeting, which was held on 26th Nov., 2004. The researcher collected data from 22 families with 'Questionnaire' survey. Except identifying data and 2 dichotomy questions, we used open-ended questionnaire. 1 researcher conducted a telephone interview survey in 18 families who couldn't attend at BMS meeting. Results: The median age was 56 (range $16{\sim}19$) and there were 37 females and 3 males. They were patient's wife (22), mother (4), husband (5), daughter (4), mother-in-law (1), siblings (1), brothers wife (1). Duration after bereavement, $1{\sim}3$ months (17) was the highest frequency. 36 families agreed 'the dead experienced the death with dignity'. The reason of agreement to the death with dignity was 'the patient died in preparation' (16). 'the patient died in well-being condition spiritually' (9), 'the patient died in comfort physically (7). 4. persons thought the dead died with indignity. The bereaved defined 'the death with dignity' as follows: 'acceptance of death & death in spiritual well-being' (9), 'death in physical comfort condition' (7), 'the death in psycho-social well-being' (3), non-respondents (10). Most families (21) were still in difficulty to overcome bereavement grief. The answer regarding the method to overcome the difficulty was 'with spiritual sublimation' (13), 'with devotion of oneself in daily life' (10), 'with devotion to mourning as it is' (3). With regard to their attitude to invitation, 'having joy and thanks from hospice team' (21), 'grief' (4), 'suffering' (4). Toward the existence of hesitation about attendance at BMS meeting, the result as follows. Nonexistence of hesitation respondent (34), existence respondent (6), the reason for hesitation was various; 'the meeting reminds me of the suffering times', 'the meeting makes me to recall, and it will be likely to cry', and so on. The needs and feelings to memorial service meeting were various; 'it was meaningful time', 'it was good to recall about the dead', 'more meeting annually' and so on. In respect of the most difficulty after bereavement, in attendant family, 'depression' (10) was the highest frequency, whereas, in non-attendant family, the most difficult thing was 'financial problem/role difficulty (6). Conclusion: This study shows the rate of attendance was high in bereaved whose bereavement duration $1{\sim}3$ month. Most of bereaved were still suffering from bereavement grief within 1 year. Although most families didn't hesitate and felt positive mood to invitation, the rate of attendance was low. Comparing with two groups between attendant family and non-attendant, the latter felt more difficulty in 'financial problem/role difficulty, on the other hand, the former felt difficulty in 'depression'. Hereafter, the additional study about the factor relating to these attitude and needs of the bereaved relating to memorial service will be necessary.

  • PDF

Development of Standard Process for Private Information Protection of Medical Imaging Issuance (개인정보 보호를 위한 의료영상 발급 표준 업무절차 개발연구)

  • Park, Bum-Jin;Yoo, Beong-Gyu;Lee, Jong-Seok;Jeong, Jae-Ho;Son, Gi-Gyeong;Kang, Hee-Doo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.335-341
    • /
    • 2009
  • Purpose : The medical imaging issuance is changed from conventional film method to Digital Compact Disk solution because of development on IT technology. However other medical record department's are undergoing identification check through and through whereas medical imaging department cannot afford to do that. So, we examine present applicant's recognition of private intelligence safeguard, and medical imaging issuance condition by CD & DVD medium toward various medical facility and then perform comparative analysis associated with domestic and foreign law & recommendation, lastly suggest standard for medical imaging issuance and process relate with internal environment. Materials and methods : First, we surveyed issuance process & required documents when situation of medical image issuance in the metropolitan medical facility by wire telephone between 2008.6.1$\sim$2008.7.1. in accordance with the medical law Article 21$\sim$clause 2, suggested standard through applicant's required documents occasionally - (1) in the event of oneself $\rightarrow$ verifying identification, (2) in the event of family $\rightarrow$ verifying applicant identification & family relations document (health insurance card, attested copy, and so on), (3) third person or representative $\rightarrow$ verifying applicant identification & letter of attorney & certificate of one's seal impression. Second, also checked required documents of applicant in accordance with upper standard when situation of medical image issuance in Kyung-hee university medical center during 3 month 2008.5.1$\sim$2008.7.31. Third, developed a work process by triangular position of issuance procedure for situation when verifying required documents & management of unpreparedness. Result : Look all over the our manufactured output in the hospital - satisfy the all conditions $\rightarrow$ 4 place(12%), possibly request everyone $\rightarrow$ 4 place(12%), and apply in the clinic section $\rightarrow$ 9 place(27%) that does not medical imaging issuance office, so we don't know about required documents condition. and look into whether meet or not the applicant's required documents on upper 3month survey - satisfy the all conditions $\rightarrow$ 629 case(49%), prepare a one part $\rightarrow$ 416 case(33%), insufficiency of all document $\rightarrow$ 226case(18%). On the authority of upper research result, we are establishing the service model mapping for objective reception when image export situation through triangular position of issuance procedure and reduce of friction with patient and promote the patient convenience. Conclusion : The PACS is classified under medical machinery that mean indicates about higher importance of medical information therefore medical information administrator's who already received professional education & mind, are performer about issuance process only and also have to provide under ID checking process exhaustively.

  • PDF

Surgical Treatment for Carotid Artery Stenosis (경동맥 협착증의 수술적 치료)

  • Kim, Dae-Hyun;Yi, In-Ho;Youn, Hyo-Chul;Kim, Bum-Shik;Cho, Kyu-Seok;Kim, Soo-Cheol;Hwang, Eun-Gu;Park, Joo-Chul
    • Journal of Chest Surgery
    • /
    • v.39 no.11 s.268
    • /
    • pp.815-821
    • /
    • 2006
  • Background: Carotid endarterectomy is an effective treatment modality in patients with severe carotid artery stenosis, but it may result in serious postoperative complications, We analyzed the results of the carotid endarterectomy performed in our institution to reduce the complications related to the card endarterectomy. Material and Method: We analyzed retrospectively the medical records of 74 patients(76 cases) who underwent carotid endarterectomy for carotid artery stenosis by a single surgeon from February 1996 to July 2004. Result: There were 64 men and 10 women. The mean age of the patients was 63.6 years old. Carotid endarterectomy only was performed in 63 cases, carotid endarterectomy with patch angioplasty in 8 cases, and carotid endarterectomy with segmental resection of internal carotid artery and end to end anastomosis in 5 cases. Intra-arterial shunt was used in 29 cases. The mean back pressures of internal carotid arteries checked after clamping common carotid arteries and external carotid arteries were $23.48{\pm}10.04$ mmHg in 25 cases with changes in electroencephalography(group A) and $47.16{\pm}16.04$ mmHg in 51 cases without changes in electroencephalography(group B). There was no statistical difference in the mean back pressure of internal carotid arteries between two groups(p=0.095), but the back pressures of internal carotid arteries of all patients with changes in electroencephalography were under 40 mmHg. When there was no ischemic change of electroencephalography after clamping common carotid artery and external carotid artery, we did not make use of intra-arterial shunt regardless of the back pressure of internal carotid artery. Operative complications were transient hypoglossal nerve palsy in four cases, cerebral hemorrhage occurred at previous cerebral infarction site in two cases, mild cerebral infarction in one case, hematoma due to anastomosis site bleeding in one case, and upper airway obstruction due to laryngeal edema probably caused by excessive retraction during operation in two cases. One patient expired due to cerebral hemorrhage occurring at previous cerebral infarction site. Conclusion: Carotid endarterectomy is a safe operative procedure showing low operative mortality. We suggest that intra-arterial shunt usage should be decided according to the ischemic change of electroercephalography regardless of the back pressure of internal carotid artery. Excessive retraction during operation should be avoided to prevent upper alway obstruction due to laryngeal edema and if upper airway obstruction is suspected, prompt management is essential.

The Comparative Analysis of External Dose Reconstruction in EPID and Internal Dose Measurement Using Monte Carlo Simulation (몬테 카를로 전산모사를 통한 EPID의 외부적 선량 재구성과 내부 선량 계측과의 비교 및 분석)

  • Jung, Joo-Young;Yoon, Do-Kun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.253-258
    • /
    • 2013
  • The purpose of this study is to evaluate and analyze the relationship between the external radiation dose reconstruction which is transmitted from the patient who receives radiation treatment through electronic portal imaging device (EPID) and the internal dose derived from the Monte Carlo simulation. As a comparative analysis of the two cases, it is performed to provide a basic indicator for similar studies. The geometric information of the experiment and that of the radiation source were entered into Monte Carlo n-particle (MCNPX) which is the computer simulation tool and to derive the EPID images, a tally card in MCNPX was used for visualizing and the imaging of the dose information. We set to source to surface distance (SSD) 100 cm for internal measurement and EPID. And the water phantom was set to be 100 cm of the source to surface distance (SSD) for the internal measurement and EPID was set to 90 cm of SSD which is 10 cm below. The internal dose was collected from the water phantom by using mesh tally function in MCNPX, accumulated dose data was acquired by four-portal beam exposures. At the same time, after getting the dose which had been passed through water phantom, dose reconstruction was performed using back-projection method. In order to analyze about two cases, we compared the penetrated dose by calibration of itself with the absorbed one. We also evaluated the reconstructed dose using EPID and partially accumulated (overlapped) dose in water phantom by four-portal beam exposures. The sum dose data of two cases were calculated as each 3.4580 MeV/g (absorbed dose in water) and 3.4354 MeV/g (EPID reconstruction). The result of sum dose match from two cases shows good agreement with 0.6536% dose error.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF