• 제목/요약/키워드: Patient bed

검색결과 377건 처리시간 0.023초

A Study on Fall Prevention System in Patient Bed

  • Cho, Youngseok
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권1호
    • /
    • pp.101-106
    • /
    • 2019
  • In this paper, we investigate the patient fall prevention system to prevent the patient from falling out of the bed unintentionally on the bed of the bed. Patients stay in bed for many hours of hospitalization. During the hospitalization period, patients have low controllability of the body, as compared with normal persons, and fall due to intentional movements, resulting in a fall of the patient, can be a fatal threat to the patient. Therefore, an efficient fall prevention system is required. In this paper, the distance map to the patient is generated by the distance measuring sensor on the bed of the patient, and the risk is determined by estimating the position of the patient based on the distance map. As a result, when the distance map of the dangerous area is 150 mm or more, it is determined to be dangerous, and good results are obtained.

1인실과 다인실 입원 병상 이용에 관한 병상 선택 요인과 환자 만족도 분석 (Use of Single Bedrooms versus Multiple Bedrooms: Selection Factors and Comparison of Patient Satisfaction)

  • 이근찬
    • 한국병원경영학회지
    • /
    • 제26권3호
    • /
    • pp.68-83
    • /
    • 2021
  • Background: It is widely acknowledged that single bedrooms have many potential advantages compared to multiple bedrooms. However, Korea has a reimbursement system that patients have to pay the additional fee if they will use single bedroom or pay-bed (1-3 bedroom). There is little research on patients' bed selection and relationship between patient satisfaction and bed type in the Korean setting. Methods: Using the 2017 Korea Health Panel (KHP) Survey data, we modified bed type by two dichotomous variables: single bedroom vs. multiple bedroom (2+ bedrooms) and pay-bed (1-3 bedroom) vs. reimbursed bed (4+ bedroom). Multivariate logistic regression is performed to determine the factors affecting the patient's choice of room types. Multivariate regression analysis was conducted to examine how hospital room types are affecting patient satisfaction. Results: Single room and pay-bed (1-3 bedroom) use was influenced by patient age (19- years old), male, a person at work, hospitalizing in a clinic, and birth. After controlling variables of the behavioral model of medical utilization, the association between patient satisfaction and use of single bedroom & pay-bed (1-3 bedroom). Cause of hospitalization, major treatment, and recognition of unnecessary care are statistically significant variables on patient satisfaction. Conclusion: Although the single room is about the standard for newly built hospitals in western countries, it remains unclear that single room or pay-bed (1-3 bedroom) has positive effects on patient's outcomes and satisfaction. In this empirical study, the difference in patient satisfaction by bedroom type was not noticeable. In terms of bed management by hospital staff, securing patient credibility in hospital care is an important task. Patients' perception of whether medical staffs have encouraged unnecessary treatment or tests has a significant impact on patient's satisfaction.

중환자실 병상주변공간의 면적과 간격에 관한 연구 (A Study on the Area and Clearances around Patient Bed Space in Intensive Care Unit)

  • 이현진;권순정
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권3호
    • /
    • pp.47-55
    • /
    • 2019
  • Purpose: This study tries to propose the dimensions and area related to patient bed and surroundings in ICU considering nurses' observation and medical care. Methods: Literature survey, 11 Case studies, some Interviews with nurses and measuring of medical equipments' dimension in ICU have been mobilized in order to deepen the ICU bed area standards. Results: 0.3m clearance between head wall and patient bed is necessary for emergency cases. The minimum distance at the foot of the bed should not be less than 0.9m for EMR cart and medical tray. The clear floor area of one bed and surroundings in open ward is $10.2m^2(3m{\times}3.4m)$. In a single-bed patient room, the minimum clear floor area is $16.0m^2(4m{\times}4m)$. Considering the control of cross infection in ICU, Single bed patient room is recommended. Implications: The result of this study can be applied to the design of ICU and legislation of ICU standard.

운동 분석을 통한 욕창 방지용 침대 기구의 개선 (Improvement of the Medical Bed for Preventing Decubitus Ulcer through Motion Analysis)

  • 심창섭;심재경;권진욱;임득재
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.713-718
    • /
    • 2003
  • Decubitus ulcer is a pressure-induced ulceration of the skin occurring in persons confined to bed for long periods of time. In order to prevent decubitus ulcer, the medical bed mechanism to minimize pressure, friction, and shear forces acting between bed and patient had been developed. Air mattress also can be effective for reducing pressure over bony prominence. In this study, motion analysis was performed to examine whether this bed mechanism functioned properly in case of using air mattress, which was much thicker than common hospital mattress. We found that the patient on the air mattress above the medical bed for preventing decubitus ulcer slipped upward and downward excessively as the general motored-bed. New bed mechanisms were synthesized kinematically using simple 4-bar and 6-bar linkages so as to reduce sliding between the bed and the patient on the air mattress for preventing decubitus ulcer.

  • PDF

지역병상수급계획 실효성 제고를 위한 수요공급 현황 분석 (Analysis of Demand-Supply Status for Improving the Effectiveness of Plans for Supply and Demand of Reginal Patient Beds)

  • 양정민;김재현
    • 보건행정학회지
    • /
    • 제33권4호
    • /
    • pp.411-420
    • /
    • 2023
  • Background: The purpose of this study was to analyze the demand and supply status of patient beds by type of medical institution, categorized into 70 clinical privilege, in order to understand the regional bed supply situation. Methods: Utilizing the 70 clinical privilege defined by the Ministry of Health and Welfare, we calculated bed demand and supply quantities from 2019 to 2021 using data from Statistics Korea and the Health Insurance Statistical Yearbook. The bed demand calculation formula was based on the detailed guidelines for the medical sector by the Korea Development Institute and the 3rd edition of bed supply basic policies announced by the Ministry of Health and Welfare. Additionally, to mitigate distorted bed supply situations caused by factors such as regional levels and patient outflows, we classified bed supply types using the population decrease index indicator published by the Ministry of Public Administration and Security. Results: Among the 70 clinical privilege, it was analyzed that a relatively balanced bed supply situation exists overall, irrespective of the type of healthcare institution. However, in medical institutions at or above the level of hospitals, regions with bed supply ratios exceeding 20% compared to demand, particularly in institutions at or above the level of general hospitals, showed a relatively high rate of demand diversion. Conclusion: We have identified the bed supply types in the 70 clinical privilege in South Korea. Based on the results of this study, we emphasize the need for bed supply policies that consider regional characteristics. It is expected that this research can serve as fundamental data for future efforts aimed at managing or rectifying bed supply imbalances on a regional basis.

병원의 다인병실 환경개선에 관한 연구 (A Study on the Environmental Improvement of Multi-bed rooms in Hospital)

  • 유영민
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제11권1호
    • /
    • pp.7-14
    • /
    • 2005
  • The existing six-bed patient rooms, general type of multiple-bed rooms in Korea causes many problems for the amenity of patients. We should reconsider their inconvenience carefully and try to provide the right to keep their privacy and enjoy amenity. The number of patients of multi-bed rooms is very critical point to improve the environmental condition of the patient rooms. So This paper aims to provide the possibilities of four-bed rooms through the comparison and analysis of six and four-bed room for planning and design.

  • PDF

Occupancy 센서와 도플러 Radar를 이용한 침상 모니터링 시스템 (Bed Side Monitoring System using Occupancy Sensor and Doppler Radar)

  • 강병욱;유선국
    • 한국멀티미디어학회논문지
    • /
    • 제21권3호
    • /
    • pp.382-390
    • /
    • 2018
  • A major accident occurring on the bed is falls that occur during at times when the care of nurses or protectors is inadequate, which is fatal to patients or the elderly. In particular, Enuresis or sleepiness caused by sleep apnea increases the risk of falls. Therefore, it is very important to detect falls and sleep apnea of patients without infringing privacy in the bed to patient's safety and accident prevention. In this paper, we reviewed the technologies developed for bed monitoring and implemented a non-intrusive monitoring system. The Occupancy Sensor allows the temperature of the bed and surrounding area to be extracted to enable track of the patient's motion. The Doppler Radar detects the patient's movements at normal times and the respiration state when patients have no movement during sleeping. It is specially designed for real-time monitoring of falling and respiration during sleeping through contactless multi-sensing while solving patient's privacy problems.

종합병원 다인병실의 치유환경 개선을 위한 건축 계획적 연구 (A Study on the Architectural Planning for Improvement of the Healing Environment in Multi-bed Room of General Hospitals)

  • 김용우;양내원
    • 한국실내디자인학회논문집
    • /
    • 제36호
    • /
    • pp.76-83
    • /
    • 2003
  • The purpose of this study is to know how to improve environment of multi-bed room by investigating and analysing factors influencing to patients. 1 measured stress and satisfaction degrees about patient room for 4ㆍ5ㆍ6ㆍ7 men of domestic general hospital wards. The results of research show that patients of 4 bed room appeared the fewest stress and highest satisfaction degree among patients of other room styles. The patients positioned between two beds can give us more stress and fewer satisfaction than others. These results have proven that 4 bed room patients are offering comfortable environment than any other room types as a healing environment. When patient room area are more than 7.3$M^2$ per 1 person, bed interval space is more than 120cm, there is curtain between bed, transit space such as a toilet were established in patient room, patients' satisfaction appeared high.

와상환자복 하의 디자인 개발 (A Design Development of Hospitalized Patients' Pants for Bed-ridden Patients)

  • 박혜원;류은정
    • 한국의류학회지
    • /
    • 제32권9호
    • /
    • pp.1418-1426
    • /
    • 2008
  • This study aims to develop the functional pants for the hospitalized bed-ridden patient. The procedure of this study consisted of three parts. First, the interview survey of nursing care givers was conducted to inquire into the conditions of bed-ridden patients' clothing. Second, the bed-ridden patients' pants design and sample making were accompanied. Then, the wearing tests and design development were completed. The results are as follows; The conditions of bed-ridden patients' clothing were the convenience of clothing change, the partial opening for diaper change and medical treatment and the ventilation for bedsore prevention. The design development of the bed ridden patients' pants was accomplished which had the side seams with two way opening zippers, the wraparound pattern of abdomen and the opening under crotch applied the advantage of korean traditional underwear sokkot. The samples' wearing tests were performed three times and those subjects were the hospitalized bed-ridden patients. Consequently, we suggested the appropriate hospitalized patients' pants for bed-ridden patient.

A Study on the Development of Predictive Model for Patient Visibility in Korean Intensive Care Units (ICUs) - Focused on "Corridor or Continental" type units

  • 울라 우바이드;박재승
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제22권3호
    • /
    • pp.27-34
    • /
    • 2016
  • Purpose: The purpose of this paper is to develop a predictive model for patient visibility in Korean ICUs (corridor or continental type). Methods: The measures of static visibility were used to quantify the patient visibility (upper third part of the patient bed) from the nurse station. The measure of space programme and area distribution (patient zone percentage, staff zone percentage and departmental gross square meter per patient bed) were calculated by using AutoCAD and MS Excel programs. Regression analysis was conducted for visibility as dependant variable with independent variables of patient area percentage, staff area percentage as well as departmental gross square meter per bed by using IBM SPSS. Results: (1) Average patient visibility and percentage of patient area in ICU shows a strong negative correlation ($r^2$=0.66), p=0.01. (2) Patient visibility in Korean ICU (corridor or continental type) can be calculated as below with the given conditions: Y= $-1.449(X)+124.3{\pm}6$, Y is the total visibility of the ICU (corridor or continental type) and X is the percentage of patient area in the unit. Conditions:1. Given that the unit has a mixed programme of open bed and closed patient rooms and 2. The unit have a minimum of 20% patient rooms. Implications: This study may contribute to the visibility analysis of existing and future ICU design (corridor or continental type) in Korea to achieve maximum patient visibility and reduced patient mortality.