• Title/Summary/Keyword: Patch

Search Result 3,490, Processing Time 0.028 seconds

10.525 GHz Band Broadband Inset-fed Microstrip Patch Antenna (10.525 GHz 대역 광대역 인셋-급전 마이크로스트립 패치 안테나)

  • Junho Yeo;Jong-Ig Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.1
    • /
    • pp.136-141
    • /
    • 2024
  • In this paper, a broadband inset-fed microstrip patch antenna operating at 10.525 GHz band was proposed. The proposed broadband inset-fed microstrip patch antenna consists of three narrow rectangular patches. At the center of the center patch, two symmetrical side patches were connected by a strip conductor and were arranged with their centers shifted in a perpendicular direction with respect to the center patch. For performance comparison, a conventional inset-fed square microstrip patch antenna was designed. Experiment results show that the frequency band of the measured input reflection coefficient with a voltage standing wave ratio less than 2 for the broadband inset-fed microstrip patch antenna was 10.036-11.051 GHz (9.63%), whereas that for the conventional inset-fed rectangular microstrip patch antenna was 10.306-10.772 GHz (4.42%). Therefore, the input reflection coefficient frequency bandwidth of the fabricated broadband inset-fed microstrip patch antenna was increased by 2.18 times, compared to the conventional inset-fed square microstrip patch antenna.

Landscape ecological analysis of urban parks -analysis of index of patch shape and the dispersion of patches- (도시공원의 경관생태학적 분석-패취의 형태지수와 분산도 분석을 중심으로-)

  • 김명수;안동만
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.23 no.4
    • /
    • pp.12-19
    • /
    • 1996
  • Urban parks, as remnant patches, of two older cities and two new towns can be analyzed by a landscape ecological approach. The index of patch shape, the dispersion of patches, the mean edge length, and the mean patch size of parks of each city are ocmpared. The findings of this study are as follows : 1) The mean edge length of urban parks of older cities is longer than that of new towns : Seoul>Suwon>Bundang>Ansan. 2) The mean patch size of urban parks in Seoul is much greater than those of other cities : Seoul> Ansan>Suwon>Bundang. 3) The index of patch shape of urban parks of older cities is greater than that of new towns : Seoul>Suwon>BundangAnsan. 4) The dispersion of patches is in the order of Bundang >Ansan>Seoul>Suwon. The new towns have relatively even distributions of urban parks than older cities. Further research is required to find out the relationship between the index of patch shape and patch interior dynamics.

  • PDF

Effect of a Microbial Product on the Control of Soilborne Diseases of Turfgrasses (미생물제에 의한 잔디의 토양전염병 방제 효과)

  • 박규진;김영호;박은경;김동성
    • Plant Disease and Agriculture
    • /
    • v.1 no.1
    • /
    • pp.19-29
    • /
    • 1995
  • A microbial product composed of three antagonistic fungal isolates (Aspergillus sp., Penicillium sp. and Trichoderma sp.) and three bacterial isolates (Arthrobacter sp., Bacillus sp., and Pseudomonas sp.) was tested for the control of Pythium blight caused by Pythium sp., brown patch by Rhizoctonia solani (anastomosis group(AG) 1-1) and large patch by R. solani (AG 2-2) of turfgrasses. Cultures of the antagonistic fungi and bacteria varied in the effectiveness in reducing disease severity of Pytium blight and brown patch on bentgrass. The antagonistic fungal and bacterial isolates were mixed and cultured at 20-$25^{\circ}C$ for 3 days in a growth medium, and the diluted solution of the microbial culture was applied under the field conditions after inoculation of the above turfgrass pathogens. The treated turfgrass was incubated at 28$^{\circ}C$ in a growth chamber. In this experiment, Pythium blight was almost completely controlled and brown patch was slightly decreased by the microbial product, while no control was observed in large patch of zoysiagrass. In zoysiagrass treated with the microbial culture, thatch accumulation was notably reduced.

  • PDF

Central Anticholinergic Syndrome by the Use of Scopolamine Patch -A case report- (수술후 통증관리 환자에서 Scopolamine Patch에 의해 발생한 중추항콜린성증후군 -증례 보고-)

  • Cho, Chong-Duk
    • The Korean Journal of Pain
    • /
    • v.12 no.2
    • /
    • pp.250-252
    • /
    • 1999
  • A 77-year-old male patient was admitted to the hospital with acute appendicitis and underwent emergency appendectomy under inhalation anesthesia without any complications. After the operation, the patient was placed on epidural analgesia with the mixture of fentanyl-bupivacaine and scopolamine patch for nausea and vomiting. The patient experienced central anticholinergic syndrome (CAS) with hallucination, confusion, somnolence, dysarthria and delirium at 20 hours after patch placement and recovered from all symptoms of CAS in 24 hours after the removal of the patch. The CAS occurs when central cholinergic sites are occupied by specific drugs and also as a result of an insufficient release of acetylcholine. The diagnosis of CAS is often determined by a process of exclusion and not actually made until a positive therapeutic response to physostigmine, a centrally active anticholiesterase agent, has taken place. Treatment of CAS includes prompt removal of the patch, cleansing of the area, and physostigmine administration. The scopolamine patch should be used with extreme caution in elderly patient.

  • PDF

Efficacy of Hydrogel Patch in Wound Rat Model (동물모델을 이용한 Hydrogel Patch의 상처치유개선 능력 평가)

  • Oh, Seung-Seok;Kim, Chul-Jun;Kim, Hee-Sook;Shin, Young-Hee
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.1
    • /
    • pp.55-58
    • /
    • 2009
  • Sodium polyacrylate based hydrogel patch was prepared and its wound healing efficacy in comparison with control groups was evaluated in thermal burn wound ($200^{\circ}C$, 10 sec burn) and excision wound rat model. Cytotoxicity of gamma irradiated (25 kGy) hydrogel patch was investigated in human fibroblasts and showed no significant cytotoxicity. Wound closure rates (H50%) in hydrogel patch group and BAND-$AID^{(R)}$ treated group were faster than that of control group (uncovered open wound). Hydrogel patch showed an enhancement in wound healing process.

New optimization method of patch shape to improve the effectiveness of cracked plates repair

  • Bouchiba, Mohamed S.;Serier, Boualem
    • Structural Engineering and Mechanics
    • /
    • v.58 no.2
    • /
    • pp.301-326
    • /
    • 2016
  • An optimization method of patch shape was developed in this study, in order to improve repair of cracked plates. It aimed to minimize three objectives: stress intensity factor, patch volume and shear stresses in the adhesive film. The choice of these objectives ensures improving crack repair, gaining mass and enhancing the adhesion durability between the fractured plate and the composite patch. This was a multi-objective optimization combined with Finite elements calculations to find out the best distribution of patch height with respect to its width. The implementation of the method identified families of optimal shapes with specific geometric features around the crack tip and at the horizontal end of the patch. Considerable mass gain was achieved while improving the repair efficiency and keeping the adhesive shear stress at low levels.

Estimation for Input Impedance of Microstrip Patch Antenna corresponding to Cutting Shape (마이크로스트립 패치 절단 모양에 따른 입력 임피던스 평가)

  • Kim, Tae Yong;Lee, Jong-Ig
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.480-481
    • /
    • 2015
  • General microstrip patch antenna has small bandwidth. If corner of a patch antenna is properly cutted to be triangular shape, then input impedance of patch antenna should be varied. Using this characteristic wideband patch antenna can be implemented. In this paper, wideband microstrip patch antenna operating in 2.4GHz ISM band is investigated through tracking variation of input impedance corresponding to cutting shape of patch antenna.

  • PDF

Analysis of Design Error in Windows Update and Automatic Updates, and the Solutions (Windows Update 및 Automatic Updates의 설계 오류 분석 및 해결 방안)

  • Kim, Yun-Ju;Yun, Young-Tae;Kang, Sung-Moon
    • Convergence Security Journal
    • /
    • v.6 no.3
    • /
    • pp.107-115
    • /
    • 2006
  • It discovered a design error from the module to search required installing security patch of Windows Update and Automatic Updates that Microsoft supports it to install security patch easily and quickly. It explains and tests security patch-disguise attack by this error. Security patch-disguise attack is to maintains a vulnerability and to be not searched the security patch simultaneously. Also it composes an attack scenario. Is like that, it proposes the method which solves an design error of the module to search required installing security patch.

  • PDF

DRF-based Object Detection Using the Object Adaptive Patch in the Satellite Imagery

  • Choi, Hyoung-Min;Lee, Kyoung-Mu;Lee, Sang-Uk
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.85-88
    • /
    • 2009
  • In this paper, we propose a DRF-based object detection method using the object adaptive patch in the satellite imagery. It is a Discriminative Random Fields (DRF) based work, so the detection is done by labeling to the possible patches in the image. For the feature information of each patch, we use the multi-scale and object adaptive patch and its texton histogram, instead of using the single scale and fixed grid patch. So, we can include contextual layout of texture information around the object. To make object adaptive patch, we use "superpixel lattice" scheme. As a result, each group of labeled patches represents the object or object's presence region. In the experiment, we compare the detection result with a fixed grid scheme and shows our result is more close to the object shape.

  • PDF

An Experimental Study on Fatigue Life of Brace Mounting Joint (브레이스 마운팅 결합부의 피로 수명에 관한 실험적 연구)

  • 김동우
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.3
    • /
    • pp.104-109
    • /
    • 1998
  • This document is a experimental study on fatigue life of brace mounting weld joint. A brace is used to put sub-frame together on the main frame with high strength bolts. It has low fatigue life so a patch is in need for improving a fatigue characteristics of welded joint in brace mounting This paper presents the most pertinent patch size for truck. For this, a critical stress is computed at the point of fatigue crack occurred on truck frame by finite Element Analysis. Using by this critical stress. Designers are able to determin whether fatigue crack is occurred and are able to select a pertinent patch type. And then, with a selected patch type, structural joint stiffness was estimated to compare to the conventional and other patch type or brace mounting Finally, fatigue test were performed to prove a suitability of selected prototype compare with the conventional and other patch type or brace mounting.