• Title/Summary/Keyword: Paste Electrode

Search Result 255, Processing Time 0.022 seconds

Characteristics of Capacitive Deionization Process using Carbon Aerogel Composite Electrodes (탄소에어로젤 복합전극의 전기용량적 탈이온 공정 특성)

  • Lee, Gi-Taek;Cho, Won-Il;Cho, Byung-Won
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.2
    • /
    • pp.77-81
    • /
    • 2005
  • Porous-composite electrodes have been developed using silica gel, which reduce carbon aerogel usage with high cost. Silica gel powder was added to the carbon aerogel to simplify the manufacturing procedure and to increase the wet-ability, the mechanical strength and the CDI efficiency. Porous composite electrodes composed of carbon aerogel and silica gel powder were prepared by paste rolling method. Carbon aerosol composite electrodes with $10\times10cm^2$ are placed face to face between spacers, and assembled the four-stage series cells for CDI process. Each stage is composed of 45 cells. Four-stage series cells (flow through cells) for CDI process are put in continuous-system reactor containing 1,000ml-NaCl solution bath of 1,000 ppm. The four-stage series cells with carbon aerogel electrodes are charged at 1.2V and are discharged at 0.001V, and then read the current. Conclusively, removal efficiencies of ions using the four-stage series cells composed of carbon aerogel composite electrodes show good removal efficiency of $99\%$ respectively.

Electrochemical Detection of Hydroxychloroquine Sulphate Drug using CuO/GO Nanocomposite Modified Carbon Paste Electrode and its Photocatalytic Degradation

  • G. S. Shaila;Dinesh Patil;Naeemakhtar Momin;J. Manjanna
    • Journal of the Korean Electrochemical Society
    • /
    • v.27 no.1
    • /
    • pp.15-31
    • /
    • 2024
  • The antimalarial drug hydroxychloroquine sulphate (HCQ) has taken much attention during the first COVID-19 pandemic phase for the treatment of severe acute respiratory infection (SARI) patients. Hence it is interest to study the electrochemical properties and photocatalytic degradation of the HCQ drug. Copper oxide (CuO) nanoparticles, graphene oxide (GO) and CuO/GO NC (nanocomposite) modified carbon paste electrodes (MCPE) are used for the detection of HCQ in an aqueous medium. Electrochemical behaviour of HCQ (20 μM) was observed using CuO/MCPE, GO/MCPE and CuO/GO NC/MCPE in 0.1 M phosphate buffer at pH 7 with a scan rate of 20 to 120 mV s-1 by cyclic voltammetry (CV). Differential pulse voltammetry (DPV) of HCQ was performed for 0.6 to 16 μM HCQ. The CuO/GO NC/MCPE showed a reasonably good sensitivity of 0.33 to 0.44 μA μM cm-2 with LOD of 69 to 92 nM for HCQ. Furthermore, the CuO/GO NC was used as a catalyst for the photodegradation of HCQ by monitoring its UV-Vis absorption spectra. About 98% was degraded in about 34 min under visible light and after 4 cycles it was 87%. The improved photocatalytic activity may be attributed to decrease in bandgap energy and enhanced ability for the electrons to migrate. Thus, CuO/GO NC showed good results for both sensing and degradation applications as well as reproducibility.

Dye-sensitized Solar Cells Utilizing Core/Shell Structure Nanoparticle Fabrication and Deposition Process (코어/쉘 구조의 나노입자 제조 및 증착 공정을 활용한 염료감응 태양전지)

  • Jeong, Hongin;Yoo, Jhongryul;Park, Sungho
    • Korean Chemical Engineering Research
    • /
    • v.57 no.1
    • /
    • pp.111-117
    • /
    • 2019
  • This study proposed the fabrication and deposition of high purity crystalline $core-TiO_2/shell-Al_2O_3$ nanoparticles. Morphological properties of $core-TiO_2$ and coated $shell-Al_2O_3$ were confirmed by transmission electron microscope (TEM) and transmission electron microscope - energy dispersive spectroscopy (TEM-EDS). The electrical properties of the prepared $core-TiO_2/shell-Al_2O_3$ nanoparticles were evaluated by applying them to a working electrode of a Dye-Sensitized Solar Cell (DSSC). The particle size, growth rate and the main crystal structure of $core-TiO_2$ were analyzed through dynamic light scattering system (DLS), scanning electron microscope (SEM) and X-ray diffraction (XRD). The $core-TiO_2$, which has a particle size of 17.1 nm, a thin film thickness of $20.1{\mu}m$ and a main crystal structure of anatase, shows higher electrical efficiency than the conventional paste-based dye-sensitized solar cell (DSSC). In addition, the energy conversion efficiency (6.28%) of the dye-sensitized solar cell (DSSC) using the $core-TiO_2/shell-Al_2O_3$ nanoparticles selectively controlled to the working electrode is 26.1% higher than the energy conversion efficiency (4.99%) of the dye-sensitized solar cell (DSSC) using the conventional paste method.

Low Cost and High Sensitivity Flexible Pressure Sensor Based on Graphite Paste through Lamination after O2 Plasma Surface Treatment Process (O2 플라즈마 표면 처리 공정 후 라미네이션 공정으로 제작된 흑연 페이스트 기반의 저비용 및 고감도 유연 압력 센서)

  • Nam, Hyun Jin;Kang, Cheol;Lee, Seung-Woo;Kim, Sun Woo;Park, Se-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.4
    • /
    • pp.21-27
    • /
    • 2022
  • Flexible pressure sensor was developed using low-cost conductive graphite as printed electronics. Flexible pressure sensors are attracting attention as materials to be used in future industries such as medical, games, and AI. As a result of evaluating various electromechanical properties of the printed electrode for flexible pressure sensors, it showed a constant resistance change rate in a maximum tensile rate of 20%, 30° tension/bending, and a simple pulse test. A more appropriate matrix pattern was designed by simulating the electrodes for which this verification was completed. Utilizing the Serpentine pattern, we utilized a process that allows simultaneous fabrication and encapsulation of the matrix pattern. One side of the printed graphite electrode was O2 plasma surface treated to increase adhesive strength, rotated 90 times, and two electrodes were made into one through a lamination process. As a result of pasting the matrix pattern prepared in this way to the wrist pulse position of the human body and proceeding with the actual measurement, a constant rate of resistance change was shown regardless of gender.

Use of Carbon Nanotube Electrode and Squarewave Anodic Stripping Voltammetry for the Detection of Lead Heavy Metal (납 중금속 검출을 위한 탄소나노튜브 전극 및 네모파 양극 벗김 전압전류법 이용)

  • Choi, Changkun;Seok, Jonghyuk;Kwon, Yongchai
    • Applied Chemistry for Engineering
    • /
    • v.23 no.5
    • /
    • pp.505-509
    • /
    • 2012
  • In this study, we investigate the use of new carbon nanotube paste electrode (CNPE) for promoting the detection of lead (Pb) heavy metal in the a drinkable water, which negatively affects human brain and nerve system. For the evaluations, CNPE is served as a working electrode, while sensitivity and limit of detection (LOD) of Pb are measured in DI and tap water based electrolytes using squarewave anodic stripping voltammetry (SWASV). As a result of that, in the 25~150 ppb range of $Pb^{2+}$ ions, its sensitivity and calculated LOD are $12.85\;{\mu}A/{\mu}M$ and 26 ppb in DI water based 0.1 M $H_{2}SO_{4}$ electrolyte while they are $10.36\;{\mu}A/{\mu}M$ and 38 ppb electrolytes respectively. In addition, experimentally measured LOD values of Pb are 4 ppb and 10 ppb in the two water electrolytes. The stripping of $Pb^{2+}$ ion is also controlled by surface reaction. Our experimental data are then compared with those of other already published references. With the comparison, it is proved that our electrode outperforms other electrodes in terms of the sensitivity and LOD of trace Pb metal.

DSSC Efficiency Characteristics by Annealing Temperature and Thickness of Electrodes (전극의 두께와 소성 온도에 따른 DSSC의 효율 특성)

  • Hwang, Ki-Seob;Ha, Ki-Ryong
    • Applied Chemistry for Engineering
    • /
    • v.21 no.4
    • /
    • pp.405-410
    • /
    • 2010
  • The photovoltaic performance of DSSCs fabricated with different electrode thickness and different annealing temperature with the P25 $TiO_2$ and the Dyesol $TiO_2$ was measured. Thickness change of $TiO_2$ electrodes was measured using cross-sectional FE-SEM before and after annealing. Photovoltaic efficiencies of DSSCs were also measured by changing annealing temperature of platinum (Pt) paste on the counter electrode. Photovoltaic performances of DSSCs made with one layer of P25 (${\sim}20.4\;{\mu}m$) and one layer of Dyesol $TiO_2$ (${\sim}9.1\;{\mu}m$) annealed at $500^{\circ}C$ for 30 min. showed highest efficiencies of 3.8% and 5.8%, respectively.

Electrochemical Immobilization of Osmium Complex onto the Carbon Nano-Tube Electrodes and its Application for Glucose sensor (전기화학적인 방법을 이용한 탄소나노튜브 전극상의 오스뮴 착물의 고정화 및 혈당센서에 관한 응용)

  • Choi, Young-Bong;Jeon, Won-Yong;Kim, Hyug-Han
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.1
    • /
    • pp.50-56
    • /
    • 2010
  • The multi-wall carbon nano-tube composite mixed with carbon paste electrode presented more sensitive and selective amperometric signals in the oxidation of glucose than general screen-printed carbon electrodes(SPCEs). Redox mediators to transport electrodes from enzyme to electrodes are very important part in the biosensor. A novel osmium redox complex was synthesized by the coordinating pyridine group containing primary amines which were electrochemically immobilized onto the MWCNT-SPCEs surface. Electrochemical studies of osmium complexes were investigated by cyclic voltammetry, chronoamperometry. The surface coverage of osmium complexes on the modified carbon nano-tube electrodes were significantly increased at 100 time (${\tau}_0=2.0\;{\times}\;10^{-9}\;mole/cm^2$) compared to that of the unmodified carbon electrodes. It's practical application of the glucose biosensor demonstrated that it shows good linear response to the glucose concentration in the range of 0-10 mM.

Fabrication and Characterization of Carbon Nanotube Field Emission Display for HD-TV Applications

  • Lee, Chun-Gyoo;Chi, Eung-Joon;Hwang, Sung-Yeon;Lee, Sang-Jo;Lee, Sang-Jin;Yoon, Tae-Ill;Lee, Byong-Gon;Nam, Joong-Woo;Ryu, Mee-Ae;Han, Ho-Su;Jin, Sung-Hwan;Ahn, Sang-Hyuck;Seo, Hyoung-Cheol;Choi, Jong-Sik;Oh, Tae-Sik;Kang, Sung-Kee;Kim, Jong-Min;Kim, Jung-Woo;Park, Young-Jun;Han, In-Taek;Jin, Yong-Wan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.191-192
    • /
    • 2003
  • For the CNT-FED to be cost-effective, many efforts for the lower voltage operation have been made in the under-gate cathode structure. In this study, the effects of the frit proportion in the CNT paste, cathode electrode width, CNT-to-counter electrode gap, and the CNT length in the cathode structure were examined.

  • PDF

Ex Vivo Assay of Trace Nicotine Using a Voltammetric Modified Biosensor

  • Ly, Suw Young;Jang, Myung-Ho;Cha, Jae-Min;Kim, Min-Young;Oh, Hyun-Seok;Jo, Dong-Hyeon;Choi, Seong-Sik
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.40-46
    • /
    • 2012
  • In vivo nicotine is associated with Alzheimer's, Parkinson's and lung cancer. Diagnostic assays of these diseases depend on very low analytical detection limits. In this study, a sensitive analytical method was examined using a voltammetric graphite pencil electrode (GPE) and a modified carbon nanotube paste electrode (CNE). The optimum analytical conditions for both electrodes were compared using square wave anodic stripping voltammetry (SW) and cyclic voltammetry (CV) obtaining 400 sec accumulation time and oxidation peak. Under optimum parameters, the stripping working range of GPE was $5.0-40.0{\mu}g/L$, CNE: 0.1-0.8 and $5-50{\mu}g/L$. Quantification limits were $5.0{\mu}g/L$ for GPE and $0.1{\mu}g/L$ for CNE, while detection limits were $0.6{\mu}g/L$ for GPE and $0.07{\mu}g/L$ for CNE. A standard deviation of $10.0{\mu}g/L$ was observed for 0.064 GPE and 0.095 CNE (n = 12) using 400 sec accumulation time. The results obtained can be applied to non.treated urine and ex vivo biological diagnostics.

Electroanalytical Measurement of TEDA (Triethylenediamine) in the Masks of War

  • Ariani, Zahra;Honarmand, Ebrahim;Mostaanzadeh, Hossein;Motaghedifard, Mohammadhassan;Behpour, Mohsen
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.43-52
    • /
    • 2017
  • In this paper, for the first time, the electroanalytical study of Triethylenediamine, TEDA was done on a typically graphene modified carbon paste electrode (Gr/CPE) in pH=10.5 of phosphate buffer solutions (PBS). The surface morphology of the bare and modified electrodes was characterized by scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The electro-oxidation of TEDA was investigated at the surface of modified electrode. The results revealed that the oxidation peak current of TEDA at the surface of Gr/CPE is 2.70 times than that shown at bare-CPE. A linear calibration plot was observed in the range of 1.0 to 202.0 ppm. In this way, the detection limit was found to be 0.18 ppm. The method was then successfully applied to determination of TEDA in aqueous samples obtained from two kinds of activated carbon from the masks of war. On the other hand, density functional theory (DFT) method at B3LYP/6-311++G** level of theory and a conductor-like Polarizable Continuum Model (CPCM) was used to calculate the $pK_a$ values of TEDA. The energies of lowest unoccupied molecular orbital ($E_{LUMO}$) and highest occupied molecular orbital ($E_{HOMO}$), gap energy (${\Delta}E$) and some thermodynamic parameters such as Gibbs free energy of TEDA and its conjugate acid ($HT^+$) were calculated. The results of calculated $pK_a$ were found to be in good agreement with the experimental values.