• Title/Summary/Keyword: Passive technique

Search Result 441, Processing Time 0.03 seconds

Optimal Design of Hybrid Control System through Inter-Building Connection (빌딩간 연결을 통한 복합제어시스템의 최적설계)

  • Park, Kwan-Soon;Ok, Seung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.81-88
    • /
    • 2017
  • This study deals with the optimal design of a hybrid control system composed of a combination of active control system and passive control system for effective seismic performance improvement of two adjacent structures. The proposed hybrid control system adopts a configuration of installing an active control device in one building and connecting two adjacent structures with a passive control device so that the one-side active control force can be bi-directionally applied to both buildings through the passive connecting devices. In order to derive the optimal performance of the proposed system, the design parameters of the passive and active control systems were searched using the genetic algorithm. Numerical simulations of 10-story and 8-story buildings have been performed to verify the effectiveness of the proposed technique. For the purpose of comparison, the conventional independent control system with two identical active control systems being installed separately for each structure was also optimally designed and its seismic response has been evaluated as well. From the comparative results of the two control systems, it is demonstrated that the proposed hybrid control system requires larger control force for its one-side active control device than the conventional independent control system does for each of both-side active devices, but quite less than the total control force required for both-side devices of the independent control system, while maintaining similar seismic performance. Therefore, the proposed system is more economical and reliable than the conventional independent control system with two identical active devices.

Study on the Short Term Exposure Level (STEL) of the Benzene for the Tank Lorry Truck Drivers during Loading Process

  • Park Doo Yong
    • International Journal of Safety
    • /
    • v.3 no.1
    • /
    • pp.27-31
    • /
    • 2004
  • Some of the petroleum products contain benzene which is well known as a confirmed human carcinogen. For example, gasoline products contain benzene ranging up to several percents by weight. High exposures to the benzene and other organic solvents would be likely to occur during intermittent tasks and or processes rather than continuous jobs such as sampling, repair, inspection, and loading/unloading jobs. The work time for these jobs is various. However, most of work time is very short and the representative time interval is 15 minutes. Thus, it is preferable to do exposure assessment for 15 minute time weighted average which is known as a short time exposure level(STEL) by ACGIH rather than for 8-hours TWA. It is particularly significant to the exposure monitoring for benzene since it has been known that the exposure rate plays an important role to provoke the leukemia. Due to the large variations, a number of processes/tasks, the traditional sampling technique for organic solvents with the use of the charcoal and sampling pumps is not appropriate. Limited number of samples can be obtained due to the shortage of sampling pumps. Passive samplers can eliminate these limitations. However, low sampling rates resulted in collection of small amount of the target analysts in the passive samplers. This is originated the nature of passive samplers. Field applications were made with use of passive samplers to compare with the charcoal tube methods for 15 minutes. Gasoline loading processes to the tank lorry trucks at the loading stations in the petroleum products storage area. Good agreements between the results of passive samplers and those of the charcoal tubes were achieved. However, it was found that special cautions were necessary during the analysis at very low concentration levels.

Quantitative and Qualitative Differences according to the Shoe Type for the Grand Jete Landing in Ballet

  • Yi, Kyung-Ok;Park, Hye-Rhee
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.1
    • /
    • pp.25-29
    • /
    • 2011
  • The purpose of this study was to analyze quantitative and qualitative differences according to shoe type for the grand jete landing in ballet. The subjects for this study were 9 female ballet majors with an average of 12 years of experience. Subjects jumped, performing a front split, and landed on 1 foot, a movement called the grand jete. Analysis was performed on the students' landing. Independent variables were 3 shoe types: split sole, traditional out sole, and 5-toed forefoot shoes, with bare feet as a control group. Dependent variables were vertical passive ground reaction force and qualitative elements. Passive ground reaction force variables(maximum passive peak value, number of passive peaks, passive force-time integral, and center of pressure) were measured by the Kistler 9281B Force Platform. Qualitative elements were comfort, cushioning, pain, and fit. Statistical analysis included both 1-way ANOVA and Tukey's test for follow-up. Finalized data demonstrated that the 5-toed forefoot shoe allows the forefoot to expand and the toes to individually press down upon landing, increasing foot contact with the surface. Five-toed forefoot shoes minimize passive peaks and pain, while increasing comfort, cushioning, and fit. Most ballet movements are composed of jumping, balancing, landing, and spinning. Wearing 5-toed forefoot shoes allows for a natural range of movement in each toe, to improve both technique and balance. Pain and injuries from ballet can be minimized by wearing the correct shoe type. According to this analysis, it is possible to customized ballet shoes to increase the efficiency of techniques and movements.

수동 소나 배열을 이용한 수중 음향 영상에 관한 연구

  • 김형균
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1984.12a
    • /
    • pp.96-99
    • /
    • 1984
  • In this study, the underwater acoustic images were obtained by ultrasonicwave. The experiment was performed in the anechoic watertank, using a passive sonar array for one and two sound source respectively by X-Y scanning technique. The receiving array was consist of 8 disc type transducers with 1.5cm diameter at 25KHz resonance frequency. The scanned data were processed by the FORTRAN IV algorithm for the reconstruction of image, and the image had some noise due to the surface reflected waves. As the result, it was found that the acoustic imaging by electrical deflection and dynamic focusing technique is applicable to SONAR with the suppression of surface reflected wave.

  • PDF

Polarization Phase-shifting Technique in Shearographic System with a Wollaston Prism

  • Kim, Soo-Gil
    • Journal of the Optical Society of Korea
    • /
    • v.8 no.3
    • /
    • pp.122-126
    • /
    • 2004
  • The method to obtain four speckle patterns with relative phase shift of ${\pi}/2$ by passive devices such as two waveplates and a linear polarizer, awl to calculate the phase at each point of the speckle pattern in shearography with a Wollaston prism is presented, and the feasibility of the proposed method is theoretically demonstrated by Jones vector.

Comparison of semi-active and passive tuned mass damper systems for vibration control of a wind turbine

  • Lalonde, Eric R.;Dai, Kaoshan;Bitsuamlak, Girma;Lu, Wensheng;Zhao, Zhi
    • Wind and Structures
    • /
    • v.30 no.6
    • /
    • pp.663-678
    • /
    • 2020
  • Robust semi-active vibration control of wind turbines using tuned mass dampers (TMDs) is a promising technique. This study investigates a 1.5 megawatt wind turbine controlled by eight different types of tuned mass damper systems of equal mass: a passive TMD, a semi-active varying-spring TMD, a semi-active varying-damper TMD, a semi-active varying-damper-and-spring TMD, as well as these four damper systems paired with an additional smaller passive TMD near the mid-point of the tower. The mechanism and controllers for each of these TMD systems are explained, such as employing magnetorheological dampers for the varying-damper TMD cases. The turbine is modelled as a lumped-mass 3D finite element model. The uncontrolled and controlled turbines are subjected to loading and operational cases including service wind loads on operational turbines, seismic loading with service wind on operational turbines, and high-intensity storm wind loads on parked turbines. The displacement and acceleration responses of the tower at the first and second mode shape maxima were used as the performance indicators. Ultimately, it was found that while all the semi-active TMD systems outperformed the passive systems, it was the semi-active varying-damper-and-spring system that was found to be the most effective overall - capable of controlling vibrations about as effectively with only half the mass as a passive TMD. It was also shown that by reducing the mass of the TMD and adding a second smaller TMD below, the vibrations near the mid-point could be greatly reduced at the cost of slightly increased vibrations at the tower top.

Comparisons Fitness in Implant Abutment between Gas Soldering and Laser Welding

  • Cho, Mi-Hyang;Nam, Shin-Eun
    • International Journal of Clinical Preventive Dentistry
    • /
    • v.14 no.4
    • /
    • pp.247-255
    • /
    • 2018
  • Objective: Osseointegration is essential process for successful implants and effects to implant in long term, therefore, passive fitness of good prosthesis is necessary. To make a good prosthesis, at first it should be done a sectioned casting and then joined method of sectioned casting body is recommended. Methods: In this study, to provide the fundamental data on stable connection method for successful implants, the author tested fitness of casting body, and compared difference between gas soldering technique and laser welding technique. Results: In fitness test of 2 abutment (test A, C), gas soldering group's fitness in the opposite part of connection was worse than laser welding group. In fitness test of 3 abutment (test B, D), gap distance was increased both in gas soldering technique and laser welding technique. Gap distance at the connecting part and the opposite part of the abutment in gas soldering technique was worse than laser welding technique and the more additional abutment, the worse gap distance in gas soldering technique. In fitness test of 3 abutment (test B, D), there's little variation in No. 2 abutment when connecting soldering process was done and there's little influence on already soldered connection part when the additional soldering connection was done. Conclusion: On weak loading condition and the part which is needed an accuracy, laser welding technique is more effective and on long-span prosthesis and frequent chewing loading part, laser welding technique is recommended first and applying additional gas soldering technique would be better for making much more successful prosthesis.

Effect of passive ultrasonic agitation during final irrigation on cleaning capacity of hybrid instrumentation

  • Vinhorte, Marcilene Coelho;Eduardo Hideki, Suzuki;Maira Sousa, De Carvalho;Andre Augusto Franco, Marques;Emilio Carlos Junior, Sponchiado;Lucas Da Fonseca Roberti, Garcia
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.2
    • /
    • pp.104-108
    • /
    • 2014
  • Objectives: To evaluate the effect of passive ultrasonic agitation on the cleaning capacity of a hybrid instrumentation technique. Materials and Methods: Twenty mandibular incisors with mesiodistal-flattened root shape had their crowns sectioned at 1 mm from the cementoenamel junction. Instrumentation was initiated by catheterization with K-type files (Denstply Maillefer) #10, #15, and #20 at 3 mm from the working length. Cervical preparation was performed with Largo bur #1 (Dentsply Maillefer) followed by apical instrumentation with K-type files #15, #20 and #25, and finishing with ProTaper F2 file (Denstply Maillefer). All files were used up to the working length under irrigation with 1 mL of 2.5% sodium hypochlorite (Biodyn$\hat{a}$mica) at each instrument change. At the end of instrumentation, the roots were randomly separated into 2 groups (n = 10). All specimens received final irrigation with 1 mL of 2.5% sodium hypochlorite. The solution remained in the root canals in Group 1 for one minute; and ultrasonic agitation was performed in Group 2 for one minute using a straight tip inserted at 1 mm from working length. The specimens were processed histologically and the sections were analyzed under optic microscope (x64) to quantify debris present in the root canal. Results: The samples submitted to ultrasonic agitation (Group 2) presented significant decrease in the amount of debris in comparison with those of Group 1 (p < 0.05). Conclusions: The hybrid instrumentation technique associated with passive ultrasonic agitation promoted greater debris removal in the apical third of the root canals.

Techniques for Efficient Reading of Semi-Passive Sensor Tag Data (반수동형 센서 태그 데이터의 효율적인 읽기 기법)

  • Kim, Soo-Han;Ryu, Woo-Seok;Hong, Bong-Hee
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.3
    • /
    • pp.34-41
    • /
    • 2009
  • This paper investigates the issue of efficient reading for sensor data of semi-passive sensor tag. The Cold Chain management system requires complete sensor data without data loss and the short processing time of reading sensor tag data. However, reading the sensed data could be interfered by RF environment such as a jamming, obstacle and so on. This study found that it could lead to loss of the sensed data and takes much time to read it when data loss is occurred. To solve this problem, we propose the transaction processing mechanism that guarantees efficient reading of the sensed data. To do this, we present the technique of dynamic packet size and technique of data recovery to execute read transaction. These techniques improve the reliability of reading operation as well as speed up of read process for the large capacity data. This paper contributes to the improvement of efficient reading of sensed data without any loss of data and large time required.

An Implementation of a RFID Reader Firmware for ISO/IEC 18000-6 Type B Specification (ISO/IEC18000-6 Type B 규격에 적합한 리더 펌웨어 개발)

  • Yang, Jing-Gil;Bae, Sung-Woo;Jung, Myung-Sub;Jang, Byung-Jun;Kim, Jun-O;Park, Jun-Seok;Seong, Yeong-Rak;Oh, Ha-Ryoung
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.1039-1042
    • /
    • 2005
  • Recently, a considerable number of studies have been made on the $RFID^{[1-6]}$ systems. RFID is a technique of identifying an object using radio frequency transmission. The technology can be used to identify, track, sort or detect a wide variety of objects. The RFID system is composed of two main elements: a reader and a tag. Tags can either be active (powered by battery) or passive (powered by the reader field). The passive tags communicate back to the reader with a technique called 'backscatter'. RFID technology can be applied to the supply chain, security, logistics industry and etc. Especially, UHF RFID is worth noticing because of its relatively long identification range and commercial UHF RFID systems are under development. In this paper, we designed and implemented a UHF RFID reader firmware for ISO/IEC 18000-6 Type B specification.

  • PDF