• Title/Summary/Keyword: Passive load-pull

Search Result 9, Processing Time 0.02 seconds

Pulsed-Bias Pulsed-RF Passive Load-Pull Measurement of an X-Band GaN HEMT Bare-chip (X-대역 GaN HEMT Bare-Chip 펄스-전압 펄스-RF 수동 로드-풀 측정)

  • Shin, Suk-Woo;Kim, Hyoung-Jong;Choi, Gil-Wong;Choi, Jin-Joo;Lim, Byeong-Ok;Lee, Bok-Hyung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.1
    • /
    • pp.42-48
    • /
    • 2011
  • In this paper, a passive load-pull using a GaN HEMT (Gallium Nitride High Electron Mobility Transistor) bare-chip in X-band is presented. To obtain operation conditions that characteristic change by self-heating was minimized, pulsed drain bias voltage and pulsed-RF signal is employed. An accuracy impedance matching circuits considered parasitic components such as wire-bonding effect at the boundary of the drain is accomplished through the use of a electro-magnetic simulation and a circuit simulation. The microstrip line length-tunable matching circuit is employed to adjust the impedance. The measured maximum output power and drain efficiency of the pulsed load-pull are 42.46 dBm and 58.7%, respectively, across the 8.5-9.2 GHz band.

Stress Analysis Acting on Electric Pole using Strain Gauge from Full Scale Pull-Out Test (실물인장실험시 변형률계를 이용한 전주에 작용하는 응력분석)

  • Ahn, Tae-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.49-55
    • /
    • 2010
  • Many electric poles in the softground have been collapsed due to external load. In this study, 10 types of tests were performed with variation of location, numbers and depths of anchor blocks as well as depth of poles to find stresses acting on concrete electric poles. The stresses of concrete poles are relaxed at 600~700[kg] of tensile load, and stresses are concentrated at top of pole, and spread to lower part of pole. In the concrete pole collapse test, tensile load at failure was approximately 1,400[kg], which is twice of design load. As passive zone in the soil increases, the stresses acting on concrete pole are concentrated at lower part of pole based on moment arm earth pressure distribution.

An Antenna-Integrated Oscillator Design Providing Convenient Control over the Operating Frequency and Output Power (동작주파수 및 출력파워 조절이 용이한 신호생성용 안테나 설계)

  • Lee, Dong-Ho;Lee, Jong-In;Kim, Mun-Il
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.1
    • /
    • pp.54-58
    • /
    • 2006
  • A new design for easily controlling operating frequency of an antenna-integrated planar oscillator is introduced. The oscillator circuit of a broadband negative-resistance active part and a passive load including a patch antenna. The patch resonance is used for determining the oscillation frequency. This design reduces the possibility of mismatch between antenna radiation and oscillation frequencies. To achieve optimum output power, load-pull simulation for the negative-resistance circuit is used. The load-pull simulation shows the feed point and the delay of feed line can affect the oscillation power. Two negative-resistance circuits capable of supporting oscillation over full C-band and X-band are fabricated. The oscillation frequency, output power and phase noise for different patch antennas are measured.

  • PDF

Study of Soil Nailing Application as a Reinforcement Method for Slided Slope (붕괴사면보강을 위한 Soil Nailing의 적용성에 관한 연구)

  • 이성철;김명학
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.127-134
    • /
    • 2000
  • Soil nailing is in-situ ground improvement technique of reinforcing soils using passive inclusions for the purpose of slope stability. Also soil nailing, in general, was used and studied as a reinforcement technique at cut slope, but this paper presents the results of study for soil nailing application as a reinforcement technique at the banking over slided slope. In-situ pull-out tests of nails, instrumented with strain gauges, were performed to investigate the maximum pull-out load and to calculate the unit side resistance in each different layer. And the apparent average unit side resistance of this study was compared with that of other sites installed at cut slope.

  • PDF

Lateral Earth Pressures and Displacements through Full Scaled Lateral Loading Test of Concrete Electric Pole Embedded in Ground (지중에 근입된 콘크리트전주의 실물 수평재하실험에 의한 수평토압과 변위특성)

  • Ahn, Tae-Bong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.4
    • /
    • pp.43-51
    • /
    • 2011
  • Many electric poles in the softground have been collapsed due to external load. In this study, 10 types of tests were performed with variation of location, numbers and depths of anchor blocks as well as depth of poles to find horizontal earth pressure through full scale pull-out tests. The horizontal earth pressure increased with embedded depth of electric pole, and earth pressure of lower passive zone decreased. The deeper of anchor block, earth pressure of passive zone becomes less. lateral displacements showed differences depending on location, numbers and depth of poles. The bending is generated in the upper part at the initial load, but it moved to central part as load increased. The maximum horizontal displacement decreased to 1/1.6 at -0.5m depth of anchor block and 1.3m additional laying depth of poles into ground.

Stress distribution in a passive fully grouted rock bolts

  • Karanam U. M. Rao;Dasyapu S. K.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.122-128
    • /
    • 2003
  • Rock bolts are widely used as a supplementary roof support system in hard-rock mining since a long time. Since the performance of fully grouted passive bolts depends on bond strength, in the present investigation extensive laboratory pull-out as well as push-out tests were conducted varying the bolt diameter, length and cement-water mixing ratios of grout. The load-displacement curves were developed and were verified with the numerical results obtained from finite element analysis using ALGOR software. Numerical models were validated for push-out tests and a detailed analysis was carried out to know the displacement, stress, strain distribution along the bolt.

  • PDF

Electronic Ballast using Current-Fed Push-Pull Resonant Inverter with Single-Stage Power Factor Correction Circuit (전류원 방식 푸시-풀 공진형 인버터로 구성된 단일단 고역률 형광등용 전자식 안정기)

  • Chae, Gyun;Ryoo, Tae-Ha;Cho, Gyu-Hyeong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.5
    • /
    • pp.501-507
    • /
    • 2000
  • A nobel low-cost, simple and unity-power-factor electronic ballast is presented. The proposed electronic ballast employs a bypassing capacitor- and load networks composed of ballast capacitors and small charge pump capacitors as power factor correction circuit combined with the secondary winding of the transformer in the self-excited current-fed push-pull resonant inverter(CF-PPRI), resulting in cost-effectiveness and higher efficiency. By analyzing the princip1es of power factor correction mathematically, optimum design guidelines are presented. Since the lamps are used in power factor correction stage, the input power is automatically adjusted according to the number of the lamps.

  • PDF

Horizontal Stress Analysis of Electric Pole using Earth Pressure Cell from Mock-Up Tension Test (전주의 실물인장실험시 토압계를 이용한 수평토압분석)

  • Ahn, Tae-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.62-69
    • /
    • 2010
  • Many electric poles in the softground have been collapsed due to external load. In this study, 10 types of tests were performed with variation of location, numbers and depths of anchor blocks as well as depth of poles to find horizontal earth pressure through full scale pull-out tests. The horizontal earth pressure increased with embedded depth of electric pole, and earth pressure of lower passive zone decreased. The deeper of anchor block, earth pressure of passive zone becomes less. 4 anchor blocks decreased earth pressure at G.L.-0.9[m]. It is considered that 4 anchor blocks installed along 80[cm] vertically are main reason. Overall, when more anchor blocks are constructed, excavation area is large, and constructivity such as backfill is bad, therefore one anchor block would be preferred.

Effects of Anchor Block on Stability of Concrete Electric Pole (콘크리트전주의 안정성에 미치는 근가의 영향)

  • Ahn, Tae-Bong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.11
    • /
    • pp.5-10
    • /
    • 2012
  • Many electric poles in the softground have been collapsed due to external load. In this study, several tests were performed with variation of numbers and depths of anchor blocks to find effects of anchor blocks on stability of concrete electric poles through earth pressure and displacement analysis. 1.50m depth of anchor block seems appropriate among three kinds of depths. The 2.25m depth of anchor block makes larger displacement due to disturbance caused by excessive excavation. The deeper anchor block, the less earth pressure of passive zone, an active earth pressure gets larger. When two anchor blocks were installed, displacement at top pole decreased 43.8% and 55.6% at ground when 1 anchor block was installed.