• Title/Summary/Keyword: Passive filter

Search Result 359, Processing Time 0.026 seconds

Suppressing Effect of Medicinal Plants on the Intestinal Absorption of Heavy Metals (생약재에 의한 중금속의 체내흡수 억제 효과)

  • Choi, Sung-Inn;Hwang, Jin-Bong;Kwon, Joong-Ho;Kim, Hyun-Ku
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.456-460
    • /
    • 1998
  • This research was attempted to prove suppressing effect of medicinal plants on the intestinal absorption of toxic heavy metals. In vitro study was performed by membrane filtration considering intestinal absorption conditions. From drinking water contaminated singly with 10 and 50 times level of water quality standard for heavy metals, the removal ratio of lead was $40{\sim}60%$ by Chicorium intybus, Angelica acutiloba and Ganoderma lucidium. And the removal ratio of cadmium was $20{\sim}40%$. The removal ratio of lead contaminated with both was $30{\sim}50%$ by every sample similarly, the removal ratio of cadmium was $10{\sim}30%$. The removal ratio of Angelica acutiloba was more higher than Chicorium intybus and Ganoderma lucidium. Considering the extraction conditions of samples, $70^{\circ}C$, 2 min conditions were higher than $95^{\circ}C$, 10 min conditions, the removal ratios of heavy metals were similar. And the membrane filter permeated the material under 500 mw selectively, so the final filtrate could regard as passive transport in intestinal absorption. In conclusion, this research exhibited that the medicinal plants beverages have a suppressing effect on intestinal absorption of lead and cadmium in drinking water.

  • PDF

The Study on $Na^+-Ca^{++}$ Exchange in Heart Mitochondria (심근 Mitochondria의 $Na^+-Ca^{++}$교환에 관한 연구)

  • Shin, Sang-Goo;Kim, Myung-Suk;Lim, Jung-Kyoo
    • The Korean Journal of Pharmacology
    • /
    • v.18 no.2
    • /
    • pp.89-102
    • /
    • 1982
  • The $Na^+-and\;K^+-induced\;Ca^{++}$ release was measured isotopically by millipore filter technique in pig heart mitochondria. With EGTA-quenching technique, the characteristics of mitochondrial $Ca^{++}-pool$ and the sources of $Ca^{++}$ released from mitochondria by $Na^+\;or\;K^+$ were analyzed. The mitochondrial $Ca^{++}-pool$ could be distinctly divided into two components: internal and external ones which were represented either by uptake through inner membrane, or by energy independent passive binding to external surface of mitochondria, respectively. In energized mitochondria, a large portion of $Ca^{++}$was transported into internal pool with little external binding, while in de-enerigzed state, a large portion of transported $Ca^{++}$ existed in the external pool with limited amount of $Ca^{++}$ in the internal pool which was possibly transported through the $Ca^{++}-carrier$ present in the inner membrane. $Na^+$ induced the $Ca^{++}$ release from both internal pool and external pool and external binding pool of mitochondria. In contrast, $K^+$ did not affect $Ca^{++}$ of the internal pool, but, displaced $Ca^{++}$ bound to external surface of the mitochondria. When the $Ca^{++}-reuptake$ was blocked by EGTA, the $Ca^{++}$ release from the internal pool by $Na^+$ was rapid; the rate of $Ca^{++}-efflux$ appeared to be a function of $[Na^+]^2$ and about 8mM $Na^+$ was required to elicit half-maximal velocity of $Ca^{++}-efflux$. So it was revealed that $Ca^{++}-efflux$ velocity was particulary sensitive to small changes of the $Na^+$ concentration in physiological range. Energy independent $Ca^{++}-binding$ sites of mitochondrial external surface showed unique characteristics. The total number of external $Ca^{++}-binding$ sites of pig heart mitochondria was 29 nmoles per mg protein and the dissociation constant(Kd) was $34{\mu}M$. The $Ca^{++}-binding$ to the external sites seemed to be competitively inhibited by $Na^+\;and\;K^+$; the inhibition constant(Ki) were 9.7 mM and 7.1 mM respectively. Considering the intracellular ion concentrations and large proportion of $Ca^{++}$ uptake in energized mitochondria, the external $Ca^{++}-binding$ pool of the mitochondria did not seem to play a significant role on the regulation of intracellular free $Ca^{++}$ concentration. From this experiment, it was suggested that a small change of intracellular free $Na^+$ concentration might play a role on regulation of free $Ca^{++}$ concentration in cardiac cell by influencing $Ca^{++}-efflux$ from the internal pool of mitochondria.

  • PDF

The Application of Relays for Noise Reduction in the Combat Vehicle Distribution Box (전투차량용 분배함의 노이즈 감소를 위한 릴레이 응용)

  • Kwak, Daehwan;Park, Dong Min;Oh, Eunbin;Kim, Chang Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.235-240
    • /
    • 2020
  • This study evaluated the improvements for circuits of a combat vehicle distribution box to reduce the noise generated in electromagnetic compatibility (EMC) testing. An analysis of the distribution boxes that failed the standard revealed the conducted noise generated from the converter and semiconductor switching elements on the circuit board. The distribution box transfers power from the generator and battery to the cooling system of a combat vehicle to keep turning the air conditioner on and off. Two methods were proposed to overcome this problem: a passive filter was added to the circuit board for the first method, and the converter and switching elements were replaced with the relays for the second method. Both methods were effective in reducing noise, but a greater improvement was obtained from the second method. The second method was applied to a combat vehicle system and was found to be suitable according to the EMC standards.

A Study on Preference of Smoking Booth Design (흡연 부스 디자인의 선호도 조사 연구)

  • Yang, Keun-Young
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.1
    • /
    • pp.183-192
    • /
    • 2017
  • This study aims to suggest improved design for both non-smokers and smokers to minimize inconvenience of smoke, at the same time, allow smoking in comfortable environment. The study was researched in three categories: First, consciousness research regarding smoking booth, second, preference research regarding product design, and third, research on emotional words about smoking booth by emotion evaluation. The result of design preference research was, first of all, smoking booth for smokers should be designed in both notable and familiar shape rather than stiff and rough shape. Second, color for the booth should apply warm colors such as white, pastel, and bright tone rather than prime colors. Third, the internal circulation filter in smoking booth should be managed thoroughly. In addition, extra seats and ventilation design is necessary to prevent passive smoking. The result of emotion evaluation was that people recognized certain words in four aspects. Each image word for factor 1 was "functional emotion', factor 2 was "psychological emotion", factor 3 as "color emotion", and factor 4 as "shape emotion". User-centered service design is necessary for both smokers and non-smokers, to minimize the damage by smoke and to spend time for short break.

A 2.5 Gb/s Burst-Mode Clock and Data Recovery with Digital Frequency Calibration and Jitter Rejection Scheme (디지털 주파수 보정과 지터 제거 기법을 적용한 2.5 Gb/s 버스트 모드 클럭 데이터 복원기)

  • Jung, Jae-Hun;Jung, Yun-Hwan;Shin, Dong Ho;Kim, Yong Sin;Baek, Kwang-Hyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.87-95
    • /
    • 2013
  • In this paper, 2.5 Gb/s burst-mode clock and data recovery(CDR) is presented. Digital frequency calibration scheme is adopted to eliminate mismatch between the input data rate and the output frequency of the gated voltage controlled oscillator(GVCO) in the clock recovery circuitry. A jitter rejection scheme is also used to reduce jitter caused by input data. The proposed burst-mode CDR is designed using 0.11 ${\mu}m$ CMOS technology. Post-layout simulations show that peak-to-peak jitter of the recovered data is 14 ps with 0.1 UI input referred jitter, and maximum tolerance of consecutive identical digit(CID) is 2976 bits without input data jitter. The active area occupies 0.125 $mm^2$ without loop filter and the total power consumption is 94.5 mW.

STSAT-3 Main Payload, MIRIS Flight Model Developments

  • Han, Won-Yong;Lee, Dae-Hee;Park, Young-Sik;Jeong, Woong-Seob;Ree, Chang-Hee;Moon, Bong-Kon;Park, Sung-Joon;Cha, Sang-Mok;Nam, Uk-Won;Park, Jang-Hyun;Lee, Duk-Hang;Ka, Nung-Hyun;Seon, Kwang-Il;Yang, Sun-Choel;Park, Jong-Oh;Rhee, Seung-Wu;Lee, Hyung-Mok;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.40.1-40.1
    • /
    • 2010
  • The Main payload of the STSAT-3 (Korea Science & Technology Satellite-3), MIRIS (Multipurpose Infra-Red Imaging System) has been developed for last 3 years by KASI, and its Flight Model (FM) is now being developed as the final stage. All optical lenses and the opto-mechanical components of the FM have been completely fabricated with slight modifications that have been made to some components based on the Engineering Qualification Model (EQM) performances. The components of the telescope have been assembled and the test results show its optical performances are acceptable for required specifications in visual wavelength (@633 nm) at room temperature. The ensuing focal plane integration and focus test will be made soon using the vacuum chamber. The MIRIS mechanical structure of the EQM has been modified to develop FM according to the performance and environment test results. The filter-wheel module in the cryostat was newly designed with Finite Element Analysis (FEM) in order to compensate for the vibration stress in the launching conditions. Surface finishing of all components were also modified to implement the thermal model for the passive cooling technique. The FM electronics design has been completed for final fabrication process. Some minor modifications of the electronics boards were made based on EQM test performances. The ground calibration tests of MIRIS FM will be made with the science grade Teledyne PICNIC IR-array.

  • PDF

Characteristics of PM10, VOCs and Aldehydes Levels in Nail and Hair Shops (네일샵미용실의 실내공기 중 미세먼지(PM10), 휘발성 유기화합물 (VOCs), 알데하이드류(Aldehydes)의 농도 및 업소 특성에 따른 상관성 분석)

  • Lee, Boram;Kuag, Sooyoung;Yang, Wonho;Jun, Sang il;Kim, Jung-su;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.6
    • /
    • pp.509-515
    • /
    • 2017
  • Objectives: The purpose of this study was to assess the indoor levels of $PM_{10}$, VOCs and aldehydes in nail shop and hair salon. Methods: The field survey was conducted for 52 hair salons 52 nail shops, and 26 shop-in-shops in Seoul and Daegu city. The field technicians investigated characteristics of each shop including operating time, indoor volume, ventilation and so on. Indoor concentrations of $PM_{10}$, VOCs and aldehydes, indoor temperature and humidity were measured in 12 hair salons, 12 nail shops and 6 shop-in shops. MP Surveryor II (Graywolf, USA) was used to measure $CO_2$ concentration, temperature and humidity for 8 hours. $PM_{10}$ concentrations were measured by minivolume air sampler with Teflon quartz filter ($0.2{\mu}m$ pore size, ${\varphi}$ 47 mm, Graseby-Anderson TEF-DISKTM) for 6 hours. VOCs passive sampler (OVM 3500) was used to collect VOCs for 8 hours and analyzed by GC/MSD. Results: The $CO_2$ concentrations were $759.4{\pm}58.2$ ppm in nail shops, $731.0{\pm}72.5$ ppm in hair salons, and $656.4{\pm}31.2$ ppm in shop-in-shops. The $PM_{10}$ concentrations were $27.5{\pm}14.2{\mu}g/m^3$ in nail shops, $33.1{\pm}6.3{\mu}g/m^3$ in hair salons, and $39.0{\pm}26.9{\mu}g/m^3$ in shop-in-shops. TVOCs concentrations were $3085.4{\pm}1667.8{\mu}g/m^3$ in nail shops, $2131.1{\pm}617.3{\mu}g/m^3$ in hair salons, and $1550.3{\pm}529.0{\mu}g/m^3$ in shop-in-shops. TVOCs concentrations in nail shops were significantly higher than those in hair salons and shop-in-shops (p=0.002). Formaldehyde concentrations were $60.8{\pm}36.6{\mu}g/m^3$ in nail shops, $89.1{\pm}55.4{\mu}g/m^3$ in hair salons, and $45.1{\pm}22.5{\mu}g/m^3$ in shop-in-shops. Conclusion: TVOCs concentrations in nail shop were the highest among others. TVOC concentrations in all stores exceeded indoor air quality stand of indoor air quality control in public-use facilities, etc act.

Efficient Mutual Authentication Protocol Suitable to Passive RFID System (수동형 RFID 시스템에 적합한 효율적인 상호 인증 프로토콜 설계)

  • Won, Tae-Youn;Chun, Ji-Young;Park, Choon-Sik;Lee, Dong-Hoon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.18 no.6A
    • /
    • pp.63-73
    • /
    • 2008
  • RFID(Radio Frequency IDentification) system is an automated identification system that basically consists of tags and readers and Back-End-Databases. Tags and Readers communicate with each other by RF signal. As a reader can identify many tags in contactless manner using RF signal, RFID system is expected to do a new technology to replace a bar-code system in supply-chain management and payment system and access control and medical record and so on. However, RFID system creates new threats to the security of systems and privacy of individuals, Because tags and readers communicate with each other in insecure channel using RF signal. So many people are trying to study various manners to solve these problems against attacks, But they are difficult to apply to RFID system based on EPCglobal UHF Class-1 Generation-2 tags. Recently, Chien and Chen proposed a mutual Authentication protocol for RFID conforming to EPCglobal UHF Class-1 Generation-2 tags. we discover vulnerabilities of security and inefficiency about their protocol. Therefore, We analyze vulnerabilities of their protocol and propose an efficient mutual authentication protocol that improves security and efficiency.

A Study On Design of ZigBee Chip Communication Module for Remote Radiation Measurement (원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈 설계에 대한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.552-558
    • /
    • 2014
  • This paper suggests how to design a ZigBee-chip-based communication module to remotely measure radiation level. The suggested communication module consists of two control processors for the chip as generally required to configure a ZigBee system, and one chip module to configure a ZigBee RF device. The ZigBee-chip-based communication module for remote radiation measurement consists of a wireless communication controller; sensor and high-voltage generator; charger and power supply circuit; wired communication part; and RF circuit and antenna. The wireless communication controller is to control wireless communication for ZigBee and to measure radiation level remotely. The sensor and high-voltage generator generates 500 V in two consecutive series to amplify and filter pulses of radiation detected by G-M Tube. The charger and power supply circuit part is to charge lithium-ion battery and supply power to one-chip processors. The wired communication part serves as a RS-485/422 interface to enable USB interface and wired remote communication for interfacing with PC and debugging. RF circuit and antenna applies an RLC passive component for chip antenna to configure BALUN and antenna impedance matching circuit, allowing wireless communication. After configuring the ZigBee-chip-based communication module, tests were conducted to measure radiation level remotely: data were successfully transmitted in 10-meter and 100-meter distances, measuring radiation level in a remote condition. The communication module allows an environment where radiation level can be remotely measured in an economically beneficial way as it not only consumes less electricity but also costs less. By securing linearity of a radiation measuring device and by minimizing the device itself, it is possible to set up an environment where radiation can be measured in a reliable manner, and radiation level is monitored real-time.