Since 1980's during which environmental pollution became serious enough to urge various types of environmental educations in many areas. But, most emphasis has been put on theoretical education. Even field education training mostly focused on water pollution. Therefore, simple air pollution monitoring system was needed for better field education in air pollution. In this study, we evaluated Passive Sampler as an useful tool for teaching air pollution in field. Students have found passive sampler very effective tool. Recent comparative study of auto-monitoring and passive sampler networks suggested a potential use of passive sampler as an useful tool for environmental education. In this study, the correlation between two sets of values appears very high judging from the regression slope of 0.92 and correlation coefficient of 0.91 However, inexpensive Passive sampler with easy-to-operate colorimeter, has not been used in environmental education partially because large scale fluctuation in time and space characteristic to air pollution has been overlooked so that the sampler has not been tested for an effective educational tool. Passive sampler certainly deserves further in depth research as an effective air monitoring system, and better attention to its usefulness to teach students and public.
Filter badge type sampler has not been widely used to evaluate air quality over large cities in Korea while it can be successfully used for multi-point sampling and analysis. We evaluated the passive sampler as a new tool to monitor air quality over large cities. We latticed Metropolitan Seoul into $2{\times}2Km$ to give 136 points. $NO_2$ concentrations were measured at all the points in the Spring and Summer of 1997. According to the passive sampler data, natural green zones generally recorded lower $NO_2$ concentrations than major streets and traffic congestion areas. Passive samplers with abundant 136 points gave more detailed picture of $NO_2$ distribution while auto-monitoring network did not clearly provide the characteristics of local land use. Also, passive samplers gave 15% higher values than auto-monitoring network. The correlation between the two values appears very high judging from the regression slope of 0.92 and correlation coefficient of 0.91. This study clearly demonstrates the effectiveness of the passive sampler as a tool to monitor air quality over large cities.
Passive sampler is a simple and cost-effective measuring equipment for ambient and indoor air pollution. We studied the performance of a short term (1 hour mean concentration) ozone passive sampler which was coated with a colorant (indigo carmine) to a filter substrate. Acetone and sulfamic acid added ozone passive sampler was investigated to measure short term mean ozone concentration. Ozone response and interference of criteria air pollutant($SO_2,\;NO_2$, CO) on a short term ozone passive sampler was tested through experimental chamber. The results show sulfamic acid added passive ozone sampler have good response in ozone exposure. Interference of $NO_2$ gas is larger than other two criteria gases.
Journal of Korean Society for Atmospheric Environment
/
v.22
no.6
/
pp.904-911
/
2006
Passive sampler is simple and inexpensive measuring equipment for air pollution. In this study we developed colorimetric ozone passive sampler which was coated a colorimetric reagent to a filter substrate. Interference of criteria all pollutant ($SO_2,\;NO_2,\;CO$) on ozone passive sampler was investigated through experimental chamber. Field measurement of developed ozone passive samper was compared automatic sampler result in Suwon area. The results shows interference of $SO_2$ gas is larger than other gases. Developed passive sampler can be roughly applicable to wind speed range from 0.8 to 3.3 m/s, temperature range from 3.9 to $27.5^{\circ}C$ and relative humidity range from 48 to 84%.
Journal of Korean Society for Atmospheric Environment
/
v.20
no.4
/
pp.483-491
/
2004
The purpose of this study is to develop an ozone passive sampler and to evaluate its performance p-Acetamidophenol using as the reagent for ozone reacts specifically with the ambient ozone to produce a fluorescence material (p-acetamidopheonl dimer). The volume of absorbent solution and the extraction time determined at suitable conditions for measuring ozone were 100$\mu$L and 60 min, respectively. The changes of fluorescence were observed with incresing the storage period of passive samplers in ambient air. but the cool storage in a refrigerator did not remarkably influence the increase of fluorescence. The measurement for the precision oi the passive sampling was carried out with duplicate measurement of passive samplers. The intra-class correlation coefficients of passive samplers using dry and wet filters were 0.992 and 0.962, respectively The results from field validation tests indicated practical agreement (dry filter: r=0.963, wet filter: r=0.995) between the passive sampler and an UV photometric $O_3$ analyzer. The limit of quantification of ozone passive samplers with sampling time of 8 hr (wet filter) and 24 hr (dry filter) were 8.0 ppb and 2.7 ppb, respectively.
Objective: This study was carried out to use pine needles as a passive air sampler (PAS) of atmospheric Polychlorinated Biphenyls (PCBs). Methods: PCB concentrations in ambient air ($C_a$, ng/$m^3$) and deposited on pine needles ($C_p$, ng/g dry) were analyzed simultaneously from June 1 to December 31. Air samples were taken using a low volume PUF active air sampler and the overall average air volume was about 900-1,000 $m^3$. Pine needles were collected at the end of August and December near the air sampler. Results: $C_a$ were higher at higher air temperature and lower chlorinated PCB congeners, but $C_p$ showed irregular distribution. The average PCB sampling rates from air to pine needles were 0.116 (0.002-0.389) $m^3$/day - g dry. Conclusions: A poor correlation was shown between $C_a$ and $C_p$. However, a good correlation was shown between the logarithm of octanol-air partitioning coefficient ($logK_{oa}$) and log ($C_p/C_a$), and the interrelation was better with longer sampling time (June to December) than shorter sampling time (June to August). The average PCB sampling rates from air to pine needles were the lowest with respect to PUF disk, XAD-2 resin and semipermeable membrane devices (SPMDs) PAS. The average ratio ($C_{a-calc}/C_{a-meas}$) of calculated ($C_{a-calc}$) and measured ($C_{a-meas}$) PCB concentration was 0.69 with a shorter sampling time and 1.24 with a longer, so $C_{a-calc}$ was close to $C_{a-meas}$. It was found that pine needles can be used as PAS of atmospheric PCBs, and are especially suitable for long-time PAS.
Objectives: This study was carried out in order to estimate atmospheric polycyclic aromatic hydrocarbon (PAH) concentrations and sources using pine needles as a passive air sampler (PAS) in urban (Pyeongtaek), semirural (Anseong) and rural (Jincheon) sites. Methods: One-year-old pine needles were collected for analysis of their PAH concentrations ($C_{p,n}g/g$ dry) at the end of December. PAHs concentrations in the ambient air ($C_a$, $ng/m^3$) were calculated with a $Log(C_p/C_a)-LogK_{oa}$ correlational equation. Results: PAHs concentrations in ambient air ($C_a$) were high, in the order of urban ($114.03ng/m^3$), semirural ($105.17ng/m^3$) and rural ($61.91ng/m^3$) sites. However, distributions of PAH isomer concentrations were very similar. PAHs of which molecular weight is smaller than 228.30 (AcPy, Acp, Flu, Phen, Ant, Flt, Pyr, BaA, Chry) made up most of the PAHs in the ambient air (96.6-98.5%). Conclusion: At urban, semirural and rural sites, it was concluded that the main source of PAHs in the ambient air ratio of each PAH isomer concentration was cars, especially diesel vehicles.
Proceedings of the Korea Air Pollution Research Association Conference
/
2001.11a
/
pp.319-320
/
2001
Passive sampler는 현장에서 제약 없이 사용할 수 있다는 간편성과 그 측정결과의 정확성, 정밀성에 대하여 입증된 바 있는 측정도구로써 대기질 측정 및 모니터링뿐만 아니라 최근에는 대기확산모델의 검증자료로도 활용되고 있다(김선태, 2001). 이러한 측정방법은 국내의 경우 1992년 이후 한정적으로 사용되었으나, 최근에는 국내뿐 아니라 해외에서도 passive sampler를 사용하는 사례가 증가하고 있으며, UNEP에서도 다양한 목적으로의 활용성을 언급하고 있다(UNEP, 1994). (중략)
Objective: This study was carried out to use pine needles as a passive air sampler (PAS) for atmospheric polychlorinared dibenzo-p-dioxins/furans (PCDD/Fs). Methods: PCDD/Fs concentrations in ambient air ($C_a$, $pg/m^3$) and deposited pine needles ($C_p$, pg/g dry) were analyzed simultaneously from June 1 to December 31. Air samples were taken using two low volume PUF active air samplers with an overall average air volume of approximately $1,200Sm^3$. Pine needles were collected the end of December near the air sampler. PCDD/Fs was analyzed by HRGC/HRMs. Results: A good correlation was shown ($R^2=0.6357$, p=0.0001) between $C_a$ and $C_p$, but a better correlation ($R^2=0.7372$, p<0.0001) existed between the logarithm of octanol-air partitioning coefficient ($LogK_{oa}$) and Log($C_p/C_a$). The average PCDD/Fs sampling rates from air to pine needles were 0.045($0.018-0.185m^3/day-g\;dry$). Conclusion: It was found that pine needles can be used as PAS for atmospheric PCDD/Fs, and they are especially suitable for long time PAS compared to PUF disk PAS.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.