Evaluation of Passive Sampler as a Useful Tool for Environmental Education (환경교육의 도구로서 간이 측정기의 활용에 관한 연구)

  • 전의찬;송민종
    • Hwankyungkyoyuk
    • /
    • v.11 no.2
    • /
    • pp.252-261
    • /
    • 1998
  • Since 1980's during which environmental pollution became serious enough to urge various types of environmental educations in many areas. But, most emphasis has been put on theoretical education. Even field education training mostly focused on water pollution. Therefore, simple air pollution monitoring system was needed for better field education in air pollution. In this study, we evaluated Passive Sampler as an useful tool for teaching air pollution in field. Students have found passive sampler very effective tool. Recent comparative study of auto-monitoring and passive sampler networks suggested a potential use of passive sampler as an useful tool for environmental education. In this study, the correlation between two sets of values appears very high judging from the regression slope of 0.92 and correlation coefficient of 0.91 However, inexpensive Passive sampler with easy-to-operate colorimeter, has not been used in environmental education partially because large scale fluctuation in time and space characteristic to air pollution has been overlooked so that the sampler has not been tested for an effective educational tool. Passive sampler certainly deserves further in depth research as an effective air monitoring system, and better attention to its usefulness to teach students and public.

  • PDF

Air Quality Evaluation with Passive Samplers for Large Cities (Passive Sampler를 이용한 대도시의 대기질 평가)

  • Jeon, Eui-Chan;Kim, Shin-Do;Choi, Kum-Chan
    • Journal of Environmental Impact Assessment
    • /
    • v.7 no.2
    • /
    • pp.83-88
    • /
    • 1998
  • Filter badge type sampler has not been widely used to evaluate air quality over large cities in Korea while it can be successfully used for multi-point sampling and analysis. We evaluated the passive sampler as a new tool to monitor air quality over large cities. We latticed Metropolitan Seoul into $2{\times}2Km$ to give 136 points. $NO_2$ concentrations were measured at all the points in the Spring and Summer of 1997. According to the passive sampler data, natural green zones generally recorded lower $NO_2$ concentrations than major streets and traffic congestion areas. Passive samplers with abundant 136 points gave more detailed picture of $NO_2$ distribution while auto-monitoring network did not clearly provide the characteristics of local land use. Also, passive samplers gave 15% higher values than auto-monitoring network. The correlation between the two values appears very high judging from the regression slope of 0.92 and correlation coefficient of 0.91. This study clearly demonstrates the effectiveness of the passive sampler as a tool to monitor air quality over large cities.

  • PDF

A Study on the Performance of a Short Term Ozone Passive Sampler in Experimental Chamber (단기 측정용 오존 간이 측정기의 실험 챔버 내에서 성능에 관한 연구)

  • Jeong, Sang-Jin
    • Journal of Environmental Science International
    • /
    • v.16 no.8
    • /
    • pp.1001-1009
    • /
    • 2007
  • Passive sampler is a simple and cost-effective measuring equipment for ambient and indoor air pollution. We studied the performance of a short term (1 hour mean concentration) ozone passive sampler which was coated with a colorant (indigo carmine) to a filter substrate. Acetone and sulfamic acid added ozone passive sampler was investigated to measure short term mean ozone concentration. Ozone response and interference of criteria air pollutant($SO_2,\;NO_2$, CO) on a short term ozone passive sampler was tested through experimental chamber. The results show sulfamic acid added passive ozone sampler have good response in ozone exposure. Interference of $NO_2$ gas is larger than other two criteria gases.

A Study on Ozone Passive Sampler (II) -Interference and Field Application (오존간이 측정기에 대한 연구(II)-간섭현상 및 현장 적용성)

  • Jeong, Sang-Jin;Yang, Hee-Jun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.904-911
    • /
    • 2006
  • Passive sampler is simple and inexpensive measuring equipment for air pollution. In this study we developed colorimetric ozone passive sampler which was coated a colorimetric reagent to a filter substrate. Interference of criteria all pollutant ($SO_2,\;NO_2,\;CO$) on ozone passive sampler was investigated through experimental chamber. Field measurement of developed ozone passive samper was compared automatic sampler result in Suwon area. The results shows interference of $SO_2$ gas is larger than other gases. Developed passive sampler can be roughly applicable to wind speed range from 0.8 to 3.3 m/s, temperature range from 3.9 to $27.5^{\circ}C$ and relative humidity range from 48 to 84%.

Development of a Passive Sampler using a Fluorescence Material for the Ambient Ozone (형광물질을 이용한 대기 중 오존 Passive Sampler의 개발)

  • 임봉빈;정의석;김선태
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.4
    • /
    • pp.483-491
    • /
    • 2004
  • The purpose of this study is to develop an ozone passive sampler and to evaluate its performance p-Acetamidophenol using as the reagent for ozone reacts specifically with the ambient ozone to produce a fluorescence material (p-acetamidopheonl dimer). The volume of absorbent solution and the extraction time determined at suitable conditions for measuring ozone were 100$\mu$L and 60 min, respectively. The changes of fluorescence were observed with incresing the storage period of passive samplers in ambient air. but the cool storage in a refrigerator did not remarkably influence the increase of fluorescence. The measurement for the precision oi the passive sampling was carried out with duplicate measurement of passive samplers. The intra-class correlation coefficients of passive samplers using dry and wet filters were 0.992 and 0.962, respectively The results from field validation tests indicated practical agreement (dry filter: r=0.963, wet filter: r=0.995) between the passive sampler and an UV photometric $O_3$ analyzer. The limit of quantification of ozone passive samplers with sampling time of 8 hr (wet filter) and 24 hr (dry filter) were 8.0 ppb and 2.7 ppb, respectively.

Estimation of PCBs Concentrations in Ambient Air Using Pine Needles as a Passive Air Sampler (PAS) (소나무잎을 Passive Air Sampler(PAS)로 이용하여 대기 중 PCBs 농도 추정)

  • Chun, Man-Young
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.4
    • /
    • pp.360-368
    • /
    • 2012
  • Objective: This study was carried out to use pine needles as a passive air sampler (PAS) of atmospheric Polychlorinated Biphenyls (PCBs). Methods: PCB concentrations in ambient air ($C_a$, ng/$m^3$) and deposited on pine needles ($C_p$, ng/g dry) were analyzed simultaneously from June 1 to December 31. Air samples were taken using a low volume PUF active air sampler and the overall average air volume was about 900-1,000 $m^3$. Pine needles were collected at the end of August and December near the air sampler. Results: $C_a$ were higher at higher air temperature and lower chlorinated PCB congeners, but $C_p$ showed irregular distribution. The average PCB sampling rates from air to pine needles were 0.116 (0.002-0.389) $m^3$/day - g dry. Conclusions: A poor correlation was shown between $C_a$ and $C_p$. However, a good correlation was shown between the logarithm of octanol-air partitioning coefficient ($logK_{oa}$) and log ($C_p/C_a$), and the interrelation was better with longer sampling time (June to December) than shorter sampling time (June to August). The average PCB sampling rates from air to pine needles were the lowest with respect to PUF disk, XAD-2 resin and semipermeable membrane devices (SPMDs) PAS. The average ratio ($C_{a-calc}/C_{a-meas}$) of calculated ($C_{a-calc}$) and measured ($C_{a-meas}$) PCB concentration was 0.69 with a shorter sampling time and 1.24 with a longer, so $C_{a-calc}$ was close to $C_{a-meas}$. It was found that pine needles can be used as PAS of atmospheric PCBs, and are especially suitable for long-time PAS.

Estimation of Atmospheric PAH Concentrations and Sources at Several Sites Using Pine Needles as a Passive Air Sampler (소나무잎을 Passive Air Sampler로 이용하여 지역별 대기 중 다환방향족 탄화수소의 농도 및 발생원 추정)

  • Chun, Man-Young
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.1
    • /
    • pp.38-46
    • /
    • 2014
  • Objectives: This study was carried out in order to estimate atmospheric polycyclic aromatic hydrocarbon (PAH) concentrations and sources using pine needles as a passive air sampler (PAS) in urban (Pyeongtaek), semirural (Anseong) and rural (Jincheon) sites. Methods: One-year-old pine needles were collected for analysis of their PAH concentrations ($C_{p,n}g/g$ dry) at the end of December. PAHs concentrations in the ambient air ($C_a$, $ng/m^3$) were calculated with a $Log(C_p/C_a)-LogK_{oa}$ correlational equation. Results: PAHs concentrations in ambient air ($C_a$) were high, in the order of urban ($114.03ng/m^3$), semirural ($105.17ng/m^3$) and rural ($61.91ng/m^3$) sites. However, distributions of PAH isomer concentrations were very similar. PAHs of which molecular weight is smaller than 228.30 (AcPy, Acp, Flu, Phen, Ant, Flt, Pyr, BaA, Chry) made up most of the PAHs in the ambient air (96.6-98.5%). Conclusion: At urban, semirural and rural sites, it was concluded that the main source of PAHs in the ambient air ratio of each PAH isomer concentration was cars, especially diesel vehicles.

The measurement of NH$_3$ spatial distribution around the landfill site using the passive sampler (Passive sampler를 활용한 매립지 내ㆍ외부의 암모니아 공간분포 측정)

  • 이범진;김학민;김선태;정의석
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.319-320
    • /
    • 2001
  • Passive sampler는 현장에서 제약 없이 사용할 수 있다는 간편성과 그 측정결과의 정확성, 정밀성에 대하여 입증된 바 있는 측정도구로써 대기질 측정 및 모니터링뿐만 아니라 최근에는 대기확산모델의 검증자료로도 활용되고 있다(김선태, 2001). 이러한 측정방법은 국내의 경우 1992년 이후 한정적으로 사용되었으나, 최근에는 국내뿐 아니라 해외에서도 passive sampler를 사용하는 사례가 증가하고 있으며, UNEP에서도 다양한 목적으로의 활용성을 언급하고 있다(UNEP, 1994). (중략)

  • PDF

Estimation of PCDD/Fs Concentrations in Ambient Air Using Pine Needles as a Passive Air Sampler (PAS) (소나무 잎을 PAS로 이용하여 대기 중 PCDD/Fs 농도 추정)

  • Chun, Man-Young
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.2
    • /
    • pp.116-125
    • /
    • 2015
  • Objective: This study was carried out to use pine needles as a passive air sampler (PAS) for atmospheric polychlorinared dibenzo-p-dioxins/furans (PCDD/Fs). Methods: PCDD/Fs concentrations in ambient air ($C_a$, $pg/m^3$) and deposited pine needles ($C_p$, pg/g dry) were analyzed simultaneously from June 1 to December 31. Air samples were taken using two low volume PUF active air samplers with an overall average air volume of approximately $1,200Sm^3$. Pine needles were collected the end of December near the air sampler. PCDD/Fs was analyzed by HRGC/HRMs. Results: A good correlation was shown ($R^2=0.6357$, p=0.0001) between $C_a$ and $C_p$, but a better correlation ($R^2=0.7372$, p<0.0001) existed between the logarithm of octanol-air partitioning coefficient ($LogK_{oa}$) and Log($C_p/C_a$). The average PCDD/Fs sampling rates from air to pine needles were 0.045($0.018-0.185m^3/day-g\;dry$). Conclusion: It was found that pine needles can be used as PAS for atmospheric PCDD/Fs, and they are especially suitable for long time PAS compared to PUF disk PAS.