Browse > Article
http://dx.doi.org/10.5322/JES.2007.16.8.1001

A Study on the Performance of a Short Term Ozone Passive Sampler in Experimental Chamber  

Jeong, Sang-Jin (Department of Env. Eng. Kyonggi University)
Publication Information
Journal of Environmental Science International / v.16, no.8, 2007 , pp. 1001-1009 More about this Journal
Abstract
Passive sampler is a simple and cost-effective measuring equipment for ambient and indoor air pollution. We studied the performance of a short term (1 hour mean concentration) ozone passive sampler which was coated with a colorant (indigo carmine) to a filter substrate. Acetone and sulfamic acid added ozone passive sampler was investigated to measure short term mean ozone concentration. Ozone response and interference of criteria air pollutant($SO_2,\;NO_2$, CO) on a short term ozone passive sampler was tested through experimental chamber. The results show sulfamic acid added passive ozone sampler have good response in ozone exposure. Interference of $NO_2$ gas is larger than other two criteria gases.
Keywords
Short term passive sampler; Ozone; Interference; Indigo carmine;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 정상진, 2002, 오존 간이측정기에 대한 연구(I)- 필터의 민감도, 한국대기환경학회지, 18(5), 383-391
2 Kizil M. S., Peterson J., English W., 2001, The effect of coal particle size on colorimetric analysis of roadway dust, J. of Loss Prevention in the process industries, 14, 387-394   DOI   ScienceOn
3 Shan Y., Normand N. D., Peleg M., 1997, Estimation of the surface concentration of adhered particles by color imaging, Powder Technology, 92, 147-153   DOI   ScienceOn
4 장재철, 2004, 색도법을 이용한 대기중 HCHO 측정법에 대한 연구, 석사학위논문, 환경공학과, 경기대학교. 수원
5 정상진, 양희준, 2006, 오존간이측정기에 대한 연구(II)-간섭현상 및 현장 적용성, 한국대기환경학회지, 22(6), 904-911   과학기술학회마을
6 정상진, 2001, 오존 간이측정기의 챔버내 성능평가에 관한 연구, 경기대학교 산업기술종합연구소 논문집 , 22, 47-56
7 동화기술편집부, 2005, 대기오염.소음.진동 공정시험방법, 동화기술, 894pp
8 Kim S. T., Maeda Y., 2003, The Study on the effects of air pollution on the material damages in northeast Asia, J. Korean Society for Armospheric Environment, 19(E2), 51-61
9 김선규, 임봉빈, 정의석, 김선태, 2006, 대기중 이산화질소의 단기 측정을 위한 뱃지형 passive sampler의 개발 및 평가, 한국대기환경학회지, 22(1), 117-126   과학기술학회마을
10 김선태, 임봉빈, 정재호, 2005, 4-Amino-3- hydrazino-5-mercapto-1,2,4-triazole을 이용한 실내 포름알데히드 측정용 passive sampler 개발, 한국대기환경학회지, 21(6), 593-603   과학기술학회마을
11 모세영, 1996, 대기오염공학실험, 동화기술, 426pp
12 천만영, 강공언, 김희강, 1992, $NO_{2}$ 간이포집기의 정도에 관한 연구, 한국대기보전학회지, 8(1), 93-99
13 Krupa S. V., Legge A. H., 2000, Passive sampling of ambient, gaseous air pollutants: an assessment from an ecological perspective, Environmental Pollution, 107, 31-45   DOI   ScienceOn
14 정상진, 장재철, 2004, Methyl Yellow와 Methyl Orange 지시약을 이용한 실내공기중의 포름알데히드 간이측정기에 대한 연구, 한국대기환경학회지, 20(6), 793-801
15 우정현, 김선태, 김정욱, 1997, 수동측정기에 의한 대기오염 자동측정망의 지역대표성 조사 및 보완방법에 대한 기초연구, 한국대기보전학회지, 13(6), 415-426
16 최성득, 장윤석, 2005, Passive Air Sampler를 이용한 잔류성 유기오염물질의 대기 모니터링, 한국대기환경학회지, 21(5), 481-494   과학기술학회마을
17 양원호, 이기영, 백도명, 2000, 실내 및 실외공기 중 이산화질소 개인 노출량 측정을 위한 수동식 시료채취기의 성능평가, 한국대기환경학회지, 16(6), 625-631
18 Kim S. T., Kim H. S., 2002, The Nationwide $NO_{2}$ Monitering with Passive Sampler in Korea, J. Korean Society for Armospheric Environment, 18(E2), 69-77
19 Grojean D., Hisham M. W., 1992, A passive sampler for atmospheric ozone, Journal of Air & Waste Management Association, 42, 169-173   DOI   ScienceOn
20 엄봉빈, 정의석, 김선태, 2004, 형광물질을 이용한 대기중 오존 Passive sampler의 개발, 한국대기환경학회지, 20(4), 483-491