Adaptive Standby Mode Scheduling Method Based on Analysis of Activation Pattern for Improving User Experience of Low-Power Set-Top Boxes

  • Park, Hyunho;Kim, Junghak;Jung, Eui-Suk;Lee, Hyunwoo;Lee, Yong-Tae
    • ETRI Journal
    • /
    • v.38 no.5
    • /
    • pp.885-895
    • /
    • 2016
  • The lowest power mode (passive-standby mode) was proposed for reducing the power consumption of set-top boxes in a standby state when not receiving content. However, low-power set-top boxes equipped with the lowest power mode have been rarely commercialized because of their low-quality user experience. In the lowest power mode, they deactivates almost all of operational modules and processes, and thus require dozens of seconds for activation latency (that is, the latency for activating all modules of the set-top boxes in a standby state). They are not even updated in a standby state because they deactivate their network interfaces in a standby state. This paper proposes an adaptive standby mode scheduling method for improving the user experience of such boxes. Set-top boxes using the proposed method can analyze the activation pattern and find the frequently used time period (that is, when the set-top boxes are frequently activated). They prepare for their activation during this frequently used time period, thereby reducing the activation latency and enabling their update in a standby state.

A Development of Standby-power supporting Home-Network Gateway (홈게이트웨이 대기전력 절감기술 연구)

  • Kim, Yong-Ho;Lee, Sang-Hak;Kim, Dae-Hwan
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.115-116
    • /
    • 2009
  • Home-network gateway always powered on, while network data is not transferred. And the Power consumption of networked electric devices are greatly increased, to support higher speed data transfer. To reduce the power consumption of networked electric devices, some ideas were proposed. Such as ALR, Proxying, Subset-PHY. In this paper we propose a scheme to reduce power consumption of Home-Network Gateway. Proposed Home-network Gateway architecture consumes less than 1W in passive standby mode.

  • PDF

A Study on the Smart STB design and operating methods using low-power technology (저전력 기술을 이용한 스마트 셋톱박스 설계 및 운영방법에 관한 연구)

  • Kim, Jeong-Jai;Yun, Jung-Mi;Lee, Sang-Hak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2367-2374
    • /
    • 2011
  • Today's digital broadcasting services based on DVB-SI standard are provided a two-way broadcast. However, using the power of STB if the user does not use a waste of time spent on standby power is becoming a serious problem. Accordingly, for energy savings both at home and abroad to actively promote green policies, but highly functional STB, the internal software to automatically update the appropriate scheduling techniques are not shown, power usage does not meet the standard can. Therefore, In this paper We analyze the current STB technology and the problems, as proper use of power to the standard STB design scheme and the automatic software installation method of operation is presented.

SAFETY ANALYSIS OF INCREASE IN HEAT REMOVAL FROM REACTOR COOLANT SYSTEM WITH INADVERTENT OPERATION OF PASSIVE RESIDUAL HEAT REMOVAL AT NO-LOAD CONDITIONS

  • SHAO, GE;CAO, XUEWU
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.434-442
    • /
    • 2015
  • The advanced passive pressurized water reactor (PWR) is being constructed in China and the passive residual heat removal (PRHR) system was designed to remove the decay heat. During accident scenarios with increase of heat removal from the primary coolant system, the actuation of the PRHR will enhance the cooldown of the primary coolant system. There is a risk of power excursion during the cooldown of the primary coolant system. Therefore, it is necessary to analyze the thermal hydraulic behavior of the reactor coolant system (RCS) at this condition. The advanced passive PWR model, including major components in the RCS, is built by SCDAP/RELAP5 code. The thermal hydraulic behavior of the core is studied for two typical accident sequences with PRHR actuation to investigate the core cooling capability with conservative assumptions, a main steam line break (MSLB) event and inadvertent opening of a steam generator (SG) safety valve event. The results show that the core is ultimately shut down by the boric acid solution delivered by Core Makeup Tank (CMT) injections. The effects of CMT boric acid concentration and the activation delay time on accident consequences are analyzed for MSLB, which shows that there is no consequential damage to the fuel or reactor coolant system in the selected conditions.

Development of Single Phase UPS for Low Cost and High Performance (염가형 고성능 단상 UPS 개발)

  • Lim, Seung-Beom;Lee, Yun-Ha;Ji, Jun-Keun;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.199-200
    • /
    • 2011
  • Uninterruptible Power Supply(UPS) is largely divided into passive-standby, line-interactive and double-conversion methods. This paper proposes the double-conversion UPS for low cost and high performance. The proposed UPS are composed of PFC, inverter, battery charger and discharger. Finally, the validity of proposed UPS was verified by experiments.

  • PDF

EXPERIMENTAL INVESTIGATIONS RELEVANT FOR HYDROGEN AND FISSION PRODUCT ISSUES RAISED BY THE FUKUSHIMA ACCIDENT

  • GUPTA, SANJEEV
    • Nuclear Engineering and Technology
    • /
    • v.47 no.1
    • /
    • pp.11-25
    • /
    • 2015
  • The accident at Japan's Fukushima Daiichi nuclear power plant in March 2011, caused by an earthquake and a subsequent tsunami, resulted in a failure of the power systems that are needed to cool the reactors at the plant. The accident progression in the absence of heat removal systems caused Units 1-3 to undergo fuel melting. Containment pressurization and hydrogen explosions ultimately resulted in the escape of radioactivity from reactor containments into the atmosphere and ocean. Problems in containment venting operation, leakage from primary containment boundary to the reactor building, improper functioning of standby gas treatment system (SGTS), unmitigated hydrogen accumulation in the reactor building were identified as some of the reasons those added-up in the severity of the accident. The Fukushima accident not only initiated worldwide demand for installation of adequate control and mitigation measures to minimize the potential source term to the environment but also advocated assessment of the existing mitigation systems performance behavior under a wide range of postulated accident scenarios. The uncertainty in estimating the released fraction of the radionuclides due to the Fukushima accident also underlined the need for comprehensive understanding of fission product behavior as a function of the thermal hydraulic conditions and the type of gaseous, aqueous, and solid materials available for interaction, e.g., gas components, decontamination paint, aerosols, and water pools. In the light of the Fukushima accident, additional experimental needs identified for hydrogen and fission product issues need to be investigated in an integrated and optimized way. Additionally, as more and more passive safety systems, such as passive autocatalytic recombiners and filtered containment venting systems are being retrofitted in current reactors and also planned for future reactors, identified hydrogen and fission product issues will need to be coupled with the operation of passive safety systems in phenomena oriented and coupled effects experiments. In the present paper, potential hydrogen and fission product issues raised by the Fukushima accident are discussed. The discussion focuses on hydrogen and fission product behavior inside nuclear power plant containments under severe accident conditions. The relevant experimental investigations conducted in the technical scale containment THAI (thermal hydraulics, hydrogen, aerosols, and iodine) test facility (9.2 m high, 3.2 m in diameter, and $60m^3$ volume) are discussed in the light of the Fukushima accident.

Low Cost and High Performance Single Phase UPS Using a Single-Loop Robust Voltage Controller

  • Ji, Jun-Keun;Ku, Dae-Kwan;Lim, Seung-Beom
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.695-701
    • /
    • 2015
  • Uninterruptible Power Supplies (UPSs) can be largely divided into the passive-standby, line-interactive and double-conversion methods. This paper proposes a double-conversion UPS with a low cost and high performance. This single phase UPS uses a single-loop robust voltage controller and 1-switch voltage doubler strategy PFC. The proposed UPS is composed of a single phase PFC, a half-bridge inverter, a battery charger and a battery discharger. Finally, the validity of proposed UPS was verified by various experimental tests.

Study of Performance Criteria Methodology for Maintenance Effectiveness Monitoring Program for Nuclear Power Plants (원전 정비효과성감시 프로그램의 성능기준설정 방법론 개선)

  • Song, Tae-Young;Yeom, Dong-Un;Hyun, Jin-Woo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.2
    • /
    • pp.26-32
    • /
    • 2012
  • The systems of the nuclear power plant are designed based on the User Requirement Document, and Korea Hydro & Nuclear Power Co. (KHNP) implements preventive maintenance activities to keep the specific design function of the system consistently. To monitor the preventive maintenance effectiveness, KHNP has also developed maintenance effectiveness monitoring (MR) program based on NUMARC 93-01 since 2003, and has implemented the program in all operating plants. Recently, KHNP has upgraded MR programs by reflecting implementing experiences ; reestablishing the performance monitoring level, improving analysis for standby function and performance criteria for passive components, reestablishing the availability performance criteria and the performance criteria for the same type of components. These upgraded MR programs will contribute to enhance safety and improve equipment reliability through monitoring maintenance effectiveness.