• Title/Summary/Keyword: Passed tests

Search Result 148, Processing Time 0.027 seconds

Study on the Validity of Aptitude Test under Rail Safety Act (철도안전법 적성검사 타당성 연구)

  • Kim, You-Cheoun
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1264-1281
    • /
    • 2008
  • Around two years have passed since the beginning of aptitude test required by 2006 Rail Safety Act. At this point, it is necessary to evaluate the validity of the aptitude test. Through this study, the structural system for all the tests would be overviewed, which will show the correlation among each tests or its importance. Also, although it is rough, reliability and validity of the tests would be overviewed by their retest and education materials. This would contribute, in the future, to setting up for the standard of upgrading or integrating the tests.

  • PDF

A Biomechanical Comparative Analysis of the Multi-Radius Total Knee Arthroplastry System for Go up Stair and Go down Stair (계단 오르기와 내리기 동안 다축범위(multi-radius) 무릎인공관절 수술자의 운동역학적 비교분석)

  • Jin, Young-Wan;Yoo, Byung-In;Kawk, Yi-Sub
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.1
    • /
    • pp.31-41
    • /
    • 2006
  • The primary purpose of a TKA is to restore normal knee function Therefore, ideally, a TKA should: (a) maintain the natural leverage of the knee joint muscles to ensure generating adequate knee muscle moments to accomplish daily tasks such as rising from climbing stairs; (b) provide adequate knee joint stability. A 16-channel MyoResearch XP EMG system was used to collect the differential input surface electromyography signals VM, VL, RF, BF, ST during climbing/descending stair tests. A Peak Motion Measurement System was used to collect the kinematic and kinetic data. AKIN-COM Ill isokinetic dynamometer was used for EMG of VM, VL, RF, BF and ST during maximal voluntary contraction. I Quadriceps EMG results for the VM of the passed 1year group limb demonstrated significant less RMS EMG than that of the passed 3year group limb $60^{\circ}-15^{\circ}$ of knee flexion(p<0.05). The VL of the passed 1year group limb also demonstrated significants less RMS EMG than that of the passed 3year group limb from $60^{\circ}-45^{\circ}$ of knee flexion(p<0.05). Similar to the VM and VL, the RF of the passed 1year group limb showed less RMS EMG than that of the passed 3year group limb from $60^{\circ}-30^{\circ}$ do knee flexion(p<0.05). Hamstring EMG results for the BF of the passed 1year group limb demonstrated less RMS EMG than that of the passed 3year group limb from $75^{\circ}-15^{\circ}$ of knee flexion(p<0.05). The passed 1year group limb tended to have less ADD displacement(p<0.071) than that of the passed 3year group limb. There was no significant difference of the ABD displacement between the passed 1year group and the passed 3year group limbs(p<0.73). The passed 3year group used compensatory adaptation movement strategies to compensate for the strength deficit of passed 3year group limbs. The passed 3year group limb also increased the quadriceps muscle activation level to produce more knee extension moment to compensate for the short quadriceps moment arm. The passe 3year group limb might have an unstable knee joint in the medio-Iateral direction during the climbing/descending by showing a tendency of more ADD displacement and greater hamming co-activation EMG than the passed 1year group limbs. The TKA design was not able to help the knee joint to produce adequate knee extension moment with less quadriceps muscle effort. I think that old man needs continuous exercise for muscle strength.

Do Various Respirator Models Fit the Workers in the Norwegian Smelting Industry?

  • Foereland, Solveig;Robertsen, Oeystein;Hegseth, Marit Noest
    • Safety and Health at Work
    • /
    • v.10 no.3
    • /
    • pp.370-376
    • /
    • 2019
  • Background: Respirator fit testing is a method to assess if the respirator provides an adequate face seal for the worker. Methods: Workers from four Norwegian smelters were invited to participate in the study, and 701 respirator fit tests were performed on 127 workers. Fourteen respirator models were included: one FFABE1P3 and 11 FFP3 respirator models produced in one size and two silicone half masks with P3 filters available in three sizes. The workers performed a quantitative fit test according to Health and Safety Executive 282/28 with 5-6 different respirator models, and they rated the respirators based on comfort. Predictors of overall fit factors were explored. Results: The pass rate for all fit tests was 62%, 56% for women, and 63% for men. The silicone respirators had the highest percentage of passed tests (92-100%). The pass rate for the FFP3 models varied from 19-89%, whereas the FFABE1P3 respirator had a pass rate of 36%. Five workers did not pass with any respirators, and 14 passed with all the respirators tested. Only 63% passed the test with the respirator they normally used. The mean comfort score on the scale from 1 to 5 was 3.2. The respirator model was the strongest predictor of the overall fit factor. The other predictors (age, sex, and comfort score) did not improve the fit of the model. Conclusion: There were large differences in how well the different respirator models fitted the Norwegian smelter workers. The results can be useful when choosing which respirators to include in respirator fit testing programs in similar populations.

Use of Duckweed (Lemna gibba) Growth-Inhibition Test to Evaluate the Toxicity of Chromate in Korea (환경독성 평가를 위한 좀개구리밥(Lemna gibba)의 성장저해시험법에 관한 연구)

  • 김은주;이성규
    • Environmental Analysis Health and Toxicology
    • /
    • v.16 no.4
    • /
    • pp.205-209
    • /
    • 2001
  • Lemna gibba was newly cultured and provided for toxicity tests. In this study, the chromate toxicity tests for Lemna gibba were performed according to the OECD Lemna growth inhibition test guideline. The test species was Lemna gibba, and the tests were repeated 5 times. To evaluate the toxicity test results, the average specific growth rate, EC50, 95% confidential limit, and variances were calculated. The test performance was analyzed by the doubling time and test statistics. The average values of EC50 data determined by logistic and linear interpolation curves were 25.9 ppm and 35.4 ppm respectively (by chromate concentration). The doubling time of all controls were below 2.5 day, so all tests passed the criteria for the test performance. This study introduced a new test method, Lemna growth inhibition test, which is provided for the hazard assessment of aquatic environment.

  • PDF

The Influence of Forest Fire Simulation on the Properties of Polymer Insulators

  • Lee, Won-Kyo;Choi, In-Hyuk;Lee, Dong-Il;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.161-164
    • /
    • 2009
  • Forest fire simulation tests were performed with polymer and porcelain insulators at GOCHANG Power Testing Center. These tests consisted of open flames causing a temperature rise of up to $600{\sim}800^{\circ}C$ measured at the insulator surfaces. Mechanical and electrical characteristics such as the specific mechanical load, the low frequency dry flashover voltage and the impulse flashover voltage were analyzed for the polymer insulators before, during and after the simulation tests and then compared to the porcelain insulators. At the end of the fire simulation tests, there was no detrimental deterioration of any of the insulators. All the insulators passed the KEPCO specification criteria. This study showed that the forest fire simulation had no impact on the polymer insulators.

A Study on the reliability analysis of Forest Fire on Polymer Insulators (폴리머 애자의 산불 신뢰성 평가 연구)

  • Lee, Won-Kyo;Choi, In-Hyuk;Hwang, Kab-Cheol;Choi, Han-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.460-461
    • /
    • 2008
  • The forest fire simulation tests were performed with polymer and porcelain insulators at Gochang testing center. These tests consisted of energizing 90 kV at line-to-ground voltage of 154 kV lines and open flame rising up to $600-630^{\circ}C$ as being measured at insulator surface. Mechanical and electrical characteristics such as specific mechanical load, leakage current, low frequency dry flashover voltage and impulse flashover voltage were analyzed for the polymer insulators before, during and after simulation tests compared with porcelain insulators. At the end of fire simulation tests, there was no detrimental deterioration of any insulators. All insulators passed the criteria of KEPCO specification. This study showed that forest fire simulation had no impact on polymer insulators.

  • PDF

Study on the Validity of Aptitude Test under Rail Safety Act (철도안전법 적성검사 적합성 연구)

  • Kim, You-Cheoun;Jeon, Young-Seok
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.2
    • /
    • pp.219-229
    • /
    • 2009
  • Around two years have passed since the beginning of aptitude test required by 2006 Rail Safety Act. At this point, it is necessary to evaluate the validity of the aptitude test. Through this study, the structural system for all the tests would be overviewed, which will show the correlation among each tests or its importance. Also, although it is rough, reliability and validity of the tests would be overviewed by their retest and education materials. This would contribute, in the future, to setting up for the standard of upgrading or integrating the tests.

A Study on the Mix Design of Early Strength Concrete using Admixture (혼화제를 이용한 조강콘크리트 배합설계에 관한 연구)

  • Park, Young-Shin;Nam, Sung-Woo;Park, Jae-Myung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.69-72
    • /
    • 2005
  • In this study, it is contents to application on AE water reducing admixture for high early strength, which reduce to construction period for cost down in construction. In experiment result on the kinds of AE water reducing admixture for concrete strength promotion, when passed 60 minutes, while it was happened on lignin and naphthalene system about $30\∼35\%$ that loss related to slump, slump flow and air, but happened about $8\∼10\%$ on polycarboxylic system. And the result of compressive strength tests, when 32 hours passed in polycarboxylic system than lignin and naphthalene system, was showing an increase of 10$\%$. Accordingly, concrete properties was measured to condition change by the addition amount and curing temperature of polycarboxylic system. The required curing temperature to gain 5MPa of compressive strength, which is capable of side form stripping, must keep more than smallest 12. 5$^{circ}C$ when polycarboxylic system is used. As a result, AE water reducing admixture of polycarboxylic system may apply effectively to high early strength concrete

  • PDF

The Evaluation of Durability Performance in Mortar Curbs Containing Activated Hwangtoh (활성 황토를 혼입한 모르타르 기반 경계석의 내구성능 평가)

  • Kwon, Seung-Jun;Kim, Hyeok-Jung;Yoon, Yong-Sik
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.520-527
    • /
    • 2020
  • Hwangtoh is the rich resource that accounts for about 15.0% of the domestic soil, and can be used as the admixture of concrete with Pozzolan characteristics if activated by rapidly freezing after burning with high temperature. In this study, the mortar curbs containing active hwangtoh were produced, based on the mixture for the mortar curbs sold on the market. The substitution rate of active hwangtoh were considered 10.0% and 25.0%, and the test items were selected to compressive and flexural strength tests, freezing/thawing resistance tests, accelerated carbonation tests, and accelerated chloride diffusion tests. In the results of the mechanical performance, it was showed that the highest strength was evaluated in OPC mixture, and the increase in strength was small by the increase of age, which was believed to be due to the fact that most of the strength in each mixture was created in three days of steam curing. The results of the freezing/thawing tests for 28 aged days showed the reduction rate of compressive strength was 85.0% or higher for all specimen, meeting the criteria presented. The accelerated carbonation tests were carried out on the specimen at 28 days of age, and the results showed that the mortar with active hwangtoh had lower carbonation resistance performance than mortar with OPC. The passed charge of each mixture was assessed in accordance with ASTM C 1202 on 28 and 91 aged days. The OPC mixture had "Low" rate and the mortar with active hwangtoh had "Moderate" rate. So it was thought that the mortar with active hwangtoh had appropriate resistance performance for chloride attack.

The Mechanical Properties of Concrete Using Blended Super Low Heat Cement (혼합형 초저발열 시멘트를 사용한 콘크리트의 물성-현수교 앵커리지 콘크리트 대상-)

  • 송용순;강석화;손명수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.341-344
    • /
    • 1999
  • In the case of the offshore concrete structures like the anchorage block of a suspension bridge of Kwangan Grand Road, there is a need of the concrete which has low heat of hydration and good resistance for sea-water attack. In this study, the blended super low heat cement which satisfies that requirement was developed and several tests were carried out. The concrete using the blended super low heat cement showed lower adiabatic temperature rise than 3$0^{\circ}C$ and good early strength. Also, its passed charge(coulomb) to resist chloride ion penetration was very low.

  • PDF