• Title/Summary/Keyword: Passage number

Search Result 352, Processing Time 0.024 seconds

Heat transfer coefficient measurement in the Blockage channel with Repeated Jet Impingement (반복된 제트 충돌을 갖는 내부 유로의 평균 열전달 계수 측정)

  • Park, Seoung Duck;Lee, Ki Seon;Kim, Sug Bum;Jo, Yong Hwa;Jeon, Chang Soo;Kwak, Jea Su;Huh, Jae-Sung
    • Journal of Aerospace System Engineering
    • /
    • v.2 no.4
    • /
    • pp.7-12
    • /
    • 2008
  • Averaged heat transfer coefficients were measured in a turbine blade internal cooling passage model with three blockage walls. Each blockage wall was equipped with 9 staggered holes or slots in order to create different shaper of repeated jet impingement. The effect of jet shape on the averaged heat transfer coefficient was studied by the copper-thermocouple method and three Reynolds number of 10,000, 20,000, and 30,000 were tested. Results showed that the repeated stagger jets could increase the averaged heat transfer coefficient by at least 9 times compared to the smooth channel cases. Due to the large pressure drop induced by the repeated jet impingement, the thermal performance was less than 1 for all cases and decreased as the Reynolds number increased. Among the tested cases, the widest slot showed the best thermal performance. The measurement results showed that the thermal performance of the heat transfer augmentation by repeated stagger jets could be improved by altering the jet shape, and other shape of impingement jet will be studied in near future.

  • PDF

Scientific Technical Development of Traffic Accident Investigation (교통사고 조사의 과학화 기술개발)

  • Hong, YouSik;Lee, ChaeWoo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.2
    • /
    • pp.35-42
    • /
    • 2008
  • In order to reduce a recent traffic accident, the traffic accident research has been studied using IT technique. But, when running away traffic accident it occurs, it is difficult to find the assault vehicle. In this paper, to solve these problems, if traffic accident will happen, The RFID reader will be able to recognize a license plate number automatically. Moreover, when the traffic accident occurs from the Internet base which uses the PDA the driver traffic accident site data and driver human fact it will be able to transmit in the police station or the insurance company. From the simulation result, it confirms that when passage vehicle speed is low speed above 70% it will be able to recognize the license plate number.

  • PDF

Analysis of Parenting-Friendly Outdoor Environment in Apartment Complexes (아파트단지 옥외공간의 친육아환경 요소에 대한 분석)

  • Kim, Hyo-Jeong;Park, Kyoung-Ok
    • Journal of the Korean housing association
    • /
    • v.28 no.1
    • /
    • pp.95-107
    • /
    • 2017
  • The purpose of the study is to analyze the planning characteristics of outdoor space in apartment complexes in terms of child-care environment. We selected 8 apartment complexes in Cheongju, within three years from construction, of small and medium-sized apartments ($60-85m^2$) where a large number of families with young children are presumed to reside in. As a result of the study, it was found that whereas the factors that can be quantified such as the floor height differences, the angles of ramps, and the number of the rest facilities are excellent, the qualitative part which cannot be easily quantified such as the location and direction of the rest facility and play materials should be improved a lot. And the following improvements were suggested; separating the pedestrian passage from the vehicle road in the main entrance of the complex, utilizing the piloti for infant caring, making the entrance area of apartment safe for pedestrians from vehicles, reallocating resting spaces, redesigning resting spaces safer to infants, building or reallocating existing booths at the stops of kindergarten buses, redesigning the square safer from vehicles with shades, making it possible for guardians to watch infants in playing field from the resting space, allocating natural environments essential for child development.

Influence of the Unsteady Wake on the Flow and Heat Transfer in a Linear Turbine Cascade (비정상 후류가 선형터빈익렬의 유동 및 열전달에 미치는 영향에 관한 연구)

  • Yun, Sun-Hyeon;Sim, Jae-Gyeong;Kim, Dong-Geon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.2
    • /
    • pp.164-170
    • /
    • 2001
  • The influence of unsteady wake on the flow and heat transfer characteristics in a four-vane linear cascade was experimentally investigated. The unsteady wake was generated with four rotating rectangular plates located upstream of the cascade. Tested inlet Reynolds number based on chord length was set to 66,000 by controlling free-stream velocity. A hot-wire anemometer system was employed to measure turbulent velocity components. For the convective heat transfer coefficients measurement on turbine blade surface, thermochromic liquid crystal and gold film Intrex were used. It was found that the unsteady wake enhances the turbulent motion in the cascade passage and accordingly promotes the development and transition of boundary layer. It was found that the heat transfer coefficients on the blade surface increase as the plate rotating speed increases. However, the increasing of heat transfer coefficients is not significant in the case that Strouhal number is higher than 0.503.

Heat Transfer Characteristics in a Leading Edge Cooling Channel of a Turbine Blade with Various Rib Arrangements (터빈 기익 선단부에 설치된 냉각유로에서의 요철 배열에 따른 열전달 특성)

  • Lee, Dong-Hyun;Kim, Kyung-Min;Rhee, Dong-Ho;Cho, Hyung-Hee
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.459-466
    • /
    • 2005
  • The present study investigates the heat transfer characteristics of a triangular channel. Three different rib configurations are tested. The ribs are installed on two sides of the channel. The rib height (e) to channel hydraulic diameter is 0.079 and the rib-to-rib pitch (p) is 8 times of the rib height. The rotation number ranges from 0.0 to 0.1 while the Reynolds number is fixed at 10,000. The copper blocks with heaters are installed on the channel walls to measure the regionally averaged heat transfer coefficients. For the stationary $45^{\circ}$ and $135^{\circ}$ ribbed channels, a pair of counter rotating vortices is induced by the angled rib arrangements, and high heat transfer coefficients are obtained on the regions near the inner wall for the $45^{\circ}$ ribbed channel and near the leading edge for the $90^{\circ}$ ribbed channel. The heat transfer coefficients of angled ribbed channels are changed little with rotation, whereas those of the transverse ribbed channel are changed significantly with rotation.

  • PDF

The Study of Breath Competence Depending on Utterance Condition by Healthy Speakers: a Preliminary Study (발화조건에 따른 정상 성인의 호흡 능력 차이 비교: 예비연구)

  • Lee, In-Ae;Lee, Hye-Eun;Hwang, Young-Jin
    • Phonetics and Speech Sciences
    • /
    • v.4 no.2
    • /
    • pp.115-120
    • /
    • 2012
  • This study sought to compare breath competence in three different utterance conditions when reading a passage aloud, making a spontaneous speech, and singing. We tested 15 normal females (ages averaging $24{\pm}4.4$) and measured breath competence through an objective, aero-mechanical instrument called PAS (Phonatory aerodynamic system, model 6600, KAY Electronics, Inc). Breathing sets of inspiration and expiration were measured by breath group number, breath group duration, and the ratio of inspiration to expiration. The results from this study led us to the following conclusion: The breath group number and the breath group duration showed no significant difference. However, the only variance that we could find was in the ratio of inspiration and expiration. In significantly different speech patterns, singing resulted in the most varied ratio of inspiration and expiration, followed by reading a text aloud, and spontaneous speech. The average frequency rates and maximum intensity levels varied with regards to varying utterance conditions. This thus shows that breath competence and phonation competence have a closely interrelated relationship.

A Study of design Asyn communication eletronic cash system using PSTN / leased line (PSTN/전용선을 이용한 ATM 통신방식의 전자지불 시스템 설계연구)

  • Kim, W.Y.;Hong, J.H.;Jung, J.H.;Song, G.Y.;Song, W.J.;Jung, Y.H.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2353-2356
    • /
    • 2002
  • The increase of vehicles stagnations leads to the increasing attention to the way customers pay and a large number of projects on electronic cash system. Tranport system is comprised of a number of advanced technologies, including information processing, communications, control, and electronics. Recently many research on a system which provides contact in order to protect driver's vehicle passage have been carried out. And some potential problems from that system are being reviewed by electronic cash system. In this papers, we suggest RF protocol developing technology using the concept of electronic cash. ATM electronic cash developing is consist of component of pre-developed coin throw, integration of component using its, and production of more requirement-satisfactory ITS solution. Result increase 15$\sim$40% pre-type vehicles stagnations. Especially, we expect this proposed concept would be well adapted to our national environments.

  • PDF

Heat Transfer Enhancement in a Divergent Passage with 30° Inclined Ribs (30° 경사 리브가 있는 확대 채널 통로 내의 열전달 증가)

  • Lee, Myung Sung;Ahn, Soo Whan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.8
    • /
    • pp.401-407
    • /
    • 2017
  • The effect of different rib geometries such as V-shaped continuous (case A), parallel broken (case B), and V-shaped broken (case C) ribs on local heat transfer distributions and pressure drops in a divergent channel with $30^{\circ}$ inclined ribs on one wall or two walls was investigated for Reynolds numbers from 22,000 to 75,000. Top and bottom walls were insulated; two side walls were uniformly heated in the divergent channel. Heated walls were composed of 10 isolated coper sections and length-to-outlet hydraulic diameter ratio of 10. Rib height-to-outlet hydraulic diameter ratio was 0.1, and rib pitch-to-height ratio equaled 10. Results revealed that V-shaped continuous rib (case A) produced approximately 1.4 times higher average Nussselt number than in the parallel broken rib (case B), and V-shaped broken rib (case C) in the channel with two ribbed walls at Re = 54,000.

Medical Treatment Service for the Housing Welfare of Elderly People- Laying stress on Aging in Place concept - (노인주거복지 향상을 위한 의료서비스 지원방안 연구 - Aging in Place 개념을 중심으로 -)

  • Lee, Joon-Min;Park, Nam-Hee;Shin, Hwa-Kyoung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.367-370
    • /
    • 2005
  • Offer of medical treatment service for recovery or preservation of physical spiritual function of elderly people by sudden population graying developing is essential. Therefore, according to increase of elderly's medical treatment demand, medical treatment service request is augmented. Number of medical treatment service utilization wishes to grope medical treatment service support way for elderly residing cloth elevation laying stress on elderly's Aging in Place in increase trend in this research. If decide, is as following : First, national hospital and public health center were concentrated most on Seoul and kyonggi, and there were many hospitals to south of a river nine, Songpagu, Seochogu, and public health center was expose that is one by one to each nine. Second, in the case of Seoul, elderly population ratio was expose that comparatively high Yeongdeungpo, Chongno, Yongsan, west passage nine is few hospital number relatively in elderly's residential area. Third, need that establish elderly full text clinic on part of general hospital or university hospital equipment. Fourth, must do so that can use access as is easy little more in local community to all elderly who need medical treatment service of visit nursing, visit medical examination and treatment etc.. that consist in present public health center.

  • PDF

Status, Protection, and Management of Bird Community in Mt. Nam Area (남산 지역 조류 군집의 서식 현황과 보호 및 관리방안)

  • 이우신;조기현;임신재
    • The Korean Journal of Ecology
    • /
    • v.21 no.5_3
    • /
    • pp.665-673
    • /
    • 1998
  • This study was conducted to clarified the relationship between bird community and forest structure and present the counterplan for protection and management of bird community from February 1993 to July 1995 at deciduous and coniferous forest within Mt. Nam area, Seoul, Korea. DBH distribution has not significant differences in each study site. Deciduous forest had more foliage coverage in all layers than coniferous forest. Total 41 species of birds, which were 16 species of resident, 14 species of summer visitor, 4 species of winter visitor, and 7 species of passage migrant were recrded in two study sites. Leaf use rate of birds was increased the increase of coverage. The number of breeding species and pairs, breeding density, and diversity index were greater in deciduous forest than coniferous forest. The number of species and pairs on bush-nesting and foraging guild were greater than other guilds. And the nuber of species and pairs on hole nesting guild were the fewest in nesting guild. Use rate of artificial nests for improvement of habitat quality was greater in coniferous forest than deciduous forest. Maintenance of bush layer, increase of coverage and leaf layer diversity, supply of artificial nests, management of large trees, and control of natural enemy were necessary for protection and management of bird community in Mt. nam area.

  • PDF