• Title/Summary/Keyword: Pass Band

Search Result 963, Processing Time 0.032 seconds

A Miniaturized 2-pole Bandpass Filter with Attenuation Poles (감쇄극을 갖는 소형화된 2단 대역 통과 여파기)

  • Kim, Chul-Soo;Lim, Jong-Sik;Kim, Jong-Hwa;Ahn, Dal
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.6
    • /
    • pp.554-559
    • /
    • 2004
  • A novel miniaturized 2-pole band pass filter(BPF) is proposed and it has an overlapped hairpin and slot structure on the upper and bottom plane of microstrip lines. Due to the overlapped structure of a hairpin and a slot, the size of the proposed BPF is quite smaller than that of a general BPF having coupled lines. The size of the proposed BPF is reduced to 33 % comparing with the conventional λ/4 coupled BPF. The attenuation is improved by controlling the attenuation poles properly using the proposed structure. The proposed 2-pole BPF is fabricated with a narrow bandwidth(69 ㎒) at center frequency, 1.9 ㎓ which is difficult to make that narrow bandwidth in the conventional coupled lines due to impractical spacing. The design method in this paper can be applied to the design of other microwave circuits to reduce the size and improve the performances.

Modified Microstrip Filters Improving the Suppression Performance of Harmonic Signals (고조파 감쇠특성을 향상시킨 변형된 마이크로스트립 여파기)

  • 김봉수;이재욱;송명선
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.10
    • /
    • pp.1054-1060
    • /
    • 2002
  • In this paper, a new parallel-coupled-line microstrip BPF(BandPass Filter) improving the suppression performance of 2nd harmonic signals is studied. Using the consecutive pattern in coupled-line, the desired passband performance is improved and harmonic passband signal is rejected. Recalculation of classical filter design parameters(space-gap between lines, line widths and lengths) is not required. That is, after using the classical design methodology for parellel-coupled-line BPF, new filters can be easily realized by inserting periodic patterns in coupled-line. To investigate the validity of this novel technique, order-3 Butterworth BPF centered at 2.5 GHz with a 10 % FBW(Fractional Bandwidth) and order-5 Chebyshev BPF centered at 10 GHz with a 15 % FBW were used. When five and three square grooves are used, over 30 dB harmonic suppression at 2nd harmonic is achieved in simulation and experiment.

Measurements and Statistical Modeling of Ignition Noise from Vehicle (자동차 점화계통에서 발생된 전자파 잡음의 측정 및 통계적 모형)

  • 김종호;윤현보;백락준;우종우
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.4
    • /
    • pp.390-402
    • /
    • 1997
  • The ignition noises from the vehicle are measured and the measurement data are statistically treated for modeling. The low-noise amplifier and band-pass filter are added between the receiver and the three axes antenna for low noise level measurement and the APD and PSD are measured in 800 MHz frequency range. The measured APD curves can be expressed in terms of sensitivity study of each model through 3(class A) or 6(Class B) parameters variation, and these optimal parameter can easily be calculated by using the Composite Approximation Algorithm. The selected APD parameter can be used for making the Data Base EM-environments and also applied to determine the output and sensitivity margin for the transmitter and receiver. 'Digital microwave transmission systems are equipped with equalizer against fading during multipath fading. In this paper, we proposed variable reference tap position equalizer that varies the reference tap according to fading type to archive better performance. We got the perf?mance improvement about 4~5 dB in MP condition and 2~3 dB in NMP condition from simulation results.

  • PDF

Instrumentation and system identification of a typical school building in Istanbul

  • Bakir, Pelin Gundes
    • Structural Engineering and Mechanics
    • /
    • v.43 no.2
    • /
    • pp.179-197
    • /
    • 2012
  • This study presents the findings of the structural health monitoring and the real time system identification of one of the first large scale building instrumentations in Turkey for earthquake safety. Within this context, a thorough review of steps in the instrumentation, monitoring is presented and seismic performance evaluation of structures using both nonlinear pushover and nonlinear dynamic time history analysis is carried out. The sensor locations are determined using the optimal sensor placement techniques used in NASA for on orbit modal identification of large space structures. System identification is carried out via the stochastic subspace technique. The results of the study show that under ambient vibrations, stocky buildings can be substantially stiffer than what is predicted by the finite element models due to the presence of a large number of partitioning walls. However, in a severe earthquake, it will not be safe to rely on this resistance due to the fact that once the partitioning walls crack, the bare frame contributes to the lateral stiffness of the building alone. Consequently, the periods obtained from system identification will be closer to those obtained from the FE analysis. A technique to control the validity of the proportional damping assumption is employed that checks the presence of phase difference in displacements of different stories obtained from band pass filtered records and it is confirmed that the "proportional damping assumption" is valid for this structure. Two different techniques are implemented for identifying the influence of the soil structure interaction. The first technique uses the transfer function between the roof and the basement in both directions. The second technique uses a pre-whitening filter on the data obtained from both the basement and the roof. Subsequently the impulse response function is computed from the scaled cross correlation between the input and the output. The overall results showed that the structure will satisfy the life safety performance level in a future earthquake but some soil structure interaction effects should be expected in the North South direction.

Align-free Micro-optic Mach-Zehnder Interferometric Filter (정렬에 무관한 마이크로옵틱 마하젠더 간섭계형 필터)

  • Lee, Jong-Hoon;Kim, Hyun-Deok;Song, Jae-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.3
    • /
    • pp.285-289
    • /
    • 2006
  • A novel alignment-free micro-optic MZI filter has been demonstrated. The filter is composed of two fiber-pigtailed collimators and a beam-splittingplate with a periodically etched stripe pattern. We fabricated the plate through a standard lithographic formulation process by using a pyrex substrate glass with SU-8 resist coating on its one of the surfaces. The maximum insertion loss of the implemented filter was less than 2 dB over 1000 nm to 1600 nm and the extinction ratio was larger than 33 dB. The measured PDL within the 3-dB pass band of the filter was less than 0.15dB and the maximum extinction ratio variation was less than 2 dB even when the worst alignment error occured.

Effects of Box Color and Precision Demand on the Muscles' Recruitment Pattern in Repetitive Lifting Tasks (대칭형 들기 작업에서 사회심리적 요인이 근육 동원 형태에 미치는 영향 분석)

  • Song, Young-Woong;Lee, Wook-Gee;Kim, Sang-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.3
    • /
    • pp.79-85
    • /
    • 2009
  • In this study, the effects of psychosocial stress (box color and precision demand) on muscle activity were evaluated in laboratory setting. Eight subjects performed sagittally symmetric lifting tasks. Box color (yellow, black), precision demand (yes, no), and box weight (5%MVC, 10%MVC, 15 %MVC) were varied and surface EMG signals from seven muscles(medial deltoid right, biceps brachii right, lateral triceps right, latissimus dorsi right, erector spinae right, external oblique right, internal oblique right) were recorded. EMG signals were band-pass filtered($10{\sim}400\;Hz$), rectified, RMS smoothed and normalized (NEMG). Analysis of variance tests were conducted on the total NEMG (TNEMG: the sum of the seven muscles' NEMGs) and on the individual muscle's NEMGs. Box color had no effect on the TNEMG and on the seven muscles activities(p>0.05). When precision demand was required at the end point of lifts, the mean NEMG showed higher values than no precision demand conditions: TNEMG (14% increase) and medial deltoid(40% increase), biceps brachii(10% increase), lateral triceps(26% increase), latissimus dorsi(25% increase) muscles. Those increases showed more conspicuous as the box weight increased in the muscles of medial deltoid, lateral triceps, and latissimus dorsi.

The Design of Ring Resonator with Considering Effect of Coupling Gap (결합 갭의 영향을 고려한 링 공진기의 설계)

  • Oh, Teresa;Kim, Heung-Soo
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.8
    • /
    • pp.27-35
    • /
    • 1999
  • A radius of ring resonator is determined by the resonant frequency. Resonant frequencies of resonators with the circumference which is integer times of wave length are not same the expected. In this paper, we suggest the design method of a ring resonator with coupling gap, which has the resonant frequency of desire. The equation which can make reduction of the radius of the resonators depending on the gap space is derived by the method of transmission line analysis. The criterion is suggested to determine the radius of the resonator in accordance with relative permittivity. A ring resonator by the proposed method is as small as one-third of basic ring in size and it has the resonant frequency of desire. T-type coupling line is designed to obtain large attenuation of $S_{11}$ at pass-band. These coupling line capacitances are very lower than the gap capacitances, it does not affect the resonant frequency.

  • PDF

Analog Front-End Circuit Design for Bio-Potential Measurement (생체신호 측정을 위한 아날로그 전단 부 회로 설계)

  • Lim, Shin-Il
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.130-137
    • /
    • 2013
  • This paper presents analog front-end(AFE) circuits for bio-potential measurement. The proposed AFE is composed of IA(instrument amplifier), BPF(band-pass filter), VGA(variable gain amplifier) and SAR(successive approximation register) type ADC. The low gm(LGM) circuits with current division technique and Miller capacitance with high gain amplifier enable IA to implement on-chip AC-coupling without external passive components. Spilt capacitor array with capacitor division technique and asynchronous control make the 12-b ADC with low power consumption and small die area. The total current consumption of proposed AFE is 6.3uA at 1.8V.

Design of a 5.8 GHz Narrow Band-pass Filter with Harmonics Suppression (고조파가 억제된 5.8 GHz 협대역 대역통과 여파기)

  • Yoon, Ki-Cheol;Lee, Jong-Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.2A
    • /
    • pp.167-173
    • /
    • 2008
  • In this paper, the flexible narrow bandpass filters (BPFs) with ${\lambda}$g/4 short and ${\lambda}$g/2 open stubs by microstrip line on duroid substrate are suggested. These BPFs with narrow bandwidth show flexible bandwidth with variation of the position of the stubs using the Qe (external quality factor) without changing the impedance value at microwave range. On the other hand, by replacing the series quarter-wavelength connecting lines with the equivalent T-shaped line of bandstop filter(BSF), the compact stub bandpass filter with harmonics suppression can be realized. The BPF with ${\lambda}$g/4 short stubs shows the insertion loss of 2.1 dB and the return loss of 18 dB and BPF with ${\lambda}$g/2 open stubs shows the insertion loss of 1.2 dB and the return loss of 21.9 dB at the center frequency of 5.8 GHz and the bandwidth of 10 %.

Experimental Study on Heat Release in a Lean Premixed Dump Combustor Using OH Chemiluminescence Images (희박 예혼합 덤프 연소기에서 OH 자발광을 이용한 열 방출에 관한 실험적 연구)

  • Moon, Gun-Feel;Lee, Jong-Ho;Jeon, Chung-Hwan;Chang, Young-June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1368-1375
    • /
    • 2004
  • Measurements of OH chemiluminescence in an atmospheric pressure, laboratory-scale dump combustor at equivalence ratios ranging from 0.63 to 0.89 were reported. The signal from the first electronically excited state of OH to ground state was detected through a band-pass filter with an ICCD. The objectives of this study are two: One is to see the effects of equivalence ratio on global heat release rate and local Rayleigh index distribution. To get the local Rayleigh index distribution, the line-of-sight images were inverted by tomographic method, such as Abel do-convolution. Another aim is to investigate the validity of using OH chemiluminescence acquired with an ICCD as a qualitative measure of local heat release. For constant inlet velocity and temperature, the overall intensities of OH emission acquired at different equivalence ratio showed periodic and higher value at high equivalence ratio. OH intensity averaged over one period of pressure increased exponentially with equivalence ratio. Local Rayleigh index distribution clearly showed the region of amplifying or damping the combustion instability as equivalence ratio increased. It could provide an information/insights on active control such as secondary fuel injection. Finally, local heat release rate derived from reconstructed OH images were presented fur typical locations.