• Title/Summary/Keyword: Particulate loading

Search Result 87, Processing Time 0.022 seconds

Index of Organic Matter in Stream and Lake (하천·호소의 유기물 지표 평가)

  • Yu, Soon Ju;Hwang, Jong Yeon;Yoon, Young Sam;Cheon, Se Uk;Han, Eui Jung
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.1
    • /
    • pp.81-92
    • /
    • 1999
  • This study discussed the appropriateness of organic matter indexes such as biochemical oxygen demand(BOD) and chemical oxygen demand with potassium permanganate($COD_{Mn}$) in water quality environmental standard of streams and lakes and the applicability of the items to water quality environmental standard to add or substitute COD with potassium dichromate ($COD_{Cr}$) and total organic carbon(TOC) being used as index of organic matter. And indexes of organic matter content and organic carbon concentration were distinguished between dissolved and particulate component in water sample to estimate their effect on pollutants loading in lake and stream. The ratio of $COD_{Cr}$/BOD was 5.1 under BOD concentration 3mg/L in river water quality environmental standard II, and 2.67 above it. This ratio was diminished to 2.04 when BOD concentration was more than 8mg/L, in river quality environmental standard IV. Also the ratio of $COD_{Mn}$/BOD showed 2.16 under 3mg/L(BOD), and 1.1 above it. This ratio is also diminished to 0.84 over 8mg/L(BOD). Accordingly, we should apply this ratio depending on the concentration level to add and change organic matter index of water quality environmental standard newly. The ratio $COD_{Cr}/COD_{Mn}$ both in lake and stream shows 2.37(r=0.986, p<0.001). But the ratios showed range of 2.34~2.50, which is no much difference of this ratio according to $COD_{Mn}$ concentration.

  • PDF

An Experimental Study on Regeneration Characteristics by Variation of Exhaust Gas Temperature, HC and $O_2$ Concentrations on DOC-CDPF System (배기가스의 온도 및 HC와 $O_2$의 조성 변화에 따른 DOC-CDPF의 재생 특성에 관한 실험적 연구)

  • Cho, Yong-Seok;Lee, Seang-Wock;Lee, Jung-Sub;Yoon, Yu-Bin;Park, Young-Joon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.1
    • /
    • pp.43-49
    • /
    • 2009
  • A catalyzed diesel particulate filter (CDPF) causes the progressive increase in back pressure of an exhaust system due to the loading of soot particles. To minimize pressure drop which is generated by CDPF, the filter should be regenerated when it collects a certain quantity of soot. It is important to know characteristics of regeneration of CDPF with various of exhaust gas temperatures and compositions. The oxidation of HC in DOC leads to increase gas temperature of DOC downstream. The increased gas temperature by DOC has an positive effect on CDPF regeneration. This study presents characteristics of regeneration of CDPF with DOC according to various gas composition, such as HC and $O_2$ concentration. The test-rig is used to control each gas composition and temperature during regeneration of CDPF. Experimental results indicate that the increased concentration of $O_2$ regenerates DPF more actively. With increasing HC concentration, the gas temperature of CDPF upstream increased due to more oxidation of HC. But excessive supply of HC leads to decrease of $O_2$ concentration in the CDPF, which makes it hard to regenerate CDPF.

Comparative Evaluation of QUAL2E and QUAL-NIER Models for Water Quality Prediction in Eutrophic River (부영양 하천의 수질예측을 위한 QUAL2E와 QUAL-NIER 모델의 비교·평가)

  • Choi, Jungkyu;Chung, Sewoong;Ryoo, Jaeil
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.1
    • /
    • pp.54-62
    • /
    • 2008
  • It is often believed that a more complex water quality model is better able to simulate reality. The more complex a model, however, the more parameters are involved thus increases the cost and uncertainty of modeling processes. The objective of this study was to compare the performance of two steady-state river water quality models, QUAL2E and QUAL-NIER, that have different complexity. QUAL-NIER is recently developed by National Institute of Environmental Research aiming to enhance the simulation capability of QUAL2E for eutrophic rivers. It is a carbon based model that considers different forms, such as dissolved versus particulate and labile versus refractory, of carbon and nutrients, and the contribution of autochthonous loading due to algal metabolism. The models were simultaneously applied to Nakdong River and their performance was evaluated by statistical verification with field data. Both models showed similar performance and satisfactorily replicated the longitudinal variations of BOD, T-N, T-P, Chl.a concentrations along the river. The algal blooms occurred at the stagnant reaches of downstream were also reasonably captured by the models. Although QUAL-NIER somewhat reduced the magnitude of errors, the hypothesis tests revealed no statistical evidence to justify its better performance. The contribution of autochthonous carbon and nutrient load by algal metabolism was insignificant because the hydraulic retention time is relatively short compare to the time scale of kinetic reactions. The results imply that the kinetic processes included in QUAL-NIER are too complex for the nature and scale of the real processes involved, thus needs to be optimized for improving the modeling efficiency.

Distribution of Inorganic Phosphorus Fractions in Sediments of the South Han River over a Rainy Season

  • Vo, Nguyen Xuan Que;Ji, Yoonhwan;Doan, Tuan Van;Kang, Hojeong
    • Environmental Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.229-240
    • /
    • 2014
  • Rain events are extremely important for phosphorus (P) dynamics in rivers since large portions of annual river P loads can be transported in particulate forms during only a few major events. Despite their importance, a precise estimation of P contribution in river sediments after rainy seasons has rarely been reported. This study estimated the longitudinal variation in the concentrations of different inorganic P fractions in bed sediments of the South Han River over a rainy season, through using the sequential extraction method. Non-apatite P was the dominant form, representing more than 60% of total inorganic P (TIP) content in sediments. Although no significant variation of TIP contents was observed, the proportion of bioavailable P in TIP pools decreased after the rainy season. The concentrations of individual inorganic P fractions ($NH_4Cl-P$, $NH_4F-P$, NaOH-P, and $H_2SO_4-P$) were significantly different across sites and after the rainy season (p < 0.05, two-way ANOVA). $NH_4F-P$ and NaOH-P concentrations in sediments increased in a downstream direction. After the rainy season, $NH_4Cl-P$ concentrations in sediments decreased whereas $NH_4F-P$ and $H_2SO_4-P$ concentrations increased. The redistribution of individual P fractions in sediments observed after rainy seasons were possibly due to the changing contribution of various sources of runoff and the variation in flow related particle size. Current estimation of P in bed sediments of the South Han River suggests a lower potential of internal P loading from sediments after the rainy season.

Development and Field-evaluation of Automatic Spreader for Bedding Materials in Duck Houses (오리사 바닥 깔짚자동살포장치 개발 및 실증)

  • Kwon, Kyeong-seok;Woo, Jae-seok;Noh, Je-hee;Oh, Sang-ik;Kim, Jong-bok;Kim, Jung-kon;Yang, Kayoung;Jang, Donghwa;Choi, Sungmin
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.1
    • /
    • pp.37-48
    • /
    • 2021
  • The automatic-spreader of bedding materials was developed to reduce labor cost, and to achieve successful biosecurity in duck houses. Algorithm of the device was designed to realize a concept of the automatic unmanned operation including entire processes such as loading and spreading of the bedding materials. From the field measurement, the relationship between the expected water content reduction and weight of bedding materials per unit area according to the operation condition of the devices was induced. In the case of the measurement of particulate matters during the process of spreading works, the results of using both conventional manual-spreader and automatic-spreader were exceeded the allowable limit of inhalable and respirable dust, respectively. But, workers using automatic-spreader could be free from harmful aero-condition because they did not stay inside the facility during the spreading works. In addition, from the Duck hepatitis virus PCR test, influence on pulmonary tissue of the duck was not found. It could be expected that the development of the automatic-spreader of bedding materials for duck house can contribute to the advancement of duck breeding facilities.

A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography (C-arm CT의 필수 성능평가 기준 마련을 위한 연구)

  • Kim, Eun-Hye;Park, Hye-Min;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

Comparison of Pollutant Removal Efficiency in Road Sediment with Media Using Filter Separator (필터 분리기를 이용한 여재별 도로퇴적물의 오염물질 제거효율 비교)

  • Bang, Ki-Woong;Lee, Jun-Ho;Choi, Chang-Su;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.332-340
    • /
    • 2007
  • Storm runoff from road contains significant loads of particulate and dissolved solids, organic constituents and metal elements. Micro particle is important when considering pollution mitigation because pollutant metal and organics have similar behavior with particles. The objective of this research is to evaluate the hydrodynamic filter separator performance for road storm runoff treatment. A various types of media such as perlite, granular activated carbon, zeolite were used for column test packing media and filter separator, and to determine the removal efficiency with various surface loading rate. As the results of column test, the highest SS removal efficiency was using mixed media(granular activated carbon, zeolite and perlite), and granular activated carbon mixed with zeolite has higher heavy metal removal efficiency than perlite. In laboratory scale hydrodynamic filter separator study, the operation ranges of surface loading rates were from 192 to 1,469 $m^3/m^2/day$. The estimated overall removal efficiencies of hydrodynamic filter separator for typical storm runoff were SS 48.1%, BOD 31.9%, COD 32.6%, TN 15.5%, and TP 17.3%, respectively. For the case of heavy metals, overall removal efficiencies were Fe 26.0%, Cu 19.4%, Cr 25.7, Zn 16.6%, and Pb 15.0%, respectively. The most appropriate medium for hydrodynamic filter separator was perlite mixed with granular activated carbon to treatment of road storm runoff.

High Loading for Air Pollution in the Byunsan Peninsula of Korea by an Interplay of the Saemangeum Project and Winter Monsoon

  • Ma, Chang-Jin;Kang, Gong-Unn;Kim, Ki-Hyun
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.3
    • /
    • pp.234-243
    • /
    • 2012
  • The wintertime high loading for atmospheric pollutants is certainly expected in the Byunsan Peninsula of Korea because of a great-scale reclamation project having construction of 33 km tidal sea dike impounding an area of over 40,000 ha and long-range transport. The goal of this study is to trace the origin of this wintertime burden for ambient particulate matter (hereafter called "PM") in the Byunsan Peninsula of Korea. The size-segregated (i.e., cutoff size from 0.01 ${\mu}m$ to 4.7 ${\mu}m$) PM sampling was conducted at a ground-based site of Byunsan Peninsula located in the west coast of Korean Peninsula during the height of dike constructing. Data archived in this study are the mass concentrations of ionic, elemental, and carbonic components in size-fractioned PM. The elemental mass of individual submicrometer particles was also analyzed. The sum of 5-source (i.e., elemental carbon, organic materials, inorganic secondary pollutants, crustal matter, and sea-salts) concentrations shows the bimodal distribution (major and minor peaks formed around $D_p$, 0.65 ${\mu}m$ and $D_p$, 4.7 ${\mu}m$, respectively) by border with 0.19 ${\mu}m$ of cutoff size. The concentrations of EC in $PM_{1.1-0.01}$ in winter and spring times were 4.62 ${\mu}g\;m^{-3}$ and 3.74 ${\mu}g\;m^{-3}$, respectively. Elemental masses of submicron individual particles are classified into two groups, i.e., the major elements (Cl, Al, Si, S, and P) and the minor trace elements. Cluster analysis differentiated the elements in submicron individual particles into 4-cluster. Among them, three clusters are in agreement with the major (Al, Si, S, and P), minor (Fe, Ca, and K), and trace compositions of coal burning. Meanwhile, Cl classified as an independent cluster has different source profile which was mainly due to the Saemangeum seawall project. Some highly toxic elements (e.g., Cr, Mn, and As (and/or Pb)) were also detected in some part of submicron individual PM. As a consequence, the combination of the Saemangeum project and winter monsoon played a considerable part in the double aggravation of wintertime air pollution in the Byunsan Peninsular.

Ag-Loaded LaSrCoFeO3 Perovskite Nano-Fibrous Web for Effective Soot Oxidation (Ag 담지된 LaSrCoFeO3 섬유상 perovskite 촉매의 탄소 입자상 물질의 산화반응)

  • Lee, Chanmin;Jeon, Yukwon;Hwang, Ho Jung;Ji, Yunseong;Kwon, Ohchan;Jeon, Ok Sung;Shul, Yong-Gun
    • Korean Chemical Engineering Research
    • /
    • v.57 no.4
    • /
    • pp.584-588
    • /
    • 2019
  • The catalytic combustion of particulate matter (PM) is one of the key technologies to meet emission standards of diesel engine system. Therefore, we herein suggest Ag loaded $La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_3$ perovskite web catalyst. They were produced by the electrospinning method. FE-SEM, EDS mapping, XRD, XPS were studied to investigate the crystal and morphological structures of loaded Ag particles and $La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_3$ perovskite web catalyst. Following the catalytic soot oxidation, we found that the Ag loaded $La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_3$ perovskiteweb catalyst showed the higher catalytic activities (e.g., $T_{50}=490^{\circ}C$) than the only $La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_3$ perovskite web catalyst (e.g., $T_{50}=586^{\circ}C$). Thus, this finding suggests that Ag loaded $La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_3$ perovskite web catalyst can be a promising candidate for enhancing the soot oxidation.

Determination of Heavy Metal Unit Load from Transportation Landuses during a Storm (교통 관련 토지이용에서의 중금속 오염원단위 산정)

  • Kim, Cheol-Min;Lee, So-Young;Lee, Eun-Ju;Kim, Lee-Hyung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.155-160
    • /
    • 2008
  • The urban areas have various landuses such as residential, commercial, industrial and official purposes that are highly concerned with human activities. The other landuses are relating to vehicle activities, which are roads, parking lots, bridges, parks etc. The mainly using landuses by human activities are possessing three different areas that are buildings, parking lots/roads and landscapes. Of these areas, the buildings and landscapes can be classified as non-pollution areas. However, the parking lots or roads are classifying as the main pollution areas because of vehicle activities. Therefore, the landuses arising the nonpoint pollution during a storm in urban areas are roads and parking lots. The vehicles are emitting lots of nonpoint pollutants such as metals and particulate matters and it is impacting on water qualities and aqua-ecosystems nearby the city areas. Therefore, this research was conducted for characterizing the pollutant types and determining the EMCs (Event Mean Concentrations) and unit pollutant loads during a storm. The monitoring was performed on 9 locations such as highways, service area, tollgates, parking lot and bridges. All of the landuses selected for monitoring are concerned with transportation. The results can be effectively used to predict the pollutant loading before urban planning and to select the BMPs (Best Management Practices) for reducing the pollution.