• Title/Summary/Keyword: Particulate air pollution

Search Result 436, Processing Time 0.036 seconds

Composition and pollution characteristics of TSP, PM2.5 atmospheric aerosols at Gosan site, Jeju Island (제주도 고산지역 TSP, PM2.5 대기에어로졸의 조성 및 오염 특성)

  • Lee, Soon-Bong;Kang, Chang-Hee;Jung, Duk-Sang;Ko, Hee-Jung;Kim, Haeng-Bum;Oh, Yong-Soo;Kang, Hae-Lim
    • Analytical Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.371-382
    • /
    • 2010
  • TSP and PM2.5 atmospheric aerosols have been collected at Gosan site of Jeju Island, and their compositions were analyzed to understand the pollution characteristics. The composition ratios of nss (non-sea salt)-$SO_4^{2-}$ and $NH_4^+$ were higher in Gosan site than those in other Korean background and urban sites. However the composition ratio of $NO_3^-$ was conversely lower in Gosan site. From the study of aerosol components according to particle sizes, the anthropogenic nss-$SO_4^{2-}$, $NO_3^-$ and $NH_4^+$ components were mostly existed in the fine particles. But the nss-$Ca^{2+}$, $Na^+$, $Cl^-$ and $Mg^{2+}$ originated from soil and marine sources were distributed relatively in the coarse particles. In the seasonal comparison, the concentrations of nss-$Ca^{2+}$, Al, Fe, Ca and $NO_3^-$ increased in spring season, and nss-$SO_4^{2-}$ showed higher concentration in summer and spring seasons. Based on the factor analysis, the atmospheric aerosols in Gosan site have been found to be influenced largely by anthropogenic sources, and next by marine and soil sources. The backward trajectory analyses showed that the concentrations of nss-$SO_4^{2-}$, $NO_3^-$, Pb and nss-$Ca^{2+}$ increased when the air mass moved from Chinese continent to Jeju area. On the other hand, their concentrations decreased when the air mass moved in from the North Pacific Ocean.

A Comparative Study on PM10 Source Contributions in a Seoul Metropolitan Subway Station Before/After Installing Platform Screen Doors (서울시 지하철 승강장의 스크린도어 설치 전·후 PM10 오염원의 기여도 비교 연구)

  • Lee, Tae-Jung;Jeon, Jae-Sik;Kim, Shin-Do;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.543-553
    • /
    • 2010
  • Almost five million citizens a day are using subways as a means of traffic communication in the Seoul metropolitan. As the subway system is typically a closed environment, indoor air pollution problems frequently occurs and passengers complain of mal-health impact. Especially $PM_{10}$ is well known as one of the major pollutants in subway indoor environments. The purpose of this study was to compare the indoor air quality in terms of $PM_{10}$ and to quantitatively compare its source contributions in a Seoul subway platform before and after installing platform screen doors (PSD). $PM_{10}$ samples were collected on the J station platform of Subway Line 7 in Seoul metropolitan area from Jun. 12, 2008 to Jan. 12, 2009. The samples collected on membrane filters using $PM_{10}$ mini-volume portable samplers were then analyzed for trace metals and soluble ions. A total of 18 chemical species (Ba, Mn, Cr, Cd, Si, Fe, Ni, Al, Cu, Pb, Ti, $Na^+$, $NH_4^+$, $K^+$, $Mg^{2+}$, $Ca^{2+}$, $Cl^-$, and ${SO_4}^{2-}$) were analyzed by using an ICP-AES and an IC after performing proper pre-treatments of each sample filter. Based on the chemical information, positive matrix factorization (PMF) model was applied to identify the source of particulate matters. $PM_{10}$ for the station was characterized by three sources such as ferrous related source, soil and road dust related source, and fine secondary aerosol source. After installing PSD, the average $PM_{10}$ concentration was decreased by 20.5% during the study periods. Especially the contribution of the ferrous related source emitted during train service in a tunnel route was decreased from 59.1% to 43.8% since both platform and tunnel areas were completely blocked by screen doors. However, the contribution of the fine secondary aerosol source emitted from various outside combustion activities was increased from 14.8% to 29.9% presumably due to ill-managed ventilation system and confined platform space.

Exposure and Toxicity Assessment of Ultrafine Particles from Nearby Traffic in Urban Air in Seoul, Korea

  • Yang, Ji-Yeon;Kim, Jin-Yong;Jang, Ji-Young;Lee, Gun-Woo;Kim, Soo-Hwan;Shin, Dong-Chun;Lim, Young-Wook
    • Environmental Analysis Health and Toxicology
    • /
    • v.28
    • /
    • pp.7.1-7.9
    • /
    • 2013
  • Objectives We investigated the particle mass size distribution and chemical properties of air pollution particulate matter (PM) in the urban area and its capacity to induce cytotoxicity in human bronchial epithelial (BEAS-2B) cells. Methods To characterize the mass size distributions and chemical concentrations associated with urban PM, PM samples were collected by a 10-stage Micro-Orifice Uniform Deposit Impactor close to nearby traffic in an urban area from December 2007 to December 2009. PM samples for in vitro cytotoxicity testing were collected by a mini-volume air sampler with $PM_{10}$ and $PM_{2.5}$ inlets. Results The PM size distributions were bi-modal, peaking at 0.18 to 0.32 and 1.8 to $3.2{\mu}m$. The mass concentrations of the metals in fine particles (0.1 to $1.8{\mu}m$) accounted for 45.6 to 80.4% of the mass concentrations of metals in $PM_{10}$. The mass proportions of fine particles of the pollutants related to traffic emission, lead (80.4%), cadmium (69.0%), and chromium (63.8%) were higher than those of other metals. Iron was the dominant transition metal in the particles, accounting for 64.3% of the $PM_{10}$ mass in all the samples. We observed PM concentration-dependent cytotoxic effects on BEAS-2B cells. Conclusions We found that exposure to $PM_{2.5}$ and $PM_{10}$ from a nearby traffic area induced significant increases in protein expression of inflammatory cytokines (IL-6 and IL-8). The cell death rate and release of cytokines in response to the $PM_{2.5}$ treatment were higher than those with $PM_{10}$. The combined results support the hypothesis that ultrafine particles from vehicular sources can induce inflammatory responses related to environmental respiratory injury.

Health and Environmental Risk Assessment of Pollutants in Pohang (포항지역 오염물질 보건.환경 위해성 평가 -미세먼지의 발생특성 및 농도분포를 중심으로-)

  • Jung, Jong-Hyeon;Choi, Won-Joon;Leem, Heon-Ho;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2719-2726
    • /
    • 2010
  • The purpose of this study was to investigate the scientific basic grounds for the assessment of health and environmental diseases resulting from air pollutants in Pohang. For this study, we investigated pollutants, weather characteristics and concentration distribution of fine particles ($PM_10$) yearly and each season, using data from Air Quality Monitoring Stations. The properties of concentration distribution and seasonal fluctuation of $PM_10$ were studied qualitatively and quantitatively using CALPUFF, air dispersion model. The average concentration of $PM_10$ for each season was spring($75.7{\mu}g/m^3$)>summer($56.8{\mu}g/m^3$)>winter($53.6{\mu}g/m^3$)>fall( $52.7{\mu}g/m^3$). In the case of spring, high concentrations appear due to the Asian dust frequently occurring. The contributions of $PM_10$ classified by the types of pollution source in Pohang were point source 62%>mobile source 33%>area source 5%. An important point is that 97% of emissions were produced from the iron manufacture in steel industry. Therefore, it is necessary to control the emission sources of pollutants and to construct an observation system at Pohang steel industrial complex from now on. It’s time to control the risk factors for health and environmental disease to protect the health of resident in Pohang and its neighboring areas.

Cytotoxicity of Particulate Matter in Various Human Cells Lines (미세먼지가 다양한 사람 세포주에 미치는 세포 독성)

  • Lee, Ji-Hyeon;Lee, Joo-Yeong;Kim, Mi-Jeong;Kim, Hyeon-Ji;Lee, Sung-Ho;Jeon, Byeong-Gyun
    • Journal of Life Science
    • /
    • v.29 no.6
    • /
    • pp.724-734
    • /
    • 2019
  • The present study investigated the cytotoxicity of particulate matter (PM) derived from car air filter (outdoor PM) and home cleaner filter (indoor PM) in the various human cell lines. Each outdoor and indoor PM were harvested by ethanol extraction method, subsequently sieved with 10 um filter paper, sterilized with autoclave and added to culture media. The half maximal inhibitory concentration ($IC_{50}$) values was significantly (p<0.05) lower in the outdoor PM, compared with indoor PM, and the significantly (p<0.05) higher $IC_{50}$ values were observed in the cancer cell lines (A-549 lung adenocarcinoma and AGS stomach adenocarcinoma), than those of normal MRC-5 fibroblasts and dental papilla tissue derived-mesenchymal stem cells (DSC). After being exposed to $100{\mu}g/ml$ outdoor PM for 7 days, the population doubling time (PDT) was significantly (p<0.05) increased in especially MRC-5 and DSC cell lines, compared with untreated cell lines. Further, the expression of senescence-associated ${\beta}$-galactosidase activity was up-regulated in all the cells exposed to outdoor PM than those of untreated control. Besides, the expression level of inflammation-associated genes, such as cyclooxygenase-2 (COX-2) and interleukin-6 (IL-6) was found to be significantly (p<0.05) increased in the outdoor PM-treated cell lines than those of untreated cell lines. Our results showed that PM induces the cytotoxicity via arrest of cell growth, cell damage and inflammation response.

Comparison Study of the Pulmonary Function and Serum Carboxyhemoglobin Level Between the Traffic Policmen and Clerk Policemen (교통경찰과 비 교통경찰의 폐기능과 혈중 Carboxyhemoglobin 수치에 대한 비교연구)

  • Kim, Sung Min;Cheon, Gyu Rak;Kim, Young Wook;Kim, Joon Hyung;Lee, Ho Hak;Hong, Soon Chang;Lee, Seung Hee;Park, Sang Joon;Chung, Joon Oh;Kim, Yun Kwon;Kim, So Yon;Kim, Young Jung;Cho, Min Koo;Lee, Gwon Jun;Lee, Kyung In
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.6
    • /
    • pp.560-569
    • /
    • 2003
  • Background : A large number of pollutants such as sulfur dioxide, nitric oxide, carbon monoxide, particulate matter, and ozone influence on the body. These pollutants put a burden on the lung and the sequelae resulting from the oxidative stress are thought to contribute to the development of fibrotic lung disease, emphysema, chronic bronchitis and lung cancer. Also, carbon monoxide generated from the incomplete combustion of carbon-containing compounds is an important component of air pollution caused by traffic exhaust fumes and has the toxic effect of tissue hypoxia and produce various systemic and neurologic complications. The objective of this study is to compare the difference of pulmonary function and serum carboxyhemoglobin(CO-Hb) level between the traffic policemen and clerk policemen. Method : Three hundred and twenty-nine of traffic policemen, and one hundred and thirty clerk policemen were included between 2001 May and 2002 August. The policemen who took part in this study were asked to fill out a questionnaire which included questions on age, smoking, drinking, years of working, work-related symptoms and past medical history. The serum CO-Hb level was measured by using carboxyoximeter. Pulmonary function test was done by using automated spirometer. Additional tests, such as elecrocardiogram, urinalysis, chest radiography, blood chemistry, and CBC, were also done. Results : $FEV_1(%)$ was $97.1{\pm}0.85%$, and $105.7{\pm}1.21%$(p<0.05). FVC(%) was $94.6{\pm}0.67%$, and $102.1{\pm}1.09%$, respectively(p<0.05). Serum CO-Hb level was $2.4{\pm}0.06%$, and $1.8{\pm}0.08%$(p<0.05). After correction of confounding factors (age, smoking), significant variables were FVC(%), $FEV_1(%)$ and serum CO-Hb level(%)(p<0.05). Conclusion : Long exposure to air pollution may influence the pulmonary function and serum CO-Hb level. But, further prospective cohort study will be needed to elucidate detailed influences of specific pollutants on pulmonary function and serum carboxyhemoglobin level.

A Study on the Measurement of the Dimensionless Light Extinction Constant for Particulate Matter from Fuel Oil for Marine and Land Diesel Engines (선박 및 육상 디젤 엔진용 연료유에서 발생하는 입자상물질에 대한 무차원 광소멸계수 계측에 관한 연구)

  • Rho, Beom-Seok;Choi, Jae-Hyuk;Cho, Kwon-Hae;Park, Seul-Hyun;Lee, Won-Ju
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.2
    • /
    • pp.275-281
    • /
    • 2018
  • It is known that he pollutant emitted from the combustion process of marine fuel oil causes air pollution and harmful effects to the human body. Accordingly, IMO regulates pollutants emitted from ships. However, the regulation of Particulate Matter (PM) is still in the process of debate, so preemptive action is needed. Fundamental research on PM is essential. In this study, the Dimensionless Light Extinction Constant ($K_e$) of fuel oil used in marine diesel engines was measured and analyzed to construct the basic data of the PM generated from marine-based fuel oil. The fuel oil used in the land diesel engine was measured in the same way for character comparison. Both fuel oils differ in sulfur content and density. The $K_e$ was measured via the optical method using a 633 nm laser and was determined by using the volume fraction of PM collected by the gravimetric filter method. The $K_e$ of the PM discharged from marine fuel oil is 8.28, and the land fuel oil is 8.44. The $K_e$ of two fuel oils was similar within the measurement uncertainty range. However, it was found by comparison with the value obtained by the Rayleigh-Limit solution that the light scattering portion could be large. Also, it was found that light extinction characteristics could be different due to the relationship between light transmittance and collected mass.

A study on the characteristics of fuel performance according to the oxygenated additive type for gasoline fuel Part 1. Fuel properties and evaporative emission characteristics (휘발유 연료용 함산소 첨가제 종류에 따른 성능 특성 연구 Part 1. 연료물성 및 증발가스 배출 특성)

  • Lee, Min-Ho;Kim, Jong-Ryeol;Kim, Ki-Ho;Ha, Jong-Han
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.118-128
    • /
    • 2016
  • As the interest on the air-pollution is gradually rising up at home and abroad, automotive and fuel researchers have been working on the exhaust emission reduction from vehicles through a lot of approaches, which consist of new engine design, innovative after-treatment systems, using clean (eco-friendly alternative) fuels and fuel quality improvement. This research has brought forward two main issues : exhaust emission and PM (particulate matter) particle emissions of gasoline vehicle. Exhaust emission and PM particle of automotive had many problem that cause of ambient pollution, health effects. In addition, researcher studied the environment problems of the MTBE contained in the fuel as oxygenate additives. The researchers have many data about the health effects of ingestion of MTBE. However, the data support the conclusion that MTBE is a potential human carcinogen at high doses. Based on the oxygenated fuel additive types (MTBE, Bio-ETBE, Bio-ethanol, Bio-butanol), this paper discussed the influence of oxygen contents on gasoline fuel properties and evaporative emission characteristics. Also, this paper assessed the acceleration and power performance of gasoline vehicle for the fuel property.

Indoor Exposure and Health Risk of Polycyclic Aromatic Hydrocarbons (PAHs) in Public Facilities, Korea

  • Kim, Ho-Hyun;Lim, Young-Wook;Jeon, Jun-Min;Kim, Tae-Hun;Lee, Geon-Woo;Lee, Woo-Seok;Lim, Jung-Yun;Shin, Dong-Chun;Yang, Ji-Yeon
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.2
    • /
    • pp.72-84
    • /
    • 2013
  • In the study, pollution levels of indoor polycyclic aromatic hydrocarbons (PAHs) in public facilities (vapor phase or particulate phase) were evaluated, and a health risk assessment (HRA) was carried out based on exposure scenarios. Public facilities in Korea covered by the law, including underground subway stations, funeral halls, child care facilities, internet cafes (PC-rooms), and exhibition facilities (6 locations for each type of facility, for a total of 48 locations), were investigated for indoor assessment. For the HRA, individual excess cancer risk (ECR) was estimated by applying main toxic equivalency factor (TEF) values suggested in previous studies. Among the eight public facilities, internet cafes showed the highest average $PM_{2.5}$ concentration at $110.0{\mu}g/m^3$ (range: $83.5-138.5{\mu}g/m^3$). When assuming a risk of facility exposure time based upon the results of the surveys for each public facility, the excess cancer risk using the benzo(a)pyrene indicator assessment method was estimated to be $10^{-7}-10^{-6}$ levels for each facility. Based on the risk associated with various TEF values, the excess cancer risk based upon the seven types cancer EPA (1993) and Malcolm & Dobson's (1994) assessment method was estimated to be $10^{-7}-10^{-5}$ for each facility. The excess cancer risk estimated from the TEF EPA (2010) assessment was the highest: $10^{-7}-10^{-4}$ for each facility. This is due to the 10-fold difference between the TEF of dibenzo(a,e)fluoranthene in 2010 and in 1994. The internet cafes where smoking was the clear pollutant showed the highest risk level of $10^{-4}$, which exceeded the World Health Organization's recommended risk of $1{\times}10^{-6}$. All facilities, with the exception of internet cafes, showed a $10^{-6}$ risk level. However, when the TEFs values of the US EPA (2010) were applied, the risk of most facilities in this study exceeded $1{\times}10^{-6}$.

Chemical Characteristics and Particle Size Distribution of PM10 in Iron and Steel Industrial Complex (포항철강공단 미세먼지(PM10)의 입경분포 및 화학적 특성)

  • Jung, Jong-Hyeon;Lee, Hyung-Don;Jeon, Soo-Bin;Yoo, Jeong-Kun;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5601-5609
    • /
    • 2012
  • The fine particulate matter($PM_{10}$) concentrations and contents were measured to check the health and environment influential factors in Pohang Iron and Steel Industrial Complex and its vicinities. In addition, the $PM_{10}$ distribution for each year and season was surveyed using the regional air quality monitoring stations. The measuring on the $PM_{10}$ inside the industrial complex showed $61.3{\pm}12.1{\mu}g/m^3$ for average concentration of $PM_{10}$ which was measured by Dongil Industry and $44.3{\pm}8.1{\mu}g/m^3$ measured by steel manufacturing industry complex management office. Both of them satisfied the environmental air quality standard. The percentage of $SO_4{^2}$, $NO_3{^-}$, $NH_4{^+}$ which are the secondary ions created out of the $PM_{10}$ in Dongil Industry and steel manufacturing industry complex management office was checked and it was revealed that the percentage of ${SO_4}^{2-}$ was high and it is considered that the pollution source related with the sulfides exist at the industrial complex. They were in order of ${SO_4}^{2-}$ > $Cl^-$ > $NO_3{^-}$ > $F^-$ > $NH_4{^+}$ in Dongil Industry and ${SO_4}^{2-}$ > $Cl^-$ > $NO_3{^-}$ > $NH_4{^+}$ > $F^-$ in steel manufacturing industry complex management office.