• 제목/요약/키워드: Particle deposition

검색결과 569건 처리시간 0.027초

전기장이 형성된 관성 충돌기에서 대전 입자의 거동과 부착 특성에 대한 연구 (Pre-Charged Particle Deposition in an Impactor subjected to an Electric Field)

  • 박형호;김상수
    • 대한기계학회논문집B
    • /
    • 제23권3호
    • /
    • pp.299-310
    • /
    • 1999
  • Effect of electrostatic and inertial forces on the pre-charged particle deposition was theoretically and experimentally studied by introducing the inertia impactor subjected to an electric field. To derive the analytic solution, we assumed that a flow was an ideal stagnation flow, a particle had saturation charges, and the electric field within the test section was uniform. On the other hand, $Al_2O_3$ particle groups were used as the test particles, which mean sizes were $1{\mu}m$, $3{\mu}m$, and $5{\mu}m$. To measure the deposition efficiency, the light scattering method was used. The results showed that the deposition efficiency was minimized at a certain nozzle velocity as increasing the nozzle velocity, only if the electric force was applied. As the electric field strength increased, $Stk_{50}{^{1/2}}$ was decreased, and its decreasing rate was reduced with increasing the flow velocity. Moreover the existence of electric field was against the cut-off performance of the inertia impactor.

High resolution size characterization of particulate contaminants for radioactive metal waste treatment

  • Lee, Min-Ho;Yang, Wonseok;Chae, Nakkyu;Choi, Sungyeol
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2277-2288
    • /
    • 2021
  • To regulate the safety protocols in nuclear facilities, radioactive aerosols have been extensively researched to understand their health impacts. However, most measured particle-size distributions remain at low resolutions, with the particle sizes ranging from nanometer to micrometer. This study combines the high-resolution detection of 500 size classes, ranging from 6 nm to 10 ㎛, for aerodynamic diameter distributions, with a regional lung deposition calculation. We applied the new approach to characterize particle-size distributions of aerosols generated during the plasma arc cutting of simulated non-radioactive steel alloy wastes. The high-resolution measured data were used to calculate the deposition ratios of the aerosols in different lung regions. The deposition ratios in the alveolar sacs contained the dominant particle sizes ranging from 0.01 to 0.1 ㎛. We determined the distribution of various metals using different vapor pressures of the alloying components and analyzed the uncertainties of lung deposition calculations using the low-resolution aerodynamic diameter data simultaneously. In high-resolution data, the changes in aerosols that can penetrate the blood system were better captured, correcting their potential risks by a maximum of 42%. The combined calculations can aid the enhancement of high-resolution measuring equipment to effectively manage radiation safety in nuclear facilities.

Influence of constraint MgO deposition onto phosphors on luminance properties in AC Plasma Display Panels

  • Jeoung, Jin-Man;OH, P.Y.;Moon, M.W.;Lee, J.H.;Jeong, J.E.;Lee, H.J.;Han, Y.K.;Lee, S.B.;Jeong, S.H.;Yoo, C.K.;Yoo, N.R.;Choi, E.H.;Ko, B.D.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1215-1217
    • /
    • 2005
  • One of the important problems in recent AC-PDP technology is the image sticking. In this research, we have investigated the PDP cell with constraint deposition MgO on phosphor, the electrical and optical properties in the PDP cell were examined. Also, we have investigated the correlation with image sticking and degraded MgO protective layer, phosphor in AC-PDP. As a result, we measured the secondary electron emission coefficient ${\gamma}$, discharge characteristics and Brightness for the constraint degraded phosphor are compared with those of nondegraded phosphor.

  • PDF

외부 전기장내의 단일 섬유에 대한 먼지층 형사 수치 모사 (Numerical Simulation of Particle Deposition Pattern on Cylindrical Fiber under External Electrical Field)

  • 박현설;정용원;박영옥;이규원
    • 한국대기환경학회지
    • /
    • 제15권1호
    • /
    • pp.41-51
    • /
    • 1999
  • In this study, the two dimensional morphology of particle accumulates on a cylindrical fiber was numerically simulated when a uniform external electric field was present across a cylindrical fiber. In order to investigate the mechanism of linear dendrite formation which is observed under the above electrostatic condition, the electrostatic forces between a newly introduced particle and each deposited particle were calculated and compared with those between the particle and fiber As a result of this study it was found that dielectrophoretic forces between the oncoming particle and fiber play principal roles in linear dendrite formation.

  • PDF

입자상 PCBs 건식침적량과 입경분포 특성: 1999년 가을 측정 (Characteristics of the dry deposition fluxes and ambient particl size distributions of PCBs: The measurements on fall, 1999)

  • 신혜정;김용표;이승묵
    • 한국입자에어로졸학회지
    • /
    • 제5권4호
    • /
    • pp.179-188
    • /
    • 2009
  • The dry deposition fluxes of particulate polychlorinated biphenyls (PCBs) were measured along with their mass size distributions at Seoul and Incheon in fall in 1999. The dry deposition fluxes of PCBs were in the range of $16.7{\sim}62.2ng/m^2/day$. The ambient concentrations of particulate PCBs were in the range of 0.07 to $0.20ng/m^3$. Generally, the mass size distribution of particulate PCBs shows bi-modal distribution. The mass fraction of PCBs in the fine particle fraction ($D_p<2.1 {\mu}m$) was over than 55% of the total PCBs concentrations. It was found that Seoul and Incheon were not the major source of PCBs emissions in Korea. Based on the comparison with the measurement data in summer, 1999, it is likely that both the dry deposition fluxes and ambient particulate PCBs concentrations were not site-specific.

  • PDF

대기중 중금속 입자의 입경분포 및 건식침적 특성에 관한 연구 (A Study on the Characterization of Size Distributions and Atmospheric Dry Deposition of Heavy Metals)

  • 이승묵;이은영;정장표
    • 대한환경공학회지
    • /
    • 제22권3호
    • /
    • pp.575-585
    • /
    • 2000
  • 서울지역의 질량 및 중금속 건식침적량과 대기중 입자의 입경분포를 1998년 7월부터 11월까지 건식침적판, 다단계 관성충돌 채취기(Cascade Impactor) 및 조대업자 채취기(Coarse Particle Sampler)를 사용하여 측정하였다. 인위적 오염원에 기인한 중금속(Cu, Mn, Ni, Pt, Zn)의 건식침적량이 주로 자연적 오염원에 기인한 중금속(Al, Ca)의 건식침적량에 비하여 약 10배에서 100배 정도 낮은 값을 나타내었다. 완전한 총 입자 및 중금속 입자의 입경분포는 입자 입경이 $10{\mu}m$보다 작은 영역에서 두 개의 peak를 보이고 $10{\mu}m$보다 큰 입자 영역에서 또다른 peak을 보이는 삼봉형(trimodal) 입경분포를 보여주었다. Sehmel-Hodgson 모델을 사용하여 건식침적속도를 추정하고 이를 이용하여 총 입자 및 중금속 입자의 건식침적량을 계산하기 위하여 다단계 모델(Multi-step model)을 사용하였다. 이 방법에 의하면, 건식침적량은 입자의 입경이 $10{\mu}m$보다 큰 입자들의 높은 건식침적속도에 의하여 크게 영향을 받고 이로부터 건식침적은 $10{\mu}m$보다 큰 입자들의 침적이 대부분을 차지한다는 것을 보여주었다. 측정된 입자의 입경분포와 추정된 건식침적속도를 이용하여 다단계 모델을 통하여 예측된 건식침적량은 직접 측정된 건식침적량과 비교하였을 때 잘 일치하였다.

  • PDF

내부제트 분사를 이용한 새로운 광섬유제조 화학증착 방법에 관한 연구 (An Aerosol CVD Method Using Internal Jet for Optical Fiber Synthesis)

  • 홍춘근;최만수
    • 대한기계학회논문집B
    • /
    • 제24권4호
    • /
    • pp.608-613
    • /
    • 2000
  • The present study has proposed a novel aerosol CVD utilizing an internal jet in the conventional MCVD reactor for the purpose of enhancing the deposition efficiency(and rate) and the uniformity of deposited film. The use of impingement of high temperature jet through a thin inner tube ensures the reduction of non-uniform particle deposition zone as well as higher thermophoretic particle deposition. It is shown that significant improvements have been achieved for both aspects of deposition efficiency and uniformity. As jet temperatures increase, the tapered length is reduced and deposition efficiency is significantly increased.

보조전계를 이용한 전기영동 초전도 막의 제작 (Superconducting film fabrication using field Assisted Electrophoresis)

  • 소대화;전용우
    • 한국전기전자재료학회논문지
    • /
    • 제16권2호
    • /
    • pp.157-162
    • /
    • 2003
  • For fabricating high T$\sub$c/ superconducting deposition film, novel electrophoretic deposition (EPD) technique applied to deposit surface charged particles on metal substrate with only d.c field has been studied. However, the electric properties of superconducting film could not be improved easily by this way, because the particles of EPD film were usually deposited randomly on metal substrate without any directional orientation affected to its critical current density. For the purpose of obtaining partcle orientation on the EPD films, the new method modified by a.c. assisted field to the conventional electrophoresis system was investigated to improve the particle deposition density and to increase the contacting area among the particles with highly oriented particle deposition of BSCCO superconducting film.

Optimization of the Material and Structure of Component Parts for Reducing the Number of Impurity Particles in CVD Process

  • Kim, Won Kyung;Woo, Ram;Roh, Jong Wook
    • 한국세라믹학회지
    • /
    • 제56권3호
    • /
    • pp.277-283
    • /
    • 2019
  • We have examined minimization of the number of impurity particles by replacing the load-lock chamber materials of the chemical vapor deposition equipment through optimization of the pumping method in the deposition chamber. In order to reduce the number of impurity particles in the chamber, the load-lock spacer material was changed from monomer casting nylon to Torlon. Furthermore, we controlled the pumping speed and number of pumping ports, which resulted in a reduction in the impurity particle generation from 2.67% to 0.52%. This study revealed that the selection of the material for the parts of a chemical vapor deposition chamber can minimize particle generation, thereby presenting a method of optimization method of the chemical vapor deposition chamber.

열영동력이 수평 웨이퍼상의 입자침착에 미치는 영향 (Thermophoretic Effect on Particle Deposition Toward a Horizontal Wafer)

  • 배귀남;박승오;이춘식
    • 대한기계학회논문집
    • /
    • 제18권1호
    • /
    • pp.175-183
    • /
    • 1994
  • To investigate thermophoretic effect on particle deposition, average deposition velocity toward a horizontal wafer surface in vertical airflow is measured keeping the wafer surface temperature different from the surrounding air temperature. In the present measurement, the temperature difference is maintained in the range from -10 to $4^{\circ}$ C Polystyrene latex (PSL) spheres of diameter between 0.3 and 0.8 .mu.m are used for the experiment. The number of particles deposited on a wafer surface is estimated from the measurements using a wafer surface scanner (PMS SAS-3600). Experimental data are compared with prediction model results.