• Title/Summary/Keyword: Particle beam

Search Result 386, Processing Time 0.028 seconds

Nanoparticle Focusing with A Novel Converging-Diverging-Type Aerodynamic Lens (수축-발산형 공기역학렌즈를 이용한 초미세 나노 입자의 집속)

  • Lee, Kwang-Seung;Kim, Song-Kil;Lee, Dong-Geun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.8
    • /
    • pp.589-596
    • /
    • 2008
  • An orifice type of aerodynamic lens is generally used to focus nanoparticles. However, it is impossible to focus particles smaller than 10nm in air due to flow instability of fluid in a lens. In this study, we propose a new converging-diverging type of the aerodynamic lens capable of focusing particles of 5-50nm in air. Designing factors of the lens configurations is also extracted and explained in detail through a numerical simulation. It was demonstrated that the aerosols are delivered from the entrance to the downstream of the lens system with 90% transmission efficiency. The final beam diameters are shown to be more or less 1mm in the range of particle size.

Changes in the Modulation Amplitude and the Particle Sizes of Co/Pd Multilayers During Stress Release and Interdiffusion

  • Kim, Jai-Young;Evetts, Jan-E
    • Journal of Magnetics
    • /
    • v.3 no.1
    • /
    • pp.21-30
    • /
    • 1998
  • An artificially modulated magnetic Co/Pd multilayer is one of the promising candidates for high density magneto-optic (MO) recording media, due to large Kerr rotation angle in the wavelength of a blue laser beam. however, since multilayer structure, as well as amorphous structure, is a non-equilibrium state in terms of free energy and MO recording is a kind of thermal recording which is conducted aound Curie temperature (Tc) of the recording media, when the multilayer is used for the MO recording media, changes in the multilayer structure are occurred as the amorphous structure do. Therefore, the assessment of the structural stability in the Co/Pd multilayer is crucially important both for basic research and applications. As the parameter of the structural stability in this research, modulation amplitude and particle size of the Co/Pd multilayer are measured in terms of Ar sputtering pressure and heat treatment temperature. From the results of the research, we find out that the magnetic exchange energy in the structural changes of a magnetic multilayer structure and suggest the operating temperature range for MO recording in the Co/Pd multilayer for the basic research and applications, respectively.

  • PDF

Particle Acceleration via Laser Ablation

  • Choi, Ji-Hee;Yoh, Jai-Ick
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.566-569
    • /
    • 2008
  • Recently, the biolistic process is emerging as an effective needle-free drug delivery technique to transfer adequate concentrations of pharmacologic agents to soft living tissues with minimum side effects. We have started developing an effective method for delivering drug coated particles using laser ablation. A thin metal foil with deposited micro-particles on one side is irradiated with laser beam on the opposite side so that a shock wave is generated. This shock wave travels through the foil and is reflected, which causes and instantaneous deformation of the foil. Due to such a sudden deformation, the micro-particles are ejected at a very high speed. Here we present the experimental results of direct and confined laser ablation, which correspond to the initial stage of the whole experiment.

  • PDF

Characteristic of In Situ Suspended Particulate Matter at the Gwangyang bay Using LISST-100 and ADCP (LISST-100과 ADCP를 이용한 광양만 현장 부유입자물질 특성 연구)

  • Lee, Byoung-Kwan;Kim, Seok-Yun
    • Journal of Environmental Science International
    • /
    • v.18 no.11
    • /
    • pp.1299-1307
    • /
    • 2009
  • In order to measure in-situ suspended particle size, volume concentration of suspended particulate matter and current speed, mooring observation was performed at the Gwangyang Bay by using of an optical instrument, 'LISST-100' and an acoustic instrument, 'ADV'(St. S1). And the sediment flux was obtained based on the concentration of suspended particulate matter and current speeds measured at three lines of Gwangyang Bay during ebb and flood tide of August 2006. To investigate the spatial variation of suspended particulate matter, profiling observations were measured difference echo intensity and beam attenuation coefficient by using of ADCP and Transmissometer (Line A, B, C). The suspended sediment flux rate at the mouth of Gwangyang Bay was observed to be higher during asymmetrical than symmetrical of current speeds. The flux of suspended particulate matter concentration and current speeds were transported to southeastern direction of surface layer and northwestern direction of bottom layer at the western area at line A of Gwangyang Bay. Small suspended particles have been found to increase attenuation and transmission more efficiently than similar large particles using acoustic intensity (ADV/ADCP) or optical transmit coefficient (LISST-100/Transmissometer). The application and problems as using optical or acoustic instruments will be detected for use in time varying calibrations to account for non-negligible changes in complex environments in situ particle dynamics are poorly understood.

Spray Characteristics of the Pressure Swirl Injector for the APU Gas Turbine Engine (APU 가스터빈엔진 압력식 스월인젝터의 분무특성)

  • Choi, Chea-Hong;Choi, Seong-Man;Lim, Byeong-Jun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.359-364
    • /
    • 2007
  • Spray characteristics of the APU gas turbine engine were investigated. In order to understand blow out phenomena of the APU engine, we performed fuel spray test. In the test, four operating conditions such as sea level idle, sea level max power, 20,000 feet idle, 20,000 feet max power were used as spray experimental conditions. PDPA(phase Doppler Particle Analyzer) was used for measuring the particle diameter and velocity. Also spray visualization was performed by using ND-YAG sheet laser beam. From the test result, in the case of 20,000 feet idle condition, SMD is about 100 ${\mu}m$ and maximum particle velocity is about 10 m/s. For the flame stability, spray quality should be improved at 20,000 feet idle condition.

  • PDF

Numerical Investigation of Collection Efficiency of Virtual Impactor with Electro-Aerodynamic Lens (전기-공기역학적 렌즈를 이용한 가상임팩터 포집효율에 관한 수치적 연구)

  • Zahir, Muhammad Zeeshan;Yook, Se-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.7
    • /
    • pp.63-70
    • /
    • 2019
  • An electro-aerodynamic lens for improving the performance of virtual impactor has been proposed in this study. ANSYS FLUENT Release 16.1 was used for numerical analysis of virtual impactor with and without the electro-aerodynamic lens, used to collimate the incoming aerosol particles into a particle beam before injecting the particles into the virtual impactor. Particles supplied to the electro-aerodynamic lens were assumed to be highly charged. By using an aerodynamic lens before the virtual impactor, without any electrostatic effect, it was found that the cut-off diameter of the virtual impactor was reduced from $4.2{\mu}m$ to $0.68{\mu}m$ and that the fine particle contamination problem became more serious. However, by employing the combined electrostatic and aerodynamic effects, that is, by applying electric voltage potential to the electro-aerodynamic lens, the cut-off diameter was found to be further reduced to $0.45{\mu}m$ and the fine particle contamination was eliminated.

하이브리드 SEM 시스템

  • Kim, Yong-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.109-110
    • /
    • 2014
  • 주사전자현미경(Scanning Electron Microscopy: SEM)은 고체상태에서 미세조직과 형상을 관찰하는 데에 가장 다양하게 쓰이는 분석기기로서 최근에 판매되고 있는 고분해능 SEM은 수 나노미터의 분해능을 가지고 있다. 그리고 SEM의 초점심도가 크기 때문에 3차원적인 영상의 관찰이 용이해서 곡면 혹은 울퉁불퉁한 표면의 영상을 육안으로 관찰하는 것처럼 보여준다. 활용도도 매우 다양해서 금속파면, 광물과 화석, 반도체 소자와 회로망의 품질검사, 고분자 및 유기물, 생체시료 nnnnnnnnn와 유가공 제품 등 모든 산업영역에 걸쳐 있다(Fig. 1). 입사된 전자빔이 시료의 원자와 탄성, 비탄성 충돌을 할 때 2차 전자(secondary electron)외에 후방산란전자(back scattered electron), X선, 음극형광 등이 발생하게 되는 이것을 통하여 topography (시료의 표면 형상), morphology(시료의 구성입자의 형상), composition(시료의 구성원소), crystallography (시료의 원자배열상태)등의 정보를 얻을 수 있다. SEM은 2차 전자를 이용하여 시료의 표면형상을 측정하고 그 외에는 SEM을 플랫폼으로 하여 EDS (Energy Dispersive X-ray Spectroscopy), WDS (Wave Dispersive X-ray Spectroscope), EPMA (Electron Probe X-ray Micro Analyzer), FIB (Focus Ion Beam), EBIC (Electron Beam Induced Current), EBSD (Electron Backscatter Diffraction), PBMS (Particle Beam Mass Spectrometer) 등의 많은 분석장치들이 SEM에 부가적으로 장착되어 다양한 시료의 측정이 이루어진다. 이 중 결정구조, 조성분석을 쉽고 효과적으로 할 수 있게 하는 X선 분석장치인 EDS를 SEM에 일체화시킨 장비와 EDS 및 PBMS를 SEM에 장착하여 반도체 공정 중 발생하는 나노입자의 형상, 성분, 크기분포를 측정하는 PCDS(Particle Characteristic Diagnosis System)에 대해 소개하고자 한다. - EDS와 통합된 SEM 시스템 기본적으로 SEM과 EDS는 상호보완적인 기능을 통하여 매우 밀접하게 사용되고 있으나 제조사와 기술적 근간의 차이로 인해 전혀 다른 방식으로 운영되고 있다. 일반적으로 SEM과 EDS는 별개의 시스템으로 스캔회로와 이미지 프로세싱 회로가 개별적으로 구현되어 있지만 로렌츠힘에 의해 발생하는 전자빔의 왜곡을 보정을 위해 EDS 시스템은 SEM 시스템과 연동되어 운영될 수 밖에 없다. 따라서, 각각의 시스템에서는 필요하지만 전체 시스템에서 보면 중복된 기능을 가지는 전자회로들이 존재하게 되고 이로 인해 SEM과 EDS에서 보는 시료의 이미지의 차이로 인한 측정오차가 발생한다(Fig. 2). EDS와 통합된 SEM 시스템은 중복된 기능인 스캔을 담당하는 scanning generation circuit과 이미지 프로세싱을 담당하는 FPGA circuit 및 응용프로그램을 SEM의 회로와 프로그램을 사용하게 함으로 SEM과 EDS가 보는 시료의 이미지가 정확히 일치함으로 이미지 캘리브레이션이 필요없고 측정오차가 제거된 EDS 측정이 가능하다. - PCDS 공정 중 발생하는 입자는 반도체 생산 수율에 가장 큰 영향을 끼치는 원인으로 파악되고 있으며, 생산수율을 저하시키는 원인 중 70% 가량이 이와 관련된 것으로 알려져 있다. 현재 반도체 공정 중이나 반도체 공정 장비에서 발생하는 입자는 제어가 되고 있지 않은 실정이며 대부분의 반도체 공정은 저압환경에서 이루어지기에 이 때 발생하는 입자를 제어하기 위해서는 저압환경에서 측정할 수 있는 측정시스템이 필요하다. 최근 국내에서는 CVD (Chemical Vapor Deposition) 시스템 내 파이프내벽에서의 오염입자 침착은 심각한 문제점으로 인식되고 있다(Fig. 3). PCDS (Particle Characteristic Diagnosis System)는 오염입자의 형상을 측정할 수 있는 SEM, 오염입자의 성분을 측정할 수 있는 EDS, 저압환경에서 기체에 포함된 입자를 빔 형태로 집속, 가속, 포화상태에 이르게 대전시켜 오염입자의 크기분포를 측정할 수 있는 PBMS가 일체화 되어 반도체 공정 중 발생하는 나노입자 대해 실시간으로 대처와 조치가 가능하게 한다.

  • PDF

Stabilization of Nanoemulsion Using PEG-free Surfactant (PEG-free 계면활성제를 사용한 Nanoemulsion의 안정화)

  • Kim, Huiju;Jung, Taek Kyu;Kim, Ja Young;Yoon, Kyung-Sup
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.434-447
    • /
    • 2019
  • Polyethylene glycol (PEG) is widely used in cosmetics as a surfactant, detergent and emulsifier. During the manufacturing process, 1,4-dioxane, which is toxic to humans, can be produced as a by-product by dimerization of ethylene oxide. As consumers' interest in cosmetic ingredients has increased, the need for safe emulsion research without PEG ingredients in the personal care market has increased. With increasing consumer interest in cosmetic ingredients, the need for safer emulsion research without the PEG ingredient in the personal care market has increased. In this study, we aimed to develop and stabilize nanoemulsion formulation without PEG. Response Surface Methodology (RSM) was used to develop optimized nanoemulsion formulations. Surfactant content (2~4%), oil content (4~8%) and polyol content (12~24%) were set as independent variables as a result of preliminary experiments for determining independent variables and ranges. The particle size, zeta potential, turbidity, and polydispersity index of the formulation were measured as response variables. As a result of measurement of the prepared nanoemulsion by FIB (Focused ion beam), spherical particles were found to have a size distribution of 100 to 200 nm. The stability of each formulation was evaluated for 30 days at each temperature ($4^{\circ}C$, $25^{\circ}C$, and $45^{\circ}C$). The optimal formulation considering the optimum particle size, turbidity, polydispersity index and zeta potential was found to be surfactant (2%), oil (8%) and polyol (24%).

Effects of atmospheric turbulence on the laser cross-beam velocimeter (레이저 크로스빔 속도계에 대한 대기교란 효과)

  • sung pyung-shik
    • Journal of the Korea Computer Industry Society
    • /
    • v.6 no.2
    • /
    • pp.259-264
    • /
    • 2005
  • This paper have derived an expression(the fringe modle is used) for the photocurrelation-correlation function for a cross-beam laser velocimeter, taking into account the effects of atmospheric turbulence on the amplitude and phase of the incident beams. the result, as long as the atmospheric disturbances do not greatly damp out sinusoidal variations of the photocurrent-correlation function in the time it takes a particle to travel the fringe-separation distance, the disturbances do not hinder the determination of the velocity of the partides from the correlation funtion.(the scattering particles are assumed to have a well-defined V).

  • PDF

The Study on Two-color PIV Algorithm for a Measurement of Droplet Velocity (액적의 속도 측정을 위한 이색 PIV 알고리즘 연구)

  • Lee, K.H.;Lee, C.S.;Oh, S.I.
    • Journal of ILASS-Korea
    • /
    • v.4 no.1
    • /
    • pp.13-18
    • /
    • 1999
  • It has been known that spray characteristics have an important effect on the mixture formation and directly influence the engine performances and the emissions. Up to now, the measurement of droplet size is well developed such as PDPA and PMAS though the behavior of small droplets during secondary atomization is not clear. Particle image velocimetry(PIV), a planar measuring technique, is a very efficient tool for studying complicated behavior and a fast and reliable method to track numerous droplets during injection. In this study, two-color scanning PIV is designed to obtain quasi-instantaneous two dimensional velocity data by using he-ion laser, rotating mirror and beam splitter. This PIV method which has high temporal and spatial resolution provides the information about the small complex droplet behavior.

  • PDF