• Title/Summary/Keyword: Particle Filters

Search Result 231, Processing Time 0.026 seconds

A performance analysis of terrain-aided navigation(TAN) algorithms using interferometric radar altimeter (간섭계 레이더 고도계를 활용한 지형참조항법의 성능 분석)

  • Jeong, Seung-Hwan;Yoon, Ju-Hong;Park, Min-Gyu;Kim, Dae-Young;Sung, Chang-Ki;Kim, Hyun-Suk;Kim, Yoon-Hyung;Kwak, Hee-Jun;Sun, Woong;Yoon, Kuk-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.4
    • /
    • pp.285-291
    • /
    • 2012
  • The paper experimentally verifies the performance of Terrain-Aided Navigation (TAN) using an interferometric radio altimeter, which is recently used due to its accuracy. First, we propose a TAN system that utilizes an interferometric radio altimeter as a measurement system. Second, we implement extended Kalman filter, unscented Kalman filter, and particle filter to evaluate the performance of TAN according to the selection of filters and the difference of environments.

A Study on the Air Pollution Component in Hwasoon Nulitjae Tunnel (화순너릿재 터널내의 대기오염성분에 관한 조사연구)

  • 신대윤;송금섭;김정규;송연호;임만택
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.3
    • /
    • pp.52-57
    • /
    • 1993
  • This study was carried out to investigate the air pollution in Hwasoon Nulitjae tunnel for two months, from August 1992 to September 1992. The total suspended particles were collected by high volume air sampler at inside and outside of Hwasoon Nulitjae tunnel, of which major water soluble component and heavy metalic element were analyzed. Size distribution and respirable mass fraction of aerosol at inside were measured by filters on nine stages Andersen air sampler. The average concentration of TSP at inside was 657.57 $\mu$g/m$^3$, which appeared about 9.2 times as high as that of 71.47 $\mu$g/m$^3$ at outside. The decrease effect caused by using new tunnel was 31.2%. As a result of correlation analysis between concentration of TSP at inside of Hwasoon Nulitjae tunnel and that at outside, correlation coefficient was 0.713. The average concentrations of SO$_4^{2-}$ , NO$_3^-$, CI$^-$ were 43.02 $\mu$g/m$^3$, 19.86 $\mu$g/m$^3$, 4.96 $\mu$g/m$^3$, those of NH$_4^+$, Na$^+$, K$^+$ 1.42 $\mu$g/m$^3$, 4.45 $\mu$g/m$^3$, 2.89 $\mu$g/m$^3$ and those of Ca$^{2+}$, Mg$^{2+}$, Pb$^{2+}$ 3.92 $\mu$g/m$^3$, 2.27 $\mu$g/m$^3$. 1.52 $\mu$g/m$^3$, respectively. It was estimated that mass fraction rate of respirable particle at inside was about 84.54% of aerosol. The average concentration of suspended particle to be collected by Andersen sampler was 478.90 $\mu$g/m$^3$, this was about 72.8% of that by high volume air sampler.

  • PDF

An experimental study on the filtration test of cotton ball filters (코튼볼 여재의 여과 특성 실험 연구)

  • Kim, Sunghong;Kim, Heejun;Kim, Donghan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.1
    • /
    • pp.79-86
    • /
    • 2019
  • In order to measure the filtration characteristics of a cotton ball shape filter, the experiments of suspended solids(SS) surrogate material selection and filtration performance have been carried out in this study. Between the two materials of powdered activated carbon(PAC) and powdered red-clay, PAC is more suitable surrogate material in terms of experimental criteria and particle size distribution in the non-point source pollutants removal system. As a result of the filtration experiments with the cotton ball shape filter, the initial headloss was about 8 cm, and the headloss slightly increased over filtration time. The Kozeny-Carman equation was used to analyze the changes of pressure and porosity during the filtration. The initial porosity was calculated as 0.945 and it decreased to 0.936 at the end of design filtration time. As the filtration continued, the SS concentration of the filtered water gradually increased and the SS removal rate gradually decreased. When the SS target removal efficiency is assumed to be 80%, the cumulative SS removal capacity is expected as $28.8kg/m^2$. This means the volume loading rate of the cotton ball shape filter can be $115m^3/m^2$ when the typical SS concentration of non-point source water pollution is assumed as 250 mg/L.

Airborne infection risk of respiratory infectious diseases and effectiveness of using filter-embeded mechanical ventilator and infectious source reduction device such as air cleaner (실내 공간에서의 호흡기 감염병 공기전파감염 위험도와 공기정화장치(필터 임배디드 기계식 환기설비 및 공기청정기 등 실내 감염원 저감 장치) 사용에 따른 효율)

  • Park, Sungjae;Park, Geunyoung;Park, Dae Hoon;Koo, Hyunbon;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.16 no.4
    • /
    • pp.73-94
    • /
    • 2020
  • Particulate infectious sources, including infectious viruses, can float in the air, causing airborne infections. To prevent indoor airborne infection, dilution control by ventilation and indoor air cleaners are frequently used. In this study, the risk of airborne infection by the operation of these two techniques was evaluated. In case of dilution control by ventilation, a high efficiency air filter was embedded at the inlet of supply air. In this study, infectious source reduction devices such as indoor air cleaner include all kinds of mechanical-filters, UV-photo catalysts and air ionizers through which air flow is forced by fans. Two mathematical models for influenza virus were applied in an infant care room where infants and young children are active, and the risk reduction efficiency was compared. As a result, in the case of individually operating the ventilator or the infectious source reduction device, the airborne infection risk reduction efficiencies were 55.2~61.2% and 53.8~59.9%, respectively. When both facilities were operated, it was found that the risk of airborne infection was reduced about 72.2~76.8%. Therefore, simultaneous operation of ventilation equipment and infectious source reduction device is the most effective method for safe environment that minimizes the risk of airborne infection of respiratory infectious diseases. In the case of a space where sufficient ventilation operation is difficult, it was found that the operation of an infectious source reduction device is important to prevent the spread of infectious diseases. This study is meaningful in that it provides an academic basis for strategies for preventing airborne infection of respiratory infectious diseases.

Measurement of Airborne Particles and Volatile Organic Compounds Produced During the Heat Treatment Process in Manufacturing Welding Materials

  • Myoungho Lee;Sungyo Jung;Geonho Do;Yeram Yang;Jongsu Kim;Chungsik Yoon
    • Safety and Health at Work
    • /
    • v.14 no.2
    • /
    • pp.215-221
    • /
    • 2023
  • Background: There is little information about the airborne hazardous agents released during the heat treatment when manufacturing a welding material. This study aimed to evaluate the airborne hazardous agents generated at welding material manufacturing sites through area sampling. Methods: concentration of airborne particles was measured using a scanning mobility particle sizer and optical particle sizer. Total suspended particles (TSP) and respirable dust samples were collected on polyvinyl chloride filters and weighed to measure the mass concentrations. Volatile organic compounds and heavy metals were analyzed using a gas chromatography mass spectrometer and inductively coupled plasma mass spectrometer, respectively. Results: The average mass concentration of TSP was 683.1±677.4 ㎍/m3, with respirable dust accounting for 38.6% of the TSP. The average concentration of the airborne particles less than 10 ㎛ in diameter was 11.2-22.8×104 particles/cm3, and the average number of the particles with a diameter of 10-100 nm was approximately 78-86% of the total measured particles (<10 ㎛). In the case of volatile organic compounds, the heat treatment process concentration was significantly higher (p < 0.05) during combustion than during cooling. The airborne heavy metal concentrations differed depending on the materials used for heat treatment. The content of heavy metals in the airborne particles was approximately 32.6%. Conclusions: Nanoparticle exposure increased as the number of particles in the air around the heat treatment process increases, and the ratio of heavy metals in dust generated after the heat treatment process is high, which may adversely affect workers' health.

Permeability Reduction of Soil Filters due to Physical Clogging (물리적 폐색으로 인한 흙필터의 투수능 저하)

  • ;;;;Reddi, L. N.
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.1
    • /
    • pp.15-24
    • /
    • 2001
  • 흙필터는 일반적으로 침식이나 파이핑으로부터 지반 구조물을 보호하기 위하여 사용된다. 세립자들이 유동하여 필터에 퇴적하는 폐색현상이 발생하는 경우, 간극수압이 증가하고 이로 인해 지반구조물의 불안정을 유발시키게 된다. 미세입자의 유동에 의한 폐색현상은 옹벽의 뒤채움재에 설치한 필터, 흙댐의 저부에 설치된 필터, 그리고 터널의 라이닝 뒤에 설치한 필터 등에서 발생할 수 있다. 폐색현상은 필터의 투수능을 저하시켜 배수능력에 상당한 위험을 초래할 수 있다. 본 연구에서는 필터의 폐색으로 인한 투수능 저하 정도를 실험을 통해 관찰하고 이론적인 모델을 통해 정량화 시키고자 하였다. 일정한 농도의 현탁액이 필터로 유입되는 분리형 실험과 현장상태를 모사하는 흙-필터 시스템의 결합형 실험을 통해 투수능의 저하현상이 압력 제어조건과 유량 제어조건에서 관찰되었고, 서로 비교 분석되었다. 미세입자가 통과하는 필터의 간극을 모세관으로 가정한 후 모세관에서 유체의 흐름 원리를 이용하여 물리적인 폐색에 의해 발생하는 투수능 저하현상을 이론적인 모델로 구성하였다. 일반적으로 투수능은 1/10 수준으로 감소되었으며, 분리형 실험에 의한 결과와 이론적인 모델의 결과는 잘 일치하였다. 또한, 결합형 실험결과와 분리형 실험결과가 비교적 잘 일치하여 투수능 저하예측은 분리형 실험이나 이론적 모델에 의하여 가능하리라 판단되었다.

  • PDF

Changeable Qualitative Characteristics of Mold Aerosols on Each Occasion of Dust Episodes (2000 ~ 2002) in West Korea

  • Yeo, Hwan-Goo
    • Korean Journal of Environmental Biology
    • /
    • v.21 no.3
    • /
    • pp.240-244
    • /
    • 2003
  • Conidia of molds within the Asian dust were captured in the ambient air of mid-west Korea, in springtime of 2000~2002. An eight-stage Cascade impactor and 0.22 $\mu\textrm{m}$ pore size membrane filters were used for the dust samples. Several kinds of molds grown from the samples were identified to the genus level. Those are Aspergillus, Basipetospora, Epicoccum, Fusarium, Monotospora and Penicillium. Relatively diversified mycelia of hyphomycetes were grown on the fine dust sample (1.1~2.1 $\mu\textrm{m}$) in the first year Asian dust episode (23~24 March, 2000). On the other hand, some fluffy molds and dark molds aggregations were grown on even the backup particle sample less than 0.43 $\mu\textrm{m}$ during the second year episode (24~26 April, 2001). The result of the last year episode (21~22 March, 2002) showed various mycelia grown on the sample contained from 1.1 to 2.1 $\mu\textrm{m}$ sized particles, just like the result of the first year episode (23~24 March, 2000). These variations between the episodes might be caused by the difference of the dust origins.

A Study on the Coarse Particles Burden to Aerosol in Seoul Area (粗大粒子가 大氣淨遊粉塵에 주는 負荷)

  • 이윤재;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.1 no.1
    • /
    • pp.71-82
    • /
    • 1985
  • The effect on the particulate matters in the atmosphere was investigated in Seoul area from March, 1984 to Aprill, 1985. Aerosols were collected by filters on nine stages Andrsen Air Sampler, and size distribution and total concentration of the aerosols, Fe and Pb were measured. In spring with Yellow Sand the concentration of particles in aerosols was 185.55$\mug/m^3$ and CP/TA was 65.9%. But in spring without Yellow Sand those of particles was 135.45$\mug/m^3$ and CP/TA was 58.6%. Accordingly the concentration of coarse particles with Yellow Sand was higher than without them in Spring. Above results indicate that in Seoul Area the main source of air pollution originated from natural burdens, especially from soil. The concentration of Pb was similarly valued through both seasons in Seoul area but fine particles valued above coarse particles. On the other hand, in urban area, the natural and anthropogenic sources have influenced on the concentration of Pb. With referred to particle size distribution for Fe, the concentration of coarse particles was 0.168$\etag/m^3$ (CP/TA: 74.3%) in Spring with Yellow Sand, 0.096$\mug/m^3$ (CP/TA: 71.6%) without Yellow Sand and 0.083$\mug/m^3$ (CP/TA: 67.4%) in winter, respectively. Compared with fine particles, all of them were higher. It indicated that the origin of coarse particles in urban air was not related to anthropogenic source. The concentration of Fe was influenced by Yellow Sand and contributed to air pollution.

  • PDF

Change in Cell Size and Buoyant Density of Pseudomonas diminuta in Response to Osmotic Shocks

  • Lee, So-Hee;Cho, Yu-Ree;Choi, Yong-Jin;Kim, Chan-Wha
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.2
    • /
    • pp.326-328
    • /
    • 2001
  • Pseudomonas diminuta (ATCC 19146) has been typically used in the bacterial challenge test for validation of the sterilizing filtration process. Cell size is critical for determining the retention characteristics of membrane filters with pore-size of $0.2{\mu}m$. The changes of cell sizes after osmotic shocks at 150, 260, 500, and 700 mosM were measured by a particle size analyzer and the changes of their buoyant densities were analyzed with a Percoll gradient. The results indicated that there were no significant differences when cells were cultured in 260 mosM medium and osmotically shocked at 500 and 700 mosM. However, the osmotically shocked cells at 150 mosM showed a 38% increase of the cell size compared to the cells at 260 mosM. From these study, we concluded that the worst case condition for validation of a sterilizing filter would be 500 mosM, not because of changes in the cell size, but due to decrease in cell viability under those conditions.

  • PDF

A Study on the Volatilization of Particulate Nitrate (NO3-) During Fine Particle (PM2.5) Measurement (미세입자(PM2.5) 측정시 발생되는 질산염(NO3-) 휘발에 관한 연구)

  • 강병욱;이학성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.4
    • /
    • pp.297-303
    • /
    • 2002
  • Fine particles (d$_{p}$ < 2.5 $\mu$m) were measured using an annular denuder system (ADS) in Chongju. The data set was collected on fifty-eight different days with a 24-hr sampling period from October 27, 1995 through August 25, 1996. Particulate nitrate in the ADS was also measured on teflon and nylon filters in series behind denuders to collect HNO$_3$, HNO$_2$, SO$_2$and NH$_3$. From this study. the mean concentration of particulate nitrate of PM$_{2.5}$ in the ADS were seen with the following order: winter (5.05) >fall (4.36) >spring (3.92) > summer (1.10 $\mu\textrm{g}$/㎥). Nitrate losses, which calculated from the ratio of nylon filter nitrate to the sum of teflon and nylon filter nitrates, varied in the following manner summer (72.2%) > spring (42.6%) > fall (23.5%)> winter (0.4%). Especially, gaseous nitric acid was dominant at temperature higher than 8$^{\circ}C$ while particulate nitrate was major species in total nitrate below that temperature. This indicates the particulate nitrate loss is strongly correlated rather with ambient temperature.e.e.