• 제목/요약/키워드: Particle Counter

검색결과 211건 처리시간 0.024초

진공 환경내 실시간 입자 모니터링 시스템의 개발 및 성능평가 (Development and Performance Test of In-situ Particle Monitoring System using Ion-counter in Vacuum Environments)

  • 안강호;김용민;권용택
    • 반도체디스플레이기술학회지
    • /
    • 제5권1호
    • /
    • pp.45-49
    • /
    • 2006
  • In this paper, a new method that monitors the quantity of particles using ion-counter in vacuum environment is introduced. In-situ particle monitoring (ISPM) system is composed by Gerdien type ion-counter (house-made), DC power supply and electrometer. The ion-counter applied by positive voltage detects only positive charged particles. Therefore the particles to be detected should be in known charge state for further data analysis. ion-counter is installed at the exhaust line of process equipment where the pressure loss is structurally low. ISPM system performance has been verified with SMPS (Scanning Mobility Particle Sizer) system. The correlation coefficient is above 0.98 at the particle size range of $20{\sim}300nm$ in diameter with identified charge distribution under $0.1{\sim}10.0$ Torr.

  • PDF

드론을 이용한 안면도 상공 대기경계층내의 미세먼지 연직분포 및 Flux 측정 (Vertical Aerosol Distribution and Flux Measurement in the Planetary Boundary Layer Using Drone)

  • 김희상;박용희;김우영;은희람;안강호
    • 한국입자에어로졸학회지
    • /
    • 제14권2호
    • /
    • pp.35-40
    • /
    • 2018
  • Vertical particle size distribution, total particle concentration, wind velocity, temperature and humidity measurement was performed with a drone. The drone was equipped with a wind sensor, house-made optical particle count(Hy-OPC), condensation particle counter(Hy-CPC), GPS, Temperature, Relative Humidity, Pressure and communication system. Base on the wind velocity and the particle size vertical distribution measurement with drone, the particle mass flux was calculated. The vertical particle distribution showed that the particle number concentration was very strongly correlated with the relative humidity.

한반도 상공의 응결핵 연구를 위한 기상항공기 나라호의 응결핵입자계수기 개선 및 관측 (Improvement and Observation of Condensation Particle Counter in Atmospheric Research Aircraft NARA for Condensation Particle Research in Korea)

  • 정운선;구정모;김민성;신혜민;고아름;장기호;차주완;이용희
    • 한국환경과학회지
    • /
    • 제31권9호
    • /
    • pp.803-813
    • /
    • 2022
  • In this study, we improved the water-based condensation particle counter in Atmospheric Research Aircraft NARA and investigated the condensation particle number concentration over the Korean peninsula. Pump and set point information were changed to improve the instrument used by aircraft for observation. Ground-based observational result showed that the error between two instruments, which are water-based condensation particle counter and butanol-based condensation particle counter, was 4.7%. Aerial observational result revealed that the number concentration before improvement indicate large variation with unstable condition, whereas the number concentration after improvement indicate a reasonable variation. After improvement, the number concentration was 706±499 particle/cm3 in the West Sea and 257±80 particle/cm3 in Gangwon-do, and these are similar to the concentration range reported in previous studies. Notably, this is the first attempt to use aerial observation with water-based condensation particle counter to investigate condensation particle number concentration.

정수처리공정에서의 입자분석 적용방안 (Application of Particle Counter in Water Treatment Process)

  • 신상희;전현숙;이찬형;배기수
    • 한국물환경학회지
    • /
    • 제29권3호
    • /
    • pp.337-342
    • /
    • 2013
  • The particle counter compared with the turbidimeter provides good precision and sensitivity and can get the characteristics of particulates effectively. The purpose of this study is to provide the application of particle counter in sand and activated carbon filters. The particle count by size could be more easily sense when the water quality is changed by the influent of high turbidity or algae. We could decide the optimal backwashing cycles and detect the efficiencies of filters by monitoring the total particle count of effluent in sand and activated carbon filters.

정수처리 공정에서 연속식 입자계수기의 적용성 검토에 관한 연구 (Discussion of Problems During the Application of the On-line Particle Counter In Water Treatment Process)

  • 문성용;김승현
    • 상하수도학회지
    • /
    • 제19권2호
    • /
    • pp.214-220
    • /
    • 2005
  • Errors may occur due to analysis methods and water quality during the application of the on-line particle counter In water treatment process. Errors caused by analysis methods include particle destruction by shear force due to inflow speed and tube friction, as well as interruption by screening, bubbles and contaminants. Since errors happen frequently because of these factors, it is necessary to examine and evaluate such errors during the application of a particle counter. Errors can be large due to screening and bubbles. Measurement values are effective for water analysis after filtration process. However, because of screening, only measurement values for particles above $7{\mu}m$ are valid for water with a turbidity between 3-10NTU. As particle numbers around $10{\mu}m$ increase a lot after ozone treatment, sufficient pretreatment process is necessary. Physical conditions should keep stable for inflow to decrease errors caused by shear force.

미세 입자 계수기를 위한 입자 검출 챔버 개발 (Development of Particle Detection Chamber for Particle Counter)

  • 엄우용
    • 전자공학회논문지
    • /
    • 제51권1호
    • /
    • pp.219-224
    • /
    • 2014
  • 본 논문에서는 미세 입자의 크기와 굴절률, 그리고 레이저 파장과 산란광을 얻는 수신단의 각도 등 여러 변수에 대하여 Mie 산란 이론을 적용하여 미세 입자의 산란 특성에 대하여 연구하였고, 이를 바탕으로 미세 입자 검출을 위한 광학계를 구성하고 산란 신호를 획득하여 그 특성을 분석하였다. 그리고 이러한 특성들을 바탕으로 미세 입자 검출기를 위한 입자 검출 챔버를 개발하고 성능을 분석한다.

광학 입자 계수기의 응답특성 및 오계수에 관한 연구 (A Study of Response Characteristics and False Counts in Optical Particle Counter)

  • 안강호;이재헌
    • 대한기계학회논문집
    • /
    • 제16권3호
    • /
    • pp.547-554
    • /
    • 1992
  • 본 연구에서는 Climet사의 백색광원 OPC인 CI226와 PMS사의 laser 광원 OPC인 LAS-X 및 HS-LAS의 응답특성을 측정하여 제작사가 제시한 응답특성과 비교하여 그 정 확성을 논하였으며 아울러 고유량(high flow rate) Clean Room용 OPC인 Climet CI- 7300, Met One 200, Hiac/Royco5120 등 3가지 장치에 관한 오계수의 원인을 박히고자 하였다.

입자계수기를 이용한 생물활성탄 공정의 효율평가 (Evaluation of Biological Activated Carbon Using Particle Counter)

  • 김희근;류동춘;김현실;류병순;문성용;김승현;김원경
    • 상하수도학회지
    • /
    • 제20권6호
    • /
    • pp.823-828
    • /
    • 2006
  • For this study, an online particle counter was installed before and after the activated carbon filtration process of D water treatment plant where has advanced water treatment processes, produces average 900,000ton/day of drinking water and supply the produced drinking water to Busan citizens. We collected and analyzed particle count data for about 1 year. We inspected particle breakthrough in three out of sixteen filter processes operated at same conditions, i.e. 5th filter, 6th filter and 7th filter. According to the monitoring results, 6th and 7th filters showed similar results while 5th filter showed different results. When compared seasonal effect, the particle count for dry season was below 10 particles/ml while the particle count for August when monthly average rainfall is over 200mm was much higher than for dry season. In January and August, there was a difference in breakthrough particle size. In January, small particles in 2~3um were mainly detected while in August 10um particles were mainly detected and the size distribution was 40% of total count.

Spatiotemporal behavior of excited Xe atoms density in Counter discharged type AC-PDP

  • Hong, Young-June;Oh, Phil-Yong;Jeong, Se-Hoon;Hong, Jong-Hwa;Kim, Jung-Hyun;Gyu, Yong;Cho, Seok-Ho;Hong, Sung-Hee;Hong, Byoung-Hee;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.574-577
    • /
    • 2007
  • We have measured the excited Xe atoms density in the $1s_5$ metastable states by laser absorption spectroscopy in counter discharged type AC-PDP. This experiment has shown the characteristic of the excited Xe atoms density which is relation to the visible light efficiency of PDP. The density of counter discharged AC-PDP have measured to be $9.47\;{\times}\;10^{13}\;cm{-3}$. The result has been shown to higher value than $1.45\;{\times}\;10^{13}\;cm^{-3}$ of conventional AC-PDP.

  • PDF