• 제목/요약/키워드: Particle Collection

검색결과 307건 처리시간 0.021초

사이클론 내 유동특성 및 미세입자 집진효율에 대한 수치해석적 연구 (A Numerical Analysis on the Flow Characteristics and the Collection Efficiency for Fine Particles in a Cyclone)

  • 용정권;김창녕;조영민
    • 설비공학논문집
    • /
    • 제20권2호
    • /
    • pp.144-153
    • /
    • 2008
  • A numerical analysis has been carried out to examine the flow characteristics and the collection efficiency for fine particles in a cyclone using Computational Fluid Dynamics (CFD) technique. The cyclone with the cylinder diameter of 60 mm has been considered for the investigation of the particle collection in a relatively smaller cyclone with somewhat higher inlet air velocities. Fundamental air flow patterns for different inlet velocities have been calculated and then the motions of particles of different sizes have been obtained. The calculated collection efficiencies for fine particles are compared with the experimental results, which shows a good agreement. The current result can be used for the design of cyclones with high collection efficiency.

운전조건에 따른 전기집진장치의 특성관계 연구 (A Study on the Characteristics for Electrostatic Precipitator by Operating Conditions)

  • 하상안;김일배
    • 한국환경보건학회지
    • /
    • 제24권2호
    • /
    • pp.145-150
    • /
    • 1998
  • This study was carried out to investigate the loss amount of collection at the different of precipitatation time, high voltage and gas speed. This work has focused on the dependence of the collection efficiency in the collector zone with gas speed and high voltage. This advanced Model is developed by research of the different parameter as the conventionnal modem of study. In order to investigate collection efficiency of electrostatic precipitator, the loss amount of knocking was measured with Monitek-Treubung and the particle size was analyzed by He-Ne laser diffraction spectroscopy.

  • PDF

2003년부터 2015년까지 CA 인증 공기청정기의 성능 시험 결과 분석 (Analysis of performance test results of CA-certified air cleaners from 2003 to 2015)

  • 김학준;홍기정;우창규;한방우;김용진
    • 한국입자에어로졸학회지
    • /
    • 제13권1호
    • /
    • pp.17-23
    • /
    • 2017
  • In this study, the test results obtained from the performance tests for CA (Korea Association of Cleaning Air) certificated air cleaners which had been commercially available in Korea from 2003 to 2015 were analyzed. Among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level, noise level and CADR were correlated with flow rates. Collection and odor removal efficiencies were 20% higher than the limit of the CA certification. The ozone emissions from the air cleaners were negligible because all the air cleaners were equipped with only HEPA filters, not electrostatic precipitation method which produces ozone.

입자의 실시간 관측이 가능한 임팩터의 설계 및 성능해석 (Real -time Observation on Airborne Particles with Visual Impactor)

  • 육세진;안강호
    • 한국대기환경학회지
    • /
    • 제19권1호
    • /
    • pp.67-76
    • /
    • 2003
  • Recently consideration of health and interest on bio aerosols have been growing steadily. In this study, inertial impactor, which can be used to collect airborne particles and bio aerosols, was newly devised for real-time observation on the particles collected on impaction plate. and named Visual Impactor. Flow field and particle trajectory in the space between nozzle and impaction plate was analyzed numerically, and the collection effciencies were calculated. Calibration and performance evaluation of the Visual Impactor was conducted with polydisperse aerosols generated from 0.1% sodium chloride solution. Cut-off diameter from numerical simulation was in good agreement with that from experimental results. Because of particle bounce and particle deposition on nozzle tip due to short jet-to-plate distance, the collection efficiencies from numerical and experimental analyses were different slightly. Visual Impactor was used to collect airborne particles, and the features of collected particles could be seen in real-time. Airborne particles in different weather conditions (fine, cloudy, and rainy) were sampled and compared one another The features of collected airborne particles were dependent strongly upon relative humidity. In addition, with hours elapsing, shapes and colors of collected particles were changed by evaporation and surface tension, etc.

화학기상합성에 의해 제조된 $n-TiO_2$ 분말의 분말특성 (Powder Characteristics of $n-TiO_2$ Powder Synthesized by Chemical Vapor Synthesis)

  • 김혜경
    • 한국분말재료학회지
    • /
    • 제6권3호
    • /
    • pp.238-245
    • /
    • 1999
  • The preparation of $n-TiO_2$ powder by the Chemical Vapor Synthesis process (CVS) was studied using the liquid metal organic precursor (TTIP). The residence time and the collection methods were considered as main processing variables through the experiments. The CVS equipment consisted of a micropump and a flashvaporizer, a tube furnace and a tubular collection device. The synthesis was performed at $1000^{\circ}C$ with various sets of collection zone. The residence time and the total system pressure were controlled in the range of 3~20 ms and 10 mbar, respectively. Nitrogen adsorption, X-ray diffraction and electron microscopy were used to determine particle size, specific surface area and crystallographic structure. The grain size of the as-prepared $n-TiO_2$ powder was in the range of 2~8 nm for all synthesis parameters and the powder exhibited only little agglomeration. The relationship between particle characteristics and the processing variables is reviewed based on simple growth model.

  • PDF

단일 전하로 하전된 단일 섬유에서의 미세입자의 초기 집진효율에 관한 이론적 연구 (A Theoretical Study on the Initial Collection Efficiency of Submicron Particles by a Unipolar Charged Fiber)

  • 오용학;전기준;정용원
    • 한국대기환경학회지
    • /
    • 제17권3호
    • /
    • pp.259-268
    • /
    • 2001
  • In this study, we have developed a simulation method to predict the initial collection efficiency of a unipolar charged fiber in the electret filters. The particle sizes considered were in the submicron range and thus Brownian motion of particles was also taken into consideration along with electrostatic forces acting on the particles. The simulation results were compared with other investigators experimental data on single fiber efficiency as well as with the calculated results using the existing correlations on single fiber efficiency. It has been shown that simulation results are in good agreement both with the experimental data with those predicted by the correlations.

  • PDF

공기 중 박테리아 포집을 위한 습식 사이클론의 CFD 해석을 이용한 설계 및 성능 평가 (Design and Performance Evaluation using Computational Fluid Dynamics (CFD) Analysis of Wetcyclones for the Collection of Airborne Bacteria)

  • 고현식;박정우;정지우;황정호
    • 한국입자에어로졸학회지
    • /
    • 제19권3호
    • /
    • pp.77-87
    • /
    • 2023
  • We present the development of a wetcyclone sampler designed for the sampling of airborne bacteria. The wetcyclone design involves a combination of two traditional cyclone shapes and computational fluid dynamics (CFD) analysis to validate its effectiveness in terms of pressure drop and collection efficiency. The wetcyclone exhibits a collection efficiency of over 90% for bacteria, specifically targeting Staphylococcus aureus. Additionally, the wetcyclone enables continuous bioaerosol sampling using a liquid medium (deionized water), demonstrating a concentration ratio exceeding >105 and a stable microbial recovery rate of 81.9%. The application of real-time quantitative polymerase chain reaction (qPCR) and the colony counting method ensures precise measurement of the concentration ratio and microbial recovery rate.

황산암모늄 주입에 따른 전기집진기(ESP)에서의 미세분진 제거 (A Study on Fine Particle Removal of ESP according to $(NH_4)_2SO_4$ Injection Rate)

  • 서정민
    • 한국환경과학회지
    • /
    • 제7권4호
    • /
    • pp.505-510
    • /
    • 1998
  • This study has been carried out to investigate Electrostatic Precipitator's(ESP) performance enhancement and removal efficiency of fine particle according to (NH4)2SO4injection rate. The following conclusions are derived from the these test results : 1) For plant condition cases, according to the variation of concentration agent [(NH4)2SO4]-10ppm, when inlet dust loading was 2g/m2. And when Inlet dust loading was 3g/m", that was increased to 98 19% 99.16% 99.23%, 99.58%, 2) It Is seen from thins experiments that the increasing 30ppm concentration of (NH4)2SO4 increase the collection efficiency and fine particle omission control.

  • PDF

전기집진기형 공기청정기의 미세 먼지 저감 특성에 관한 연구 (Characteristics of the Reduction of Fine Particles in an Indoor Air Cleaner Using Electrostatic Precipitation Technique)

  • 목영선;이호원
    • 한국산업융합학회 논문집
    • /
    • 제7권1호
    • /
    • pp.115-120
    • /
    • 2004
  • An indoor air cleaner consisting of a dielectric barrier discharge system and an electrostatic precipitator (ESP) was experimentally investigated. The function of the dielectric barrier discharge is to precharge particles by producing nonthermal plasma before indoor air enters ESP, leading to an enhancement in dust collection efficiency. The dependence of particle size distribution on the plasma discharge was examined to understand the mechanism of the particle precharging. The plasma discharge was found to increase the electrical force of the particles, rather than agglomerate them. Coarse particles in the range of 0.5 to $5.0{\mu}m$ were observed to be easily collected by this indoor air cleaner, and the present study laid emphasis on the removal of fine particles of $0.3{\mu}m$. The collection efficiency of the fine particles was largely enhanced by the plasma discharge.

  • PDF

1단 전기집진기에서 난류확산과 2차유동이 입자의 농도분포에 미치는 영향 (Effects of Turbulence Diffusion and Secondary Flows on the Particle Concentration Distribution in Single Stage ESP)

  • 정상현;김상수;김용진
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2271-2282
    • /
    • 1995
  • Numerical simulations for the effects of secondary flow and turbulence diffusion on the particle concentration distributions have been carried out for the single stage electrostatic precipitator. The electrohydrodynamic secondary flow, particle concentration distribution and collection efficiency have been evaluated as a function of dimensionless parameters such as Re, $N_{end}$, $P_{e}$ x. The results of simulations show that for increasing secondary flow intensity the concentration distribution is drastically deformed and collection efficiency is decreased which is more than due to turbulent diffusion.n.n.