• Title/Summary/Keyword: Partial scan

Search Result 110, Processing Time 0.031 seconds

Analysis of Acquisition Parameters That Caused Artifacts in Four-dimensional (4D) CT Images of Targets Undergoing Regular Motion (표적이 규칙적으로 움직일 때 생기는 4DCT 영상의 모션 아티팩트(Motion Artifact) 관련된 원인분석)

  • Sheen, Heesoon;Han, Youngyih;Shin, Eunhyuk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.243-252
    • /
    • 2013
  • The aim of this study was to clarify the impacts of acquisition parameters on artifacts in four-dimensional computed tomography (4D CT) images, such as the partial volume effect (PVE), partial projection effect (PPE), and mis-matching of initial motion phases between adjacent beds (MMimph) in cine mode scanning. A thoracic phantom and two cylindrical phantoms (2 cm diameter and heights of 0.5 cm for No.1 and 10 cm for No.2) were scanned using 4D CT. For the thoracic phantom, acquisition was started automatically in the first scan with 5 sec and 8 sec of gantry rotation, thereby allowing a different phase at the initial projection of each bed. In the second scan, the initial projection at each bed was manually synchronized with the inhalation phase to minimize the MMimph. The third scan was intentionally un-synchronized with the inhalation phase. In the cylindrical phantom scan, one bed (2 cm) and three beds (6 cm) were used for 2 and 6 sec motion periods. Measured target volume to true volume ratios (MsTrueV) were computed. The relationships among MMimph, MsTrueV, and velocity were investigated. In the thoracic phantom, shorter gantry rotation provided more precise volume and was highly correlated with velocity when MMimph was minimal. MMimph reduced the correlation. For moving cylinder No. 1, MsTrueV was correlated with velocity, but the larger MMimph for 2 sec of motion removed the correlation. The volume of No. 2 was similar to the static volume due to the small PVE, PPE, and MMimph. Smaller target velocity and faster gantry rotation resulted in a more accurate volume description. The MMimph was the main parameter weakening the correlation between MsTrueV and velocity. Without reducing the MMimph, controlling target velocity and gantry rotation will not guarantee accurate image presentation given current 4D CT technology.

Improvement of Signal Processing Circuit for Inspecting Cracks on the Express Train Wheel (고속 신호처리 회로에 의한 고속철도 차륜검사)

  • Hwang, Ji-Seong;Lee, Jin-Yi;Kwon, Suk-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.579-584
    • /
    • 2008
  • A novel nondestructive testing (NDT) system, which is able to detect a crack with high speed and high spatial resolution, is urgently required for inspecting small cracks on express train wheels. This paper proposes an improved signal processing circuits, which uses the multiple amplifying circuits and the crack indicating pulse output system of the previous scan-type magnetic camera. Hall sensors are arrayed linearly, and the wheel is rotated with static speed in the vertical direction to sensor array direction. Each Hall voltages are amplified, converted and immediately operated by using, amplifying circuits, analog-to-digital converters and $\mu$-processor, respectively. The operated results, ${\partial}V_H/{\partial}t$, are compared with a standard value, which indicates a crack existence. If the ${\partial}V_H/{\partial}t$ is larger than standard value, the pulse signal is output, and indicates the existence of crack. The effectiveness of the novel method was verified by examine using cracks on the wheel specimen model.

  • PDF

Effect of O2 Partial Pressure on AlOx Thin Films Prepared by Reactive Ion Beam Sputtering Deposition

  • Seong, Jin-Wook;Yoon, Ki-Hyun;Kim, Ki-Hwan;Beag, Young-Whoan;Koh, Seok-Keun
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.5
    • /
    • pp.364-369
    • /
    • 2004
  • The barrier and optical properties of AlO$_{x}$ thin films on polycarbonate deposited by Reactive Ion Beam Sputtering (RIBS) were investigated at different oxygen partial pressure. We measured the deposition rate of AlO$_{x}$ thin films. As the oxygen partial pres-sure increased, the deposition rate increased then decreased. The changes of deposition rate are associated with the properties of deposited films. The properties of deposited AlO$_{x}$ thin films were studied using X-ray Photoelectron Spectroscopy (XPS), Scan-ning Electron Microscopy (SEM), and Atomic Force Microscopy (AFM). Optimum deposition parameters were found for fabricat-ing aluminum oxide thin films with high optical transparency for visible light and low Oxygen Transmission Rate (OTR). The optical transmittance of AlO$_{x}$ thin film deposited on polycarbonate (PC) showed the same value of bare PC.bare PC.

Partial molar pregnancy and coexisting fetus with Turner syndrome: Case report and literature review

  • Park, Ji Eun;Park, Ji Kwon;Cho, In Ae;Baek, Jong Chul
    • Journal of Genetic Medicine
    • /
    • v.15 no.1
    • /
    • pp.43-47
    • /
    • 2018
  • Partial hydatidiform mole and coexisting fetus is a rare entity with antecedent high risk of maternal and fetal complications, and risk of persistent trophoblastic disease in later life. Here, we report a case of twin pregnancy with live fetus identified as 45,X and normal placenta and another partial mole. Ultrasound scan at 10 weeks showed a hydrops fetus with a focal area of multicystic placenta. The patient underwent chorionic villus sampling and amniocentesis for chromosomal analysis, and the result was 45,X. Based on these finding, the patient then underwent induced abortion. Pathological examination (immunohistochemical staining) of the placenta confirmed the partial mole. This report suggests that careful prenatal ultrasonography and appropriate karyotyping in a molar pregnancy and coexisting fetus enable early diagnosis and may be beneficial for prognosis.

Application of Photoacoustic Rapid Scan FTIR for the Determination of Kappa Number of Pulp

  • Dang Vinh Q.;Bhardwaj Nishi K.;Nguyen Kien L.
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.06a
    • /
    • pp.167-172
    • /
    • 2006
  • High-yield Pinus radiate kraft pulps with various Kappa number were produced from flow-through laboratory pulping. The samples were prepared and scanned using a rapid scan photoacoustic Fourier transform infrared (PAS-FTIR) spectrometer. A partial-least-squares (PLS) model was established based on the spectral data collected at different mirror velocities. The model was used to predict the Kappa number of the pulps and its robustness was statistically evaluated. The outcomes indicate that the PLS model can be used to predict the Kappa number of Pinus radiata kraft pulps with a high degree of accuracy provided that the moving mirror velocity is ${\leq}\;0.5cm/s$.

  • PDF

Comparison of digitalized fabrication method for interim removable partial denture: case reports (두 가지 프린팅 방식으로 제작한 임시 가철성 의치의 비교: 증례 보고)

  • Yoon-Jeong Shin;Cheong-Hee Lee;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.379-385
    • /
    • 2023
  • With the recent development of digital dentistry, fully digitalized methods for fabricating dentures, using intraoral scans and computer-aided design/computer-aided manufacturing (CAD-CAM), are getting popular. Digital methods have the advantage of simplifying the fabrication process in the clinic and laboratory, supplementing digital data. This case report shows a fully digital fabrication method for interim removable dentures in a patient with anterior tooth loss in which implant placement is impossible or delayed. Interim removable dentures were fabricated using two methods. One method is printing tooth and base parts separately and combining, and the other method is printing the whole denture at one time and coloring on the base part. Afterward, dentures were delivered and adaptation was evaluated using the triple scan technique. The extracted site was scanned intraorally (first scan) and the interim removable denture was digitally scanned both intraorally (second scan) and, after removal extraorally (Third scan). In both method, denture adaptation was shown favorable. We report this case report as both the patient and the operator were satisfied with a simplified process using a fully digital method in the clinic.

Analysis of the Risk Factors of Hematoma Enlargement in Patients with Spontaneous Intracerebral Hemorrhage (자발성 뇌실질내 출혈 환자에서 혈종 증가의 위험 인자에 대한 분석)

  • Lee, Yong-Mook;Koh, Hyeon-Song;Youm, Jin-Young;Kim, Seong-Ho;Song, Shi-Hun;Kim, Youn
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.437-442
    • /
    • 2001
  • Objective : The purpose of this study was to evaluate the risk factors of hematoma enlargement in patients with spontaneous intracerebral hemorrhage(ICH). Methods : A series of 214 ICH patients diagnosed by brain CT scan in our neurosurgery department from June 1995 to July 1998 were reviewed with clinical status, past medical histories, laboratory findings, CT findings and prognosis. Results : In 27 patients(12.6%), the second CT scan showed an enlarged hematoma. Age, sex, and site of hematoma were not related to hematoma enlargement. A long interval(>6 hours) between the onset and the 1st CT scan strongly reduced the incidence of hematoma enlargement. The incidence of hematoma enlargement significantly increased in patients with previous history of hypertension, cerebral infarction and ICH. This analysis also demonstrated the following independent factors predisposed to hematoma enlargement : initial high systolic blood pressure, high serum total protein, low serum albumin, low serum sodium, prolonged prothrombin time(>14 sec) and activated partial thromboplastin time(>29.5 sec), irregular hematoma shape, and combined intraventricular hemorrhage. Prognosis in the group of hematoma enlargement showed high mortality(48.1%) and poor outcome. Conclusion : Patients with previous history of hypertension, cerebral infarction and ICH, and with high systolic blood pressure, prolonged coagulation time, irregular hematoma shape and intraventricular hemorrhage in CT scan should be observed carefully. And, early surgical therapy of large hematoma and meticulous control of blood pressure may decrease the mortality and morbidity in patients with spontaneous ICH.

  • PDF

Development of an Arachnoid Cyst after Ventriculoperitoneal Shunt Placement - A Case Report - (뇌실복강간 단락술 후 발생한 뇌지주막 낭종 - 증 례 보 고 -)

  • Choi, Kwang Yeong;Rhee, Bong Arm;Lim, Young Jin;Kim, Tae Sung;Kim, Gook Ki;Leem, Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.364-367
    • /
    • 2001
  • A 4-month-old female patient admitted because of hydrocephalus. She was premature infant with germinal matrix hemorrhage at gestational period 27 wks. A ventriculoperitoneal shunt with a low-pressure type valve was placed. Follow-up CT scan obtained 3 months after VP shunt placement, revealed a new Lt. middle cranial fossa cyst. The girl was readmitted to hospital at 7 months after VP shunt placement, complaining of lethargy and vomiting. A CT scan was demonstrated a increase in size of a cyst, She subsequently underwent a left-sided pterional craniotomy with partial excision of membrane and cyst fenestration into the basal cisterns. Follow-up CT scan after 18 months revealed reaccumulation of cyst, the girl was reoperated on. After 2 months, the size of cyst was not decreased. Finally, She underwent a cystoperitoneal shunt. Follow-up CT scan after 5 months was demonstrated disappeared cyst and reexpansion of brain parenchyma. We report the development of a symptomatic sylvian fissure arachnoid cyst developed after ventriculoperitoneal shunt.

  • PDF

Annealing under low oxygen partial pressure for crystal growth of BaTiO$_3 $thin films prepared by coating-pyrolysis process (코딩-열분해법에 의해 제조한 BaTiO$_3 $ 박막의 결정 성장을 위한 낮은 산소 분압에서의 열처리)

  • Kim, Seung-Won
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.10 no.2
    • /
    • pp.111-115
    • /
    • 2000
  • $BaTIO_3$ thin films were prepared on (100) $BaTIO_3$ substrates by coating- pyrolysis process using metal-organic compounds of Ba and Ti. The amorphous films prefired at $450^{\circ}C$were crystallized above $700^{\circ}C$ under oxygen partial pressure of $2\times 10^{-4}$. The lattice parameters of the perpendicular axis for the $BaTIO_3$ thin films heat-treated below $800^{\circ}C$ were closer to a value of cubic $BaTIO_3$, whereas those above $800^{\circ}C$ were closer to a value of tetragonal BaTiG. The results of XRD P scan and pole-figure analyses indicated that BaTiO, thin films have an epitaxial relationship with the $SrTiO_3$ substrates. The $BaTIO_3$thin films annealed at$800^{\circ}C$ showed the surface with island-like grains about 0.4$mu \textrm{m}$ and the cross section of 0.8 $mu \textrm{m}$ thickness with granular grains.

  • PDF

A case of removable dentures using digital method (디지털 방식을 이용하여 제작한 양악 가철성 의치 수복 증례)

  • Lee, Ji-Soo;Ahn, Su-Jin;Leesungbok, Richard;Lee, Suk-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.250-257
    • /
    • 2018
  • Generally dentures are manufactured by conventional method, however the frequency of fabricating denture using digital method is increasing due to the recent development of digital technology in dentistry. The digital method of manufacturing denture is classified into two systems; 3D scan of the impression to arrange the artificial teeth on the CAD (Computer-aided design) and 3D printing to produce the resin-based complete denture, or 3D scan of the model to design of the framework using CAD, resin pattern formation by 3D printing and casting of metal framework of complete denture or removable partial denture. In this case report, electronic surveying and design the metal framework of the dentures were performed using CAD program, and plastic resin patterns fabricated by 3D printing were casted for upper full denture and lower removable partial denture. During follow-up periods, dentures using digital method have provided satisfactory results esthetically and functionally.