• 제목/요약/키워드: Partial flow rate

검색결과 230건 처리시간 0.021초

J-그루브에 의한 인듀서의 캐비테이션 억제 (Suppression of Cavitation in Inducer by J-Groove)

  • 쿠로카와준이치;최영도
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.776-781
    • /
    • 2005
  • Cavitation is the most serious problem caused in developing high-speed turbopump, and use of an inducer is often made to avoid cavitation in main impeller. Thus, the inducer always operates under the worst condition of cavitation. If it could be possible to control and suppress cavitation in the inducer by some new device, it would also be possible to suppress cavitation occurring in all types of pumps. The purpose of our present study is to develop a new effective method of controlling and suppressing cavitation in an inducer using shallow grooves, named as "J-Groove", J-Groove is installed on the casing wall near the blade tip to use the pressure difference between high pressure region and low pressure region in the axial direction at the inlet of the inducer. The results show that proper combination of backward-swept inducer with J-Groove improves suction performance of turbopump remarkably in the range of partial flow rate as well as designed flow rate. The rotating backflow cavitation occurring in the range of low flow rate and the cavitation surge occurring in the vicinity of the best efficiency point can be almost fully suppressed by installing J-Groove.

  • PDF

J-그루브를 이용한 인듀서의 캐비테이션 억제에 관한 연구 (A Study on the Suppression of Cavitation in Inducer by J-Groove)

  • 최영도;쿠로카와준이치
    • 대한기계학회논문집B
    • /
    • 제29권11호
    • /
    • pp.1239-1247
    • /
    • 2005
  • Cavitation is the most serious problem in developing high-speed turbopump, and inducer is often used to avoid cavitation in main impeller. Thus, inducer is always operating in the worst .cavitation condition. If it is possible to control and suppress cavitation in inducer by some new device, it might be possible to suppress cavitation occurring in any type of pumps. The purpose of present study is to develop a new effective method of controlling and suppressing cavitation in inducer using shallow grooves, which is named 'J-Groove'. J-Groove is installed on the casing wall near the blade tip to use the pressure difference between high pressure region and low pressure region of the inducer in an axial direction. The results show that proper combination of backward-swept inducer with J-Groove improves suction performance of turbopump remarkably in the range of partial flow rate as well as designed flow rate. The rotating backflow cavitation occurring in the range of low flow rate and the cavitation surge occurring in the vicinity of the best efficiency point can be almost suppressed by installing J-Groove.

다중 유로에서 과열도의 불균형에 따른 증발기의 성능 특성에 관한 연구 (The Effect of Non-uniform Superheat on the Performance of a Multi-path Evaporator)

  • 최종민;김용찬
    • 설비공학논문집
    • /
    • 제15권12호
    • /
    • pp.1043-1048
    • /
    • 2003
  • An experimental investigation was executed to determine the capacity degradation due to non-uniform refrigerant distribution in a multi-path evaporator. In addition, the possibility of recovering the capacity reduction by controlling the refrigerant distribution among refrigerant paths was assessed. The finned-tube evaporator, which had a three-path and three-depth-row, was tested by controlling inlet quality, exit pressure, and exit superheat for each refrigerant path. The capacity reduction due to superheat unbalance between each path was as much as 30%, even when the overall evaporator superheat was kept at a target value of 5.6$^{\circ}C$. It may indicate that the internal heat transfer within the evaporator assembly caused the partial capacity drop. For the evaporator having air mal-distributions, the maximum capacity reduction was found to be 8.7%. A 4.5% capacity recovery was obtained by controlling refrigerant distribution to obtain the target superheat at the outlet of each path.

Air-Water Countercurrent Flow Limitation in a Horizontal Pipe Connected to an Inclined Riser

  • Kang, Seong-Kwon;Chu, In-Cheol;No, Hee-Cheon;Chun, Moon-Hyun;Sung, Chang-Kyung
    • Nuclear Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.548-560
    • /
    • 1999
  • An experimental investigation has been peformed to examine the effects of various geometrical parameters and an initial operating condition on the air-water countercurrent How limitation (CCFL) in a simulated PWR hot leg. A total of 118 experimental data for the onset of CCFL and zero liquid penetration were obtained for various combinations of test parameters. It was observe that the CCFL can be classified into three different categories: (the onset of CCFL, (the partial liquid delivery, and (r) the zero liquid penetration. The observed mechanisms of the onset of CCFL were different depending on the inlet water flow rate. The parametric effects of pipe diameter, horizontal pipe length, horizontal pipe length-to-diameter (L/D) ratio, and initial water level in the horizontal pipe of the test section on the onset of air-water CCFL were also examined. An empirical correlation for the onset of CCFL in a horizontal pipe connected to an inclined riser was developed in terms of Wallis flooding parameters for the low inlet water flow rate region. Comparisons of the present empirical correlation with the air-water CCFL data of large pipe diameters show that the present correlation agrees more closely with the experimental data than the existing CCFL correlations.

  • PDF

랫드의 간암 발생과정에서 분리한 자연살해세포의 활성측정 및 특성연구 (Study on natural killer cell activity and its characteristics during hepatocarcinogenesis in rats)

  • 정자영;이국경;길광섭;이영순
    • 대한수의학회지
    • /
    • 제39권1호
    • /
    • pp.169-176
    • /
    • 1999
  • The purposes of this study were to set up the method of the natural killer(NK) cell activity assay using the flow cytometer and to examine the characteristics and distribution of the NK cell during rat hepatocarcinogenesis. Forty five male 6 week-old specific pathogen free(SPF) Sprague-Dawley rats were randomly divided into three groups. Group I was the non-treated control and given normal diet and water. Group II was treated with diethylnitrosamine(DEN, 200mg/kg, i.p.) and partial hepatectomy. Group III was treated with DEN, partial hepatectomy and 0.05% phenobarbital sodium in water from 3 to 16 weeks. All animals were examined the morphology of the large granular lymphocyte(LGL), the LGL percent of the total lymphocytes and the LGL conjugation rate with YAC-1 cell in peripheral blood, spleen and liver. Moreover, activity of the LGL isolated from peripheral blood lymphocytes was determined using the flow cytometer. As results, LGL were observed in the peripheral blood, spleen and liver. LGL were observed the relatively faintly staining basophilic cytoplasm with granules, and eccentric, often kidney-shaped nuclei in Giemsa stain. Its size was $11{\sim}13{\mu}m$. LGL percentage of the isolated lymphocytes in peripheral blood, spleen and liver were 1.8~2.3%, 1.3~1.4% and 0.87~0.99%, respectively. LGL conjugation rate with YAC-1 cell was shown to be peripheral blood(9.3~10.3 %) > spleen(7.7~8.7%) > liver(5.6~7.0%). The activity of the LGL isolated from peripheral blood lymphocytes in Group I, II and III was 33.7%, 30.5% and 35.4%, respectively. However, all values were not significantly between groups.

  • PDF

후두 우상암에서 후두 부분적출술 및 가성대 전진피판에 의한 성대 재건술 전후의 음성변화 : 2례 (Postoperative Phonetic Evaluation of Two Cases of Verrucous Carcinoma of the Larynx after Partial Laryngectomy with False Vocal Cord Advancement Flap)

  • 정성민;장주애;김윤정
    • 대한후두음성언어의학회지
    • /
    • 제9권1호
    • /
    • pp.86-90
    • /
    • 1998
  • Verrucous carcinoma is a variant of highly differentiated squamous cell carcinoma and has a predilection for the oral cavity and larynx. It is known to be of good prognosis due to its low regional and distant metastatic potential. Peak incidence is at ages 40-69 while predominantly occuring in males and its association with tobacco smoking has been implicated. The verrucous carcinoma have accordingly been treated by radiotherapy or surgical procedures but there has been considerable controversy regarding the effect of radiotherapy due to the possibility of anaplastic transformation Laser surgery and partial resection are among the commonly used surgical procedures but laser surgery has not yet shown results in improving phonetic abilities. Authors experienced two cases of verrucous carcinoma of the larynx treated by partial laryngectomy and false vocal cord advancement flap who showed no recurrence of disease under stroboscopic examination after two year follow up and when compared to preoperative aerodynamic studies, the expiratory air pressure was decreased and mean air flow rate increased which improved glottal efficiency markedly.

  • PDF

4성분계 복합 산화물 촉매 이용 메탄의 부분산화에 의한 메탄올 직접 합성 (Direct Methanol Synthesis by Partial Oxidation of Methane over Four-component Mixed Oxide Catalysts)

  • 김영국;이광혁;함현식
    • 한국응용과학기술학회지
    • /
    • 제31권3호
    • /
    • pp.446-452
    • /
    • 2014
  • Methanol was directly produced by the partial oxidation of methane with four-component mixed oxide catalysts. Four-component(Mo-Bi-Cr-Si) mixed oxide catalysts were prepared by the co-precipitation and sol-gel methods. The catalyst prepared by the sol-gel method showed about eleven times higher surface area than that prepared by the co-precipitation method. From the $O_2$-TPD experiment of the prepared catalysts, it was proven that there exists two types of oxygen species, and the oxygen species that participates in the partial oxidation reaction is the lattice oxygen desorbing around $750^{\circ}C$. The optimum reaction condition for methanol production was $420^{\circ}C$, 50 bar, flow rate of 115 mL/min, and $CH_4/O_2$ ratio of 10/1.5, providing methane conversion and methanol selectivity of 3.2 and 26.7%, respectively.

Generic studies on thermo-solutal convection of mercurous chloride system of ${Hg_2}{Cl_2}$ and Ne during physical vapor transport

  • Choi, Jeong-Gil;Lee, Kyong-Hwan;Kim, Geug-Tae
    • 한국결정성장학회지
    • /
    • 제19권1호
    • /
    • pp.39-47
    • /
    • 2009
  • The effects of thermo-solutal convection on mercurous chloride system of ${Hg_2}{Cl_2}$, and Ne during physical vapor transport are numerically investigated for further understanding and insight into essence of transport phenomena, For $10\;K{\le}{\Delta}T{\le}30\;K$, the growth rate slowly increases and, then is decreased gradually until ${\Delta}T$=50 K, The occurrence of this critical point near at ${\Delta}T$=30 K is likely to be due to the effects of thermo-physical properties stronger than the temperature gradient corresponding to driving force for thermal convection. For the range of $10\;Torr{\le}P_B{\le}300\;Torr$, the rate is second order-exponentially decayed with partial pressures of component B, $P_B$. For the range of $5{\le}M_B{\le}200$, the rate is second order-exponentially decayed with a function of molecular weight of component B, $M_B$. Like the case of a partial pressure of component B, the effects of a molecular weight arc: reflected through the binary diffusivity coefficients, which are intimately related with suppressing the convection flow inside the growth enclosure, i,e., transition from convection to diffusion-dominant flow mode as the molecular weight of B increases. The convective mode is near at a ground level, i,e., on earth (1 $g_0$), and the convection is switched to the diffusion mode for $0.1\;g_0{\le}g{\le}10^{-2}g_0$, whereas the diffusion region ranges from $10^{-2}g_0$ up to $10^{-5}g_0$.

ESS(Energy Storage System) 열관리를 위한 액침 냉각 활용에 대한 수치해석 연구 (Numerical Study on using Immersion Cooling for Thermal Management of ESS (Energy Storage System))

  • 함정균;유나영;신명재;조홍현
    • 한국지열·수열에너지학회논문집
    • /
    • 제20권2호
    • /
    • pp.1-10
    • /
    • 2024
  • The introduction of the sector coupling concept has expanded the scope of ESS utilization, resulting in the importance of thermal management of ESS. To ensure the safe use of the lithium-ion batteries that are used in ESS, it is important to use the batteries at the optimal temperature. To examine the utilization of liquid cooling in ESS, numerical study was conducted on the thermal characteristics of 21700 battery modules (16S2P array) during liquid cooling using Novec-649 as insulating fluid. The NTGK model, an MSMD model in ANSYS fluent, was used to investigate thermal characteristics on the battery modules with liquid immersion cooling. The results show that the final temperature of the battery module discharged at 5 C-rate is 68.9℃ using natural convection and 48.3℃ using liquid cooling. However, the temperature difference among cells in the battery module was up to 0.5℃ when using natural convection cooling and 5.8℃ when using liquid cooling, respectively, indicating that the temperature difference among cells was significantly increased when liquid cooling was used. As the mass flow rate increased from 0.01 kg/s to 0.05 kg/s, the average temperature of the battery module decreased from 48.3℃ to 38.4℃, confirming that increasing the mass flow rate of the insulating fluid improves the performance of liquid immersion cooling. Although partial liquid immersion cooling has a high cooling performance compared to natural convection cooling, the temperature difference between modules was up to 8.9℃, indicating that the thermal stress of the battery cells increased.

Effect of a chemical reaction on magnetohydrodynamic (MHD) stagnation point flow of Walters-B nanofluid with newtonian heat and mass conditions

  • Qayyum, Sajid;Hayat, Tasawar;Shehzad, Sabir A.;Alsaedi, Ahmed
    • Nuclear Engineering and Technology
    • /
    • 제49권8호
    • /
    • pp.1636-1644
    • /
    • 2017
  • The main purpose of this article is to describe the magnetohydrodynamic stagnation point flow of Walter-B nanofluid over a stretching sheet. The phenomena of heat and mass transfer are based on the involvement of thermal radiation and chemical reaction. Characteristics of Newtonian heating are given special attention. The Brownian motion and thermophoresis models are introduced in the temperature and concentration expressions. Appropriate variables are implemented for the transformation of partial differential frameworks into sets of ordinary differential equations. Plots for velocity, temperature, and nanoparticle concentration are displayed and analyzed for governing parameters. The skin friction coefficient and local Nusselt and Sherwood numbers are studied using numerical values. The temperature and heat transfer rate are enhanced within the frame of the thermal conjugate parameter.