• 제목/요약/키워드: Partial factor

Search Result 1,132, Processing Time 0.041 seconds

Partial Safety Factor of Offshore Wind Turbine Pile Foundation in West-South Mainland Sea (서남해안 해상풍력단지 말뚝기초의 부분안전계수)

  • Yoon, Gil Lim;Kim, Sun Bin;Kwon, O Soon;Yoo, Moo Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1489-1504
    • /
    • 2014
  • This paper is aimed to suggest a site specific partial safety factor of offshore wind turbine (OWT) pile foundation design for the offshore wind turbine complex at a West-South mainland sea in Korea. International offshore wind design standards such as IEC, GL, DNV, API, ISO and EUROCODE were compared with each partial safety factor and resistance factor. Soil uncertainty analysis using a large number of soil data sampled was carried out, and their results were adapted to estimate partial safety factor of OWT pile foundation through reliability analyses. The representative partial safety factor has been estimated as 1.3. When a proposed partial factor is willing to use to other sites, it is recommended that further studies on code calibration are required to validate their accuracy using more site characterization data.

Diagnostics of partial regression and partial residual plots

  • Lee, Jea-Young;Choi, Suk-Hwa
    • Journal of the Korean Data and Information Science Society
    • /
    • v.11 no.1
    • /
    • pp.73-81
    • /
    • 2000
  • The variance inflation factor can be expressed by the square of the ratio of t-statistics associated with slopes of partial regression and partial residual plots. Disagreement of two sides in the interpretation can be occurred, and we analyze it with some illustrations.

  • PDF

Classifications of Arm and Correspondence with Partial Somatotype of Upper Body (팔의 유형화와 상반신 부분체형과의 대응에 관한 연구)

  • 이정란
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.6
    • /
    • pp.864-875
    • /
    • 1999
  • This study was done to classify type os arms and to correspond these types with partial somatotype of upper body such as lateral views of upper body shapes of shoulder. The subjects of this study were female college students of twenties 58 anthropometric and photographic data were measured. The results were as follows : 1. Form the factor analysis arm girth/armscye size factor arm length factor the slope of lower arm, arm factor the curves of armscye the roundness of arm/shapes of shoulder the slope of upper arm factor were obtained. 2. By using factor scores 4 clusters of arm types were extracted. The characteristics of these clusters were projections of armscy slant of lower arm thick-set canelike. 3. Four types of arm were corresponded with the specified lateral views of upper body directions of shoulder slopes of shoulder.

  • PDF

Effects of Kurtosis on the Pressure Flow Factor (Kurtosis 변화에 따른 Pressure Flow Factor에 관한 연구)

  • 강민호;김태완;구영필;조용주
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.06a
    • /
    • pp.243-250
    • /
    • 2000
  • In the partial lubrication regime, the roughness effects are most important due to the presence of interacting asperities. An average Reynolds equation using flow factors is very useful to determine effects of surface roughness on partial lubrication. In this paper, the pressure flow factors for Gaussian and non-Gaussian surfaces are evaluated in terms of kurtosis. The effect of kurtosis on pressure flow factor is investigated using random rough surface generated numerically. The pressure flow factor increases with increasing kurtosis in partial lubrication regime(h/$\sigma$<3). As h/$\sigma$increases, the pressure flow factor approach to 1 asymptotically regardless of kurtosis.

  • PDF

Lateral Vibration of Beams with a Bonded Lap Joint and Partial Layered Dampers (겹침이음부 및 국부적 층댐퍼를 갖는 보의 횡진동 특성)

  • 박정일;최낙삼
    • Journal of KSNVE
    • /
    • v.9 no.1
    • /
    • pp.174-183
    • /
    • 1999
  • An analytical model for the lateral vibration of beams with a bonded lap joint and partial layered dampers has been proposed in this paper. Both shear and normal forces acting along the interface between the elastic and viscoelastic layers were considered in the vibration analysis. Analytical results were compared with those obtained by a finite element method. Effects of the size and location of layers in partial dampers on system loss factor($\eta_s$) and resonant frequency($\omega_r$) were studied. which showed that partial dampers adhered to the site exhibiting the maximum amplitude of vibration were most influential in the increase of $\eta_s$ and the decrease of $\omega_r$. Specific system loss factor( $\eta_s$ divided by total mass of system) was also evaluated in the analysis.

  • PDF

A High Power Factor and High Efficiency Three Phase Boost Converter using auxiliary Partial Resonant circuit (보조 부분 공진 회로를 이용한 고역률 고효율 삼상 부스트 컨버터)

  • Suh, Ki-Young;Kwon, Soon-Kurl;Lee, Hyun-Woo;Kim, Young-Mun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.4
    • /
    • pp.212-218
    • /
    • 1999
  • A new partial resonant three phase boost converter with high power factor and high efficiency is proposed. The proposed boost converter is constructed by using a resonant network in parallel with the swithch of the conventional boost converter. The devices are switched at zero voltage or zero current eliminating the switching loss. A new auxiliary partial resonant boost converter achieves zero-voltage switching(ZVS) or zero-current switching(ZCS) for all switch devices without increasing their voltage and current stresses.

  • PDF

PARTIAL INTRINSIC BAYES FACTOR

  • Joo Y.;Casella G.
    • Journal of the Korean Statistical Society
    • /
    • v.35 no.3
    • /
    • pp.261-280
    • /
    • 2006
  • We have developed a new model selection criteria, the partial intrinsic Bayes factor, which is designed for cases when we select a model among a small number of candidate models. For example, we can choose only a few candidate models after exploring scatter plots. By simulation study, we have showed that PIBF performs better than AIC, BIC and GCV.

A study on the heat cycle aging of insulation materials in large generator stator windings (대형발전기 고정자권선 절연재료의 열 사이클에 의한 열화에 관한 연구)

  • 김희곤;박영관
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.553-557
    • /
    • 1996
  • Heat cycle aging of insulating materials in large generator stator winding has been investigated using both on-line and off-line test methods. On this study, principally, off-line test against actual generator in service was carried out to acquire information about polarization index(PI) and dissipation factor, dissipation factor tip-up, maximum partial discharge for the purpose of remnant breakdown voltage and life assessment. It was found from the tests that both dissipation factor and maximum partial discharge decreased with the increase of operating hours and starting numbers. It was found from off-line tests that the remnant breakdown voltage had a strong relationship with both dissipation factor and maximum partial discharge the remnant breakdown voltage as a results of both operating hours and starting number and the nondestructive tests were proposed as parameters which can predict the remnant lifetime of insulating materials in large generator stator windings. (author). 8 refs., 8 figs., 2 tabs.

  • PDF

Reliability based partial safety factor of concrete containing nano silica and silica fume

  • Nanda, Anil Kumar;Bansal, Prem Pal;Kumar, Maneek
    • Computers and Concrete
    • /
    • v.26 no.5
    • /
    • pp.385-395
    • /
    • 2020
  • The influence of combination of nano silica and silica fume, as partial cement replacement materials, on the properties of concrete has been studied through the measurement of compressive strength. The compressive strength of concrete in terms of mean, standard deviation and with-in-test coefficient of variation related to the variation in the nominated parameters have also been developed. The compressive strength data developed experimentally has been analyzed using normal-probability distribution and partial safety factors of composite concretes have been evaluated by using first order second moment approach with Hasofer Lind's method. The use of Nano silica and silica fume in concrete decreases the partial safety factor of concrete i.e., increase the reliability of concrete. The experimental results show that the properties of concrete having nano silica and silica fume in combination were better than that of a plain concrete. The SEM test results showing the level of Ca(OH)2 in plain concrete and consumption level Ca(OH)2 of concrete containing nano silica & silica fume have also been presented.

Response Modification Factors for Seismic Performance Evaluation of Non-seismic School Buildings with Partial Masonry Infills (조적허리벽이 있는 비내진 학교시설의 내진성능평가를 위한 반응수정계수)

  • Kim, Beom Seok;Park, Ji-Hun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.1
    • /
    • pp.71-82
    • /
    • 2019
  • Most school buildings consist of reinforced concrete (RC) moment frames with masonry infills. The longitudinal direction frames of those school buildings are relatively weak due to the short-column effects caused by the partial masonry infills and need to be evaluated carefully. In 'Manual for Seismic Performance Evaluation and Retrofit of School Facilities' published in 2018, response modification factor of 2.5 is applied to non-seismic RC moment frames with partial masonry infills, but sufficient verification of the factor has not been reported yet. Therefore, this study conducted seismic performance evaluation of planar RC moment frames with partial masonry infills in accordance with both linear analysis and nonlinear static analysis procedures presented in the manual. The evaluation results from the different procedures are compared in terms of assessed performance levels and number of members not meeting target performance objectives. Finally, appropriate response modification factors are proposed with respect to a shear-controlled column ratio.