• 제목/요약/키워드: Partial discharge property

검색결과 29건 처리시간 0.021초

마이카-에폭시 복합절연계 계면층의 부분방전 특성에 관한 연구 (A Study on Partial Discharge Propeties of Interface Layer in-Mica-Epoxy Composite Material)

  • 이은학;김태성;박종건;이덕출
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1991년도 추계학술대회 논문집
    • /
    • pp.83-89
    • /
    • 1991
  • The partial discharge properties of interface layer in Mica-Epoxy composite, which has been mainly used for the coil insulating material of high voltage machinery, are different from those of resins due to the abnormal interface layer to be presented between inorganic material and resin. Accordingly, the study on discharge of interface in composite insulting system is strongly requsted for not only an increasing of insulating strength, but also the basical information of diagnosis system for high voltage equipment. As a result, it has been confirmed that the interface is an abnormal resin layer and the contact states at interface is depended upon the density of silane aqueous solution. Pulse frequency at abnormal interface shows a linear increasing with enlargement of discharge quantity. Whereas, in case of normal interface, pulse frequency property represents exponential increasing at the point of saturating. A life model can be diagramed from results of time dependance of skewness, and a survival life time can be quantified from the life model suggested.

박 센서 배열에 따른 154kV XLPE 케이블의 부분방전 검출 특성 연구 (Partial Discharge Quality Measurement improvement of XLPE Cable of 154kV by new method of FSA)

  • 신동훈;양종석;;임종천;황두현;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.158-159
    • /
    • 2006
  • The system measuring the Partial discharge(PD) is very essential to investigate the hazard defects in the insulation systems of the high voltage engineering. We included two parts in this discussion; The proposed method of Foil Sensor Array and the normally used method m the practice. Firstly, it will be shown the improved sensitivity of our proposed FSA sensor compare with the existing normal foil sensor. And then, the linearity of detecting sensitivities of various kinds of FSA sensors such as $2{\times}2$, $2{\times}4$, $3{\times}3$ etc. using in our experiments, was shown. From the obtained results, we can see that FSA sensor is more sensitivity than normal foil sensor and the linear increment property of FSA sensitivities.

  • PDF

154 kV XLPE 전력케이블의 부분방전 측정을 위한 FSA의 적용 및 표준화 연구 (A Study on FSA Application and Standardization for Partial Discharge Measurement of 154 kV XLPE Cable)

  • 신동훈;;양종석;황두현;임종천;박노준;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제20권5호
    • /
    • pp.462-466
    • /
    • 2007
  • The measuring system of the Partial discharge(PD) is very essential to investigate the hazard defects in the insulation systems of the high voltage engineering. We will discussed this research which has included two parts. The proposed method of Foil Sensor Array(FSA) and the normally used method in the practice. Firstly, it will be shown the improved sensitivity of a FSA sensor, which is our aim, compare with the existing normal foil sensor. And then, the linearity of detecting sensitivities of various kinds of FSA sensors was shown. According to our experiments, we can see that FSA sensor is more sensitivity than normal foil sensor and the linear increment property of FSA sensitivities.

에폭시 몰드형 PT의 절연특성 개선 (Improvement on Property of Insulation in PT of Epoxy Mold Type)

  • 송재주;김성홍;최명호;이재;임성훈;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 기술교육위원회 창립총회 및 학술대회 의료기기전시회
    • /
    • pp.67-71
    • /
    • 2001
  • PT of epoxy mold type have tendency to occur dielectric breakdown in high voltage system. These are using for measurement of voltage or protection of system and application voltage is 25.8kV. Therefore, for improving a lots of problems like as partial discharge, we had analyze on the destroyed Epoxy molded type PT and processing of production. As a results, we concluded that the reason of dielectric breakdown was defect of processing and degradation of insulation by electrical stress. In this work, We presented a method of solution in processing of production. which is reduction of the PO which was occurred at the insulation material. so we must many try to remove faults, these problems are mainly to winding methods of 1st coil. the other side, Reformation of 1st coil improved property of PD and we could prove it with experiments.

  • PDF

GIS 설비 진단을 위한 포터블 부분방전 측정장치 개발 및 응용 (A Development of Measuring Instrument of Portable Partial Discharge for Diagnosis of GIS Installation and Application)

  • 김종서;김진태;신흥식;이홍재
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.231-234
    • /
    • 2009
  • Recently, to the development of a highly information-oriented society to a large increase in dependence on power, Accordingly, it is need that active development and spread of preservation technology on accident prevention in operation electrical equipment. However, to lack of the use on maintenance technology of power equipment and to increase of power usage is growing deterioration of power equipment, this is a cause on casualties, property damage and the occurrence of disasters is a growing. GIS equipments which are operated from domestic except the equipment which manages from the big business are depend on a most visual inspection, and do inspection method or measuring instrument etc. a condition which is not supplied widely. Currently, many to measure instrument used in domestic is very expensive or foreign, it will be able to substitute this, the development necessity of the diagnosis technique and the measuring instrument is demanded.

RF-Sputted Vanadium Oxide Thin Films:Effect of Oxygen Partial Pressure on Structural and Electrochemical Properties

  • 박용준;박남규;류광선;장순호;박신종;윤선미;김동국
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권9호
    • /
    • pp.1015-1018
    • /
    • 2001
  • Vanadium oxide thin films with thickness of about 2000 $\AA$ have been prepared by radio frequency sputter deposition using a V2O5 target in a mixed argon and oxygen atmosphere with different Ar/O2 ratio ranging from 99/1 to 90/10. X-ray diffraction and X-ray absorption near edge structure spectroscopic studies show that the oxygen content higher than 5% crystallizes a stoichiometric V2O5 phase, while oxygen deficient phase is formed in the lower oxygen content. The oxygen content in the mixed Ar + O2 has a significant influence on electrochemical lithium insertion/deinsertion property. The discharge-charge capacity of vanadium oxide film increases with increasing the reactive oxygen content. The V2O5 film deposited at the Ar/O2 ratio of 90/10 exhibits high discharge capacity of 100 ${\mu}Ah/cm2-{\mu}m$ along with good cycle performance.

분사법을 이용한 면직물의 부분탈색 (Partial Fading-out of Cotton Fabrics by Spray Method)

  • 김인회;김희선;남성우
    • 한국염색가공학회지
    • /
    • 제14권5호
    • /
    • pp.294-301
    • /
    • 2002
  • The effects of various parameters on partial decoloration of cotton dyeings using discharge reactive dye were investigated. The decoloration of dyed cotton fabrics with varying pH were very sensitive below 100g/1 of amount of potassium carbonate. Our results did indicate any significant changes in color when the amount of Rongalite C in reducing liquor was increased 10g/l to 200g/l. The steaming time had significant effects on fade-out, with an steaming time of 3~5 min. being sufficient for deceleration build up. The change of color below $130^\circ{C}$ was not significant and it only become evident above $140^\circ{C}$. The additional color changes did not cause by washing under suitable concentrations of oxidation and neutralization agents. The decoloration treatment did not affect the mechanical property of cotton fabrics such as tensile strength.

AC Plasma Display Panel (PDP)에서 MgO 박막의 내스퍼터성에 관한 연구 (A Study on the Sputtering-resistant Properties of MgO Thin-film in the AC Plasma Display Panel (PDP))

  • 지성원;여재영;이우근;조정수;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권5호
    • /
    • pp.361-366
    • /
    • 1999
  • The life of AC PDP depends largely on the sputtering-resistant property of the protecting layer such as MgO thin-film. However, it is very difficult to measure the sputtering-resistant property in the stable driving conditions of AC PDP. In this paper we have suggested a high speed measurement technique of the sputtering-resistant property of MgO thin-film by applying the MgO thin-film as the target of RF magnetron sputtering system. We have also applied this method to the e-beam MgO and sputter-MgO and e-beam MgO superior to sputter-MgO 3 times over. Also, the relation of Xe gas partial pressure(X) and sputtered thickness(Y) was Y=3.4X+13.5.

  • PDF

Improving Accuracy of Soil Property Measurements by NIR Spectroscopy

  • Ryu, Kwan Shig;Cho, Rae Kwang;Park, Woo Churl;Kim, Bok Jin
    • Journal of Applied Biological Chemistry
    • /
    • 제44권4호
    • /
    • pp.177-179
    • /
    • 2001
  • Traditional wet chemical methods for testing of soil properties require extensive time and labor, and cause the discharge of pollutants, making them undesirable for routine soil analyses. This research was conducted to improve the accuracy of soil properties in soil fertility assessments. A total of 140 finely ground soil samples were used to obtain accurate calibrations and validation for estimating soil moisture, OM, and T-N. Finely ground soil samples satisfied the improved accuracy for routine NIR measuring of the field soils. The results indicated that NIR spectroscopy could be used as a routine method for quantitatively determining OM, moisture, and T-N of field soil, although this technique requires many combinations of sample pretreatments and data manipulations to obtain optimal predictions.

  • PDF

백화현상이 나타난 고압전동기 고정자권선의 절연특성 연구 (A Study on Insulation Property of White Powder Found on High Voltage Motor Stator Winding)

  • 공태식;김희동;이상길;김경열;주영호
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1627-1631
    • /
    • 2011
  • During a routine inspection of a large pump motor at power plant, white powder was found on the surface of the stator end windings. Visual inspection and high voltage insulation diagnosis was performed to determine whether this motor is available. The purpose of this paper is to understand the insulation properties of white powder found on high voltage stator and to know prevention of insulation weakness.