• Title/Summary/Keyword: Partial Test

Search Result 1,766, Processing Time 0.029 seconds

A Basic Study on the Application of Partial Discharge Test on Low-voltage Electrical and Electronic Devices (저압용 전기전자기기에 부분방전시험의 적용을 위한 기초연구)

  • Kil Gyung-Suk;Song Jae-Yong;Moon Seung-Bo;Cha Myung-Soo;Hwang Don-Ha;Kang Dong-Sik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.6
    • /
    • pp.586-590
    • /
    • 2006
  • This paper deals with the application of a partial discharge (PD) test on low-voltage electrical and electronic devices, which is recently being accepted as a non-destructive and a effective dielectric test method. A comparative analysis combined with the Withstand Voltage Test (WVT) specified in IEC standards was carried out on low-voltage insulation transformers. The results showed that the WVT causes insulation degradation of the specimen during the test by applying high voltage. However, the PD test can be performed in ranges from 30 % to 50 % of the test voltage specified in the WVT. Therefore, the PD test is successfully applicable for a non-destructive test method on low-voltage electrical and electronic devices as a replacement of the WVT.

Partial Enhanced Scan Method for Path Delay Fault Testing (경로 지연 고장 테스팅을 위한 부분 확장 주사방법)

  • Kim, Won-Gi;Kim, Myung-Gyun;Kang, Sung-Ho;Han, Gun-Hee
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.10
    • /
    • pp.3226-3235
    • /
    • 2000
  • The more complex and larger semiconductor integraed circuits become, the core important delay test becomes which guarantees that semiconductor integrated circuits operate in time. In this paper, we propose a new partial enhanced scan method that can generate test patterns for path delay faults offectively. We implemented a new partial enhanced scan method based on an automatic test pattern generator(ATPG) which uses implication and justification . First. we generate test patterns in the standard scan environment. And if test patterns are not generated regularly in the scan chain, we determine flip-flops which applied enhanced scan flip-flops using the information derived for running an automatic test pattern generator inthe circuti. Determming enhanced scan flip-flops are based on a fault coverage or a hardware overhead. through the expenment for JSCAS 89 benchmark sequential circuits, we compared the fault coverage in the standard scan enviroment and enhance scan environment, partial enhanced scan environment. And we proved the effectiveness of the new partial enhanced scan method by identifying a high fault coverage.

  • PDF

Regression Diagnostic Using Residual Plots

  • Oh, Kwang-Sik
    • Communications for Statistical Applications and Methods
    • /
    • v.8 no.2
    • /
    • pp.311-317
    • /
    • 2001
  • It is necessary to check the linearity of selected covariates in regression diagnostics. There are various graphical methods using residual plots such as partial residual plots, augmented partial residual plots and combining conditional expectation and residual plots. In this paper, we propose the modified pseudolikelihood ratio test statistics based on these residual plots to test linearity of selected covariate. These test statistics which measure the distance between the nonparametric and parametric models are derived as a ratio of quadratic forms. The approximate distribution of these statistics is calculated numerically by using three moments. The power comparison of these statistics is given.

  • PDF

Data Association of Robot Localization and Mapping Using Partial Compatibility Test (Partial Compatibility Test 를 이용한 로봇의 위치 추정 및 매핑의 Data Association)

  • Yan, Rui Jun;Choi, Youn Sung;Wu, Jing;Han, Chang Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.2
    • /
    • pp.129-138
    • /
    • 2016
  • This paper presents a natural corners-based SLAM (Simultaneous Localization and Mapping) with a robust data association algorithm in a real unknown environment. Corners are extracted from raw laser sensor data, which are chosen as landmarks for correcting the pose of mobile robot and building the map. In the proposed data association method, the extracted corners in every step are separated into several groups with small numbers of corners. In each group, local best matching vector between new corners and stored ones is found by joint compatibility, while nearest feature for every new corner is checked by individual compatibility. All these groups with local best matching vector and nearest feature candidate of each new corner are combined by partial compatibility with linear matching time. Finally, SLAM experiment results in an indoor environment based on the extracted corners show good robustness and low computation complexity of the proposed algorithms in comparison with existing methods.

Reliability based partial safety factor of concrete containing nano silica and silica fume

  • Nanda, Anil Kumar;Bansal, Prem Pal;Kumar, Maneek
    • Computers and Concrete
    • /
    • v.26 no.5
    • /
    • pp.385-395
    • /
    • 2020
  • The influence of combination of nano silica and silica fume, as partial cement replacement materials, on the properties of concrete has been studied through the measurement of compressive strength. The compressive strength of concrete in terms of mean, standard deviation and with-in-test coefficient of variation related to the variation in the nominated parameters have also been developed. The compressive strength data developed experimentally has been analyzed using normal-probability distribution and partial safety factors of composite concretes have been evaluated by using first order second moment approach with Hasofer Lind's method. The use of Nano silica and silica fume in concrete decreases the partial safety factor of concrete i.e., increase the reliability of concrete. The experimental results show that the properties of concrete having nano silica and silica fume in combination were better than that of a plain concrete. The SEM test results showing the level of Ca(OH)2 in plain concrete and consumption level Ca(OH)2 of concrete containing nano silica & silica fume have also been presented.

ppcor: An R Package for a Fast Calculation to Semi-partial Correlation Coefficients

  • Kim, Seongho
    • Communications for Statistical Applications and Methods
    • /
    • v.22 no.6
    • /
    • pp.665-674
    • /
    • 2015
  • Lack of a general matrix formula hampers implementation of the semi-partial correlation, also known as part correlation, to the higher-order coefficient. This is because the higher-order semi-partial correlation calculation using a recursive formula requires an enormous number of recursive calculations to obtain the correlation coefficients. To resolve this difficulty, we derive a general matrix formula of the semi-partial correlation for fast computation. The semi-partial correlations are then implemented on an R package ppcor along with the partial correlation. Owing to the general matrix formulas, users can readily calculate the coefficients of both partial and semi-partial correlations without computational burden. The package ppcor further provides users with the level of the statistical significance with its test statistic.

Experiments on the bearing capacity of tapered concrete filled double skin steel tubular (CFDST) stub columns

  • Ren, Qing-Xin;Hou, Chao;Lam, Dennis;Han, Lin-Hai
    • Steel and Composite Structures
    • /
    • v.17 no.5
    • /
    • pp.667-686
    • /
    • 2014
  • Tapered concrete filled double skin steel tubular (CFDST) columns have been used in China for structures such as electricity transmission towers. In practice, the bearing capacity related to the connection details on the top of the column is not fully understood. In this paper, the experimental behaviour of tapered CFDST stub columns subjected to axial partial compression is reported, sixteen specimens with top endplate and ten specimens without top endplate were tested. The test parameters included: (1) tapered angle, (2) top endplate thickness, and (3) partial compression area ratio. Test results show that the tapered CFDST stub columns under axial partial compression behaved in a ductile manner. The axial partial compressive behaviour and the failure modes of the tapered CFDST stub columns were significantly influenced by the parameters investigated. Finally, a simple formula for predicting the cross-sectional capacity of the tapered CFDST sections under axial partial compression is proposed.

The measurement of partial discharge for preventive diagnosis in power machinery (전력용 기기의 예방진단을 위한 부분방전측정)

  • 김태성;구할본;임장섭;정우성
    • Electrical & Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.42-48
    • /
    • 1994
  • The preventive diagnosis technique for power system is being highlighted as a research area for deterioration of insulation in machinery because of high-voltage power system. We make efforts to develop not only diagnosis of aging state but also detection of defects in the initial stage from preventive diagnosis technique. Especially, partial discharge is actively studied as a non-destructive diagnosis technique and very useful because partial discharge measurement reduces damage than conventional diagnosis technique. The loaded stress during this test is smaller than that of other diagnosis techniques. But the continuous research for various complicated analysis method is required because partial discharge has very small signals and its signals have complex forms. In this paper, the measurement of partial discharge was investigated and studied on many specimens with void. We made samples having artificial voids and measured partial discharge. In order to use as a practical diagnosis technique, we studied ways of measurement, measured illustrations and types of partial discharge which could be used in order to diagnose defects of power machinery.

  • PDF

Patterns of the Ultrasonic Signal caused by Partial Discharge in Transformer (변압기 부분방전에 의한 초음파 신호의 발생형태)

  • 권동진;최인혁;정길조;박찬영;나현석;박재준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.581-584
    • /
    • 2000
  • Generally, it is known that many partial discharges are occurred in one voltage cycle. In this case, it is not easy to distinguish between ultrasonic signals caused by the partial discharge. We describes a pattern of the ultrasonic signal by the partial discharge in transformer. The test setup for ultrasonic signal measurement was to simulate a internal partial discharge by using a needle to plane electrodes. We compared the number of partial discharge and ultrasonic signal in one voltage cycle. The results showed that it was possible to distinguish between ultrasonic signals by analysing partial discharge detection method and ultrasonic signal on time domain.

  • PDF